Questions? Call us at (262) 218-2915

Sign Regulations in Alabaster, Alabama

Alabaster, Alabama has specific sign regulations covering 30 sign types across 24 zoning districts. Regulated sign types include Signs (General), Wall Sign, Subdivision Entrance Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 7, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Alabaster, Alabama

Sample Sign Requirements in Alabaster

Sign TypeMax HeightMax AreaSetback
Subdivision Entrance Sign6 ft32 sq ftNot listed
Freestanding Sign (Special Exception Uses)4 ft24 sq ftNot listed
Wall Sign (Special Exception Uses)Not listed24 sq ftNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for AlabasterFull Coverage

Sign Types Covered

30

  • Signs (General)
  • Wall Sign
  • Subdivision Entrance Sign
  • Freestanding Sign
  • +2 more types

Zoning Districts

24

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Alabaster

City WebsiteMunicipal Code5 permit application links available

Frequently Asked Questions

In Alabaster, the height limit for Industrial Park Freestanding Sign (abutting Interstate Highway 65) in the M-1 Light Industrial District, M-2 Heavy Industrial District is 50 ft (Sec. 111-227(5)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Alabaster require a permit. From the submission notes on this page: Sign permit applications must include specific information, including engineered drawings for certain sizes/heights, and are subject to denial with written explanation. Run a code check for an exact address to see the permit requirements for that zone.

Alabaster's sign code covers 30 sign types, including Signs (General), Wall Sign, Subdivision Entrance Sign, and Freestanding Sign. Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Changing of the advertising copy of a message on an existing approved sign or marquee specifically designed for the use of replaceable copy is permitted and exempt from permit requirements. The full list is on this page.

In Alabaster, Freestanding Sign (Interstate Highway 65 abutting lots, building on at least 5 acres) in the M-1 Light Industrial District, M-2 Heavy Industrial District must be set back at least 100 ft from right-of-way (Sec. 111-227(4)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Alabaster's sign ordinance that cover digital, changing, or flashing signs: Except as permitted under section 111-235, animated signs, including signs which move, revolve, rotate or appear animated by mechanical, electronic or other means, are prohibited. Except as permitted under section 111-235, signs with flashing, blinking, moving or intermittent light or with light which varies in intensity or color, except time and temperature signs, are prohibited. Painting, cleaning or other normal maintenance and repair of a sign not involving structural, electronic, or electrical changes is permitted and exempt from permit requirements. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Alabaster Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Alabaster, Alabama, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Alabaster, Alabama Sign Rules at a Glance

Alabaster, Alabama regulates 30 sign types across 24 zoning districts. Freestanding Signs (Interstate Highway 65 abutting lots, building on at least 5 acres) in the M-1 Light Industrial District, M-2 Heavy Industrial District are capped at 35 ft tall and 240 sq ft, set back at least 100 ft from right-of-way (Sec. 111-227(4)). Most commercial signs in Alabaster require a permit.

Detailed Sign Ordinance Requirements for Alabaster, Alabama

Sign Rules by Zoning District in Alabaster (24 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
A Agriculture District, E Single-Family Estate Residential District, R-1 Single-Family Residential District, R-2 Single-Family Residential District, R-3 Single-Family Residential District, R-4 Residential Patio/Garden Home District, R-5 Two-Family Residential District, R-7 Townhouse District, R-8 Manufactured and Mobile Home Residential District46 ft32 sq ftNot listed
R-6 Multifamily District18 ft32 sq ftNot listed
MHD Manufactured and Mobile Home Park and Subdivision District18 ft32 sq ftNot listed
I Institution District, B-1 Office District64 ft48 sq ftNot listed
I Institution District, B-1 Office District (Multiple Buildings)14 ft32 sq ft (internally illuminated); 48 sq ft (nonilluminated/indirect); 48 sq ft (internally illuminated for >500,000 sq ft campus); 72 sq ft (nonilluminated/indirect for >500,000 sq ft campus)Not listed
B-2 Neighborhood Business District, B-4 General Business District520 ft (main sign), 10 ft (additional corner sign)120 sq ft (main sign), 48 sq ft (additional corner sign - monument style)Not listed
B-3 Community Business District840 ft (under 30,000 sq ft); 45 ft (over 30,000 sq ft); Top of building wall for wall/canopy200 sq ft (total for Option 2 per lot)Not listed
B-5 Central Business District3Not listed32 sq ftNot listed
M-1 Light Industrial District, M-2 Heavy Industrial District850 ft400 sq ftNot listed
PDD Planned Development District112 ft or maximum permitted by subject district, whichever is less (for freestanding signs)Not listedNot listed
MXD Mixed Use District1Not listedNot listedNot listed
PCD-1 Planned Neighborhood Commercial District1Per B-2 Neighborhood Business DistrictPer B-2 Neighborhood Business DistrictNot listed
PCD-2 Planned Commercial District1Per B-3 Community Business DistrictPer B-3 Community Business DistrictNot listed
POD Planned Office and Institution District1Per I Institution and B-1 Office District sign regulationsPer I Institution and B-1 Office District sign regulationsNot listed
PRD-1 Planned Single-Family Residential District16 ft32 sq ftNot listed
PRD-2 Planned Attached Residential District1See R-5, R-6, R-7, as applicable per projectSee R-5, R-6, R-7, as applicable per projectNot listed
PID Planned Industrial District1Per M-1 district regulationsPer M-1 district regulationsNot listed
MR Municipal Reserve District1Not listedNot listedNot listed
MOD Mountain Overlay District1Not listedNot listedNot listed
PCO Peavine Creek Overlay District1Not listedNot listedNot listed
Medical Mile Overlay District1Not listedNot listedNot listed
State Route 119 Overlay District1Not listedNot listedNot listed
CO Conditional Overlay District1Not listedNot listedNot listed
Aria at Siluria Active Adult Community MXD District1Not listedNot specified; subject to MXD reviewNot listed

