Sign Regulations in Colleyville, Texas
Colleyville, Texas has specific sign regulations covering 32 sign types across 6 zoning districts. Regulated sign types include Subdivision Monument Sign, Traffic Directional Sign, Subdivision Wall Sign or Plaque. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Sign Regulation Overview for Colleyville, Texas
Sample Sign Requirements in Colleyville
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Subdivision Monument Sign | 6.5 ft. | 45 sq. ft. | Front: 0 ft. | Side: 0 ft. (Signs on an island must allow for appropriate driver visibility) |
| Subdivision Wall Sign or Plaque | — | 30 sq. ft. | — |
| Institutional Sign (On-premises) | 5.5 ft. | 60.5 sq. ft. | Front: 8 ft. from right-of-way | 12 ft. from pavement | 30 ft. side/rear from other property |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
32
- Subdivision Monument Sign
- Traffic Directional Sign
- Subdivision Wall Sign or Plaque
- Institutional Sign (On-premises)
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Colleyville
Other Cities in Texas
Frequently Asked Questions
In Colleyville, monument signs are limited to 6.5 ft.. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.
To get a sign permit in Colleyville, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Colleyville, regulated sign types include Subdivision Monument Sign, Traffic Directional Sign, Subdivision Wall Sign or Plaque, Institutional Sign (On-premises), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
In Colleyville, monument signs typically require a Front: 0 ft. | Side: 0 ft. (Signs on an island must allow for appropriate driver visibility) setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.
Digital and LED signs in Colleyville are regulated with specific requirements for brightness, animation, and message duration. Colleyville has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Colleyville Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Colleyville, Texas sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Colleyville, Texas Sign Rules at a Glance
Colleyville, Texas regulates 32 sign types across 6 zoning districts. Subdivision Monument Signs in the AG Agricultural District, RE Single-Family Estate Residential District, R-40 Single-Family Residential District, R-30 Single-Family Residential District, R-20 Single-Family Residential District, R-15 Single-Family Residential District, RD Two-Family Residential District, MH Mobile Home Residential District zoning district are capped at 6.5 ft. tall and 45 sq. ft., with a 0 ft. (Signs on an island must allow for appropriate driver visibility) setback (Sec. Sec 7.150.D, Table 7-1, Table 7-2). Most commercial signs in Colleyville require a permit.
Detailed Sign Ordinance Requirements for Colleyville, Texas
Sign Rules by Zoning District in Colleyville (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| AG Agricultural District, RE Single-Family Estate Residential District, R-40 Single-Family Residential District, R-30 Single-Family Residential District, R-20 Single-Family Residential District, R-15 Single-Family Residential District, RD Two-Family Residential District, MH Mobile Home Residential District | 11 | 30 inches | 60.5 sq. ft. | — |
| RMF Multi-Family Residential District | 6 | 30 in. | 60.5 sq. ft. | — |
| CPO Professional Office Commercial District, CN Neighborhood Commercial District | 9 | 10 ft. | 64 sq. ft. | — |
| CC-1 Village Retail District, CC-2 Shopping Center District, CC-3 Highway Commercial District, ML Light Manufacturing District | 7 | 35 ft. | 250 sq. ft. | — |
| PUD-R Planned Unit Development - Residential, PUD-C Planned Unit Development - Commercial, PUD Planned Unit Development | 3 | 6.5 ft. | 60.5 sq. ft. | — |
| General Regulations For All Zones | 4 | 10 ft. | 64 sq. ft. | — |
Zone-by-Zone Sign Requirements in Colleyville(sample of 3 of 6 zones)
