Northlake, Texas has specific sign regulations covering 11 sign types across 6 zoning districts. Regulated sign types include Wall Sign (Primary), Wall Sign (Secondary), Window Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 9, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Northlake, Texas
Sample Sign Requirements in Northlake
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign (Primary) | Varies by building height | Varies by building height and width | Not listed |
| Wall Sign (Secondary) | Not listed | 10% of Primary Wall Sign area | Not listed |
| Window Sign | Not listed | 25% of window area | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
11
- Wall Sign (Primary)
- Wall Sign (Secondary)
- Window Sign
- Monument Sign
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Other Cities in Texas
Frequently Asked Questions
In Northlake, the height limit for Monument Sign is 8 feet (Sec. 11.18.50). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Northlake require a permit. From the submission notes on this page: A Unified Sign Development Plan required of certain signs specified in this section, or as otherwise required herein, shall be submitted to the town. Run a code check for an exact address to see the permit requirements for that zone.
Northlake's sign code covers 11 sign types, including Wall Sign (Primary), Wall Sign (Secondary), Window Sign, and Monument Sign. Most commercial signs need a permit. The ordinance lists 21 exemptions. One of them: A sign permit is not required for agricultural signs identifying a farm or ranch. The full list is on this page.
This page doesn't list a single setback distance for signs in Northlake. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Northlake's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.
Ready to Research Northlake Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Northlake, Texas, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Northlake, Texas Sign Rules at a Glance
Northlake, Texas regulates 11 sign types across 6 zoning districts. A-Frame Signs in the Planned Development zoning districts are capped at 4 feet tall, 12 square feet, and 3 feet wide (Sec. 11.18.1). Most commercial signs in Northlake require a permit.
Detailed Sign Ordinance Requirements for Northlake, Texas
Sign Rules by Zoning District in Northlake (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 5 | 8 feet | 60 square feet | Not listed |
| Planned Development zoning districts | 1 | 4 feet | 12 square feet | Not listed |
| nonresidential zoning district | 2 | 6 feet | 60 square feet | Not listed |
| nonresidential zoning districts | 1 | 30 feet | Banner max area 48 square feet | Not listed |
| residential zoning district | 1 | 5 feet | 48 square feet | Not listed |
| nonresidential zoned property | 1 | Varies by street classification | Varies by street classification | Not listed |
Zone-by-Zone Sign Requirements in Northlake(sample of 3 of 6 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (Primary) | Varies by building height | Varies by building height and width | Not listed | Not listed | Varies by building width | Nonresidential use or zoning district | Not listed | Unlock | § 11.18.103 |
| Wall Sign (Secondary) | Not listed | 10% of Primary Wall Sign area | Not listed | Not listed | 1 per elevation | Nonresidential use or zoning district | Not listed | Unlock | § 11.18.104 |
| Window Sign | Not listed | 25% of window area | Not listed | Not listed | Not listed | Inside or exterior of a window | Not listed | Unlock | § 11.18.106 |
| Monument Sign | 8 feet | 60 square feet | Not listed | 5' front yard, height for side/rear | 1 per street frontage | Nonresidential zoning districts or areas | Not listed | Unlock | § 11.18.50 |
| Pole/Pylon Sign | Varies by street classification | Varies by street classification | Not listed | 5' front yard, 10% of lot width for side/rear | Varies by street classification | Nonresidential zoning districts | Not listed | Unlock | § 11.18.67 |
Planned Development zoning districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| A-Frame Sign | 4 feet | 12 square feet | 3 feet | Not listed | 1 per business or tenant | Sidewalk or adjacent to sidewalk | Not listed | Unlock | § 11.18.1 |
nonresidential zoning district
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | 4 feet | Not listed | 75% of awning length | Not listed | Not listed | Nonresidential use or zoning district | Not listed | Unlock | § 11.18.7 |
| Menu Board Sign | 6 feet | 60 square feet | Not listed | 25' front building setback | 1 per drive-thru use | Nonresidential use or zoning district | Not listed | Unlock | § 11.18.46 |
PermitPal covers all 6 zoning districts in Northlake. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Northlake
- No sign shall be attached in any manner to any fire escape or to the supporting members of any fire escape.
- No sign shall be erected nearer than two (2') feet from any telephone cable, power line or any streetlight standard.
- No sign shall be erected to block, partially block, or interfere in any way with a required means of exit from any building nor with any window.
- No sign shall block, interfere, or otherwise hinder pedestrian or vehicular traffic on a public sidewalk, a public thoroughfare, a fire lane easement, or a driveway required to access parking.
- Signs constructed of glass or other materials which may shatter upon impact are prohibited over a public right-of-way or pedestrian area.
- All prohibited signs or noncompliant signs shall be considered a public nuisance and are prohibited by this Article in the Town.
- Abandoned signs and neglected signs shall be considered a public nuisance and are prohibited by this Article.
- Off-location and off-premises signs are prohibited in the Town Limits.
- Portable Signs are prohibited in the town except as specifically allowed by this Article.
- Wind devices are prohibited in the town.
- Roof signs are prohibited in the town.
- Revolving signs are prohibited in the town.
- Parkway Signs are prohibited within the Town of Northlake.
- Moving signs, and/or any sign appendage that moves, are prohibited in the town.
- Merchandise Signs and/or Displays are prohibited within the town, except as specifically allowed by any town ordinance or required by Federal or State law.
- Balloons and all Other Floating Device(s) are prohibited in the town.
- Cloud Buster Balloons, blimps, and other Air Devices are prohibited in the Town of Northlake.
- Audible Signs are prohibited in the town.
- Neglected signs are prohibited in the town.
- Vacant building signage is prohibited in the town.
Exempt Signs in Northlake
- A sign permit is not required for agricultural signs identifying a farm or ranch.
- No sign permit required for gasoline price signs permanently affixed to pump islands not exceeding twelve (12) square feet.
- No sign permit required for Government Awareness Signs.
- No sign permit required for Government Community Event Signs.
- No sign permit required for Memorial Signs.
- No sign permit required for Scoreboards.
- No sign permit required for Name Signs.
- No sign permit required for Warning Signs.
- No sign permit required for Internal Signs.
- No sign permit required for Instructional/Informational Signs.
- No sign permit required for Political Signs.
- No sign permit required for Vehicle Signs.
- No sign permit required for Vending Machine Signs.
- No sign permit required for Yard Signs.
- No sign permit required for Temporary Religious Signs.
- No sign permit required for Open House Residential Signs.
- No sign permit required for Garage Sale Signs.
- No sign permit required for Home Improvement Signs.
- No sign permit required for Human Signs.
- No sign permit required for Holiday Decorations.
- No sign permit required for School Signs.
Sign Plan & Submission Notes for Northlake
- A Unified Sign Development Plan is required to be prepared for variance requests.
- A Unified Sign Development Plan is also required prior to the issuance of a sign permit for certain signs specified in this section.
- A Unified Sign Development Plan required of certain signs specified in this section, or as otherwise required herein, shall be submitted to the town.
- The Unified Development Sign Plan will be reviewed in accordance with the town's development review schedule.
- The Planning and Zoning Commission shall make a recommendation to the Town Council.
- The Town Council may approve or deny the Unified Development Sign Plan.