Trussville, Alabama has specific sign regulations covering 73 sign types across 35 zoning districts. Regulated sign types include Wall Sign, Monument Sign, Message Board/Reader Board (Accessory). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 27, 2026

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Trussville, Alabama

Sample Sign Requirements in Trussville

Sign TypeMax HeightMax AreaSetback
Any Sign Type - General Prohibitions and StandardsNot listedNot listedTypical monument/portable/temporary: ≥15' from pavement edge of public street/thoroughfare; no part in sight triangle (legs usually 75' along streets, 15' at driveways; larger where required by engineering).
Monument Sign4 ft at 15' setback; may increase up to 12 ft with 3 ft additional setback for each 1 ft over 4 ft32 sq ftMinimum 15' from pavement/roadway edge; add 3' of setback for every 1' of height over 4'; absolute max 12' high; not in sight triangle.
Wall SignNot listedUp to 10% of building face to which sign is attachedNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for TrussvilleFull Coverage

Sign Types Covered

73

  • Wall Sign
  • Monument Sign
  • Message Board/Reader Board (Accessory)
  • Projecting Sign
  • +2 more types

Zoning Districts

35

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Trussville

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Trussville, the height limit for Monument Sign in the C-2 General Business District (C-2) is 6 ft at 15' setback; up to 12 ft with additional setback. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Trussville require a permit. From the submission notes on this page: Master signage plans are reviewed and approved by the Planning and Zoning Board; they may be submitted with or after site development/parking/drainage/landscape plans. Approval is required before any sign covered by the plan is permitted (Sec. 25.0(C)–(E)). Run a code check for an exact address to see the permit requirements for that zone.

Trussville's sign code covers 73 sign types, including Wall Sign, Monument Sign, Message Board/Reader Board (Accessory), and Projecting Sign. Most commercial signs need a permit. The ordinance lists 9 exemptions. One of them: On private property, detached noncommercial signs not exceeding 2 square feet in area and less than 4 feet in height, and noncommercial wall signs not exceeding 2 square feet, are allowed in all zoning districts without a permit (Sec. 6.0(A)(2)–(3); Sec. 7.0(A)–(C)). The full list is on this page.

In Trussville, Monument Sign in the C-2 General Business District (C-2) must be set back at least 15' from pavement. The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Trussville's sign ordinance that cover digital, changing, or flashing signs: Changes of copy on an existing, permitted manual or electronic message board/reader board are allowed without a new permit, provided the sign structure and area remain the same (Sec. 7.0(E); Sec. 2.0 definitions of changeable copy signs). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Trussville Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Trussville, Alabama, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Trussville, Alabama Sign Rules at a Glance

Trussville, Alabama regulates 73 sign types across 35 zoning districts. Directory/Menu/On-Site Informational Freestanding Signs in the C-2 General Business District (C-2) are capped at 6 ft tall and 16 sq ft. Most commercial signs in Trussville require a permit.

