Sign Regulations in Slinger, Wisconsin
Slinger, Wisconsin has specific sign regulations covering 8 sign types across 10 zoning districts. Regulated sign types include Wall Sign, Freestanding Ground Sign, Temporary Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Slinger, Wisconsin
Sample Sign Requirements in Slinger
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign | Not listed | 40 square feet | Not listed |
| Freestanding Ground Sign | 15 feet | 50 square feet | Minimum setback of 10 feet from property line or driveway. |
| Projecting Sign | Top of the wall | 16 square feet | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
8
- Wall Sign
- Freestanding Ground Sign
- Temporary Sign
- Projecting Sign
- +2 more types
Zoning Districts
10
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Slinger
Other Cities in Wisconsin
Frequently Asked Questions
In Slinger, the height limit for Freestanding Ground Sign is 15 feet (Sec. 550-61D(2)). Maximum sign heights range from 7 feet to 48 inches across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Slinger require a permit. We haven't published Slinger's application steps on this page yet. Run a code check for an exact address to see the permit requirements for that zone.
Slinger's sign code covers 8 sign types, including Wall Sign, Freestanding Ground Sign, Temporary Sign, and Projecting Sign. Most commercial signs need a permit. The ordinance lists 14 exemptions. One of them: Nonilluminated signs painted on canopies, awnings and marquees. The full list is on this page.
This page doesn't list a single setback distance for signs in Slinger. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Rules in Slinger's sign ordinance that cover digital, changing, or flashing signs: Flashing or rotating signs, signs containing moving parts and signs containing reflective elements that sparkle or twinkle in the sunlight are not permitted except as may otherwise be provided for elsewhere in this article. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Slinger Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Slinger, Wisconsin, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Slinger, Wisconsin Sign Rules at a Glance
Slinger, Wisconsin regulates 8 sign types across 10 zoning districts. Freestanding Ground Signs are capped at 15 feet tall and 50 square feet (Sec. 550-61D(2)). Most commercial signs in Slinger require a permit.
Detailed Sign Ordinance Requirements for Slinger, Wisconsin
Sign Rules by Zoning District in Slinger (10 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 6 | 48 inches | 50 square feet | Not listed |
| Village Center Downtown (VC-D) | 6 | 48 inches | 32 square feet | Not listed |
| Agricultural Transition District (A-1) | 1 | Not listed | 15 square feet | Not listed |
| Residential Districts (R-1, R-2, R-3, R-4, R-5, R-6, Rd-1, Rm-1, Rm-2, Mh-1) | 2 | 7 feet | 9 square feet | Not listed |
| Business Districts (B-2, B-3) | 3 | 15 feet | 50 square feet | Not listed |
| Industrial Districts (I-1, M-1, M-2) | 3 | 15 feet | 50 square feet | Not listed |
| Planned Unit Development (PUD) | 3 | 15 feet | 50 square feet | Not listed |
| Nonresidential Mixed-Use and PUD Properties | 3 | 15 feet | 50 square feet | Not listed |
| Contiguous Project/Development Area | 1 | 10 feet | 40 square feet | Not listed |
| Nonresidential Multiple-Tenant Buildings | 1 | Not listed | 30 square feet | Not listed |
Zone-by-Zone Sign Requirements in Slinger(sample of 3 of 10 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 40 square feet | Not listed | Not listed | One wall sign per principal building, except for multiple tenant buildings and buildings fronting two or more streets. | On the outermost wall of any principal building | Not listed | Unlock | § 550-61D(1) |
| Freestanding Ground Sign | 15 feet | 50 square feet | Not listed | Minimum setback of 10 feet from property line or driveway. | One freestanding ground/monument type sign per principal building, except for buildings abutting two or more streets. | Not closer than 10 feet to any property line or driveway, except in VC-D where the minimum required setback is five feet. | Not listed | Unlock | § 550-61D(2) |
| Projecting Sign | Top of the wall | 16 square feet | Not listed | Not listed | One projecting sign per principal building or individual tenant occupant. | Shall not extend more than five feet over the lot line and in no case shall extend to within five feet of the back of curb. | Not listed | Unlock | § 550-61D(4) |
