Questions? Call us at (262) 218-2915

Sign Regulations in Selma, Texas

Selma, Texas has specific sign regulations covering 12 sign types across 3 zoning districts. Regulated sign types include Wall Sign, Freestanding Sign (Ground Sign), Projecting Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Selma, Texas

Sample Sign Requirements in Selma

Sign TypeMax HeightMax AreaSetback
Wall SignCannot project above roofline or top of parapet, except: (single-story buildings only, wall-mounted, up to 16 ft to top of sign, may project above parapet up to 33 1/3% of sign height).Category A: 350 sq ft; Category B: 250 sq ft; Category C: 200 sq ft; minimum for each tenant: 75 sq ft, but not more than 26% of facing wall (if Category A)Not listed
Freestanding Sign (Ground Sign)16 ft or 2/3 of building height, whichever is lessSee formula. Max area per sign up to 200 sq ft per face; total may be combined if multiple allowed signs (max area = 0.5 sq ft/linear ft of frontage, up to 200 sq ft per face)Subject to map/zone setbacks except as specified; in front/street side yards, subject to area percentages in Table 2; not within rear or interior side yards.
Projecting SignMay not extend above roofline at wall/parapet except: only on single-story building, no more than 2 ft above parapet, max height to top = 16 ft, max projection above parapet = 33.3% of sign height.See formula; max 100 sq ft per face (on >60 ft ROW, 50+ mph); if used with ground sign, area of both is reduced to 1/2 of allowed area (Table 1/Table 4)Not listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for SelmaFull Coverage

Sign Types Covered

12

  • Wall Sign
  • Freestanding Sign (Ground Sign)
  • Projecting Sign
  • Portable Sign (Electric/Non-Electric)
  • +2 more types

Zoning Districts

3

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Selma

City WebsiteMunicipal Code4 permit application links available

Frequently Asked Questions

In Selma, the height limit for Commercial Sign (Ground/Freestanding, Wall, or Projecting allowed if permitted in underlying zone) in the IH 35 Overlay District is 50 ft (commercial ground sign, within 150 ft of IH 35, per Sec. 74-223) (Sec. 74-221-74-225). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Selma require a permit. From the submission notes on this page: A comprehensive sign plan may be submitted in lieu of standard sign regulations for planned commercial and industrial developments (including new and existing in any commercial or industrial zone), or planned industrial developments with at least six leaseholds. Run a code check for an exact address to see the permit requirements for that zone.

Selma's sign code covers 12 sign types, including Wall Sign, Freestanding Sign (Ground Sign), Projecting Sign, and Portable Sign (Electric/Non-Electric). Most commercial signs need a permit. The ordinance lists 14 exemptions. One of them: Religious symbols. The full list is on this page.

In Selma, Automatic Changing or Changeable Electronic Variable Message Sign (CEVMS) must be set back 25 ft from any side property lot line (Sec. 74-431). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Selma's sign ordinance that cover digital, changing, or flashing signs: No portable sign permit may be issued if the sign exceeds certain size/height, has beacons or certain flashing/blinking lights, or is missing bulbs exposing electric sockets. Automatic changing and changeable electronic variable message signs may not use sound. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Selma Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Selma, Texas, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Selma, Texas Sign Rules at a Glance

Selma, Texas regulates 12 sign types across 3 zoning districts. Temporary Construction Site Signs are capped at 16 ft tall and 160 sq ft (Sec. 74-461). Most commercial signs in Selma require a permit.

Detailed Sign Ordinance Requirements for Selma, Texas

Sign Rules by Zoning District in Selma (3 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones11Cannot project above roofline or top of parapet, except: (single-story buildings only, wall-mounted, up to 16 ft to top of sign, may project above parapet up to 33 1/3% of sign height).Category A: 350 sq ft; Category B: 250 sq ft; Category C: 200 sq ft; minimum for each tenant: 75 sq ft, but not more than 26% of facing wall (if Category A)Not listed
IH 35 Overlay District150 ft (commercial ground sign, within 150 ft of IH 35, per Sec. 74-223)200 sq ft per side (gross face area)Not listed
Industrial Zone (LI), Commercial Zone (C-1, C-2)3See General RegulationsSee General RegulationsNot listed

