Sign Regulations in Blythewood, South Carolina
Blythewood, South Carolina has specific sign regulations covering 12 sign types across 15 zoning districts. Regulated sign types include Freestanding Sign, Wall Sign, Temporary Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Blythewood, South Carolina
Sample Sign Requirements in Blythewood
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Freestanding Sign | 6 ft. | 32 sq. ft. per side | Not listed |
| Wall Sign | Not listed | 20 sq. ft. per building | Not listed |
| Temporary Sign | 5 ft. | 32 sq. ft. | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
12
- Freestanding Sign
- Wall Sign
- Temporary Sign
- Projecting Sign
- +2 more types
Zoning Districts
15
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Blythewood
Other Cities in South Carolina
Frequently Asked Questions
In Blythewood, the height limit for Freestanding Sign in the Rural District (RU) is 8 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Blythewood require a permit. From the submission notes on this page: Applications for sign permits must include a sketch (dimensions, shape, proposed location) and any information required for compliance evaluation; one copy is provided post-approval/denial. Run a code check for an exact address to see the permit requirements for that zone.
Blythewood's sign code covers 12 sign types, including Freestanding Sign, Wall Sign, Temporary Sign, and Projecting Sign. Most commercial signs need a permit. The ordinance lists 19 exemptions. One of them: Changing or replacing sign copy on an existing lawful sign (if nature/structure isn't changed to render nonconforming); change of business does require permit. The full list is on this page.
In Blythewood, Freestanding Sign in the Rural District (RU) must be set back 5 ft from right-of-way, 15 ft from lot line. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Blythewood's sign ordinance that cover digital, changing, or flashing signs: Flashing, rotating, or blinking signs, signs with flashing or reflective disks, signs with lights of changing intensity or color, or electrically scrolled messages, are prohibited. Video displays, electronic changeable copy signs (outside of designated overlay districts), and electronic graphic display signs are prohibited. For changeable copy signs and electronic changeable copy signs, additional restrictions and architectural review (Certificate of Appropriateness) are required in the architectural overlay district. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Blythewood Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Blythewood, South Carolina, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Blythewood, South Carolina Sign Rules at a Glance
Blythewood, South Carolina regulates 12 sign types across 15 zoning districts. Freestanding Signs in the Rural District (RU) are capped at 8 ft tall and 32 sq ft, set back 5 ft from right-of-way, 15 ft from lot line. Most commercial signs in Blythewood require a permit.
Detailed Sign Ordinance Requirements for Blythewood, South Carolina
Sign Rules by Zoning District in Blythewood (15 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Rural Estate District (RE) | 3 | 6 ft. | 32 sq. ft. per side | Not listed |
| Rural District (RU) | 3 | 8 ft. | 32 sq. ft. | Not listed |
| Low Density Residential District (R-40) | 3 | 8 ft. | 32 sq. ft. | Not listed |
| Low Density Residential District (R-20) | 2 | 8 ft. | 32 sq. ft. | Not listed |
| Development District (D-1) | 2 | 8 ft. | 32 sq. ft. | Not listed |
| Single-Family Residential District (R-12) | 2 | 8 ft. | 32 sq. ft. | Not listed |
| One- and Two-Family Residential District (R-8) | 2 | 8 ft. | 32 sq. ft. | Not listed |
| General Residential District (R-5) | 2 | 8 ft. | 32 sq. ft. | Not listed |
| Neighborhood Office District (NO), Neighborhood Commercial District (NC), Multi-Neighborhood Office District (MO), Multi-Neighborhood Commercial District (MC) | 7 | 8 ft. | 50% of window area | Not listed |
| Town Center District (TC), Community Commercial District (CC) | 4 | 8 ft. | 32 sq. ft. (64 sq. ft. for multiple occupancy in TC/CC) | Not listed |
| Light Industrial Research Park District (LIRP), Limited Industrial District (LI), Basic Industrial District (BI), Limited Industrial 2 District (LI-2) | 2 | 8 ft. | 32 sq. ft. | Not listed |
| Planned Development District (PD) | 1 | As set in approved plan, but cannot exceed district max (8 ft. or as noted for I-77 Overlay) | Not greater than allowed by 155.425 et seq. | Not listed |
| Architectural Overlay District (AO) | 1 | See underlying zoning | See underlying zoning district; may be further restricted by AO or certificate of appropriateness | Not listed |
| Traditional Recreation Open Space (TROS) District | 1 | Not listed | Regulated per sign section | Not listed |
| General Regulations For All Zones | 2 | Not listed | 32 sq. ft. | Not listed |
Zone-by-Zone Sign Requirements in Blythewood(sample of 3 of 15 zones)
