Sign Regulations in Dresser, Wisconsin

Dresser, Wisconsin has specific sign regulations covering 12 sign types across 4 zoning districts. Regulated sign types include Wall Sign, Projecting Sign, Ground Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 28, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Dresser, Wisconsin

Sample Sign Requirements in Dresser

Sign TypeMax HeightMax AreaSetback
Wall Sign20 feet above the mean center line street grade200 square feetNot listed
Projecting Sign20 feet above the mean center line street grade100 square feetShall not be less than 10 feet from all side lot lines
Ground Sign20 feet above the mean center line street grade200 square feet on all sidesNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for DresserFull Coverage

Sign Types Covered

12

  • Wall Sign
  • Projecting Sign
  • Ground Sign
  • Roof Sign
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Dresser

Frequently Asked Questions

In Dresser, the height limit for Ground Sign is 20 feet above the mean center line street grade (Sec. 17.25(6)(c)). The height limit for Wall Sign is 20 feet above the mean center line street grade (Sec. 17.25(6)(a)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Dresser require a permit. From the submission notes on this page: Signs promoting community, service, fraternal or youth organizations that are specifically approved by the Plan Commission are exceptions to the prohibition of signs in the public right-of-way. Run a code check for an exact address to see the permit requirements for that zone.

Dresser's sign code covers 12 sign types, including Wall Sign, Projecting Sign, Ground Sign, and Roof Sign. Most commercial signs need a permit. The ordinance lists 2 exemptions. One of them: National, State or local government flags or the official flag of any institution or business shall not be considered as wind signs. The full list is on this page.

In Dresser, Temporary Real Estate Sign in the Residential Districts must be set back at least 100 feet from any residence (Sec. 17.25(5)(h)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Dresser's sign ordinance that cover digital, changing, or flashing signs: No sign shall be erected that has any flashing, rotating or brilliant intermittent parts or lights or bare reflecting bulbs except those giving public service information. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Dresser Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Dresser, Wisconsin, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Dresser, Wisconsin Sign Rules at a Glance

Dresser, Wisconsin regulates 12 sign types across 4 zoning districts. Roof Signs are capped at 10 feet above the roof and 200 square feet (Sec. 17.25(6)(d)). Most commercial signs in Dresser require a permit.

Detailed Sign Ordinance Requirements for Dresser, Wisconsin

Sign Rules by Zoning District in Dresser (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones420 feet above the mean center line street grade200 square feetNot listed
Residential Districts82 feet100 square feetNot listed
Commercial Districts420 feet above the mean center line street grade200 square feetNot listed
Industrial Districts420 feet above the mean center line street grade200 square feetNot listed

Zone-by-Zone Sign Requirements in Dresser(sample of 3 of 4 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign20 feet above the mean center line street grade200 square feetNot listedNot listedNot listedExterior walls of buildingsNot listedUnlock17.25(6)(a)
Projecting Sign20 feet above the mean center line street grade100 square feetNot listedShall not be less than 10 feet from all side lot linesNot listedFastened to, suspended from or supported by structuresNot listedUnlock17.25(6)(b)
Ground Sign20 feet above the mean center line street grade200 square feet on all sidesNot listedNot listedNot listedOn the ground, meeting all yard requirementsNot listedUnlock17.25(6)(c)
Roof Sign10 feet above the roof200 square feetNot listedNot listedNot listedUpon or over the roof or parapet of any buildingNot listedUnlock17.25(6)(d)

Residential Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Show Window or Door Sign2 feetNot listed10 feetNot listedNot listedOver show windows or doors of a nonconforming business establishmentNot listedUnlock17.25(5)(a)
Real Estate SignNot listed8 square feetNot listedNot listedNot listedTemporarily located on the premisesNot listedUnlock17.25(5)(b)
Name, Occupation and Warning SignNot listed2 square feetNot listedNot listedNot listedOn the premisesNot listedUnlock17.25(5)(c)
Bulletin BoardNot listed8 square feetNot listedNot listedNot listedOn the premisesNot listedUnlock17.25(5)(d)
Memorial SignNot listedNot listedNot listedNot listedNot listedAffixed flat against a structureNot listedUnlock17.25(5)(e)
Official SignNot listedNot listedNot listedNot listedNot listedAs requiredNot listedUnlock17.25(5)(f)
Temporary SignNot listedNot listedNot listedNot listedNot listedAs authorizedNot listedUnlock17.25(5)(g)
Temporary Real Estate SignNot listed100 square feetNot listedNot closer than 100 feet from any residenceOne per street frontageOn the development property premisesNot listedUnlock17.25(5)(h)

Commercial Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign20 feet above the mean center line street grade200 square feetNot listedNot listedNot listedExterior walls of buildingsNot listedUnlock17.25(6)(a)
Projecting Sign20 feet above the mean center line street grade100 square feetNot listedShall not be less than 10 feet from all side lot linesNot listedFastened to, suspended from or supported by structuresNot listedUnlock17.25(6)(b)
Ground Sign20 feet above the mean center line street grade200 square feet on all sidesNot listedNot listedNot listedOn the ground, meeting all yard requirementsNot listedUnlock17.25(6)(c)
Roof Sign10 feet above the roof200 square feetNot listedNot listedNot listedUpon or over the roof or parapet of any buildingNot listedUnlock17.25(6)(d)

PermitPal covers all 4 zoning districts in Dresser. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Dresser

  • No sign shall be located, erected, moved, reconstructed, extended, enlarged or structurally altered without a building permit.
  • No sign shall be located, moved, erected, extended, enlarged or structurally altered without a sign permit.
  • Signs shall not resemble, imitate or approximate the shape, size, form or color of railroad or traffic signs, signals or devices.
  • Signs shall not obstruct or interfere with the effectiveness of railroad or traffic signs, signals or devices.
  • No sign shall be erected, relocated or maintained so as to prevent free ingress or egress from any door, window or fire escape.
  • No sign shall be attached to a standpipe or fire escape.
  • No sign shall be placed so as to obstruct or interfere with traffic visibility.
  • Off-premises signs, including billboards and movable free standing signs, are prohibited.
  • No sign shall be placed in any public right-of-way or publicly owned property except publicly owned signs such as traffic control signs and directional signs.
  • Signs may not project into the public right-of-way or adjoining parcels.
  • No sign shall be erected that has any flashing, rotating or brilliant intermittent parts or lights or bare reflecting bulbs except those giving public service information.
  • Wind signs shall be prohibited.
  • Portable trailer signs and signboards shall be prohibited.

Exempt Signs in Dresser

  • Governmental signs erected and maintained pursuant to and in discharge of any governmental function or required by law, ordinance or governmental regulation are excluded.
  • National, State or local government flags or the official flag of any institution or business shall not be considered as wind signs.

Sign Plan & Submission Notes for Dresser

  • Signs promoting community, service, fraternal or youth organizations that are specifically approved by the Plan Commission are exceptions to the prohibition of signs in the public right-of-way.

Source: ecode360 municipal code