| Awning, Canopy, and Marquee Sign | Minimum clearance to grade beneath the awning, canopy or marquee shall be eight feet. | 30 square feet | Not listed | Not listed | Not more than one awning, canopy or marquee sign exceeding an aggregate gross surface area of four square feet per principal building or individual tenant occupant. | Not closer than two feet to the back of curb. | Not listed | Unlock | § 550-61D(5) |
| Window Sign | Not listed | 50% of the glass area of the window | Not listed | Not listed | One neon or LED illuminated sign per public street frontage during business hours. | On the window | Not listed | Unlock | § 550-61D(6) |
| Sandwich Board Sign | 48 inches | 8 square feet per side | Not listed | Not listed | One sandwich board sign per building or tenant occupant space. | Not more than 10 feet from the front primary entrance of the building or tenant occupant space. | Not listed | Unlock | § 550-61D(9) |
Village Center Downtown (VC-D)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 32 square feet | Not listed | Not listed | One wall sign per principal building, except for multiple tenant buildings and buildings fronting two or more streets. | On the outermost wall of any principal building | Not listed | Unlock | § 550-61D(1) |
| Freestanding Ground Sign | 15 feet | 32 square feet | Not listed | Minimum setback of 5 feet from property line or driveway. | One freestanding ground/monument type sign per principal building, except for buildings abutting two or more streets. | Not closer than five feet to any property line or driveway. | Not listed | Unlock | § 550-61D(2) |
| Projecting Sign | Top of the wall | 16 square feet | Not listed | Not listed | One projecting sign per principal building or individual tenant occupant. | Shall not extend more than five feet over the lot line and in no case shall extend to within five feet of the back of curb. | Not listed | Unlock | § 550-61D(4) |
| Awning, Canopy, and Marquee Sign | Minimum clearance to grade beneath the awning, canopy or marquee shall be eight feet. | 30 square feet | Not listed | Not listed | Not more than one awning, canopy or marquee sign exceeding an aggregate gross surface area of four square feet per principal building or individual tenant occupant. | Not closer than two feet to the back of curb. | Not listed | Unlock | § 550-61D(5) |
| Window Sign | Not listed | 25% of the glass area of the window | Not listed | Not listed | One neon or LED illuminated sign per public street frontage during business hours. | On the window | Not listed | Unlock | § 550-61D(6) |
| Sandwich Board Sign | 48 inches | 8 square feet per side | Not listed | Not listed | One sandwich board sign per building or tenant occupant space. | Not more than 10 feet from the front primary entrance of the building or tenant occupant space. | Not listed | Unlock | § 550-61D(9) |
Business Districts (B-2, B-3)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 40 square feet | Not listed | Not listed | One wall sign per principal building, except for multiple tenant buildings and buildings fronting two or more streets. | On the outermost wall of any principal building | Not listed | Unlock | § 550-61D(1) |
| Freestanding Ground Sign | 15 feet | 50 square feet | Not listed | Minimum setback of 10 feet from property line or driveway. | One freestanding ground/monument type sign per principal building, except for buildings abutting two or more streets. | Not closer than 10 feet to any property line or driveway. | Not listed | Unlock | § 550-61D(2) |
| Temporary Sign | 10 feet | 15 square feet | Not listed | Not listed | Up to four temporary signs per property. | On nonresidentially zoned or used properties. | Not listed | Unlock | § 550-57A(12) |
PermitPal covers all 10 zoning districts in Slinger. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Slinger
- Roof signs.
- Signs placed on or affixed to vehicles and/or trailers which are parked on a public right-of-way, public property or private property so as to be visible from a public right-of-way where the apparent primary use/purpose of the vehicle or trailer is to display signage.
- Signs that are attached or otherwise affixed to trees or other living vegetation.
- Flashing or rotating signs, signs containing moving parts and signs containing reflective elements that sparkle or twinkle in the sunlight are not permitted except as may otherwise be provided for elsewhere in this article.
- A-frame, sandwich board, sidewalk, or curb signs, except as provided for in § 550-56.6d(8) below.