AG Agricultural District, RE Single-Family Estate Residential District, R-40 Single-Family Residential District, R-30 Single-Family Residential District, R-20 Single-Family Residential District, R-15 Single-Family Residential District, RD Two-Family Residential District, MH Mobile Home Residential District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Subdivision Monument Sign | 6.5 ft. | 45 sq. ft. | — | Front: 0 ft. | Side: 0 ft. (Signs on an island must allow for appropriate driver visibility) | 2 per entrance | Subdivision main entrance; not within public right-of-way unless joint use agreement with the City | — | Unlock | Sec 7.150.D, Table 7-1, Table 7-2 |
| Institutional Sign (On-premises) | 5.5 ft. | 60.5 sq. ft. | — | Front: 8 ft. from right-of-way | 12 ft. from pavement | 30 ft. side/rear from other property | 1 per street frontage | On premises of institution; one per street frontage | — | Unlock | Sec 7.150.B, Table 7-1, Table 7-2 |
| Traffic Directional Sign | 30 inches | 6 sq. ft. | — | None required | 2 per curb cut | At or near institutional/commercial entrances or exits | — | Unlock | Sec 7.150.E, Table 7-1, Table 7-2 |
| Residential Real Estate Sign | 6 ft. | 12 sq. ft. | — | None required | 1 per property | On property for sale/rent/lease | — | Unlock | Sec 7.190.J, Table 7-4, Table 7-5 |
| Garage Sale Sign (Single-family) | 4 ft. | 8 sq. ft. | — | None required | 1 per frontage (up to 2 per subdivision entrance for HOA events) | On premises; also allowed at subdivision entrance for HOA events | — | Unlock | Sec 7.190.D, Table 7-4, Table 7-5 |
| Garage Sale Sign (Neighborhood-wide) | 6 ft. | 32 sq. ft. | — | None required | 2 per subdivision entrance | On private property or right-of-way within HOA limits | — | Unlock | Sec 7.190.D, Table 7-4, Table 7-5 |
| Model Home Sign | 6 ft. | 32 sq. ft. | — | None required | 1 per premises | On model home lot in residential development | — | Unlock | Sec 7.190.G, Table 7-4, Table 7-5 |
| Traffic Directional Sign (Institutional uses) | 30 in. | 6 sq. ft. | — | None | 2 per curb cut | Entrance/exit of institution or business | — | Unlock | Sec 7.150.E, Table 7-1, Table 7-2, Table 7-4 |
CPO Professional Office Commercial District, CN Neighborhood Commercial District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| General Business Monument Sign | 5.5 ft. | 60.5 sq. ft. | — | Front: 8 ft. | Side/rear: 30 ft. | 1 per 250 ft. frontage | At front of lot; 8 ft. from front right-of-way, 12 ft. from edge of pavement, 30 ft. side/rear property line | — | Unlock | Sec 7.150.A, Table 7-1, Table 7-2, Table 7-3 |
| Wall Sign | 6 ft. (cannot extend above wall) | See formula | 75% of wall width (sum is 75% if multiple wall signs on one wall) | — | — | On exterior wall facing frontage | — | Unlock | Sec 7.175.D, Table 7-3 |
| Awning Sign | 6 ft. max awning height | 20% of awning area, max 50% of awning length or 10 ft (whichever is less) | — | — | — | On awning facing public street/parking | — | Unlock | Sec 7.175.A, Table 7-3 |
| Projecting Sign | — | 20 sq. ft. | — | — | 1 per tenant (in lieu of wall sign on same wall) | Projecting from building wall (max 4 ft from wall, min 2 ft from curb); min 8 ft above walking surface, 14 ft above vehicular area, not above roofline | — | Unlock | Sec 7.175.C, Table 7-3 |
| Directory Sign | 6.5 ft. | 25 sq. ft. | — | 150 ft. from street | 1 per entrance, max 4 | 1 per internal drive/entrance, max 4 per center | — | Unlock | Sec 7.150.F, Table 7-1, Table 7-2 |
| Temporary Business Sign (Flexible Banner/A-frame/Stake Sign) | Flexible Banner: 6 ft.; A-Frame: 6 ft. (yard)/4 ft. (sidewalk); Stake: 6 ft. | Flexible Banner: 50 sq. ft.; A-Frame: 24 sq. ft. (yard) or 8 sq. ft. (sidewalk); Stake: 16 sq. ft. | — | None | 1 per business tenant/occupant | On business premises; A-frame may be on sidewalk if 4 ft. clearance maintained | — | Unlock | Sec 7.190.K, Table 7-5 |