Detailed Sign Ordinance Requirements for Trussville, Alabama

Sign Rules by Zoning District in Trussville (35 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones1Not listedNot listedNot listed
A-1 Agricultural District (A-1)44 ft at 15' setback; may increase up to 12 ft with 3 ft additional setback for each 1 ft over 4 ft32 sq ftNot listed
CP Preferred Commercial District (C-P, CP)86 ftPer approved master signage plan (may receive up to 150% size incentive on base allowance)Not listed
C-1 Local Shopping District (C-1)8Up to 25–45 ft depending on center type (per master plan incentives)Up to incentives: e.g., 150% of base monument size; shopping center freestanding allocations (400–1,500 sq ft total for large centers)Not listed
C-2 General Business District (C-2)1060–80 ft normally; up to 120 ft with special justificationUp to 300 sq ft or 25% of facade facing street, whichever is less, in addition to base allowancesNot listed
C-3 Tourist Commercial District (C-3)1060–80 ft standard; up to 120 ft with special approvalUp to 300 sq ft or 25% of facade facing street (whichever less), in addition to baseNot listed
C-4 Commercial/Light Manufacturing District (C-4)9Up to 25–45 ftUp to 300 sq ft or 25% of facade facing streetNot listed
C-5 Commercial Adult Entertainment District (C-5)56 ft≤30% of sign faceNot listed
I-1 Light Industrial District (I-1)8≤25 ftUp to 400 sq ft total freestanding monolith signage; each sign ≤300 sq ftNot listed
I-2 General Industrial District (I-2)8≤25 ftUp to 400 sq ft total freestanding monolith signage; each sign ≤300 sq ftNot listed
I-3 Industrial District (I-3)8≤25 ftUp to 400 sq ft total freestanding monolith signage; each sign ≤300 sq ftNot listed
IN-1 Institutional District (IN-1)56 ft at 15' setback; up to 12 ft60 sq ftNot listed
IN-2 Institutional District (IN-2)66 ft at 15' setback; up to 12 ft60 sq ftNot listed
IN-3 Institutional District (IN-3)46 ft at 15' setback; up to 12 ft60 sq ftNot listed
P Park District (P)4Not listed100 sq ft per principal building or recreational facility (freestanding monument)Not listed
PUD Planned Unit Development District (PUD, PUD-PC, PR-1, PR-2, PR-3, PO, PC, PCS, PB, P-MX, PCOS)1Not listedNot listedNot listed
"Q" Qualified Zone District (Q, "Q" C-2)1Not listedNot listedNot listed
Residential Districts (R-1, R-2, R-3, R-4, R-5, R-6, R-CP, R-G, R-T, R-MP, MP)7Not listed48 sq ftNot listed
R-1 Single-Family Residential District (R-1)3Not listedFreestanding 48 sq ft; wall 4 sq ft per entranceNot listed
R-2 Single-Family Residential District (R-2)3Not listedFreestanding 48 sq ft; wall 4 sq ft/entranceNot listed
R-3 Single-Family Residential District (R-3)3Not listedFreestanding 48 sq ft; wall 4 sq ft/entranceNot listed
R-4 Single-Family/Duplex Residential District (R-4)3Not listedFreestanding 48 sq ft; wall 4 sq ft/entranceNot listed
R-5 Multi-Family Residential District (R-5)3Not listedFreestanding 48 sq ft; wall 4 sq ft/entranceNot listed
R-6 Single-Family District (R-6)3Not listedFreestanding 48 sq ft; wall 4 sq ft/entranceNot listed
R-CP Residential, Cahaba Project Mixed Residential District (R-CP)3Not listedFreestanding 48 sq ft; wall 4 sq ft per entranceNot listed
RG Garden Home Residential District (R-G)3Not listed6 sq ftNot listed
RT Townhouse Residential District (R-T)3Not listed6 sq ftNot listed
MP Mobile Home Park District (R-MP, MP)3Not listed6 sq ftNot listed
CEM-1 Cemetery (CEM-1)1Not listedNot listedNot listed
CEM-2 Pet Cemetery (CEM-2)1Not listedNot listedNot listed
Start free to see 5 more zones

Zone-by-Zone Sign Requirements in Trussville(sample of 3 of 35 zones)

