Sign Regulations in Port Angeles, Washington

Port Angeles, Washington has specific sign regulations covering 28 sign types across 9 zoning districts. Regulated sign types include Freestanding Sign, Shopping Mall Sign (Wall), Shopping Mall Sign (Freestanding). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 5, 2025

Sign Regulation Overview for Port Angeles, Washington

Sample Sign Requirements in Port Angeles

Sign TypeMax HeightMax AreaSetback
Wall Sign200 square feet per business façade (or 20% of façade, whichever is less)
Marquee or Awning SignNot to exceed 2 feet above front outer top edge of the marquee/awning
Pedestrian Sign6 square feet per side

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Port AngelesFull Coverage

Sign Types Covered

28

  • Freestanding Sign
  • Shopping Mall Sign (Wall)
  • Shopping Mall Sign (Freestanding)
  • Building-mounted Sign
  • +2 more types

Zoning Districts

9

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Port Angeles

City WebsiteMunicipal Code5 permit application links available

Frequently Asked Questions

Sign height limits in Port Angeles vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Port Angeles, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Port Angeles, regulated sign types include Freestanding Sign, Shopping Mall Sign (Wall), Shopping Mall Sign (Freestanding), Building-mounted Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Port Angeles vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Port Angeles are regulated with specific requirements for brightness, animation, and message duration. Port Angeles has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Port Angeles Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Port Angeles, Washington sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Port Angeles, Washington Sign Rules at a Glance

Port Angeles, Washington regulates 28 sign types across 9 zoning districts. Freestanding Sign (15+ ft setback, single street)s in the Central Business District (CBD) Zone zoning district are capped at 20 feet tall and 25 square feet per side, with a More than 15 ft from ROW setback (Sec. 14.36.070(A)(4)). Most commercial signs in Port Angeles require a permit.

Detailed Sign Ordinance Requirements for Port Angeles, Washington

Sign Rules by Zoning District in Port Angeles (9 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Central Business District (CBD) Zone1330 feet300 square feet per façade
Commercial Arterial (CA) Zone735 feet300 square feet total sign area
Community Shopping District (CSD) Zone730 feet300 square feet per façade
Commercial Neighborhood (CN) Zone120 feet100 square feet total sign area per site
Commercial Office (CO) Zone1Freestanding signs: 5 feet; Building-mounted signs: 20 feet50 square feet total sign area per site; if site area is 14,000 sq ft or more, max 100 sq ft
Industrial Park (IP) Zone, Industrial Light (IL) Zone435 feet300 square feet per elevation facing street
Industrial Heavy (IH) Zone335 feet400 square feet per elevation facing street
Public Buildings and Parks (PBP) Zone220 feet100 square feet per building
General Regulations For All Zones344 inches100 square feet per business

Zone-by-Zone Sign Requirements in Port Angeles(sample of 3 of 9 zones)

Central Business District (CBD) Zone

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign200 square feet per business façade (or 20% of façade, whichever is less)Parallel to building façade. On main street, alley, or side walls as applicable.Unlock14.36.070(A), (A)(1), (A)(8), (A)(9)
Marquee or Awning SignNot to exceed 2 feet above front outer top edge of the marquee/awningMay be mounted on front, side, or top of marquee/awning. If projecting below marquee/awning, must meet pedestrian sign requirements.Unlock14.36.070(A)(2)
Pedestrian Sign6 square feet per sideAttached to underside of marquee or awning, at right angle to façade; does not extend beyond outer edgeUnlock14.36.070(A)(3)
Freestanding Sign (15+ ft setback, single street)20 feet25 square feet per sideMore than 15 ft from ROW1 per qualifying buildingWhere all portions of the building are more than 15 ft from right-of-way.Unlock14.36.070(A)(4)
Freestanding Sign (40+ ft setback, multiple streets)30 feet100 square feet per side or 200 sq ft total (whichever is less)More than 40 ft1 per qualifying buildingWhere building has frontage on 2 or more streets and is more than 40 ft from those streets.Unlock14.36.070(A)(4)
Wall Sign (Upper floor business)200 square feet1 ground-level sign for upstairs business (max 6 sq ft)On building façade with street frontageUnlock14.36.070(A)(6)
Shopping Mall Sign (Freestanding)20 feet100 square feet per side (200 sq ft total), max 2 per siteMore than 15 ft1 per street frontage, max 2 per mall siteWhere all portions of shopping mall >15 ft from right-of-way; one per street frontageUnlock14.36.070(A)(10)
Freestanding Sign (Non-building business)20 feet32 square feet per side1 per street frontageOn non-building business property, 1 per street frontageUnlock14.36.070(A)(11)

