Sign Regulations in Dacono, Colorado
Dacono, Colorado has specific sign regulations covering 12 sign types across 6 zoning districts. Regulated sign types include Sign (Any), Temporary Sign (General, Not Exceeding 10 sq ft), Temporary Sign (Commercial, Paper/Canvas/Cloth). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Sign Regulation Overview for Dacono, Colorado
Sample Sign Requirements in Dacono
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Temporary Sign (General, Not Exceeding 10 sq ft) | — | 10 sq ft total per property, 5 sq ft per face | — |
| Temporary Sign (Commercial, Paper/Canvas/Cloth) | — | 50 sq ft total per property | — |
| Temporary Tract Sign (Residential) | 12 ft | 100 sq ft | Placement per Sec. 16-303 |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
12
- Sign (Any)
- Temporary Sign (General, Not Exceeding 10 sq ft)
- Temporary Sign (Commercial, Paper/Canvas/Cloth)
- Temporary Tract Sign (Residential)
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Dacono
Other Cities in Colorado
Frequently Asked Questions
Sign height limits in Dacono vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.
To get a sign permit in Dacono, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Dacono, regulated sign types include Sign (Any), Temporary Sign (General, Not Exceeding 10 sq ft), Temporary Sign (Commercial, Paper/Canvas/Cloth), Temporary Tract Sign (Residential), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Dacono vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Dacono are regulated with specific requirements for brightness, animation, and message duration. Dacono has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Dacono Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Dacono, Colorado sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Dacono, Colorado Sign Rules at a Glance
Dacono, Colorado regulates 12 sign types across 6 zoning districts. Identification Sign (Permitted use - Residential or Nonresidential)s in the R-1, R-2, MH, MR, RR-1, DR, A zoning district are capped at 8 ft tall, 5 sq ft, and 4 ft (max dimension in any one direction) wide, with a Not closer than 10 ft to property line, sidewalk/curb, or traveled edge of street, whichever is greater (Sec. 16-303(a)) setback (Sec. Sec. 16-304(a); Sec. 16-299(c); Sec. 16-302(b)). Most commercial signs in Dacono require a permit.
Detailed Sign Ordinance Requirements for Dacono, Colorado
Sign Rules by Zoning District in Dacono (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 8 | 20 ft (flagpole) | 100 sq ft | — |
| R-1, R-2, MH, MR, RR-1, DR, A | 2 | 8 ft | 10 sq ft | — |
| CR | 1 | 10 ft | Based on building frontage (see formula) | — |
| C-1, I-1 | 1 | 10 ft | Based on lot frontage (see formula) | — |
| commercial or industrial zone | 1 | 12 ft | 100 sq ft | — |
| Planned Unit Development (PUD) | 1 | — | — | — |
Zone-by-Zone Sign Requirements in Dacono(sample of 3 of 6 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Temporary Sign (General, Not Exceeding 10 sq ft) | — | 10 sq ft total per property, 5 sq ft per face | 4 ft (maximum dimension in any one direction for permitted uses in R/A zones) | — | — | On the property being advertised/identified | — | Unlock | Sec. 16-297(a)(1) |
| Temporary Sign (Commercial, Paper/Canvas/Cloth) | — | 50 sq ft total per property | — | — | — | Commercial or industrial zoned property | — | Unlock | Sec. 16-297(a)(2) |
| Temporary Tract Sign (Residential) | 12 ft | 100 sq ft | — | Placement per Sec. 16-303 | See sign size restrictions | Site of subdivision or development, at major entrance | — | Unlock | Sec. 16-297(b)(1) |
| Temporary Tract Sign (Nonresidential, Commercial or Industrial Zone) | 12 ft | 100 sq ft | — | Placement per Sec. 16-303 | 1 per subdivided lot | On site (each lot in commercial or industrial zone district) | — | Unlock | Sec. 16-297(b)(2) |
| Temporary Model Home Sign (Builder, Group) | 6 ft | 40 sq ft | — | Placement per Sec. 16-303 | 1 per group per builder | On the model home lot | — | Unlock | Sec. 16-297(b)(3)a |
| Temporary Model Home Sign (Each Model Home) | 6 ft | 5 sq ft | — | Placement per Sec. 16-303 | 1 per model home | On the same lot as model home | — | Unlock | Sec. 16-297(b)(3)b |
| Temporary Model Home Sign (Multi-family Building Entrance) | 6 ft | 5 sq ft | — | Placement per Sec. 16-303 | 1 per building entrance | On the lot of the multi-family building | — | Unlock | Sec. 16-297(b)(3)c |