C-2 General Business District (C-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Monument Sign6 ft at 15' setback; up to 12 ft with additional setback60 sq ftNot listed≥15' from pavement; add 3' per 1' over 6'; max 12' high.1 per principal building.On-premises, serving principal building.Not listedUnlockSec. 11.0(A), Art. XI.
Wall SignNot listed≤25% of building face; max 150 sq ft per face (except large establishment bonus below)Not listedNot listedNot numerically capped; area limits apply.On building wall.Not listedUnlockSec. 11.0(B), Art. XI.
Projecting SignNot listed16 sq ftNot listedNot listedMax 1 per building side.On wall of building served.Not listedUnlockSec. 11.0(C); Sec. 3.0(T), Art. XI.
Directory/Menu/On-Site Informational Freestanding Sign6 ft16 sq ftNot listedNot listedOne or more.On premises; not legible from ROW/adjacent property.Not listedUnlockSec. 11.0(I), Art. XI.
Entrance Wall-Mounted Informational SignNot listed12 sq ftNot listedNot listed1 per public entrance.Near each public entrance.Not listedUnlockSec. 11.0(J), Art. XI.
Shopping Center/Office Complex Entrance Sign (Master Sign Plan)Up to 25–45 ft depending on center sizeAs per Sec. 25.0 incentives (e.g., up to 400–1,500 sq ft total freestanding signage by center size)Not listedPer monument standards or as in plan.Per plan and Sec. 25.0 category limits.At entrances, on-premises.Not listedUnlockSec. 11.0(E); Sec. 25.0(G)(3)–(5), Art. XI.
Interstate High-Rise Sign60–80 ft normally; up to 120 ft with special justificationStandard up to 250 sq ft; up to 350 sq ft if special height increase grantedNot listedCannot be forward of front building setback line along any non-interstate street; specific distance not otherwise stated.1 interstate high-rise sign per qualifying property; no other pole/pylon signs allowed.On-premises within Interstate High-Rise Sign Zone; must be behind front building setback line of all streets except interstate right-of-way; positioned for visibility from interstate.Not listedUnlockSec. 11.0(G); Sec. 3.0(Q), Art. XI.
Temporary and Portable SignsNot listed≤24 sq ftNot listedFreestanding: ≥15' from pavement; not in ROW or sight triangle.Max 1 portable/temporary per establishment at a time.On-premises; freestanding at least 15' from pavement; or wall-mounted.Not listedUnlockSec. 11.0(H); Sec. 24.0, Art. XI.

C-3 Tourist Commercial District (C-3)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Monument Sign6 ft at 2' setback (note: text likely intended 15', but states 2'); may increase up to 12 ft with added setback60 sq ftNot listedAt least 15' from pavement (by general rule) and not in sight triangle; plus 3' extra setback for each 1' of height over 6'; max 12' high.1 per principal building.On-premises.Not listedUnlockSec. 12.0(A); Sec. 3.0(G), Art. XI.
Wall SignNot listed≤25% of building face; max 150 sq ftNot listedNot listedNot numerically capped; area limits per face.On building wall.Not listedUnlockSec. 12.0(B), Art. XI.
Projecting SignNot listed16 sq ftNot listedNot listedMax 1 per building side.On wall of building served.Not listedUnlockSec. 12.0(C); Sec. 3.0(T), Art. XI.
Directory/Menu/On-Site Informational Freestanding Sign6 ft16 sq ftNot listedNot listedOne or more.On-site, not legible from public ROW or adjacent property.Not listedUnlockSec. 12.0(H), Art. XI.
Entrance Wall-Mounted Informational SignNot listed12 sq ftNot listedNot listed1 per public entrance.Near each public entrance.Not listedUnlockSec. 12.0(I), Art. XI.
Shopping Center/Office Complex Entrance Sign (Master Plan)Up to 25–45 ft per center sizePer Sec. 25.0(G) incentivesNot listedAs in plan; generally like monument signs.Per plan and size category limits.At entrances.Not listedUnlockSec. 12.0(E); Sec. 25.0(G), Art. XI.
Interstate High-Rise Sign60–80 ft standard; up to 120 ft with special approval250 sq ft (standard) or up to 350 sq ft with special approvalNot listedNot forward of front building setback line along non-interstate streets.1 per qualifying property.On-premises within Interstate High-Rise Sign Zone; behind front building setback line of non-interstate streets.Not listedUnlockSec. 12.0(G); Sec. 3.0(Q), Art. XI.
Temporary and Portable SignsNot listed≤24 sq ftNot listedFreestanding: ≥15' from pavement; not in sight triangle/ROW.1 portable/temporary per establishment at a time.On premises; freestanding ≥15' from pavement; or wall-mounted.Not listedUnlockSec. 12.0(H); Sec. 24.0, Art. XI.

