Sign Regulations in Glendora, California

Glendora, California has specific sign regulations covering 30 sign types across 11 zoning districts. Regulated sign types include Wall Sign, Temporary Sign, Awning Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 10, 2025

Sign Regulation Overview for Glendora, California

Sample Sign Requirements in Glendora

Sign TypeMax HeightMax AreaSetback
Detached Sign5 feet6 square feet—
Nameplate—2 square feet—
Directional Real Estate Sign12 feet32 square feetMinimum of 10 feet from any property line, and a minimum of 50 feet from any residence not in the tract

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for GlendoraFull Coverage

Sign Types Covered

30

  • Wall Sign
  • Temporary Sign
  • Awning Sign
  • Nameplate
  • +2 more types

Zoning Districts

11

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Glendora

Frequently Asked Questions

Sign height limits in Glendora vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Glendora, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Glendora, regulated sign types include Wall Sign, Temporary Sign, Awning Sign, Nameplate, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Glendora vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Glendora are regulated with specific requirements for brightness, animation, and message duration. Glendora has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Glendora Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Glendora, California — with citations from the municipal code.

No credit card required · Get results in seconds

Glendora, California Sign Rules at a Glance

Glendora, California regulates 30 sign types across 11 zoning districts. Freestanding Sign - Shared Uses in the Other commercial zones zoning district are capped at 10 feet tall and 24 square feet per face, with a Not located within thirty-five feet of any other freestanding sign on the same side of the primary street setback (Sec. § 19.24.070(9)(D)). Most commercial signs in Glendora require a permit.

Detailed Sign Ordinance Requirements for Glendora, California

Sign Rules by Zoning District in Glendora (11 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Single-family residential zones412 feet32 square feet—
Multiple-family residential zones46 feet50 square feet per face—
C-1 zones410 feet24 square feet—
Other commercial zones1330 feet240 square feet—
CCAP zone (T-5, Village Core)612 feet25% of any window area—
CCAP zone (T-5A, Village Transition)612 feet25% of any window area—
CCAP zone (T-4, Village Edge)46 feet50 square feet per face—
Limited industrial, R-4 and light manufacturing zones (M-1, R-4, M-1A)4—100 square feet—
Route 66 Corridor specific plan project area (BG, GCG, RSC, CRR, LHG, TCO)710 feet100 square feet per sign face—
Route 66 Corridor specific plan project area (TCMU, GLG)710 feet100 square feet per sign face—
General Regulations For All Zones2—64 square feet—

Zone-by-Zone Sign Requirements in Glendora(sample of 3 of 11 zones)

Other commercial zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign—40 square feet——OneAttached to the front wall of the building—Unlock§ 19.24.070(1)
Wall Sign - Intersection—40 square feet——One per sideAttached to the wall of each side of the building facing the public street—Unlock§ 19.24.070(3)
Temporary Sign—40 square feet——OneAttached to the main building—Unlock§ 19.24.070(6)
Banner—45 square feet——One per business locationAttached to the face of the building—Unlock§ 19.24.070(8)
Freestanding Sign - Shopping Center30 feet240 square feet——OneShopping center occupying ten or more commercial acres with a single street frontage—Unlock§ 19.24.070(9)(A)(i)a
Freestanding Sign - Service Station15 feet35 square feet per face——One double-facedService stations—Unlock§ 19.24.070(9)(B)
Freestanding Sign - Single Commercial Establishment30 feet240 square feet——OneNon-shopping center, non-service station single commercial establishments having a minimum street frontage of two hundred feet—Unlock§ 19.24.070(9)(C)(i)a
Freestanding Sign - Shared Use10 feet24 square feet per face—Not located within thirty-five feet of any other freestanding sign on the same side of the primary streetOneNon-shopping center, non-service station, single commercial establishments having a street frontage of less than two hundred feet—Unlock§ 19.24.070(9)(D)

Route 66 Corridor specific plan project area (BG, GCG, RSC, CRR, LHG, TCO)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Monument Sign6 feet40 square feet per face—Minimum of seventy-five feet between monument signsOnePer property frontage—Unlock§ 21.10.390A
Primary Identification Sign10 feet100 square feet per sign face—Minimum streetside setback of ten feetOneNear the primary street entrance to the center—Unlock§ 21.10.390B
Secondary Monument Sign5 feet50 square feet per sign face—Minimum streetside setback of ten feetOne per street frontageAlong each street frontage, except for the street on which the primary identification sign is located—Unlock§ 21.10.390B
Awning Sign————One per structure frontageOn structure frontages, including those fronting a parking lot or pedestrian way—Unlock§ 21.10.390D
Projecting Sign—20 square feet per sign face——One per wall frontageOn the wall frontage with the primary ground floor entrance to the structure—Unlock§ 21.10.390E
Wall Sign————One per wall frontageOn walls having frontage along streets, alleys, parking lots, or on-site parking lots—Unlock§ 21.10.390F
Window Sign—25% of the window area——One per windowOn the ground floor level and second story of a structure frontage—Unlock§ 21.10.390G

Route 66 Corridor specific plan project area (TCMU, GLG)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Monument Sign6 feet40 square feet per face—Minimum of seventy-five feet between monument signsOnePer property frontage—Unlock§ 21.10.390A
Primary Identification Sign10 feet100 square feet per sign face—Minimum streetside setback of ten feetOneNear the primary street entrance to the center—Unlock§ 21.10.390B
Secondary Monument Sign5 feet50 square feet per sign face—Minimum streetside setback of ten feetOne per street frontageAlong each street frontage, except for the street on which the primary identification sign is located—Unlock§ 21.10.390B
Awning Sign————One per structure frontageOn structure frontages, including those fronting a parking lot or pedestrian way—Unlock§ 21.10.390D
Projecting Sign—20 square feet per sign face——One per wall frontageOn the wall frontage with the primary ground floor entrance to the structure—Unlock§ 21.10.390E
Wall Sign————One per wall frontageOn walls having frontage along streets, alleys, parking lots, or on-site parking lots—Unlock§ 21.10.390F
Window Sign—25% of the window area——One per windowOn the ground floor level and second story of a structure frontage—Unlock§ 21.10.390G

PermitPal covers all 11 zoning districts in Glendora. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements — illumination rules, size formulas, and permit requirements for every sign type — with a free account.

Run a code check for your exact address — free

Prohibited Signs in Glendora

  • All signs are prohibited on private property except as expressly permitted by this chapter, or by the requirements of law or federal or state regulations.
  • All signs are prohibited on public property except as expressly permitted by this chapter, or by the requirements of law or federal or state regulations.
  • Signs painted directly on buildings pertaining to other than the identification of the building or business contained therein are prohibited.
  • No sign, nor any part thereof, shall be constructed or maintained to flash, move, or in any way simulate motion, except those signs which thereby advise the viewing public of time, temperature, or both.
  • Portable signs are prohibited.
  • All billboards are prohibited.
  • Mobile billboard advertising is unlawful.

Exempt Signs in Glendora

  • Interior signs are exempt from construction material requirements.
  • Mobile billboard advertising exemptions include vehicles displaying an advertisement or business identification of its owner engaged in the usual business or regular work of the owner, buses, and taxicabs.

Sign Plan & Submission Notes for Glendora

  • Buildings with more than one tenant space shall provide a sign program for review and approval by the planning department or the reviewing body for the project as part of any zoning review process for the property.
  • Site plan approval and a building permit are required for temporary real estate development signs located on unimproved premises.

Source: municode municipal code