Questions? Call us at (262) 218-2915

Sign Regulations in Logan, Utah

Logan, Utah has specific sign regulations covering 33 sign types across 14 zoning districts. Regulated sign types include Monument Sign (Freestanding), Perpendicular Sign not within Right-of-Way, Permanent Window Signs. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: October 30, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Logan, Utah

Sample Sign Requirements in Logan

Sign TypeMax HeightMax AreaSetback
Temporary Signs (Noncommercial Message)4 ft4 sq ft per facingOutside sight distance triangle; not in public right-of-way
Multi-Family Complex - Building SignNot listed36 sq ftN/A
Multi-Family Complex - Monument Sign6 ft36 sq ft18 inches from sidewalk; not in 40' street or 30' driveway sight distance triangle

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for LoganFull Coverage

Sign Types Covered

33

  • Monument Sign (Freestanding)
  • Perpendicular Sign not within Right-of-Way
  • Permanent Window Signs
  • Menu Board (Freestanding)
  • +2 more types

Zoning Districts

14

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Logan

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Logan, the height limit for Pole Sign (Freestanding) in the Commercial (COM) zoning district is 14 ft (with minimum 8.5 ft clearance to bottom of sign). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Logan require a permit. From the submission notes on this page: New projects with multiple tenants must have signage areas and locations designated and approved as part of the Design Review Permit; individual tenants may then apply for specific sign permits (§17.33.030.A.3; §17.33.030.B.4). Run a code check for an exact address to see the permit requirements for that zone.

Logan's sign code covers 33 sign types, including Monument Sign (Freestanding), Perpendicular Sign not within Right-of-Way, Permanent Window Signs, and Menu Board (Freestanding). Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Merchandise displays within display windows in commercial buildings (§17.33.020.D). The full list is on this page.

In Logan, Monument Sign (Freestanding) in the Town Center I (TC-1), Town Center II (TC-2) zoning districts must be set back 18 inches from adjoining sidewalk. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Logan's sign ordinance that cover digital, changing, or flashing signs: Monument EMD signs require materials and landscaping review as part of the Sign Permit process (§17.33.160.D.2.c). All Electronic Message Display (EMD) signs require a sign permit and manufacturer certification on illumination and photocell dimming (§17.33.160.A.1; §17.33.160.C.6.b). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Logan Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Logan, Utah, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Logan, Utah Sign Rules at a Glance

Logan, Utah regulates 33 sign types across 14 zoning districts. Menu Boards (Freestanding) in the Commercial (COM) zoning district are capped at 8 ft tall and 72 sq ft, with a 20 ft setback. Most commercial signs in Logan require a permit.

Detailed Sign Ordinance Requirements for Logan, Utah

Sign Rules by Zoning District in Logan (14 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones14 ft4 sq ft per facingNot listed
Low Density Neighborhood Residential (NR - 2), Suburban Neighborhood Residential (NR - 4), Traditional Neighborhood Residential (NR - 6), Mobile Home (MH), Mixed Residential Transitional (MR - 9), Mixed Residential Low (MR - 12), Mixed Residential Medium (MR - 20), Mixed Residential High (MR - 30), Neighborhood Center (NC), Campus Residential (CR), Resource Conservation (RC)106 ft36 sq ftNot listed
Town Center I (TC-1), Town Center II (TC-2)1725 ft (minimum clearance 17 ft)72 sq ftNot listed
Commercial (COM)1925 ft (17 ft min clearance)72 sq ftNot listed
Community Commercial (CC)98 ft72 sq ftNot listed
Mixed Use (MU)1025 ft (17 ft min clearance)72 sq ftNot listed
Gateway (GW)98 ft72 sq ftNot listed
Commercial Service (CS)1225 ft (17 ft min clearance)72 sq ftNot listed
Industrial Park (IP)11Mounted ≤15 ft high72 sq ftNot listed
Airport (AP)98 ft72 sq ftNot listed
Public (PUB)10Mounted ≤15 ft high72 sq ftNot listed
Recreation (REC)10Mounted ≤15 ft high72 sq ftNot listed
Logan Center Street Historic District (HD)1Not listedNot listedNot listed
UC18 ft72 sq ftNot listed

