Sign Regulations in Alabaster, Alabama
Alabaster, Alabama has specific sign regulations covering 30 sign types across 24 zoning districts. Regulated sign types include Signs (General), Wall Sign, Subdivision Entrance Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Alabaster, Alabama
Sample Sign Requirements in Alabaster
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Subdivision Entrance Sign | 6 ft | 32 sq ft | Not listed |
| Freestanding Sign (Special Exception Uses) | 4 ft | 24 sq ft | Not listed |
| Wall Sign (Special Exception Uses) | Not listed | 24 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
30
- Signs (General)
- Wall Sign
- Subdivision Entrance Sign
- Freestanding Sign
- +2 more types
Zoning Districts
24
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Alabaster
Other Cities in Alabama
Frequently Asked Questions
In Alabaster, the height limit for Industrial Park Freestanding Sign (abutting Interstate Highway 65) in the M-1 Light Industrial District, M-2 Heavy Industrial District is 50 ft (Sec. 111-227(5)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Alabaster require a permit. From the submission notes on this page: Sign permit applications must include specific information, including engineered drawings for certain sizes/heights, and are subject to denial with written explanation. Run a code check for an exact address to see the permit requirements for that zone.
Alabaster's sign code covers 30 sign types, including Signs (General), Wall Sign, Subdivision Entrance Sign, and Freestanding Sign. Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Changing of the advertising copy of a message on an existing approved sign or marquee specifically designed for the use of replaceable copy is permitted and exempt from permit requirements. The full list is on this page.
In Alabaster, Freestanding Sign (Interstate Highway 65 abutting lots, building on at least 5 acres) in the M-1 Light Industrial District, M-2 Heavy Industrial District must be set back at least 100 ft from right-of-way (Sec. 111-227(4)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Alabaster's sign ordinance that cover digital, changing, or flashing signs: Except as permitted under section 111-235, animated signs, including signs which move, revolve, rotate or appear animated by mechanical, electronic or other means, are prohibited. Except as permitted under section 111-235, signs with flashing, blinking, moving or intermittent light or with light which varies in intensity or color, except time and temperature signs, are prohibited. Painting, cleaning or other normal maintenance and repair of a sign not involving structural, electronic, or electrical changes is permitted and exempt from permit requirements. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Alabaster Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Alabaster, Alabama, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Alabaster, Alabama Sign Rules at a Glance
Alabaster, Alabama regulates 30 sign types across 24 zoning districts. Freestanding Signs (Interstate Highway 65 abutting lots, building on at least 5 acres) in the M-1 Light Industrial District, M-2 Heavy Industrial District are capped at 35 ft tall and 240 sq ft, set back at least 100 ft from right-of-way (Sec. 111-227(4)). Most commercial signs in Alabaster require a permit.
Detailed Sign Ordinance Requirements for Alabaster, Alabama
Sign Rules by Zoning District in Alabaster (24 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| A Agriculture District, E Single-Family Estate Residential District, R-1 Single-Family Residential District, R-2 Single-Family Residential District, R-3 Single-Family Residential District, R-4 Residential Patio/Garden Home District, R-5 Two-Family Residential District, R-7 Townhouse District, R-8 Manufactured and Mobile Home Residential District | 4 | 6 ft | 32 sq ft | Not listed |
| R-6 Multifamily District | 1 | 8 ft | 32 sq ft | Not listed |
| MHD Manufactured and Mobile Home Park and Subdivision District | 1 | 8 ft | 32 sq ft | Not listed |
| I Institution District, B-1 Office District | 6 | 4 ft | 48 sq ft | Not listed |
| I Institution District, B-1 Office District (Multiple Buildings) | 1 | 4 ft | 32 sq ft (internally illuminated); 48 sq ft (nonilluminated/indirect); 48 sq ft (internally illuminated for >500,000 sq ft campus); 72 sq ft (nonilluminated/indirect for >500,000 sq ft campus) | Not listed |
| B-2 Neighborhood Business District, B-4 General Business District | 5 | 20 ft (main sign), 10 ft (additional corner sign) | 120 sq ft (main sign), 48 sq ft (additional corner sign - monument style) | Not listed |
| B-3 Community Business District | 8 | 40 ft (under 30,000 sq ft); 45 ft (over 30,000 sq ft); Top of building wall for wall/canopy | 200 sq ft (total for Option 2 per lot) | Not listed |
| B-5 Central Business District | 3 | Not listed | 32 sq ft | Not listed |
| M-1 Light Industrial District, M-2 Heavy Industrial District | 8 | 50 ft | 400 sq ft | Not listed |
| PDD Planned Development District | 1 | 12 ft or maximum permitted by subject district, whichever is less (for freestanding signs) | Not listed | Not listed |
| MXD Mixed Use District | 1 | Not listed | Not listed | Not listed |
| PCD-1 Planned Neighborhood Commercial District | 1 | Per B-2 Neighborhood Business District | Per B-2 Neighborhood Business District | Not listed |
