Sign Regulations in Burkburnett, Texas
Burkburnett, Texas has specific sign regulations covering 29 sign types across 3 zoning districts. Regulated sign types include Awning Sign / Canopy Sign, Banner Sign (≤ 24 sf), Banner Sign (> 24 sf). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 19, 2025
Sign Regulation Overview for Burkburnett, Texas
Sample Sign Requirements in Burkburnett
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Awning Sign / Canopy Sign | — | Combined with wall sign max as per wall sign rules | — |
| Banner Sign (≤ 24 sf) | — | 24 square feet per frontage (or less) | — |
| Banner Sign (> 24 sf) | — | more than 24 square feet per frontage (limit as per wall sign percentage, see wall sign limits) | — |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
29
- Awning Sign / Canopy Sign
- Banner Sign (≤ 24 sf)
- Banner Sign (> 24 sf)
- Monument Sign
- +2 more types
Zoning Districts
3
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Other Cities in Texas
Frequently Asked Questions
Sign height limits in Burkburnett vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.
To get a sign permit in Burkburnett, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Burkburnett, regulated sign types include Awning Sign / Canopy Sign, Banner Sign (≤ 24 sf), Banner Sign (> 24 sf), Monument Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Burkburnett vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Burkburnett are regulated with specific requirements for brightness, animation, and message duration. Burkburnett has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Burkburnett Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Burkburnett, Texas sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Burkburnett, Texas Sign Rules at a Glance
Burkburnett, Texas regulates 29 sign types across 3 zoning districts. Flags in the General Regulations For All Zones zoning district are capped at Flagpole max 20 feet, or height of adjacent building up to 50 feet tall and Flag length less than 1/3 of flagpole height, with a See flagpole property line limit setback (Sec. § 99.15(G)(6)). Most commercial signs in Burkburnett require a permit.
Detailed Sign Ordinance Requirements for Burkburnett, Texas
Sign Rules by Zoning District in Burkburnett (3 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 23 | Flagpole max 20 feet, or height of adjacent building up to 50 feet | 150 square feet per side | — |
| Residential | 6 | 8 feet | 32 square feet | — |
| Commercial | 10 | 15 feet (60 feet if CSLAP permit for regulated highway) | 150 square feet per side | — |
Zone-by-Zone Sign Requirements in Burkburnett
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Construction Sign | 10 feet above grade | 32 square feet | — | — | One per lot/frontage | On-premises construction site | — | Unlock | § 99.15(G)(3) |
| Development Sign | 10 feet above grade | 32 square feet | — | — | 1 per 50 lots, up to 32 | At development site | — | Unlock | § 99.15(G)(4) |
| Flag | Flagpole max 20 feet, or height of adjacent building up to 50 feet | Flag length less than 1/3 of flagpole height | — | See flagpole property line limit | — | Private property. | — | Unlock | § 99.15(G)(6) |
| Monument Sign | 15 feet (except up to 60 feet for commercial signs with CSLAP permit) | 150 square feet per side | — | — | 1 per lot per frontage (+ menu/directional exceptions) | On-premises; one per lot per frontage. | — | Unlock | § 99.15(G)(8) |
| Pylon Sign | 15 feet | 150 square feet per side | — | — | 1 per lot per frontage; exceptions for menu/directional. | On-premises; one per lot per frontage. | — | Unlock | § 99.15(G)(12) |
| Real Estate Sign (Commercial, Freestanding) | 10 feet | 32 square feet | — | — | One per building or tenant space per frontage | At site for sale/lease | — | Unlock | § 99.15(G)(13)(b)(1)-(4) |
| Subdivision Entry Sign (Primary Entrance) | 8 feet | 32 square feet | — | — | Max two per primary entrance | Within subdivision, within 150 feet of entrance | — | Unlock | § 99.15(G)(14)(a) |
| Subdivision Entry Sign (Secondary Entrance) | 8 feet | 16 square feet | — | — | Max two per secondary entrance | Within subdivision, within 150 feet of entrance | — | Unlock | § 99.15(G)(14)(b) |
Residential
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| No Smoking Sign | — | — | — | — | At each entrance and place where required | At each entrance to public place/workplace; elsewhere as needed | — | Unlock | § 102.06 |
| Vicious Dog Warning Sign | — | — | — | — | At least one per premises | Premises with a vicious dog | — | Unlock | § 91.48 |
| Nameplate Sign (Residential) | — | 2 square feet | — | — | One per residence | On premises | — | Unlock | § 99.15(B)(12) |
| Subdivision Entry Sign (Primary Entrance) | 8 feet | 32 square feet | — | — | Max two per primary entrance | Within subdivision, within 150 feet of the primary entrance | — | Unlock | § 99.15(G)(14)(a) |
| Subdivision Entry Sign (Secondary Entrance) | 8 feet | 16 square feet | — | — | Max two per secondary entrance | Within subdivision, within 150 feet of the secondary entrance | — | Unlock | § 99.15(G)(14)(b) |
| Real Estate Sign (Residential) | — | 8 square feet | — | — | One per frontage | At site for sale/lease | — | Unlock | § 99.15(G)(13)(a) |
Commercial
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | — | 20% of wall area, up to 500 square feet | — | — | — | Parallel on exterior wall | — | Unlock | § 99.15(G)(15) |
| Awning Sign / Canopy Sign | — | See wall sign limit | — | — | One per tenant per frontage | On building or on detached accessory island canopy | — | Unlock | § 99.15(G)(1) |
| Banner Sign (> 24 sf) | — | More than 24 square feet per frontage (limited by wall sign %) | — | — | Max 5 permits per year (per business) | On-premises only. | — | Unlock | § 99.15(G)(2)(b)-(d) |
| Freestanding Commercial Real Estate Sign | 10 feet | 32 square feet | — | — | One per building/tenant space per frontage | At site for sale/lease | — | Unlock | § 99.15(G)(13)(b)(1)-(4) |
| Wall-Mounted Commercial Real Estate Sign | — | 10 square feet | — | — | One per building/tenant space per frontage | Wall of building for sale/lease | — | Unlock | § 99.15(G)(13)(b)(3)-(4) |
| Monument Sign | 15 feet (60 feet if CSLAP permit for regulated highway) | 150 square feet per side | — | — | 1 per lot per frontage | On-premises; one per lot per frontage. | — | Unlock | § 99.15(G)(8) |
| Pylon Sign | 15 feet | 150 square feet per side | — | — | 1 per lot per frontage | On-premises; one per lot per frontage. | — | Unlock | § 99.15(G)(12) |
| Projecting Sign | — | 48 square feet | — | — | One per tenant per frontage (possible exception for above and below awning) | On wall, projects from building | — | Unlock | § 99.15(G)(11) |
Illumination rules, size formulas, and permit requirements for every sign type in Burkburnett are available with a free PermitPal account.