Zone-by-Zone Sign Requirements in Logan(sample of 3 of 14 zones)

Town Center I (TC-1), Town Center II (TC-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Electronic Message Display (EMD) - BuildingMounted no higher than 15 ft above grade24 sq ft maxNot listedN/A1 per project (combined with reader board)On building façadeNot listedUnlockTable 17.33.030.B.1 (EMD 24 sf for TC); §17.33.160.A–D; §17.33.160.B.3; §17.33.060.A; §17.33.160.B.2; §17.33.070.A.1–2
Monument Sign (Freestanding)6 ft32 sq ftNot listed18 inches from adjoining sidewalk1 per street frontage plus 1 additional per street per every 450 ft of frontageAlong street frontage(s) on private propertyNot listedUnlockTable 17.33.030.B.2 (Monument - All zones 32 sf/6 ft); §17.33.040.C.2; §17.33.050.C–E
Electronic Message Display (EMD) - Monument/Freestanding6 ft24 sq ft (EMD portion), and ≤66% of total sign areaNot listed18 inches; and monument placement standards1 per projectOn permitted monument signNot listedUnlockTable 17.33.030.B.2 (EMD for PUB, REC, TC = 24 sf/6 ft); §17.33.160.B–D
Menu Board (Freestanding)6 ft (TC zones)72 sq ftNot listed20 ft2 per drive-through laneDrive-through areasNot listedUnlockTable 17.33.030.B.2 (Menu Board)
Directional Sign (Freestanding)4 ft3 sq ftNot listed0 ftOne per vehicular access pointAt vehicular access points/internal circulationNot listedUnlockTable 17.33.030.B.2 (Directional)
Directory Sign (Freestanding)6 ft24 sq ftNot listed18 inches and must be within 15 ft of primary buildingOne per street frontageOne per street frontage and within 15 ft of primary buildingNot listedUnlockTable 17.33.030.B.2 (Directory)
Archway Sign (Project Identification)25 ft (minimum clearance 17 ft)48 sq ftNot listed5 ft1 per street frontage; max 2 per projectAt vehicle or pedestrian entrances to a project; never above or within public ROWNot listedUnlockTable 17.33.030.B.2 (Archway - COM, MU, TC); §17.33.180
Portable Sign (Sandwich Board/A-Frame)3.5 ft2 ft width; 3.5 ft height2 ftNot in ROW; maintain clear path and access1 portable sign per businessOn pedestrian area abutting the business and within 20 ft of main entrance; entirely outside roadways/drive aisles/landscape/parking; not in public ROWNot listedUnlock§17.33.130 (Portable Signs)