Commercial Arterial (CA) Zone

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Building-mounted Sign (Single Business)250 square feet per elevation facing public streetNo closer than 100 ft to residential zone if sign is over 10 sq ftPlaced on any wall not facing an adjacent residential zone; not above eaves/parapet, not on roof.Unlock14.36.070(B)(1)
Building-mounted Sign (Multiple Businesses)250 square feet per elevation for each businessNo closer than 100 ft to residential zone if sign is over 10 sq ftSame as aboveUnlock14.36.070(B)(1)
Freestanding Sign35 feetVaries by site size (see sign size restrictions). Max overall visible sign area: <0.5 acre = 100 sq ft; 0.5-0.99 acre = 200 sq ft; 1-1.99 acres = 300 sq ft; 2-2.99 acres = 400 sq ft; 3+ acres = 500 sq ft.No closer than 100 ft to residential zone if over 10 sq ftUnlock14.36.070(B)(2)
Off-premise Sign (Billboard or Outdoor Advertising)35 feet300 square feet total sign area1 per qualifying siteOn sites with no onsite business signageUnlock14.36.070(B)(3)
Shopping Mall Sign (Wall)300 square feet per façadeAny façade; must be part of master sign permitUnlock14.36.070(B)(4)
Shopping Mall Sign (Freestanding)20 feet100 square feet per side (200 sq ft max); max 2 per siteMore than 15 ft from ROW1 per street frontage, max 2/siteAll portions of mall >15 ft from ROW; 1 per street frontageUnlock14.36.070(B)(4)
Fluttering Devices (Auto Dealerships/RV/Boat/etc)Outdoor sales lots of new and used auto, truck, trailer, motorcycle, RV, tractor, and boat dealershipsUnlock14.36.070(B)(5)

Community Shopping District (CSD) Zone

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Building-mounted Sign (Single Business)175 square feet per elevation facing public streetNo sign over 10 sq ft within 100 ft of a residential zoneOn any wall not facing adjacent residential zoneUnlock14.36.070(C)(1)(a)
Building-mounted Sign (Multiple Businesses)175 square feet per elevation per businessNo sign over 10 sq ft within 100 ft of residential zoneOn any wall not facing adjacent residential zone.Unlock14.36.070(C)(1)(b)
Alley Sign175 square feetOn alley-facing building wallUnlock14.36.070(C)(1)(c)
Side Wall Sign (No Street Frontage)175 square feetExposed side walls visible from public street (not street frontage walls)Unlock14.36.070(C)(1)(d)
Freestanding Sign30 feet≤0.5ac: 50 sq ft; 0.5–0.99ac: 75 sq ft; 1–1.99ac: 100 sq ft; 2–2.99ac: 125 sq ft; ≥3ac: 150 sq ft.No sign over 10 sq ft within 100 ft of residential zoneUnlock14.36.070(C)(2)
Shopping Mall Sign (Wall)300 square feet per façadeAny façade, part of master sign permitUnlock14.36.070(B)(4)/C
Shopping Mall Sign (Freestanding)20 feet100 sq ft per side (200 sq ft max), max two signs per siteMore than 15 ft1 per street frontage, max 2 per siteAll portions of mall greater than 15 ft from street right-of-way; one per street frontageUnlock14.36.070(B)(4)/C

PermitPal covers all 9 zoning districts in Port Angeles — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 9 zones for Port Angeles — start free