C-4 Commercial/Light Manufacturing District (C-4)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Monument Sign6 ft at 15' setback; up to 12 ft with added setback60 sq ftNot listed≥15' from pavement; add 3' per 1' height over 6'; max 12' height.1 per principal building.On-premises.Not listedUnlockSec. 13.0(A), Art. XI.
Wall SignNot listed≤25% of building face; max 150 sq ftNot listedNot listedNot numerically capped; area limited.On building wall.Not listedUnlockSec. 13.0(B), Art. XI.
Projecting SignNot listed16 sq ftNot listedNot listedMax 1 per building side.On wall of building it serves.Not listedUnlockSec. 13.0(C); Sec. 3.0(T), Art. XI.
Directory/Menu/On-Site Informational Freestanding Sign6 ft16 sq ftNot listedNot listedOne or more.On site; not legible from ROW/adjacent property.Not listedUnlockSec. 13.0(H), Art. XI.
Entrance Wall-Mounted Informational SignNot listed12 sq ftNot listedNot listed1 per public entrance.Near each public entrance.Not listedUnlockSec. 13.0(I), Art. XI.
Message Board/Reader Board (Accessory)Not listed≤30% of sign faceNot listedNot listedPer host sign.Within monument or wall sign.Not listedUnlockSec. 13.0(D); Sec. 3.0(E), Art. XI.
Shopping Center/Office Complex Entrance Sign (Master Plan)Up to 25–45 ftPer Sec. 25.0(G) incentivesNot listedAs per monument rules or plan.Per plan.At entrances.Not listedUnlockSec. 13.0(E); Sec. 25.0(G), Art. XI.
Temporary and Portable SignsNot listed≤24 sq ftNot listedFreestanding: ≥15' from pavement; not in ROW/sight triangle.1 per establishment at a time.On premises; freestanding ≥15' from pavement; may be wall-mounted.Not listedUnlockSec. 13.0(G); Sec. 24.0, Art. XI.

PermitPal covers all 35 zoning districts in Trussville. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Trussville