| Commercial Real Estate Sign | 10 ft. | 64 sq. ft. | — | None | 1 per property | On commercial property for sale/rent/lease | — | Unlock | Sec 7.190.I, Table 7-5 |
| Subdivision Monument and Wall Signs (if part of mixed-use PUD, or per plat) | Monument: 6.5 ft.; Wall: per wall height | Monument: 45 sq. ft.; Wall: 30 sq. ft. | — | Monument: 0 ft. | Monument: 2 per entrance; Wall: 2 per entryway | Subdivision entrance or perimeter wall | — | Unlock | Sec 7.150.D, 7.175.E |
CC-1 Village Retail District, CC-2 Shopping Center District, CC-3 Highway Commercial District, ML Light Manufacturing District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| General Business Monument Sign | 5.5 ft. | 60.5 sq. ft. | — | Front: 8 ft. | Side/rear: 30 ft. | 1 per 250 ft. | 8 ft. from right-of-way, 12 ft. from pavement, 30 ft. side/rear property lines | — | Unlock | Sec 7.150.A, Table 7-1, Table 7-2, Table 7-3 |
| Directory Sign | 6.5 ft. | 25 sq. ft. | — | 150 ft. from street | 1 per entrance, max 4 | Internal drive or street; 1 per entrance, max 4 per site; 150 ft. from street | — | Unlock | Sec 7.150.F, Table 7-1, Table 7-2 |
| Major Shopping Center Landmark Sign | 30 ft. | Effective area of signage: 5 ft. height × 10 ft. width for tenant area; 14 ft. × 14 ft. max base; 30 ft. max height | 14 ft. base max | — | — | Within shopping center area; subject to specific plan/permit | — | Unlock | Sec 7.155.B, 7.210.B |
| Wall Sign, Awning Sign, Canopy Sign, Projecting Sign | — | — | — | — | — | — | — | Unlock | Sec 7.175, Table 7-3 |
| Freeway Pole Sign (CC-2, CC-3, ML only, and only in Freeway Overlay Zone) | 35 ft. | 250 sq. ft. | — | Front: 8 ft. | Side: 30 ft. | 1 per lot | Within 250 ft. of Hwy 121 right-of-way | — | Unlock | Sec 7.155.A, Table 7-2, Table 7-1 |
| Traffic Directional Sign | 30 in. | 6 sq. ft. | — | None | 2 per curb cut | At entrances/exits | — | Unlock | Sec 7.150.E, Table 7-2 |
| Commercial Real Estate, Temporary Business, Political, Garage Sale Signs | — | — | — | — | — | — | — | Unlock | Sec 7.190.I-K |
PermitPal covers all 6 zoning districts in Colleyville — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 6 zones for Colleyville — start freeProhibited Signs in Colleyville
- No person, firm, or corporation shall erect a new sign, or alter an existing sign, or sign structure, unless said sign conforms to the provisions of this Chapter.
- No sign shall exceed the maximum area provided for in this Chapter.
- All signs shall be located on the same premises where the product or merchandise being advertised is located, except where a specific provision allows off-premises advertising.
- No sign shall exceed the maximum height provided for in this Chapter, and grade shall not be artificially altered by more than 18 inches to increase sign height.
- All permanent signs must be designed and constructed to withstand a wind pressure of not less than 35 pounds per square foot of area.
- It is unlawful for any person, firm, or corporation to erect permanent signs without valid registration with the City.
- All sign construction must comply with structural requirements of the Building Code; any electrical installations must comply with Electrical Code; no unfinished metal allowed on exterior surfaces.
- No sign shall be erected in, extend into, or over, a public right-of-way, except where permitted or upon approval of a Right-of-Way Encroachment Agreement.
- No sign shall be erected in such a manner that interferes with access to or from fire escapes, exits, standpipes, windows, ventilators, or doors.
- Illuminated signs in residential districts are prohibited except where specifically allowed; sign illumination must not produce glare across property lines and must meet nit intensity limits for electronic message signs.