Zone-by-Zone Sign Requirements in Selma

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignCannot project above roofline or top of parapet, except: (single-story buildings only, wall-mounted, up to 16 ft to top of sign, may project above parapet up to 33 1/3% of sign height).Category A: 350 sq ft; Category B: 250 sq ft; Category C: 200 sq ft; minimum for each tenant: 75 sq ft, but not more than 26% of facing wall (if Category A)Not listedNot listedNot listedAffixed to building or structure with exposed face parallel or nearly parallel to building. Can use allowed wall sign area on non-frontage walls.Not listedUnlock74-291; Table 3; 74-192; 74-81; 74-291(g); 74-193
Freestanding Sign (Ground Sign)16 ft or 2/3 of building height, whichever is lessSee formula. Max area per sign up to 200 sq ft per face; total may be combined if multiple allowed signs (max area = 0.5 sq ft/linear ft of frontage, up to 200 sq ft per face)Not listedSubject to map/zone setbacks except as specified; in front/street side yards, subject to area percentages in Table 2; not within rear or interior side yards.One per premises per frontage; >250 ft frontage additional signs allowedOn private property along frontage used to determine allowance; not allowed in rear or interior side yards. Ground signs may project over public ROW per Table 5 size limits.Not listedUnlock74-271; Table 1; Table 2; 74-193
Projecting SignMay not extend above roofline at wall/parapet except: only on single-story building, no more than 2 ft above parapet, max height to top = 16 ft, max projection above parapet = 33.3% of sign height.See formula; max 100 sq ft per face (on >60 ft ROW, 50+ mph); if used with ground sign, area of both is reduced to 1/2 of allowed area (Table 1/Table 4)Not listedNot listedOne per right-of-way frontage; if ≥250 ft frontage, two projecting signs permittedOver public right-of-way or over private property; only installed on own frontage; minimum 8 ft clearance over grade; must be at least 10 ft from another projecting sign.Not listedUnlock74-311-74-322; Table 4; Table 5
Portable Sign (Electric/Non-Electric)Top of sign may not exceed 7 ft above groundNot listed8 ft maxAt least 2 ft inside private property lineNot listedMust be located at least 2 ft inside private property line; not on sidewalk, street, or public thoroughfare.Not listedUnlock74-371-74-374
Directional Sign (Secondary Sign)8 ft max12 sq ft per signNot listedNot listedOne near each drivewayNear each drivewayNot listedUnlock74-343
Temporary Construction Site Sign16 ft160 sq ftNot listedNot listedOne per frontage; +1 if frontage >500 ftGround or wall sign; ground sign must be within 35 ft of frontage right-of-way.Not listedUnlock74-461
Temporary Real Estate Sign (Ground or Wall)16 ft (ground); wall sign may not be above parapet or rooflineSee formulaHorizontal dimension may not exceed 2.5 times verticalNot listedNot listedEntirely within property lines of premises; not in ROWNot listedUnlock74-462
Automatic Changing or Changeable Electronic Variable Message Sign (CEVMS)Not listedNot more than 50% of face of sign; only one electronic sign per platted lot; must comply with maximum for primary sign. Not within 150 ft of residential zone or property.Not listed25 ft from any side property lot line.One electronic sign per platted lot25 ft from any side property lot line; not allowed within 150 ft of residential property.Not listedUnlock74-431

IH 35 Overlay District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Commercial Sign (Ground/Freestanding, Wall, or Projecting allowed if permitted in underlying zone)50 ft (commercial ground sign, within 150 ft of IH 35, per Sec. 74-223)200 sq ft per side (gross face area)Not listedMinimum 30 ft setbackNot listedWithin 150 ft on either side of IH 35 (incorporated city limits); must meet base zone requirements except as modified.Not listedUnlock74-221-74-225

Industrial Zone (LI), Commercial Zone (C-1, C-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignSee General RegulationsSee General RegulationsNot listedNot listedNot listedAffixed to building; see General RegulationsNot listedUnlock74-291; 74-61
Freestanding Sign (Ground Sign)See General RegulationsSee General RegulationsNot listedNot listedNot listedSee General RegulationsNot listedUnlock74-271; 74-61
Projecting SignSee General RegulationsSee General RegulationsNot listedNot listedNot listedSee General RegulationsNot listedUnlock74-311-74-322; 74-61

Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in Selma with a free PermitPal account.