  • No sign shall be erected or maintained where, by reason of its position, wording, illumination, shape, symbol, color, form, or character, it may obstruct, impair, obscure, interfere with the view of, or be confused with any authorized traffic sign, signal, or device, or interfere with, mislead, confuse, or disrupt traffic safety or flow (Sec. 3.0(A)).
  • No portion of a sign may obscure visibility between a height of three and ten feet within a sight triangle, unless specifically approved due to unique conditions (Sec. 3.0(B)).
  • Signs incorporating noisy mechanical devices such as whistles, horns, sirens, or any other noisy audible devices are prohibited (Sec. 3.0(C)).
  • No sign or its foundation/support shall be placed in a public street or highway right‑of‑way, except certain neighborhood signs as separately provided (Sec. 3.0(D)).
  • No sign may have animated, blinking, flashing, intermittent, traveling, or fluctuating lights, or LCD, plasma, video, or similar displays, including arrangements that spell messages, simulate motion, or form various symbols or images, except signs whose message changes no more than once per minute (Sec. 3.0(E)).
  • No sign may use rotating vertical or horizontal panels or other moving parts to change the message (Sec. 3.0(F)).
  • Signs shall not interfere with traffic visibility for entrance/exit from the lot or adjacent lots or for traffic flow through nearby intersections; monument signs must generally be at least 15 feet from pavement edge (Sec. 3.0(G)).
  • No illuminated sign, other than a permanent neighborhood identification sign or an institutional sign, is permitted within 100 feet of any residential zoning district (Sec. 3.0(H)).
  • All signs must be maintained in a safe and proper operating manner; the area around signs must be kept clean and free of trash and litter (Sec. 3.0(I); Sec. 29.0).
  • Each sign must contain a complete message or display (Sec. 3.0(J); Sec. 29.0(5)).
  • Temporary signs must have the installation date noted on the sign (Sec. 3.0(K); Sec. 24.0(J)).
  • Signs shall not be attached to trees, utility poles, rocks, street lights, or to fences except where expressly allowed (Sec. 3.0(L)).
  • No signs may be placed on public property except as specifically authorized in the sign regulations (Sec. 3.0(M)).
  • All signs must conform to applicable building code provisions, including structural, wind, seismic, and electrical standards (Sec. 3.0(N)).
  • No person may damage, trim, destroy, or remove trees, shrubs, or other vegetation within any right‑of‑way or required landscaping area for the purpose of increasing or enhancing the visibility of any sign, unless expressly authorized by the agency having jurisdiction (Sec. 3.0(O)).
  • No new billboards are permitted anywhere in the city (Sec. 3.0(P); Sec. 23.0(A); repeated as a prohibition in multiple zone‑specific sections).
  • Any sign over 80 feet in height must be constructed to allow for the future addition of telecommunications arrays or antennae (Sec. 3.0(Q)).
  • Window and door signage counts toward sign area limits, and may not occupy more than 25 percent of the total window and door area (Sec. 3.0(R)–(S)).
  • Projecting signs are limited to one per building side (per elevation) and do not count toward the maximum number of wall/window signs or sign square footage, but are otherwise constrained by the projecting‑sign standards (Sec. 3.0(T)).
  • Exposed neon is prohibited as a building design element and may not flash or change color; for signs, exposed neon is only allowed under the limitations in Sec. 4.0(A) (Sec. 4.0(A)).
  • Certain materials are prohibited for sign backgrounds, frames, supports, and ornamentation, including exposed metal poles (unless masonry‑clad), smooth‑face concrete blocks, and metal or plastic panels used without brick, split‑face block, or stone (Sec. 4.0(B)(4)).
  • Portable signs are prohibited in specific districts (CP, I‑1, I‑2, I‑3) and temporary signs are prohibited in shopping center areas (Sec. 9.0(F), 15.0(F), 16.0(G), 17.0(F), 24.0(C)).
  • Signs that are abandoned (e.g., business closed, blank/irrelevant message, event concluded) must be removed; continued display after 90 days constitutes a violation (Sec. 28.0–29.0).
  • Nonconforming signs may not be structurally altered to extend their useful life, and may not be replaced with other nonconforming signs when replacement is required due to deterioration (Sec. 30.0(C)(2)–(3)).

Exempt Signs in Trussville

  • Traffic control and other official signs erected by governmental entities or utilities (including MUTCD‑compliant traffic signs, DOT/ALDOT directional signs, tourist‑oriented directional signs, and public information signs) are exempt from permit requirements, though they must comply with other standards where feasible (Sec. 5.0(A)–(B)).
  • Signs installed by state or federal agencies in the course of governmental duties, or required by state or federal statute or court order, may exceed size or other standards to the extent required by the statute or order; otherwise they must conform to the ordinance (Sec. 5.0(B)(2)–(4)).
  • On private property, detached noncommercial signs not exceeding 2 square feet in area and less than 4 feet in height, and noncommercial wall signs not exceeding 2 square feet, are allowed in all zoning districts without a permit (Sec. 6.0(A)(2)–(3); Sec. 7.0(A)–(C)).
  • In single‑family residential districts only, permanent noncommercial signs up to 5 square feet are allowed without a permit (Sec. 7.0(B)).
  • Any permitted sign not legible from a public way or from private property other than the lot on which the sign is located is allowed without a permit (Sec. 7.0(C)).
  • Routine maintenance of signs (cleaning, touch‑up painting, like‑for‑like bulb replacement, poster panel changes on billboards, and similar work that does not change the structure, size, shape, or identification) does not require a sign permit (Sec. 2.0, definition of sign maintenance/repair; Sec. 7.0(D), (E); Sec. 27.0(E)).
  • Changes of copy on an existing, permitted manual or electronic message board/reader board are allowed without a new permit, provided the sign structure and area remain the same (Sec. 7.0(E); Sec. 2.0 definitions of changeable copy signs).
  • Certain very small, noncommercial temporary signs in agricultural, residential, or institutional districts not exceeding 6 square feet are allowed without a permit (Sec. 7.0(A); Sec. 22.0(B); Sec. 8.0(C); Sec. 18.0(E)–20.0(F)).
  • Signs located inside athletic fields in park districts, generally legible only from seating areas and not exceeding 4 by 8 feet, are exempt from permit requirements (Sec. 21.0(D)).