| PCD-2 Planned Commercial District | 1 | Per B-3 Community Business District | Per B-3 Community Business District | Not listed |
| POD Planned Office and Institution District | 1 | Per I Institution and B-1 Office District sign regulations | Per I Institution and B-1 Office District sign regulations | Not listed |
| PRD-1 Planned Single-Family Residential District | 1 | 6 ft | 32 sq ft | Not listed |
| PRD-2 Planned Attached Residential District | 1 | See R-5, R-6, R-7, as applicable per project | See R-5, R-6, R-7, as applicable per project | Not listed |
| PID Planned Industrial District | 1 | Per M-1 district regulations | Per M-1 district regulations | Not listed |
| MR Municipal Reserve District | 1 | Not listed | Not listed | Not listed |
| MOD Mountain Overlay District | 1 | Not listed | Not listed | Not listed |
| PCO Peavine Creek Overlay District | 1 | Not listed | Not listed | Not listed |
| Medical Mile Overlay District | 1 | Not listed | Not listed | Not listed |
| State Route 119 Overlay District | 1 | Not listed | Not listed | Not listed |
| CO Conditional Overlay District | 1 | Not listed | Not listed | Not listed |
| Aria at Siluria Active Adult Community MXD District | 1 | Not listed | Not specified; subject to MXD review | Not listed |
Zone-by-Zone Sign Requirements in Alabaster(sample of 3 of 24 zones)
I Institution District, B-1 Office District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign (under 20,000 sq ft building) | 4 ft | 32 sq ft | Not listed | Not listed | One per lot | In front of building | Not listed | Unlock | Sec. 111-224(a)(1) |
| Wall Sign or Canopy Sign (under 20,000 sq ft building) | Not listed | 20 sq ft per visible street front | Not listed | Not listed | One per visible street front | Each visible street front | Not listed | Unlock | Sec. 111-224(a)(1) |
| Freestanding Sign (20,000 to <100,000 sq ft building) | 4 ft | 32 sq ft | Not listed | Not listed | One per lot | In front of building | Not listed | Unlock | Sec. 111-224(a)(2) |
| Wall Sign or Canopy Sign (20,000 to <100,000 sq ft building) | Not listed | 30 sq ft per visible street front | Not listed | Not listed | One per visible street front | Each visible street front | Not listed | Unlock | Sec. 111-224(a)(2) |
| Freestanding Sign (100,000 sq ft or greater building) | 4 ft | 48 sq ft | Not listed | Not listed | One per lot | In front of building | Not listed | Unlock | Sec. 111-224(a)(3) |
| Wall Sign or Canopy Sign (100,000 sq ft or greater building) | Not listed | 40 sq ft per visible street front | Not listed | Not listed | One per visible street front | Each visible street front | Not listed | Unlock | Sec. 111-224(a)(3) |
B-3 Community Business District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign - Option 1 | 20 ft | 48 sq ft | Not listed | Not listed | One per qualifying lot | Lot or parcel w/150 ft of continuous frontage | Not listed | Unlock | Sec. 111-225(b)(2) |
| Freestanding Sign - Option 2 (Monument Sign) | 10 ft | 60 sq ft | Not listed | Not listed | One per qualifying lot | Lot or parcel w/150 ft of continuous frontage | Not listed | Unlock | Sec. 111-225(b)(2) |
| Wall Sign | Not listed | 200 sq ft (total for Option 2 per lot) | Not listed | Not listed | One per facing street | Each facing street | Not listed | Unlock | Sec. 111-225(b)(2) |
| Shopping Center Freestanding Identification Sign | 30 ft (main sign), 10 ft (corner sign), 70 ft (I-65) | 120 sq ft/main sign, 48 sq ft/corner monument sign, or 240 sq ft if facing I-65 | Not listed | Not listed | See above | As described | Not listed | Unlock | Sec. 111-225(b)(4) |
| Shopping Center Tenant Wall Sign | Not listed | Not listed | Not listed | Not listed | One per street wall | Each establishment in shopping center | Not listed | Unlock | Sec. 111-225(b)(3) |
| Gas Station Canopy Sign | Not listed | Not listed | Not listed | Not listed | Two sides per canopy | On gas station canopy | Not listed | Unlock | Sec. 111-225(b)(5)a |
| Gas Station Pump Island Sign | Not listed | 12 sq ft per pump island (spandrels) | Not listed | Not listed | Per pump island | On pump island spandrel | Not listed | Unlock | Sec. 111-225(b)(5)b |
| Auto Dealership Signs (B-3 district, see table) | 40 ft (under 30,000 sq ft); 45 ft (over 30,000 sq ft); Top of building wall for wall/canopy | Building wall/canopy sign: 100 sq ft (both under and over 30,000 sq ft floor area); Freestanding sign: 220 sq ft (under 30,000 sq ft), 380 sq ft (over 30,000 sq ft) *see restrictions; max allowed on freestanding sign = 260 sq ft | Not listed | Not listed | Freestanding sign: 3 allowed; see restrictions for additional franchises | On building wall/canopy or as freestanding sign | Not listed | Unlock | Sec. 111-225(b)(6) |
M-1 Light Industrial District, M-2 Heavy Industrial District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign (building < 20,000 sq ft) | 4 ft | 32 sq ft | Not listed | Not listed | One per building | In front of building | Not listed | Unlock | Sec. 111-227(1) |
| Wall Sign | Not listed | 150 sq ft (total wall signage for < 20,000 sq ft bld) | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 111-227(1) |
| Freestanding Sign (20,000 to <100,000 sq ft bld) | 6 ft | 48 sq ft | Not listed | Not listed | One per building | In front of building | Not listed | Unlock | Sec. 111-227(2) |
| Wall Sign (20,000 to <100,000 sq ft bld) | Not listed | 200 sq ft (total) | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 111-227(2) |
