Questions? Call us at (262) 218-2915

Sign Regulations in Windcrest, Texas

Windcrest, Texas has specific sign regulations covering 17 sign types across 6 zoning districts. Regulated sign types include Wall Sign, Freestanding Sign (I-35 Corridor), Temporary Sign (Sale or Lease). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 23, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Windcrest, Texas

Sample Sign Requirements in Windcrest

Sign TypeMax HeightMax AreaSetback
Temporary Sign (Sale or Lease)Not listed32 square feetNot listed
Temporary Sign (Construction)Not listed32 square feet per signNot listed
Temporary Sign (New Business)Not listed32 square feet or a mobile sign of similar sizeNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for WindcrestFull Coverage

Sign Types Covered

17

  • Wall Sign
  • Freestanding Sign (I-35 Corridor)
  • Temporary Sign (Sale or Lease)
  • Temporary Sign (Construction)
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Windcrest

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Windcrest, the height limit for Freestanding Sign - Monument (Outside I-35 Corridor) in the B-1, B-2, B-3 zoning districts is 7 feet (Sec. 109-15(d)(1)b.2). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Windcrest require a permit. From the submission notes on this page: A permit application for a sign must include two copies of the plans and specifications; specification data must be certified by a registered Texas engineer for all new pole, multi-tenant, or signs which protrude significantly from buildings (Sec. 109-8(b)(1)). Run a code check for an exact address to see the permit requirements for that zone.

Windcrest's sign code covers 17 sign types, including Wall Sign, Freestanding Sign (I-35 Corridor), Temporary Sign (Sale or Lease), and Temporary Sign (Construction). Most commercial signs need a permit. The ordinance lists 6 exemptions. One of them: Homeowner signs or political signs on private property generally do not require a permit (Sec. 109-8(a)). The full list is on this page.

This page doesn't list a single setback distance for signs in Windcrest. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.

Rules in Windcrest's sign ordinance that cover digital, changing, or flashing signs: The use of changeable electronic variable message signs and digital billboards is prohibited in the city after May 19, 2008, unless expressly permitted (Sec. 109-12(1)). The use of flashing lights, moving lights, animated displays, moving videos or scrolling advertising is prohibited (Sec. 109-12(3)). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Windcrest Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Windcrest, Texas, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Windcrest, Texas Sign Rules at a Glance

Windcrest, Texas regulates 17 sign types across 6 zoning districts. Political Signs in the Residentially Zoned Districts are capped at 8 feet tall and 36 square feet (Sec. 109-19(b)). Most commercial signs in Windcrest require a permit.

Detailed Sign Ordinance Requirements for Windcrest, Texas

Sign Rules by Zoning District in Windcrest (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
B-1, B-2, B-31135 feet70 square feetNot listed
O-12Not listed16 square feet per signNot listed
R-21Not listed16 square feetNot listed
Residentially Zoned Districts28 feet36 square feetNot listed
I-35 Corridor1No restriction, but must be commensurate with need and compatible with surrounding area.Not listedNot listed
General Regulations For All Zones280 feet from ground to top of sign and structure14 feet high x 48 feet wide (display area surface max)Not listed

Zone-by-Zone Sign Requirements in Windcrest(sample of 3 of 6 zones)

B-1, B-2, B-3

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary Sign (Sale or Lease)Not listed32 square feetNot listedNot listed1On-premises of the property for sale or leaseNot listedUnlockSec. 109-13(1)
Temporary Sign (Construction)Not listed32 square feet per signNot listedNot listed1 per contractor, 1 per architect, 1 per future businessAt construction siteNot listedUnlockSec. 109-13(2)
Temporary Sign (New Business)Not listed32 square feet or a mobile sign of similar sizeNot listedNot listed1At newly established commercial activityNot listedUnlockSec. 109-13(3)
Inflatable Device (Seasonal Sign)30 feet above building to which anchoredNot listedNot listedNot listedNot listedAnchored to buildingNot listedUnlockSec. 109-13(5)
Temporary Sign (General Height Restriction)8 feet from ground to top of sign (except inflatable devices)Not listedNot listedCorner lots: no sign within 25 foot triangular area at intersection.Not listedNot listedNot listedUnlockSec. 109-13(6)
Freestanding Sign (I-35 Corridor)No restriction, but must be commensurate with need and compatible with surrounding areaNot listedNo restriction, but must be commensurate with need and compatible with surrounding areaNot listedNot listedI-35 CorridorNot listedUnlockSec. 109-15(d)(1)a
Freestanding Sign - Pole (Outside I-35 Corridor)35 feetNot listed15 feetNot listedNot listedOutside I-35 CorridorNot listedUnlockSec. 109-15(d)(1)b.1 and (3)
Freestanding Sign - Monument (Outside I-35 Corridor)7 feet70 square feetNot listedNot listed1Outside I-35 CorridorNot listedUnlockSec. 109-15(d)(1)b.2