Sign Plan & Submission Notes for Trussville

  • A master signage plan is optional but may be submitted by owners of qualifying properties (shopping centers, office complexes, industrial parks, large institutional campuses, recreational complexes) in business, commercial, industrial, park, and institutional districts to coordinate all signs on a site (Sec. 25.0(A)–(B)).
  • Master signage plans are reviewed and approved by the Planning and Zoning Board; they may be submitted with or after site development/parking/drainage/landscape plans. Approval is required before any sign covered by the plan is permitted (Sec. 25.0(C)–(E)).
  • Applications for a master signage plan must include: plot plan, sign design drawings, building/parking/driveway/landscape layout, computations of total allowed sign area and height, allocation of sign area among tenants, locations of all present/future signs, sign design schemes (colors, materials, typeface), and owner/agent signatures (Sec. 25.0(D)).
  • Once a master signage plan is approved, all signs on the covered premises must comply with that plan; no sign may be erected or maintained in conflict with it. The plan is enforceable like any other zoning regulation (Sec. 25.0(J)).
  • An approved master signage plan can be amended only by submitting a new plan that meets all current standards; amendments follow the same review process (Sec. 25.0(E)).
  • Master signage plans for existing developments must include a schedule to bring all existing nonconforming signs into conformance by a specified date; this schedule becomes a binding condition of approval (Sec. 25.0(F)).
  • Master signage plans allow specific incentives, including: (a) treating all property in the plan as one premises for off‑premises determinations; (b) increased monument sign size for single tenants over 50,000 sq ft; (c) increased monument sign size for multi‑tenant retail/office buildings; (d) additional wall signage for large/set‑back shopping centers; and (e) larger and/or more numerous freestanding signs for neighborhood, community, regional, and super‑regional shopping centers, industrial parks, and large institutional campuses, within stated square footage and height caps (Sec. 25.0(G)).
  • Approval criteria for a master signage plan include: compliance with all applicable sign standards (subject to allowed incentives), correct total sign area and number, proportional allocation among tenants based on frontage/entrances/facade area, and a unified design scheme for all wall and freestanding signs (materials, colors, shape, proportion, typeface, lighting) (Sec. 25.0(H)–(I)).
  • Several zone‑specific sections explicitly require or reference master signage plans as a precondition for certain freestanding or entrance signs, including CP, C‑1, C‑2, C‑3, C‑4, I‑1, I‑2, I‑3, IN‑1, IN‑2, IN‑3, and P districts (e.g., office complexes, shopping centers, industrial parks, recreation complexes) (Secs. 9.0(E), 10.0(E), 11.0(E), 12.0(E), 13.0(E), 15.0(E), 16.0(F), 17.0(E), 18.0(E), 19.0(E), 20.0(E), 21.0(A)–(B)).
  • The Downtown Overlay district allows or references master signage plans for shopping centers and office complexes within the district; such plans must still meet the Downtown‑specific sign standards and external illumination requirement (Sec. 14A.0(E); Sec. 19B.9(A)).
  • Site‑level plans are generally required for new development in commercial, industrial, institutional, and certain overlay districts (site, drainage, parking, landscape, lighting, and buffer plans), and master signage plans may be coordinated with these submissions (Sec. 2.0(C); Sec. 9.0(B); Sec. 13.0(B); Sec. 19A.12; Sec. 19B.9(A)).

Source: municode municipal code