Questions? Call us at (262) 218-2915

Sign Regulations in Garden Grove, California

Garden Grove, California has specific sign regulations covering 26 sign types across 10 zoning districts. Regulated sign types include Nameplate, Sales/Lease/Rental Sign, Rental/Lease Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 10, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Garden Grove, California

Sample Sign Requirements in Garden Grove

Sign TypeMax HeightMax AreaSetback
Directional SignNot listed6 sq. ft.Not listed
Political SignNot listed32 sq. ft.Not listed
Window DisplayNot listed15% of total window areaNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Garden GroveFull Coverage

Sign Types Covered

26

  • Nameplate
  • Sales/Lease/Rental Sign
  • Rental/Lease Sign
  • Group A Sign
  • +2 more types

Zoning Districts

10

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Garden Grove

Frequently Asked Questions

In Garden Grove, the height limit for Monument Sign in the R-2, R-3 zoning districts is 5 ft. or 6 ft (Sec. 9.20.060C). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Garden Grove require a permit. From the submission notes on this page: Sign programs for existing developments shall be submitted for discretionary review and approval to the Zoning Administrator. Run a code check for an exact address to see the permit requirements for that zone.

Garden Grove's sign code covers 26 sign types, including Nameplate, Sales/Lease/Rental Sign, Rental/Lease Sign, and Group A Sign. Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Official notices of any court or public office and legal notices posted pursuant to law or ordinance. The full list is on this page.

This page doesn't list a single setback distance for signs in Garden Grove. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.

Rules in Garden Grove's sign ordinance that cover digital, changing, or flashing signs: No person shall erect or maintain any device that directs a beam of light in a flashing sequence toward any street or highway. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Garden Grove Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Garden Grove, California, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Garden Grove, California Sign Rules at a Glance

Garden Grove, California regulates 26 sign types across 10 zoning districts. Development Directional Signs are capped at 10 ft tall and 64 sq ft per face (Sec. 9.20.040G.1-3). Most commercial signs in Garden Grove require a permit.

Detailed Sign Ordinance Requirements for Garden Grove, California

Sign Rules by Zoning District in Garden Grove (10 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones1035 ft.1,000 cubic feetNot listed
R-12Not listed6 sq. ft.Not listed
R-2, R-335 ft. or 6 ft.20 sq. ft. display surface, not greater than 5 feet in height; 32 sq. ft. display surface, not greater than 6 feet in height, for the uses listed in Section 9.20.050.J only.Not listed
O-P4Not listed40 sq. ft. per 10,000 sq. ft. of building area, not to exceed 200 sq. ft.Not listed
C-1, C-2, C-33Not listed20 sq. ft. aggregate displayNot listed
M-12Not listed20 sq. ft. aggregate displayNot listed
M-P2Not listed20 sq. ft. aggregate displayNot listed
O-S1Not listedNot listedNot listed
International West Resort Area350 ft.Not listedNot listed
Garden Grove (22) Freeway Corridor160 ft.680 sq. ft. per faceNot listed

Zone-by-Zone Sign Requirements in Garden Grove(sample of 3 of 10 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Directional SignNot listed6 sq. ft.Not listedNot listedNot listedPrivate propertyNot listedUnlock§ 9.20.030C.1-2
Political SignNot listed32 sq. ft.Not listedNot listed1 per candidate or issuePrivate propertyNot listedUnlock§ 9.20.040B.1-5
Window DisplayNot listed15% of total window areaNot listedNot listedNot listedWindowNot listedUnlock§ 9.20.040D.1-3
Public Service SignNot listed6 sq. ft.Not listedNot listed2 per facilityPublic right-of-way of major or primary highwayNot listedUnlock§ 9.20.040E.1-5
Development Directional Sign10 ft.64 sq. ft. per faceNot listedNot listed2 per projectLand development projectNot listedUnlock§ 9.20.040G.1-3
Temporary Real Estate SignNot listed50 sq. ft. per faceNot listedNot listed2 per tractAny tract recorded within approved tentative tract mapNot listedUnlock§ 9.20.040H
Temporary Construction SignNot listed50 sq. ft. per faceNot listedNot listed2 per siteConstruction siteNot listedUnlock§ 9.20.040I
Temporary Advertising Balloon35 ft.1,000 cubic feetNot listedNot in landscaped areas, parking space or required setback area1 per eventAffixed to immobile structureNot listedUnlock§ 9.20.040J.1-3