Zone-by-Zone Sign Requirements in Alabaster(sample of 3 of 24 zones)

I Institution District, B-1 Office District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign (under 20,000 sq ft building)4 ft32 sq ftNot listedNot listedOne per lotIn front of buildingNot listedUnlockSec. 111-224(a)(1)
Wall Sign or Canopy Sign (under 20,000 sq ft building)Not listed20 sq ft per visible street frontNot listedNot listedOne per visible street frontEach visible street frontNot listedUnlockSec. 111-224(a)(1)
Freestanding Sign (20,000 to <100,000 sq ft building)4 ft32 sq ftNot listedNot listedOne per lotIn front of buildingNot listedUnlockSec. 111-224(a)(2)
Wall Sign or Canopy Sign (20,000 to <100,000 sq ft building)Not listed30 sq ft per visible street frontNot listedNot listedOne per visible street frontEach visible street frontNot listedUnlockSec. 111-224(a)(2)
Freestanding Sign (100,000 sq ft or greater building)4 ft48 sq ftNot listedNot listedOne per lotIn front of buildingNot listedUnlockSec. 111-224(a)(3)
Wall Sign or Canopy Sign (100,000 sq ft or greater building)Not listed40 sq ft per visible street frontNot listedNot listedOne per visible street frontEach visible street frontNot listedUnlockSec. 111-224(a)(3)

B-3 Community Business District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign - Option 120 ft48 sq ftNot listedNot listedOne per qualifying lotLot or parcel w/150 ft of continuous frontageNot listedUnlockSec. 111-225(b)(2)
Freestanding Sign - Option 2 (Monument Sign)10 ft60 sq ftNot listedNot listedOne per qualifying lotLot or parcel w/150 ft of continuous frontageNot listedUnlockSec. 111-225(b)(2)
Wall SignNot listed200 sq ft (total for Option 2 per lot)Not listedNot listedOne per facing streetEach facing streetNot listedUnlockSec. 111-225(b)(2)
Shopping Center Freestanding Identification Sign30 ft (main sign), 10 ft (corner sign), 70 ft (I-65)120 sq ft/main sign, 48 sq ft/corner monument sign, or 240 sq ft if facing I-65Not listedNot listedSee aboveAs describedNot listedUnlockSec. 111-225(b)(4)
Shopping Center Tenant Wall SignNot listedNot listedNot listedNot listedOne per street wallEach establishment in shopping centerNot listedUnlockSec. 111-225(b)(3)
Gas Station Canopy SignNot listedNot listedNot listedNot listedTwo sides per canopyOn gas station canopyNot listedUnlockSec. 111-225(b)(5)a
Gas Station Pump Island SignNot listed12 sq ft per pump island (spandrels)Not listedNot listedPer pump islandOn pump island spandrelNot listedUnlockSec. 111-225(b)(5)b
Auto Dealership Signs (B-3 district, see table)40 ft (under 30,000 sq ft); 45 ft (over 30,000 sq ft); Top of building wall for wall/canopyBuilding wall/canopy sign: 100 sq ft (both under and over 30,000 sq ft floor area); Freestanding sign: 220 sq ft (under 30,000 sq ft), 380 sq ft (over 30,000 sq ft) *see restrictions; max allowed on freestanding sign = 260 sq ftNot listedNot listedFreestanding sign: 3 allowed; see restrictions for additional franchisesOn building wall/canopy or as freestanding signNot listedUnlockSec. 111-225(b)(6)

