Questions? Call us at (262) 218-2915

Sign Regulations in Westover, West Virginia

Westover, West Virginia has specific sign regulations covering 11 sign types across 2 zoning districts. Regulated sign types include Ground Sign, Wall Sign, Projecting Sign - Horizontal. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 20, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Westover, West Virginia

Sample Sign Requirements in Westover

Sign TypeMax HeightMax AreaSetback
Ground Sign100 feetNot listedNo nearer the street than the established building line
Wall SignNot listed700 square feet per sign; No more than 1,000 square feet of wall signs per one building sideCannot extend more than 24 inches beyond the building line; not less than 10 feet high
Projecting Sign - HorizontalNot listed200 square feet per sideNot more than 2 feet from wall to sign, minimum 10 feet above sidewalk, no part closer than 1 foot to curb, 15 feet above alleys/driveways

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for WestoverFull Coverage

Sign Types Covered

11

  • Ground Sign
  • Wall Sign
  • Projecting Sign - Horizontal
  • Projecting Sign - Vertical
  • +2 more types

Zoning Districts

2

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

In Westover, the height limit for Ground Sign in the Commercial District Two (C-2) is 100 feet. The height limit for Signs Attached to Marquee is 5 feet max (exclusive of name) (Sec. 1741.19(e)-(f)). Maximum sign heights range from 30 feet to 100 feet across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Westover require a permit. From the submission notes on this page: Every person desiring to erect, repair, alter, relocate or maintain any sign or outdoor display sign must file an application for an erection permit, which must include a copy of the plan and structural drawings of such sign or structure. Run a code check for an exact address to see the permit requirements for that zone.

Westover's sign code covers 11 sign types, including Ground Sign, Wall Sign, Projecting Sign - Horizontal, and Projecting Sign - Vertical. Most commercial signs need a permit. The ordinance lists 10 exemptions. One of them: Election signs. The full list is on this page.

In Westover, Temporary Sign in the Commercial District Two (C-2) must be set back at least 2 feet from property line (Sec. 1741.18). The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Westover's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.

AI-Powered Research

Ready to Research Westover Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Westover, West Virginia, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Westover, West Virginia Sign Rules at a Glance

Westover, West Virginia regulates 11 sign types across 2 zoning districts. Roof Signs are capped at 20 feet above roof level and 300 square feet per sign. Most commercial signs in Westover require a permit.

Detailed Sign Ordinance Requirements for Westover, West Virginia

Sign Rules by Zoning District in Westover (2 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Commercial District Two (C-2)11100 feet700 square feet per sign; No more than 1,000 square feet of wall signs per one building sideNot listed
General Regulations For All Zones1130 feet500 square feet per signNot listed

Zone-by-Zone Sign Requirements in Westover

Commercial District Two (C-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground Sign100 feetNot listedNot listedNo nearer the street than the established building lineNot listedNo nearer the street than the established building line; at least 2 feet from any other sign, building, or structure; minimum 2 feet open space between sign base and ground (can be partially filled as described)Not listedUnlock1741.14(c)(1); 1741.02 (fees); 1741.12(b); 1741.08; 1741.14
Wall SignNot listed700 square feet per sign; No more than 1,000 square feet of wall signs per one building sideNot listedCannot extend more than 24 inches beyond the building line; not less than 10 feet highMax 1,000 sq ft of wall signs per side of buildingAgainst building’s exterior wall, not above wall top or beyond ends. Cannot cover or block any wall opening. Cannot extend more than 24 inches beyond the building line. Not less than 10 feet above sidewalk or ground.Not listedUnlock1741.15(b)-(c); 1741.02 (fees); 1741.08; 1741.12(b)
Projecting Sign - HorizontalNot listed200 square feet per sideNot listedNot more than 2 feet from wall to sign, minimum 10 feet above sidewalk, no part closer than 1 foot to curb, 15 feet above alleys/drivewaysNot listedAttached to building, extends out (not more than 2 feet from wall to nearest part), at least 10 feet above sidewalk, no part closer than 1 foot to curb. Over driveways/alleys, at least 15 feet above.Not listedUnlock1741.17(b)-(f); 1741.02 (fees); 1741.08
Projecting Sign - VerticalNot listed200 square feet per sideNot listedSame as Horizontal Projecting SignNot listedSame as Horizontal Projecting SignNot listedUnlock1741.17(b)-(f); 1741.02 (fees); 1741.08
Roof Sign20 feet above roof level300 square feet per signNot listedSet back at least 5 feet from roof edge it facesNot listedEntirely upon or over roof, main support on roofNot listedUnlock1741.16(b)-(d); 1741.02 (fees); 1741.08; 1741.12(b)
Temporary Sign4 feet (max single dimension)100 square feet (max); If over 60 sq ft: must be rigid frame typeNot listedAt least 2 feet from property line; can only project max 4 in from wall over public propertyNot listedAllowed on private property only; must be set back 2 feet from property line; cannot extend/protrude onto/above public property or openingsNot listedUnlock1741.18
MarqueeNot listedNot listedWidth of entrance(s) plus 5 ft on each side; continuous structure allowed if entrances <20 feet apartAt least 1 ft inside curb lineNot listedProjecting from wall above entrance, over public thoroughfare, at least 1 ft inside curb lineNot listedUnlock1741.19
Signs Attached to MarqueeMax 5 feet in height for advertising material (not including establishment name)Not listedNot listedNo lower than 10 ft above sidewalkNot listedCompletely within outer border of marquee; not less than 10 ft above sidewalk or public thoroughfareNot listedUnlock1741.19(e)-(f)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground Sign30 feetNot listedNot listedNo nearer to street than established building lineNot listedAt least 2 feet from another sign, building, or structure; open space at least 2 ft between baseline and ground; not closer to street than building line; open space can be partly filled as describedNot listedUnlock1741.14(b)-(e); 1741.02(e); 1741.08; 1741.12(b)
Wall SignNot listed500 square feet per signNot listedNo more than 6 inches beyond building line; not less than 10 feet highNot listedAttached to exterior wall, not to extend over ends/top or cover any opening; cannot extend more than 6 inches beyond building line; not less than 10 feet above sidewalk or groundNot listedUnlock1741.15(b)-(c); 1741.02(e); 1741.08; 1741.12(b)
Roof Sign20 feet above roof level300 square feet per signNot listedSetback min 5 ft from roof edge; base at least 5 ft above roofNot listedWholly on or above roof, main support on roofNot listedUnlock1741.16(b)-(d); 1741.02(e); 1741.08; 1741.12(b)
Projecting Sign - HorizontalNot listed50 square feet per sideNot listedMax 2 ft from wall; 10 ft min above sidewalk; 1 ft min from curbNot listedAttached to building, not more than 2 feet out from wall, at least 10 ft above sidewalk, no part closer than 1 ft to curb; 15 ft above driveways/alleysNot listedUnlock1741.17(b)-(f); 1741.02(e); 1741.08
Projecting Sign - VerticalNot listed100 square feet per sideNot listedAs for Projecting Sign - HorizontalNot listedAs for Projecting Sign - HorizontalNot listedUnlock1741.17(b)-(f); 1741.02(e); 1741.08
Temporary Sign4 feet (max single dimension)100 square feet (max); If over 60 sq ft: must be rigid frame typeNot listedMin 2 ft from property line (private property); max 4 in from wall over public spaceNot listedOn private property, min setback 2 ft from property line; cannot extend more than 4 inches over/into public property from wall; cannot project over or block any wall opening; not allowed on public propertyNot listedUnlock1741.18
MarqueeNot listedNot listedEntrance width plus 5 ft per side; continuous if entrances within 20 ftNot more than 1 ft inside curb lineNot listedAbove entrance, may project over public way, not more than 1 ft inside curbNot listedUnlock1741.19
Signs Attached to Marquee5 feet max (exclusive of name)Not listedNot listedMin 10 ft above sidewalkNot listedWithin outer edge of marquee, minimum 10 ft above sidewalk/public wayNot listedUnlock1741.19(e)-(f)

Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in Westover with a free PermitPal account.

Run a free code check

Prohibited Signs in Westover

  • No sign shall be erected, relocated or maintained so as to prevent free ingress to or egress from any door, window or fire escape.
  • No sign of any kind shall be attached to a stand pipe or fire escape.
  • No sign or advertising structure regulated by this article shall be erected at the intersection of any streets in such a manner as to obstruct free and clear vision.
  • No sign shall be erected at any location where, by reason of the position, shape or color, it may interfere with, obstruct the view of or be confused with any authorized traffic sign, signal or device.
  • No sign shall make use of the words 'STOP,' 'LOOK,' 'DRIVE-IN,' 'DANGER,' or any other word, phrase, symbol or character in such manner as to interfere with, mislead or confuse traffic.
  • No person shall display upon any sign or other advertising structure any obscene, indecent or immoral matter.
  • No sign or other advertising structure shall be erected, constructed or maintained in violation of the provisions of this article.
  • It is unlawful to stick, post or attach any advertisement, poster, sign, handbill or placard of any kind or description upon public property (telegraph, telephone, railway, or electric light poles, public buildings, vehicles, voting booths, flagging, curb, tree, lawn, walk, stepstone, sidewalk, or property of the City).
  • No temporary signs of any kind are allowed on public property.
  • No temporary sign shall be erected so as to prevent free ingress to or egress from any door, window or fire escape, nor shall such sign be attached to any standpipe or fire escape.
  • No sign shall hide from view or interfere with the effectiveness of any official traffic control device or any railroad sign or signal.
  • No V-shaped signs, consisting of two single faced signs erected without a roof or ceiling, are permitted.
  • No projecting sign shall be secured with wire, strips of wood or nails, nor shall any projecting sign be hung or secured to any other sign.

Exempt Signs in Westover

  • Real estate signs not exceeding eight square feet in area which advertise the sale, rental or lease of the premises upon which such signs are located only.
  • Professional name plates not exceeding one square foot in area.
  • Signs painted on the exterior surface of a building or structure, provided they have no raised borders, letters, characters, decorations or lighting appliances (otherwise are regulated).
  • Bulletin boards not over eight square feet in area for public, charitable or religious institutions when located on the premises of such institutions.
  • Signs denoting the architect, engineer or contractor, when placed upon work under construction, and not exceeding sixteen square feet in area.
  • Occupational signs denoting only the name and profession of an occupant in a commercial building, public institutional building or dwelling house, and not exceeding two square feet in area.
  • Memorial signs or tablets, names of buildings and date of erection when cut into masonry surface or constructed of bronze or other incombustible materials.
  • Traffic or other municipal signs, legal notices, railroad crossing signs, danger and such temporary, emergency, or nonadvertising signs as may be approved by Council.
  • Election signs.
  • Political signs are exempt from fees but must follow construction and location requirements.

Sign Plan & Submission Notes for Westover

  • Every person desiring to erect, repair, alter, relocate or maintain any sign or outdoor display sign must file an application for an erection permit, which must include a copy of the plan and structural drawings of such sign or structure.
  • The application for a sign permit may require, upon request by the Mayor, stress sheets and calculations required to ascertain whether the sign is designed for dead load and wind pressure as required by the Building Code.
  • There is no explicit mention of a 'master sign plan' or formal 'variance meeting' requirement in the general provisions, but special permit categories (such as ground signs exceeding height limits) must be referred to Council for disposition.