Run a free code check

Prohibited Signs in Selma

  • No sign, sign structure, or sign support shall project over any property line or into a public right-of-way unless otherwise noted.
  • No person shall post, erect, or maintain any sign within the city except as allowed by the provisions of this chapter.
  • No owner of real property within the city shall allow posting, erection, or maintenance of any sign on their property that is in violation of the provisions of this chapter.
  • No person shall post, erect, or maintain any sign within the public right-of-way or upon any public property without prior written consent by the governmental agency.
  • Signs shall not contain product advertising except as necessary to identify the occupant or type of business operation or use.
  • Signs shall not be erected or maintained in a manner that obscures or otherwise physically interferes with an official traffic sign, signal or device, or that obstructs the driver's view of traffic.
  • No sign shall be permitted that is not effectively shielded to prevent beams or rays of light from being directed at any portion of traveled ways of a road or highway, or is of such intensity or brilliance that it causes glare or impairs driver vision.
  • No sign shall interfere with the effectiveness of, or obscure, an official traffic sign, signal or device.
  • No person shall attach, place, paint, write, stamp or paste any sign, advertisement or other matter upon any public property, including lamp posts, poles, hydrants, sidewalks, buildings, etc., except for public purposes.
  • No person shall attach, place, paint, write, stamp or post any sign on private premises without written permission of the owner and compliance with this chapter.
  • The following signs are prohibited in all districts: signs and supports on the public right-of-way without permit; signs with flashing, blinking, or traveling lights (except as specifically permitted); banners, pennants, searchlights, twirling signs, sandwich/A frame signs, sidewalk or curb signs, balloons or gas-filled objects (except by special permit); display of merchandise or work as a sign in residential districts; signs resembling official traffic signs or signals; signs that may be confused with or construed as traffic control signs or signals; signs emitting sound, odor, or visible matter as a distraction to the public right-of-way; billboards or signs advertising products or services not available on the site; roof signs.
  • No sign shall be placed to obstruct or interfere with a window, doorway, or other means of egress, nor be supported on fire escapes, nor attached to door or window casing.
  • No swinging signs shall be erected over a street, alley, or public place (except as expressly permitted over a sidewalk with setbacks).
  • No sign shall be erected or maintained so as to interfere with a fire hydrant, traffic light, fire alarm box, or streetlight, or where it imperils public safety or interferes with fire department functions.
  • The use of staples, wires, and wood plugs in erecting signs is prohibited.
  • No rotating or moving signs shall be permitted, nor shall electrical or illuminated signs blink or be intermittently lighted, nor shall any sign be constructed of reflective material or bear reflective paint, except barber poles.
  • Three-dimensional, air-filled objects (other than balloons under 1 foot in diameter) are prohibited except as specifically allowed for certain temporary events.
  • No vehicle or trailer shall be parked with a sign for the primary purpose of advertising products or directing people, unless it is standard advertising on a business or commercial vehicle whose primary purpose is transportation.
  • Portable signs may not be placed on sidewalks, streets, public thoroughfares, or public property.
  • No portable sign (electric or non-electric) permitted for more than 60 days in any 12-month period at a premises.
  • No portable sign permit may be issued if the sign exceeds certain size/height, has beacons or certain flashing/blinking lights, or is missing bulbs exposing electric sockets.
  • Automatic changing and changeable electronic variable message signs may not use sound.
  • Banners, pennants, flags, streamers, inflatable displays, and other similar devices are not permitted except as specifically described in section 74-481.
  • Ground signs cannot include off-premises advertising or messages except public interest messages.

Exempt Signs in Selma

  • Professional nameplates not exceeding one square foot in area.
  • Memorial signs or tablets, names of buildings, and date of erection when cut into masonry or constructed of bronze or other incombustible material.
  • Traffic or other municipal signs, legal notices, railroad crossing signs, danger and temporary, emergency or non-advertising signs as approved by the planning commission or city council.
  • Temporary signs of a directional nature.
  • Signs noticing public events which are removed immediately after the event.
  • Official notices posted or issued by a court or governmental body.
  • Signs posted, erected, or maintained by the city or other governmental agencies.
  • A governmental flag, with not more than three different or more than one of the same governmental flag displayed per lot (flagpoles must receive approval).
  • Religious symbols.
  • Display of merchandise within any business premises.
  • Signs placed for display not visible to the general public from the public right-of-way or outdoor public areas (such as signs in interior areas of shopping centers, commercial buildings, etc.).
  • Temporary seasonal decoration not used as a display of advertising.
  • Address numbers up to 12 inches in height and four square feet in size.
  • Other signs required by law to be visible from a public right-of-way, provided they do not exceed minimum dimensions specified by law.

Sign Plan & Submission Notes for Selma

  • A comprehensive sign plan may be submitted in lieu of standard sign regulations for planned commercial and industrial developments (including new and existing in any commercial or industrial zone), or planned industrial developments with at least six leaseholds.
  • A comprehensive sign plan must be approved by the planning and zoning commission and must include location, size, height, color, lighting, visual effects, and orientation of all proposed signs.
  • Exceptions to standard sign regulations may be permitted through a comprehensive sign plan if they result in an improved relationship among signs and building facades, and are in conformity with the intent of the chapter.
  • Any permitted variance from sign regulations requires application and recommendation by the planning and zoning commission and approval by the city council after a public hearing.

Source: municode municipal code