Residentially Zoned Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Residential Advertising SignNot listed4 square feetNot listedNot listed1 per residence (or 2 if on a corner lot); for 'pet' signs up to 6 per permit.On private property or public right-of-way between the front yard and the adjoining street.Not listedUnlockSec. 109-18
Political Sign8 feet36 square feetNot listedNot listedNot listedOn private real property with owner consentNot listedUnlockSec. 109-19(b)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Changeable Electronic Variable Message Sign (CEVMS)Not listed5 feet x 8 feet (face size)Not listedNot listed1 per propertyOn-premises, non-residential (see additional requirements)Not listedUnlockSec. 109-12(2)(c)
City Gateway Sign80 feet from ground to top of sign and structure14 feet high x 48 feet wide (display area surface max)48 feet (display area width)Not listedNot listedAny zoning district on property owned or controlled by city within I-35 CorridorNot listedUnlockSec. 109-14

PermitPal covers all 6 zoning districts in Windcrest. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Windcrest

  • No sign may be placed or installed over public easements or on public property of the city, except as specifically allowed (Sec. 109-9).
  • No permanent or temporary sign shall be placed or installed over public easements or on public property, with certain enumerated exceptions (Sec. 109-9).
  • The use of changeable electronic variable message signs and digital billboards is prohibited in the city after May 19, 2008, unless expressly permitted (Sec. 109-12(1)).
  • The use of flashing lights, moving lights, animated displays, moving videos or scrolling advertising is prohibited (Sec. 109-12(3)).
  • Signs shall not be placed in areas that obstruct the view of motorists (general safety restriction, e.g., Sec. 109-13(6), Sec. 109-18(a)).
  • Signs shall not be placed on rights-of-way (except specific temporary sign exceptions provided; e.g., Sec. 109-13(6)).
  • Signs must be located on the premises of the business advertised (Sec. 109-3).
  • Residential advertising signs must not obstruct the view of motorists and cannot exceed four square feet in area (Sec. 109-18(a)).
  • Unauthorized residential advertising signs may be summarily removed by city employees, and violators may be fined (Sec. 109-18(d)).

Exempt Signs in Windcrest

  • Traffic or other governmental signs necessary for the public health and safety are exempt from prohibition on signs over public property or easements (Sec. 109-9(a)).
  • Temporary signs may be placed on specific medians and city property as described in subsections of Sec. 109-9 (b)-(e).
  • Temporary signs may be placed on public right-of-way extensions with express consent of the adjacent private property owner (Sec. 109-9(f)).
  • Homeowner signs or political signs on private property generally do not require a permit (Sec. 109-8(a)).
  • "For sale," "for rent," "no trespassing" or "safety" residential advertising signs do not require a city permit (Sec. 109-18(b)).
  • Political signs under 36 square feet, under 8 feet in height, and with no moving elements or illumination may be located on private real property with property owner consent, without a permit or fee (Sec. 109-19(b)).

Sign Plan & Submission Notes for Windcrest

  • A permit application for a sign must include two copies of the plans and specifications; specification data must be certified by a registered Texas engineer for all new pole, multi-tenant, or signs which protrude significantly from buildings (Sec. 109-8(b)(1)).
  • Landscaping and irrigation shall be included in all freestanding sign plans (Sec. 109-8(b)(1)).
  • Applications for building permits for freestanding signs must be prepared with two copies of applicable plans and specifications (Sec. 109-15(d)).
  • Upon request by the city inspector, plans and specifications for freestanding signs shall be submitted by a state registered engineer, attesting to compliance with engineering standards and codes (Sec. 109-15(d)).
  • Within ten days after installation of a freestanding sign, the applicant must submit a letter from an engineer/architect certifying the sign was installed according to approved plans (Sec. 109-15(e)).
  • A schematic rendering or illustration must be submitted with the building permit application for a freestanding sign (Sec. 109-15(f)).
  • For signs requiring a waiver of ordinance requirements, the request is forwarded to city council for review and action (Sec. 109-5 and Sec. 109-8(c)(2)).
  • Multi-tenant (group of business establishments) sign plans must be submitted in accordance with established diagrams on file at city hall (Sec. 109-15(g)).

Source: municode municipal code