M-1 Light Industrial District, M-2 Heavy Industrial District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign (building < 20,000 sq ft)4 ft32 sq ftNot listedNot listedOne per buildingIn front of buildingNot listedUnlockSec. 111-227(1)
Wall SignNot listed150 sq ft (total wall signage for < 20,000 sq ft bld)Not listedNot listedNot listedBuilding wallNot listedUnlockSec. 111-227(1)
Freestanding Sign (20,000 to <100,000 sq ft bld)6 ft48 sq ftNot listedNot listedOne per buildingIn front of buildingNot listedUnlockSec. 111-227(2)
Wall Sign (20,000 to <100,000 sq ft bld)Not listed200 sq ft (total)Not listedNot listedNot listedBuilding wallNot listedUnlockSec. 111-227(2)
Freestanding Sign (100,000 sq ft or greater bld)6 ft60 sq ftNot listedNot listedOne per buildingIn front of buildingNot listedUnlockSec. 111-227(3)
Wall Sign (100,000 sq ft or greater bld)Not listed300 sq ft (total)Not listedNot listedNot listedBuilding wallNot listedUnlockSec. 111-227(3)
Freestanding Sign (Interstate Highway 65 abutting lots, building on at least 5 acres)35 ft240 sq ftNot listedAt least 100 ft from right-of-wayOne per qualifying lotOn lots abutting Interstate Highway 65, bld on ≥5 acresNot listedUnlockSec. 111-227(4)
Industrial Park Freestanding Sign (abutting Interstate Highway 65)50 ft400 sq ftNot listedNot listedOne per qualifying parkIndustrial park abutting I-65Not listedUnlockSec. 111-227(5)

PermitPal covers all 24 zoning districts in Alabaster. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Alabaster

  • It is unlawful to erect, construct, enlarge, move, alter or convert any sign in the city, or cause the same to be done, without first obtaining a building permit for each sign from the building official, except as otherwise provided.
  • Portable signs and any other signs which are not permanently attached to the ground or a building are prohibited, except for those expressly permitted as 'temporary signs' under section 111-233(c).
  • Signs located in the public right-of-way are prohibited, except those specifically permitted in accordance with section 111-230.
  • Signs attached to trees, utility poles or other structures located in the public right-of-way are prohibited, except for instructional signs posted by the owner of a pole or other structure.
  • Except as permitted under section 111-235, animated signs, including signs which move, revolve, rotate or appear animated by mechanical, electronic or other means, are prohibited.
  • Except as permitted under section 111-235, signs with flashing, blinking, moving or intermittent light or with light which varies in intensity or color, except time and temperature signs, are prohibited.
  • Strings of light bulbs, inflatable signs and signs which emit noise, odor or visible matter such as smoke or steam are prohibited.
  • Banners are prohibited except as permitted in section 111-233(c) of this article.
  • Wind-driven signs including pennants, ribbons, spinners, streamers, captive balloons and similar devices are prohibited; this restriction does not apply to flags permitted in accordance with section 111-233(b)(1).
  • Roof signs are prohibited.
  • Off-premises signs are prohibited, except as permitted in section 111-230.
  • Signs which do not comply with the adopted building, electrical or fire codes are prohibited.
  • Any sign which constitutes a safety hazard, including signs which obstruct visibility at intersections, are prohibited.

Exempt Signs in Alabaster

  • Changing of the advertising copy of a message on an existing approved sign or marquee specifically designed for the use of replaceable copy is permitted and exempt from permit requirements.
  • Painting, cleaning or other normal maintenance and repair of a sign not involving structural, electronic, or electrical changes is permitted and exempt from permit requirements.
  • Construction signs, instructional signs, the American flag, governmental signs, holiday decorations, interior signs, plaques, public notices, symbols or insignias, for sale or lease signs located on the premises, warning signs, and signs awarded by the city beautification board are exempt signs.
  • Directional signs which do not exceed four square feet of sign face area, nor three feet in height and are placed and removed within 24 hours of the event are exempt signs. Directional signs are not permitted in the right-of-way.
  • Signs which are incorporated into vending machines by a manufacturer or distributor, which identify or advertise only the product or service dispensed by the machine, are exempt signs.
  • Political campaign signs, subject to listed restrictions, are exempt signs.
  • Temporary signs as set out in section 111-233(c)(7) and (8) are permitted.
  • Routine maintenance of signs, as specified, does not require a permit.

Sign Plan & Submission Notes for Alabaster

  • A sign permit is required for the erection, construction, enlargement, moving, alteration or conversion of any sign, unless explicitly exempted.
  • Sign permit applications must include specific information, including engineered drawings for certain sizes/heights, and are subject to denial with written explanation.
  • Appeals of permit denials may be taken to the board of zoning adjustment.
  • In the MXD Mixed Use District, requirements for signs shall be established for each mixed use development as part of the development plan review process, and this article does not apply.
  • For special exception uses, a site plan is required that must show locations of exterior lighting and signs.
  • A master sign plan or similar is not explicitly referenced as required city-wide; however, individual development types or districts such as Planned Development Districts and Mixed Use Developments require a signage plan or establish sign standards as part of their development/development plan approval process.
  • Sign variance requests follow the standard board of zoning adjustment process, requiring an application and review at variance meetings.

Source: municode municipal code