- No sign may reduce the required number of parking spaces.
- Signs must comply with this code unless an adopted PUD or SUP ordinance specifically authorizes variation.
- No sign may be erected, relocated, enlarged, or replaced without a permit (unless specifically exempted), and no permit shall be issued absent code compliance.
- Permit for a sign is only valid for 180 days from issuance, unless otherwise specified.
- Failure to remove a temporary sign by the deadline constitutes a violation.
- Sign Board of Appeals may deny a variance request for failure to pay all applicable fees.
- Off-premises signs including billboards are prohibited, except where specifically allowed.
- Obscene, indecent, or immoral matter on signs is prohibited.
- Portable signs (such as windsail style signs, flags, pennants, signs attached to trailers or mobile structures) are prohibited except as allowed by a grand opening permit.
- Roof signs (mounted on roofs or above parapet) are prohibited.
- No sign may be painted, marked, or attached to streets, curbs, sidewalks, utility poles, fences, or public buildings, except as allowed.
- No sign may be attached to fences or utility poles except as allowed for small fence company signs.
- Animated, moving, or flashing signs are prohibited.
- Balloons, flags, pennants, and inflatable advertising are prohibited except as allowed by a grand opening sign permit.
- Signs that obstruct the view of traffic, simulate traffic control devices, or otherwise interfere with traffic or pedestrian safety are prohibited.
- No sign not specifically allowed by this Chapter may be erected or displayed.
Exempt Signs in Colleyville
- Any sign erected by or under the authority of the City of Colleyville on City property.
- Street identification signs, public notices, and warning signs installed by City, County, State or Federal agency.
- Residential nameplates or subdivision identification plaques attached to a perimeter screening wall not exceeding two (2) square feet in area.
- Historical markers placed by city, county, state, or national historical preservation organizations.
- Official vehicle inspection station signs, holiday lights and decorations, or works of art.
- Signs located on-premises or inside a building and not legible from a public street (e.g., credit card decals, hours of operation, emergency contact info, barber poles).
- On-site traffic control signs on commercial properties (e.g., stop, yield) with no commercial message.
- "No Parking" or "Towing" signs authorized by City Ordinance.
- "No Dumping Allowed" signs posted to deter illegal dumping.
- Underground utility warning signs not exceeding one (1) square foot and similar safety signs.
- Signs on railway property referencing operation of such railway.
- Security Warning, Neighborhood Watch, or Crime Watch signs under two (2) square feet.
- Flags, emblems, and insignia of any governmental body.
- Corporate flags displayed on a freestanding pole not exceeding 35 feet in height and 32 square feet in area, with required setback.
- Drive-through menu boards not located in front of the building.
- Scoreboards, including the identification of donors.
Sign Plan & Submission Notes for Colleyville
- Sign plan (Master Sign Plan) is not referenced in the general code as a requirement for all signs; however, Sec 7.130.C states every sign permit application must provide sufficient plans to allow determination of compliance with the code as required by the administrative official.
- Sec. 3.31 Site Plan Approval: For nonresidential properties zoned CPO, CN, CC, ML, SU, PUD-C, or PUD-I, a site plan must be submitted prior to permit issuance; this site plan must include the location, size, and arrangement of all outdoor signs, exterior auditory speakers, and lighting.
- Sign regulations allow PUD or SUP ordinances to contain alternative sign requirements (Sec. 7.130.L).
- For Major Multi-Tenant Shopping Centers, City Council approval of a permit and sign plan is required for landmark signs and entry-wall signs (Sec. 7.155.B.4).
- For the Freeway Overlay Zone (adjacent to Hwy 121), a City Council approved permit is required for Freeway Pole Signs (Sec. 7.155.A.1.a).
- Variances from sign code sign requirements may be requested using the Sign Board of Appeals process outlined in Ch. 1, Sec. 1.15 and Ch. 7, Sec. 7.110.
- When an application is made for a site plan for a nonresidential property, the sign location, size, and arrangement must be included in the application (Sec 3.31.C.8).
Source: municode municipal code