| Freestanding Sign (100,000 sq ft or greater bld) | 6 ft | 60 sq ft | Not listed | Not listed | One per building | In front of building | Not listed | Unlock | Sec. 111-227(3) |
| Wall Sign (100,000 sq ft or greater bld) | Not listed | 300 sq ft (total) | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 111-227(3) |
| Freestanding Sign (Interstate Highway 65 abutting lots, building on at least 5 acres) | 35 ft | 240 sq ft | Not listed | At least 100 ft from right-of-way | One per qualifying lot | On lots abutting Interstate Highway 65, bld on ≥5 acres | Not listed | Unlock | Sec. 111-227(4) |
| Industrial Park Freestanding Sign (abutting Interstate Highway 65) | 50 ft | 400 sq ft | Not listed | Not listed | One per qualifying park | Industrial park abutting I-65 | Not listed | Unlock | Sec. 111-227(5) |
PermitPal covers all 24 zoning districts in Alabaster. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Alabaster
- It is unlawful to erect, construct, enlarge, move, alter or convert any sign in the city, or cause the same to be done, without first obtaining a building permit for each sign from the building official, except as otherwise provided.
- Portable signs and any other signs which are not permanently attached to the ground or a building are prohibited, except for those expressly permitted as 'temporary signs' under section 111-233(c).
- Signs located in the public right-of-way are prohibited, except those specifically permitted in accordance with section 111-230.
- Signs attached to trees, utility poles or other structures located in the public right-of-way are prohibited, except for instructional signs posted by the owner of a pole or other structure.
- Except as permitted under section 111-235, animated signs, including signs which move, revolve, rotate or appear animated by mechanical, electronic or other means, are prohibited.
- Except as permitted under section 111-235, signs with flashing, blinking, moving or intermittent light or with light which varies in intensity or color, except time and temperature signs, are prohibited.
- Strings of light bulbs, inflatable signs and signs which emit noise, odor or visible matter such as smoke or steam are prohibited.
- Banners are prohibited except as permitted in section 111-233(c) of this article.
- Wind-driven signs including pennants, ribbons, spinners, streamers, captive balloons and similar devices are prohibited; this restriction does not apply to flags permitted in accordance with section 111-233(b)(1).
- Roof signs are prohibited.
- Off-premises signs are prohibited, except as permitted in section 111-230.
- Signs which do not comply with the adopted building, electrical or fire codes are prohibited.
- Any sign which constitutes a safety hazard, including signs which obstruct visibility at intersections, are prohibited.
Exempt Signs in Alabaster
- Changing of the advertising copy of a message on an existing approved sign or marquee specifically designed for the use of replaceable copy is permitted and exempt from permit requirements.
- Painting, cleaning or other normal maintenance and repair of a sign not involving structural, electronic, or electrical changes is permitted and exempt from permit requirements.
- Construction signs, instructional signs, the American flag, governmental signs, holiday decorations, interior signs, plaques, public notices, symbols or insignias, for sale or lease signs located on the premises, warning signs, and signs awarded by the city beautification board are exempt signs.
- Directional signs which do not exceed four square feet of sign face area, nor three feet in height and are placed and removed within 24 hours of the event are exempt signs. Directional signs are not permitted in the right-of-way.
- Signs which are incorporated into vending machines by a manufacturer or distributor, which identify or advertise only the product or service dispensed by the machine, are exempt signs.
- Political campaign signs, subject to listed restrictions, are exempt signs.
- Temporary signs as set out in section 111-233(c)(7) and (8) are permitted.
- Routine maintenance of signs, as specified, does not require a permit.
Sign Plan & Submission Notes for Alabaster
- A sign permit is required for the erection, construction, enlargement, moving, alteration or conversion of any sign, unless explicitly exempted.
- Sign permit applications must include specific information, including engineered drawings for certain sizes/heights, and are subject to denial with written explanation.
- Appeals of permit denials may be taken to the board of zoning adjustment.
- In the MXD Mixed Use District, requirements for signs shall be established for each mixed use development as part of the development plan review process, and this article does not apply.
- For special exception uses, a site plan is required that must show locations of exterior lighting and signs.
- A master sign plan or similar is not explicitly referenced as required city-wide; however, individual development types or districts such as Planned Development Districts and Mixed Use Developments require a signage plan or establish sign standards as part of their development/development plan approval process.
- Sign variance requests follow the standard board of zoning adjustment process, requiring an application and review at variance meetings.