Start freeProhibited Signs in Burkburnett
- No unauthorized sign may be placed, maintained, or displayed upon or in view of any highway, street, or alley that purports to imitate, resemble, or hide from view any official traffic-control device or railroad sign or signal.
- No traffic sign or signal bearing any commercial advertising shall be placed or maintained upon any highway, street, or alley.
- It is prohibited to erect, construct, install, paint, or replace a sign without first obtaining a permit, unless the sign falls under enumerated exemptions.
- The following types of signs are prohibited: air blown signs, billboard signs (within city limits), bandit signs, bench signs, pole signs, roof signs, any sign with revolving beacons, fluttering, swinging, or otherwise moving parts (except as specified), signs which imitate or resemble any official traffic sign, signal, or device, signs that interfere with effectiveness of or obscure official traffic sign, device, or signal, signs placed on a vehicle or trailer for primary purpose of display, signs placed in the right-of-way of any road or highway maintained by the city or state highway system, and any sign placed in violation of Chapter 393 of the Texas Transportation Code unless specifically permitted.
- Any sign more than 20 feet in height must have plans sealed by a licensed architect or engineer; signs under 20 feet may require sealed plans at the Director's discretion.
- No sign shall project into any public right-of-way except as allowed by ordinance or the International Building Code.
- Temporary signs may not be illuminated, have moving elements, exceed 36 square feet, or have a height greater than eight feet.
- No illuminated sign may be lit by flashing, intermittent, or moving lights, or include audio, pyrotechnic, bluetooth advertising components, or static images projected onto stationary objects.
- Nonconforming signs may not be altered to increase nonconformity, and must be removed if substantially damaged (cost to repair exceeds 60% of replacement value), or determined to be a hazard or substandard.
- Signs must not be placed on utility poles, street signs, stop signs, traffic control devices, or in the public right-of-way.
- Any sign not maintained in good repair may be ordered removed at the owner's expense.
- Community sign at 735 Davey Drive may not be used for commercial advertising or to advertise/promote political candidates, political parties, or political issues.
- It is not a defense that an operator failed to post a required sign.
Exempt Signs in Burkburnett
- Permits are not required for signs being repainted where painting is the only alteration.
- Permits are not required for on-premises signs posted on private property on maximum 24-inch by 30-inch sheet poster panels.
- All signs erected by governmental entities for the purpose of public instruction, street or highway designation, control of traffic, and similar uses related to public interest are exempt from permit requirements.
- Permits are not required for garage and yard sale signs no larger than four square feet.
- Permits are not required for construction, development, or real estate signs placed on private property and in compliance with the ordinance.
- Permits are not required for replacement of plastic sign faces or panels where the original frame is used, and neither frame size nor substructure are altered or removed.
- Permits are not required for replacement of bulbs that illuminate the sign where the original or identical frame is used, and neither frame size nor substructure are altered or removed.
- Permits are not required for directional signs placed on private property and in compliance with the ordinance.
- Flutter flags placed on private property and otherwise in compliance with the ordinance are exempt from the permit requirement.
- Permits are not required for portable signs for on-premises advertising not exceeding 12 square feet in area.
- Permits are not required for banner signs for on-premises advertising not exceeding 24 square feet in area.
- Permits are not required for nameplate signs for residential locations not exceeding two square feet in area.
- Permits are not required for contractor signs identifying a contractor or subcontractor performing work on the premises, not exceeding six square feet and removed when work is completed.
- Permits are not required for professional nameplates and occupational signs, attached to the building face in commercial/public institutional buildings, denoting only name and occupation and not exceeding four square feet.
- Permits are not required for temporary political signs placed on private property in compliance with Texas Election Code Section 259.003 and the ordinance.
- All signs in existence and in compliance with zoning regulations as of the effective date of the ordinance are exempt from new provisions, except that alterations must comply.
Sign Plan & Submission Notes for Burkburnett
- An application for a sign permit must include scaled and/or dimensioned plans of the sign(s), a site plan showing location relative to property lines, easements, setbacks, buildings, and other structures, plus a sign elevation and mock-up of sign face.
- For any sign more than 20 feet in height, plans must be sealed by an architect or engineer licensed to practice in the state; for shorter signs, sealed plans may be required at the Director's discretion.
- For subdivision entry signs, elevation drawings must be submitted for staff review prior to issuance of a building permit, showing construction materials and detail.
- The owner of property may request a special use review (special use permit) for size and height restrictions for monument or pylon signs.
- Conversion of an existing billboard sign to an electronic changeable copy sign requires a special use permit granted by the Board of Commissioners.
- Community sign use at 735 Davey Drive requires a written application submitted to the City Clerk and approval by the City Manager or designee.