Commercial (COM)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Electronic Message Display (EMD) - BuildingMounted no higher than 15 ft above gradeUp to 32 sq ft (and within 10% façade limit)Not listedN/A1 per project (combined with reader board)On building façadeNot listedUnlockTable 17.33.030.B.1 (EMD COM/IP/CS 10% with 32 sf max); §17.33.160.A–D; §17.33.060.A; §17.33.160.B.3
Pole Sign (Freestanding)14 ft (with minimum 8.5 ft clearance to bottom of sign)48 sq ftNot listed10 ft from ROW/property line1 per project (no monument signs allowed)On private propertyNot listedUnlockTable 17.33.030.B.2 (Pole - COM only); §17.33.050.B; §17.33.040.C.1; §17.33.070.A.6
Monument Sign (Freestanding)8 ft72 sq ftNot listed18 inches from sidewalk1 per street frontage + 1 per street per every 450 ftAlong street frontage(s)Not listedUnlockTable 17.33.030.B.2 (Monument - 72 sf/8 ft for COM, UC, MU, IP & CS); §17.33.040.C.2; §17.33.050.E
Electronic Message Display (EMD) - Monument/Freestanding8 ft32 sq ft EMD portion and ≤66% of total sign areaNot listed18 inches; monument placement standards apply1 per projectOn permitted monument signNot listedUnlockTable 17.33.030.B.2 (EMD COM/IP/CS); §17.33.160.D.2
Menu Board (Freestanding)8 ft72 sq ftNot listed20 ft2 per drive-through laneDrive-through areasNot listedUnlockTable 17.33.030.B.2 (Menu Board)
Directional Sign (Freestanding)4 ft3 sq ftNot listed0 ftOne per vehicular access pointAt vehicular access points/internal circulationNot listedUnlockTable 17.33.030.B.2 (Directional)
Directory Sign (Freestanding)6 ft24 sq ftNot listed18 inches and within 15 ft of buildingOne per street frontageOne per street frontage and within 15 ft of primary buildingNot listedUnlockTable 17.33.030.B.2 (Directory)
Portable Sign (Sandwich Board/A-Frame)3.5 ft2 ft width; 3.5 ft height2 ftNot in ROW; maintain clear access1 per businessOn pedestrian area abutting business within 20 ft of entrance; not in ROW/landscape/parking/drive aislesNot listedUnlock§17.33.130

Commercial Service (CS)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Building Sign Types (Individual Letters, Sign Board, Painted Copy, Cabinet, Awning, Reader Board)Not listed10% of first-story façade areaNot listedN/APer façade area limitOn building façadeNot listedUnlockTable 17.33.030.B.1 (Cabinet allowed; EMD building allowed in CS)
Electronic Message Display (EMD) - BuildingMounted ≤15 ft highUp to 32 sq ft (and within 10% façade limit)Not listedN/A1 per project (combined with reader board)On building façadeNot listedUnlockTable 17.33.030.B.1 (EMD COM, IP, CS); §17.33.160.A–D; §17.33.160.B.3
Monument Sign (Freestanding)8 ft72 sq ftNot listed18 inchesAs statedAlong street frontage(s)Not listedUnlockTable 17.33.030.B.2 (Monument - 72/8 for COM, UC, MU, IP & CS)
Electronic Message Display (EMD) - Monument/Freestanding8 ft32 sq ft EMD portion and ≤66% of total sign area (<450 ft frontage); 47 sq ft and ≤66% (>450 ft frontage)Not listed18 inches1 per projectOn permitted monument signNot listedUnlockTable 17.33.030.B.2 (EMD - COM, IP, CS); §17.33.160.D.2
Menu Board (Freestanding)8 ft72 sq ftNot listed20 ft2 per drive-through laneDrive-through areasNot listedUnlockTable 17.33.030.B.2
Directional Sign (Freestanding)4 ft3 sq ftNot listed0 ftOne per vehicular access pointAccess points/internal circulationNot listedUnlockTable 17.33.030.B.2 (Directional)
Directory Sign (Freestanding)6 ft24 sq ftNot listed18 inches and within 15 ft of buildingOne per street frontageOne per street frontage and within 15 ft of buildingNot listedUnlockTable 17.33.030.B.2 (Directory)
Archway Sign (Project Identification)25 ft (17 ft min clearance)48 sq ftNot listed5 ftAs statedAt project entrances; never above/within ROWNot listedUnlockTable 17.33.030.B.2 (Archway - COM, MU, TC); §17.33.180

PermitPal covers all 14 zoning districts in Logan. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Logan