Prohibited Signs in Port Angeles

  • No person shall erect, relocate, or otherwise construct or alter any sign in the City without complying with this chapter and, when required, obtaining a sign permit from the Building Division of the City of Port Angeles.
  • All signs illuminated by, or containing, blinking, flashing, intermittent, or moving lights and all flashing, rotating, or intermediate lights in, on, or around windows, rooflines, or building exteriors are prohibited, except electronically changing message/digital time/temperature signs which do not change the message more than once per 30 seconds, and the moving hands of a clock.
  • All roof-mounted signs, including any signs painted directly on the roof surface, are prohibited.
  • Fluttering devices are prohibited, except for specific exceptions noted for certain zones and openings of new businesses.
  • Billboards and other off-premise outdoor advertising signs are prohibited except as specifically permitted in certain zones (with conditional use permits and spacing requirements).
  • Temporary signs located on or resting against a motor vehicle, trailer, bicycle, planter, or decorator card for the purpose of advertisement or directing people to a business are prohibited.
  • All signs which purport to call attention to a business or building with words such as 'look', 'stop', 'slow down', or other words similar to traffic signals or signs are prohibited.
  • All moving, rotating, or animated signs are prohibited, except barber poles.
  • All signs which no longer serve an ongoing business are prohibited and must be removed upon closure of the business or cessation of product sale.
  • All signs which have no permanent attachment to a building or the ground are prohibited, except A-frame signs and sandwich boards exempted or specifically permitted.
  • Projecting signs that project further than four and one-half feet from the building façade are prohibited.
  • Banner signs are prohibited in the Central Business District (CBD) Zone.
  • All signs not specifically addressed and contrary to the provisions of this chapter are prohibited.
  • Illumination from or upon any sign shall be shaded, shielded, directed, or reduced to avoid undue brightness, glare, or reflection of light on property in the surrounding area and unreasonably distracting pedestrians and motorists.
  • Signs must comply with all other ordinances of the City; non-commercial sign content shall not be regulated.
  • Signs shall be maintained to protect public safety, present a well kept appearance, and prevent deterioration.
  • Failure to remove signs that are prohibited or not properly maintained is a violation subject to abatement and penalties.
  • Any sign erected, constructed, moved, or altered in violation of this chapter is declared a public nuisance, subject to enforcement and injunction.

Exempt Signs in Port Angeles

  • Official traffic signs, directional signs, banners, signals, business directory maps, kiosks, and public notices erected by public authorities are exempt from sign permit requirements.
  • Informational service signs such as 'customer parking', 'driveway entrance', and 'exit', not exceeding six square feet, are exempt from sign permit requirements, though an electrical permit may be required.
  • Signs identifying public conveniences (restrooms, telephones, bus stops, taxicab stands), not exceeding three square feet, are exempt.
  • Informational warning signs such as 'no trespassing', 'no dumping', 'no parking', not exceeding eight square feet, are exempt.
  • Building address identification numbers of specified size are exempt.
  • Permanent building identification (plaques, cornerstones, name plates) is exempt.
  • Temporary political signs, provided such signs are not located in public rights-of-way and are removed within 14 days after the election, are exempt.
  • Temporary decorations customarily displayed at special holidays, provided removal occurs within 14 days, are exempt.
  • Seasonal decorations, festive banners, and other noncommercial displays affixed to poles or standards by the City or nonprofits are exempt.
  • One temporary real estate sign per street frontage not exceeding eight square feet, and two A-frame open house signs not exceeding eight square feet each, if properly located and timely removed, are exempt.
  • One temporary sign denoting architect, engineer, or contractor for work under construction, not exceeding eight square feet and timely removed, is exempt.
  • Any sign within a building not visible from the street or sidewalk is exempt, though an electrical permit may be required.
  • Sculptures, fountains, mosaics, murals not incorporating advertising or business identification are exempt.
  • Sandwich board signs worn by a person walking the public ways are exempt.
  • Signs painted directly on windows, and inside window signs, except as may be specifically prohibited elsewhere (e.g., by PAMC 14.36.080), are exempt.
  • Traditional theater marquees not exceeding 260 square feet are exempt, though a building and electrical permit may be required.
  • Barber poles are exempt, though an electrical permit is required for installation.
  • Temporary community service signs erected by community organizations to announce events or record community goals, under certain size, permit, and time restrictions, are exempt (but not signs otherwise specifically prohibited).
  • Signs mounted on public transit vehicles and facilities are exempt.
  • The changing of advertising copy or message on a lawfully erected painted or printed sign, marquee, or similar sign designed for changeable copy is exempt from sign permit requirements.
  • Maintenance or cleaning of a sign, and repainting existing copy of a permitted or legal nonconforming sign (within allowable period), are exempt from permit requirements.

Sign Plan & Submission Notes for Port Angeles

  • A master sign permit is required for shopping mall façades in the Central Business District (CBD) and Commercial Arterial (CA) Zones, identifying all signs for the shopping mall and issued in the name of the mall manager.
  • Variance applications may be requested when strict enforcement imposes hardship; requires a formal application and a public hearing before the Board of Adjustment.
  • A sign permit from the Building Division is required for the erection, relocation, construction, or alteration of most signs, unless specifically exempt.
  • Temporary community service signs require installation pursuant to a building permit to be exempt.
  • A right-of-way use permit and specific mention in the sign owner’s insurance policy are required for A-frame signs located within public rights-of-way.

Source: municode municipal code