R-2, R-3

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
NameplateNot listed2 sq. ft.Not listedNot listed1 per unitResidential unitNot listedUnlock§ 9.20.060C
Sales/Lease SignNot listed0-4 units: 12 sq. ft.; 5-15 units: 16 sq. ft.; 16+ units: 20 sq. ft.Not listedNot listed1 per propertyResidential propertyNot listedUnlock§ 9.20.060C
Monument Sign5 ft. or 6 ft.20 sq. ft. display surface, not greater than 5 feet in height; 32 sq. ft. display surface, not greater than 6 feet in height, for the uses listed in Section 9.20.050.J only.Not listedNot listed1 per propertyResidential propertyNot listedUnlock§ 9.20.060C

O-P

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
NameplateNot listed1 sq. ft. per businessNot listedNot listed1 per businessBusiness propertyNot listedUnlock§ 9.20.060C
Directory SignNot listed1 sq. ft. per businessNot listedNot listed1 per businessBusiness propertyNot listedUnlock§ 9.20.060C
Sales/Lease/Rental SignNot listed20 sq. ft. aggregate displayNot listedNot listed2 per propertyBusiness propertyNot listedUnlock§ 9.20.060C
Wall SignNot listed40 sq. ft. per 10,000 sq. ft. of building area, not to exceed 200 sq. ft.Not listedNot listedNot listedBusiness propertyNot listedUnlock§ 9.20.060C

PermitPal covers all 10 zoning districts in Garden Grove. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Garden Grove

  • No sign shall be so located or constructed so as to interfere with or hinder vehicular movement or be placed over any vehicular access way in a manner that would reduce the vertical ground clearance to less than 14 feet.
  • No sign may be designed, lighted, placed or displayed that would in any way simulate any type of traffic control device, emergency vehicle or any emergency warning device.
  • No sign shall be erected, constructed, or maintained within an area designated by an approved street specific plan for a public right-of-way.
  • Exposed light bulbs that may be seen from a public street or property line shall not be used in conjunction with any advertising display, except that neon lights or similar types of fluorescent lighting specifically designed to be used as a sign face materials may be used.
  • No person shall erect or maintain any device that directs a beam of light in a flashing sequence toward any street or highway.
  • Rotating or revolving signs, except for temporary advertising, are prohibited.
  • Painted commercial and industrial wall signs in any location are prohibited.
  • Roof signs are prohibited.
  • Vehicle signs are prohibited.
  • Portable and A-frame signs are prohibited.
  • Bare bulb illumination is expressly prohibited.
  • Reader boards are specifically prohibited on monument or pylon signs.

Exempt Signs in Garden Grove

  • Interior signs not defined as window signs and that are not intended to be viewed outside the structure.
  • Official notices of any court or public office and legal notices posted pursuant to law or ordinance.
  • Traffic signs or other signs erected or maintained by a government body or agency, including, but not limited to, danger signs, railroad crossing signs, geographic signs, and historical signs.
  • Public utility company signs erected or maintained as aids to safety or service or indicating danger.
  • Flags of nations, states, counties, or cities; political groups; religious organizations; charitable or fraternal organizations or societies.
  • Positions available signs provided they carry no information other than company identification and positions available, display area does not exceed 15 square feet, must be constructed as a window or wall-type sign, and only one sign per street frontage is permitted.
  • Signs on benches or shelters authorized pursuant to Chapter 11.36 of this code and in compliance with Business and Professions Code Section 5408.5.

Sign Plan & Submission Notes for Garden Grove

  • A sign program shall be required for all existing commercial and industrial developments in the City that contain two or more uses where individual signs are allocated or have been placed for those individual uses and that currently do not have an approved and adopted sign program.
  • Sign programs for existing developments shall be submitted for discretionary review and approval to the Zoning Administrator.
  • No permit shall be issued after six months from the above scheduled sign program time frame for an individual sign requiring a permit, unless and until a sign program for all the existing commercial and industrial developments on which the sign will be erected has been submitted and approved by the Zoning Administrator.

Source: municode municipal code