Rural District (RU)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign | 8 ft. | 32 sq. ft. | Not listed | 5 ft. from right-of-way, 15 ft. from lot line | One per street front, up to two per parcel | On property, minimum 5 ft. from street right-of-way, 15 ft. from adjacent lot line. | Not listed | Unlock | Chart 1, section 155.428; Chart 2, section 155.429 |
| Wall Sign | Not listed | 20 sq. ft. | Not listed | Not listed | One per building wall that fronts on a public street | Building wall | Not listed | Unlock | Chart 1, section 155.428; Chart 2, section 155.429 |
| Temporary Sign | 8 ft. | 32 sq. ft. | Not listed | Not listed | One per street front | On property, subject to event duration | Not listed | Unlock | Section 155.428(D); Chart 1, 155.428 |
Neighborhood Office District (NO), Neighborhood Commercial District (NC), Multi-Neighborhood Office District (MO), Multi-Neighborhood Commercial District (MC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign | 8 ft. | 32 sq. ft. | Not listed | 5 ft. from right-of-way, 15 ft. from adjacent lot line | 1 per street front, max 2 per parcel | Minimum 5 ft. behind right-of-way, 15 ft. from adjacent lot line, 15 ft. from residential lot if abutting. | Not listed | Unlock | Section 155.428(A)(1); Chart 1, Chart 2 |
| Wall Sign | Not listed | 20 sq. ft. | Not listed | Not listed | 1 per wall facing public street | On each building wall fronting a public street | Not listed | Unlock | Section 155.429, Chart 1 and section 155.428(B)(1)(d) |
| Projecting Sign | Not listed | 10 sq. ft. | Not listed | Not listed | See additional requirements | Projecting from building, not more than 6 ft.; min. 7 ft. clearance to ground | Not listed | Unlock | Section 155.428(A)(4) |
| Canopy/Awning Sign | Not listed | Not listed | Not listed | Not listed | Not listed | On canopy/awning | Not listed | Unlock | Section 155.428(A)(3) |
| Window Sign | Not listed | 50% of window area | Not listed | Not listed | Not listed | In window | Not listed | Unlock | Section 155.430(K) |
| Temporary Sign | 8 ft. | 32 sq. ft. | Not listed | Not listed | 1 per street front | On property; attached to structure for banners | Not listed | Unlock | Section 155.428(D) |
| Sandwich Board Sign | 3 ft. | 6 sq. ft. (3 ft. tall × 2 ft. wide) | 2 ft. | At least 5 ft outside right-of-way | 1 per business | On business lot, at least 5 ft outside right-of-way | Not listed | Unlock | Section 155.430(S) |
Town Center District (TC), Community Commercial District (CC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign | 8 ft. | 32 sq. ft. (64 sq. ft. for multiple occupancy in TC/CC) | Not listed | 5 ft. from right-of-way, 15 ft. from adjacent lot line | 1 per street front, 2 per parcel | Minimum 5 ft. behind right-of-way, 15 ft. from adjacent lot line; 15 ft. from residential lot line if abutting | Not listed | Unlock | Section 155.428(A)(1); Chart 1 |
| Wall Sign | Not listed | 20 sq. ft.; or 15% of ground floor area (TC/CC), not to exceed 20 sq. ft. | Not listed | Not listed | 1 per wall facing public street | Building wall facing public street | Not listed | Unlock | Section 155.428(B) |
| Projecting Sign | Not listed | 10 sq. ft. | Not listed | Not listed | See additional requirements | Projecting from building, not more than 6 ft.; min. 7 ft. clearance to ground | Not listed | Unlock | Section 155.428(A)(4) |
| Sandwich Board Sign | 3 ft. | 6 sq. ft. (3 ft. tall x 2 ft. wide) | 2 ft. | 5 ft. outside right-of-way | 1 per business | On business lot, at least 5 ft. outside right-of-way; during business hours only | Not listed | Unlock | Section 155.430(S) |
PermitPal covers all 15 zoning districts in Blythewood. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Blythewood
- It is unlawful to erect, construct, place, display, repair, structurally alter, enlarge, move or replace any sign without a sign permit from the zoning administrator, unless exempted.
- Placement or display of any sign on any curb, sidewalk (except where otherwise permitted), post, pole, hydrant, bridge, tree, or other surface located on, over, or across any public street or right-of-way, or on stakes on a property, is prohibited unless otherwise permitted.
- No sign shall obstruct the view of bicyclists or motorists using any street, or interfere with effectiveness of or obscure any traffic sign, device, or signal.
- Illuminated, highly reflective signs or spot lights which hamper the vision of motorists or bicyclists are prohibited.
- Signs located outdoors which interfere with free passage from or obstruct any fire escape, downspout, window, door, stairway, ladder or opening intended as a means of ingress or egress or providing light or air are prohibited.
- No sign (excluding government signs) may be intentionally placed to deny an adjoining property owner visual access to an existing sign.
- Flashing, rotating, or blinking signs, signs with flashing or reflective disks, signs with lights of changing intensity or color, or electrically scrolled messages, are prohibited.