- Banners, pennants, streamers, balloons and other gas-filled figures, except as a temporary sign.
- Off-premises signs except Village approved temporary off-premises signs used to identify businesses whose accessibility and/or visibility is being adversely affected during road, utility or similar construction.
- Any sign advertising or identifying a business or organization that is either defunct or no longer located on the premises where the sign is located.
- Portable and wheeled signs except as may otherwise be provided for in this article.
- Signs or other advertising painted directly on building walls or fences unless specifically approved by the Planning Commission.
- Inflatable signs and tethered balloons except as may be permitted as temporary signs.
- Signs erected at or near the intersection of any streets, driveways or railroad crossings in such manner as to obstruct free and clear vision by motorists or pedestrians of oncoming traffic; or at any location where, by reason of the position, shape or color, it may interfere with, obstruct the view of, imitate or be confused with any authorized traffic sign, signal or device.
Exempt Signs in Slinger
- One wall sign not to exceed six square feet in size maintained by the owner or occupant of any unit in residentially occupied building containing three or fewer residential dwelling units.
- Public informational bulletin boards not more than 15 square feet in size provided by the Village or similar governmental or quasi-governmental organization and placed upon public property, Village-owned property and or the public right-of-way (or upon private property with the express written consent of the underlying property owner) for purposes of making public announcements and information most readily available to the public, including as may be required by law.
- Memorial signs or tablets recording names of buildings and date of erection, when cut into any masonry surface of the building or when constructed of metal or other noncombustible materials and permanently affixed to the building.
- Traffic signs, legal notices, railroad crossing signs, danger and such temporary emergency or nonadvertising signs as may be erected for the public safety.
- Nonilluminated signs painted on canopies, awnings and marquees.
- One freestanding sign up to 15 square feet in area and setback at least 10 feet from the edge of the public right-of-way on parcels where an active and permitted agricultural use is present on the premises and the property is zoned A-1 Agricultural Transition District.
- Up to one United States flag, State of Wisconsin flag, Washington County Wisconsin flag, and/or a flag bearing the official emblem or insignia of the Village of Slinger, as well as up to one flag bearing the official emblem or insignia of the six official branches of the U.S. Military.
- Special decorative 'Village of Slinger' and/or directional or promotional displays or signs in public right-of-way provided such signs are owned, installed and maintained by the Village.
- Signs which are located within the interior of any building and which are not visible from the exterior of the building.
- Miscellaneous temporary signs on residentially zoned and/or residentially used properties provided that no person shall attach posters, notices or signs to utility poles, meter posts, or trees in or along any street right-of-way within the Village.
- In the case of residentially zoned or residentially used properties being actively marketed for sale or lease, the duration for display of up to two (out of the four signs referred to above) may be extended to include the period that begins when the property becomes actively marketed for sale or lease and ends 14 days after the property has been sold or leased.
- Miscellaneous temporary signs on nonresidentially zoned or used properties and/or mixed use and PUD properties provided that no person shall attach posters, notices or signs to utility poles, meter posts, or trees in or along any street right-of-way within the Village.
- In the case of properties being actively marketed for sale or lease, the duration for display of up to two (out of the four miscellaneous temporary signs referred to above) may be extended to include the period that begins when the property becomes actively marketed for sale or lease and ends 14 days after the property has been sold or leased.
- Temporary signs displayed on parks and schools properties shall be viewed as part of a single comprehensive temporary sign display per property and shall be subject to prior review and approval by the SCA and/or Village Planning Commission each time this single comprehensive temporary sign display is substantially modified in any way.
Sign Plan & Submission Notes for Slinger
- Master sign plan approval. All new multiple-tenant buildings, mixed use developments and/or Planned Unit Developments (PUDs) are required to develop a master sign plan for that building/development depicting the design, dimensions, location, materials, content, color scheme, type of illumination, if any, method of construction and manor of attachment for all signs planned to be installed on the building and property (based upon anticipated full occupancy). Such plan shall be submitted for review and approval by the Planning Commission prior to the issuance of any sign permits in that building/development.
Source: ecode360 municipal code