  • Signs that do not comply with the sign code or sign types not specified are prohibited, except legally existing nonconforming signs (§17.33.140.A)
  • Off-premise signs are prohibited except where specifically allowed by the chapter (§17.33.140.B)
  • Signs above or within the public right-of-way are prohibited except as specifically allowed (§17.33.140.C; §17.33.150.A)
  • Permanent signs on lots without a principal use are prohibited (§17.33.140.D)
  • Building signs may not extend above the parapet or roof; roof-mounted signs are prohibited (§17.33.140.E–F)
  • Portable reader boards and other portable signs not attached to a building or the ground are prohibited except as otherwise defined (§17.33.140.G)
  • Signs that rotate, flash, move, or give the appearance of motion are prohibited (barber poles excepted) (§17.33.140.H)
  • Signs attached to or towed behind a vehicle are prohibited except permanent business identification or magnetic signs; using vehicles or trailers as signs in the manner described is prohibited (§17.33.140.I, §17.33.140.P)
  • Signs that emit sound, odor, smoke, or vapor are prohibited (§17.33.140.J)
  • Signs painted on or attached to utility poles, trees, or natural features are prohibited (except permitted engraved boulders per a sign permit) (§17.33.140.K)
  • Abandoned or dilapidated signs and signs advertising businesses no longer licensed or located on-site are prohibited (§17.33.140.L)
  • Sign structures, poles, pylons, and supports not maintained in good aesthetic and physical condition are prohibited (§17.33.140.M)
  • Signs with visible frames are prohibited unless part of the approved sign design (§17.33.140.N)
  • Obscene signs are prohibited (§17.33.140.O)
  • Signage with a visible or direct light source is prohibited unless neon or other lighting approved as part of the sign design; light sources used to illuminate signs shall not be visible from adjacent rights-of-way or properties (§17.33.140.Q; §17.33.060.D)
  • Signs that would cause a violation of the building code are prohibited (§17.33.140.R)
  • Attention-getting devices, inflatable objects (except balloons), and inflatable signs are prohibited (§17.33.140.S)
  • Signs placed, held, or worn in the public right-of-way or off-premise for commercial advertisement directed to vehicle or pedestrian traffic are prohibited (§17.33.140.T)
  • All signs and sign structures must be located entirely within the boundaries of the lot of the principal building or use (except where expressly allowed) (§17.33.050.A)

Exempt Signs in Logan

  • Official public notice, traffic control, warning, or safety signs as required by law (§17.33.020.A)
  • Appropriately displayed official flags of any country, federal agency, State, County, or City government (§17.33.020.B)
  • Any sign located within a building and not visible from a public street (§17.33.020.C)
  • Merchandise displays within display windows in commercial buildings (§17.33.020.D)
  • Identification sign(s) or logo(s) applied to the outside surface of a vehicle, provided the vehicle or trailer is not used as a sign as defined in Prohibited Signs (§17.33.020.E; §17.33.140)
  • Murals or wall art that do not contain any commercial messaging or commercial copy; murals/wall art with commercial messaging are regulated as signs (§17.33.020.F)
  • Public or private memorials or displays of remembrance of persons or events (§17.33.020.G)
  • Window displays and signs located within a store and not attached to a window are not regulated by the City (§17.33.080.B)

Sign Plan & Submission Notes for Logan

  • New projects with multiple tenants must have signage areas and locations designated and approved as part of the Design Review Permit; individual tenants may then apply for specific sign permits (§17.33.030.A.3; §17.33.030.B.4)
  • Freestanding and perpendicular signs require plans stamped by a Utah-licensed professional engineer per the International Building Code (§17.33.070.A.6)
  • Certain signs may require additional approval from the Planning Commission or Historic Preservation Committee (e.g., signs in the Logan Center Street Historic District) depending on sign type and/or location (§17.33.070.A.8)
  • Special event temporary signs require a signage and marketing plan submitted and approved as part of a Special Event License before placing signs (§17.33.110.E.11)
  • Temporary event banners in the Town Center zone require a sign permit prior to installation for each temporary event (§17.33.120.D.6)
  • Archway signs require track two design review approval (§17.33.180)
  • Community or public events may place signs in the public right-of-way only with approval from the Department of Community Development and the City Administration Department (§17.33.150.A.3)
  • Monument EMD signs require materials and landscaping review as part of the Sign Permit process (§17.33.160.D.2.c)
  • All Electronic Message Display (EMD) signs require a sign permit and manufacturer certification on illumination and photocell dimming (§17.33.160.A.1; §17.33.160.C.6.b)

Source: other municipal code