- Roof signs are prohibited.
- Off premises signs are prohibited.
- Inflatable signs, including balloons over two feet in diameter, are prohibited.
- Video displays, electronic changeable copy signs (outside of designated overlay districts), and electronic graphic display signs are prohibited.
- Signs with no sign copy (blank signs) are prohibited.
- No sign shall be placed on a piece of property without permission of its owner or agent.
- All ground-mounted signs must be located a minimum of five feet behind the street right-of-way.
- No ground-mounted sign greater than five square feet in area may be closer than 15 feet to any adjacent lot line or to a residential district.
- Nonconforming signs may not be moved, replaced, enlarged, or have their nonconformity increased.
- If a nonconforming sign is removed, taken down, moved, or destroyed, it may only be replaced by a conforming sign.
- If a nonconforming sign remains blank for 30 days, it shall be deemed abandoned and must be removed or brought into compliance within 30 days.
- No more than one projecting sign is permitted per building frontage (with exceptions for multiple occupancy buildings, but with spacing).
- Illuminated tubing outlining property lines, open sales areas, or parking areas is prohibited, except for tubing integrated into an original architectural feature upon architectural board approval.
Exempt Signs in Blythewood
- Signs erected by or on behalf of the city, county, state, or federal government identifying streets or public property, conveying public information, and directing or regulating pedestrian or vehicular traffic.
- Memorial signs, plaques, or grave markers which are noncommercial in nature and erected by or on behalf of government entities.
- Flags, pennants, insignia, or religious symbols of any government or non-profit/non-for-profit organization, not displayed in connection with a commercial promotion or as an advertising device (with limitations on size and number per site).
- Integral decorative or architectural features of buildings, as long as they do not contain letters, trademarks, moving parts, or lights.
- On-premise directional and traffic flow signs not exceeding four square feet in area each and not exceeding the number of ingress and egress points.
- Identification signs for residential uses not exceeding four square feet in area (one per premises).
- Campaign and election signs not exceeding 20 square feet, erected no sooner than 30 days before the election and removed within seven days after.
- Temporary real estate signs advertising a specific property for sale, lease, rent, or development as specified (size and number limits, on premises, not illuminated).
- Temporary construction signs within size and contextual limits (and post-construction removal), per section requirements.
- One on-premise garage sale sign and up to two off-premise directional signs per garage sale, limited duration and size, not in right-of-way.
- Window signs proportional to scale, covering less than 50% of window area, and not obscuring vision at critical heights.
- "Warning", "No Trespassing", and similar informational signs not over four square feet.
- Signs located within a stadium intended only for persons within the stadium.
- Any sign inside a building, not attached to or placed within an external window or glass, and not legible more than three feet beyond the building.
- Signs placed on newspaper boxes designed for newspaper delivery.
- Historical plaques mounted per the US Secretary of the Interior's specifications.
- Changing or replacing sign copy on an existing lawful sign (if nature/structure isn't changed to render nonconforming); change of business does require permit.
- Inconspicuous signs (not visible externally or from public right-of-way).
- One sandwich board sign for onsite business use during operating hours; maximum three feet tall and two feet wide per face, constructed for stability, not blocking visibility, placed at least five feet outside right-of-way.
Sign Plan & Submission Notes for Blythewood
- A permit issued by the zoning administrator is required to erect, construct, enlarge, move, or replace any sign, except for those exempted by section 155.430.
- Applications for sign permits must include a sketch (dimensions, shape, proposed location) and any information required for compliance evaluation; one copy is provided post-approval/denial.
- For changeable copy signs and electronic changeable copy signs, additional restrictions and architectural review (Certificate of Appropriateness) are required in the architectural overlay district.
- Development plans, including site plans, may require a sign plan or sign package to be submitted for subdivisions or group developments, notably in the AO district (see 155.503(B)).
- Within the AO (architectural overlay) district, a Certificate of Appropriateness is required prior to issuance of a zoning or building permit for signs (and most exterior features).
- Nonconforming signs must be brought into compliance: by January 26, 2016, for general ground-mounted signs, and by January 26, 2020, for those in the I-77 sign overlay district.
- Appeals of sign permit decisions are made to the board of zoning appeals; variances may be granted by the board, except for Certificate of Appropriateness decisions by the architectural review board, which are not eligible for variance.
- Removal of signs: insecure signs, unpermitted signs, signs not conforming to International Building/Fire Codes, or signs advertising no longer active businesses must be removed by the owner per instructions from the zoning administrator.
- A sign design package is specifically required for group developments and subdivisions applying for a Certificate of Appropriateness from the architectural review board (section 155.503(B)).
- Board of Architectural Review review required for any sign in historic or AO districts, application should include complete sign plans, including material, color, placement, scale, and method of attachment.
Source: municode municipal code