| Temporary Model Home Flag | 20 ft (flagpole) | 15 sq ft per flag; 90 sq ft total area for all flags | — | Placement per Sec. 16-303 | — | Within 200 ft of subdivision entrance on model home lot containing model or temp sales office | — | Unlock | Sec. 16-297(b)(3)d |
R-1, R-2, MH, MR, RR-1, DR, A
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Identification Sign (Permitted use - Residential or Nonresidential) | 8 ft | 5 sq ft | 4 ft (max dimension in any one direction) | Not closer than 10 ft to property line, sidewalk/curb, or traveled edge of street, whichever is greater (Sec. 16-303(a)) | 1 per property | On property identifying the use | — | Unlock | Sec. 16-304(a); Sec. 16-299(c); Sec. 16-302(b) |
| Identification Sign (Public/Semi-public building or use) | 8 ft | 10 sq ft | 4 ft (max dimension in any one direction) | Not closer than 10 ft to property line, sidewalk/curb, or traveled edge of street, whichever is greater (Sec. 16-303(a)) | 1 per property | On property identifying the public/semi-public use | — | Unlock | Sec. 16-304(b); Sec. 16-299(c); Sec. 16-302(b) |
commercial or industrial zone
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Temporary Tract Sign (Nonresidential) | 12 ft | 100 sq ft | — | Placement per Sec. 16-303 | 1 per lot | On site | — | Unlock | Sec. 16-297(b)(2) |
PermitPal covers all 6 zoning districts in Dacono — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 6 zones for Dacono — start freeProhibited Signs in Dacono
- It is unlawful to erect or maintain any sign regulated by this Article without first obtaining a permit from the Building Official, unless specifically exempted.
- Animated or flashing signs are prohibited.
- Signs that move with the wind are prohibited.
- Signs that have been installed or erected to project into or over a public right-of-way are prohibited.
- Signs not permanently affixed or attached to the ground or to any structure are prohibited, except for temporary signs or signs carried by a person.
- Signs placed on a roof are prohibited.
- Off premise signs are prohibited unless otherwise authorized. Signs may only be erected, altered, and maintained on the same lot as the permitted use(s) they advertise or identify.
- Abandoned signs are prohibited. (A sign is considered abandoned if it advertises a business, lessor, owner, product, service or activity that is no longer located on the premises.)
- Any sign that could be mistaken for or confused with a traffic control sign, signal or device is prohibited.
- Mirrored or reflective signs are prohibited. No mirror device shall be used as part of a sign.
- Audible signs are prohibited.
- The lighting of any sign must be shielded to prevent light shining directly onto adjoining properties or rights-of-way.
- The direct or reflected light from any sign must not create a traffic hazard or distraction to operators of motor vehicles.
- Sign lighting is not allowed to flash, flutter, or turn on and off for periods of time less than a sixty-second interval.
- Temporary signs shall not be illuminated.
Exempt Signs in Dacono
- Temporary signs as identified within Subsection 16-297(a) are exempt from permit requirements.
- Home occupation signs permitted under Article 21 of this Chapter are exempt from permit requirements.
- Official governmental traffic control devices, official governmental informational signs, street identification signs, and other governmental signs placed for public safety needs are exempt from permit requirements and placement restrictions.
- Temporary signs as described in Sec. 16-297(a) (including general temporary signs up to 10 square feet and certain commercial temporary signs up to 50 square feet for up to 90 days per year) are exempt from all provisions of this Article except as otherwise specifically provided.
Sign Plan & Submission Notes for Dacono
- A sign permit is required for all signs unless specifically exempted by the ordinance.
- Sign Permit applications must be filed with the Building Official and must include specified information and property owner consent if the applicant is not the owner.
- A variance may be sought and must be approved by the City for the continued maintenance and use of nonconforming signs.
- Signage within an approved Planned Unit Development (PUD) may vary from these provisions if so established in the approved PUD Final Development Plan.
- A permit is required for certain temporary signs as specified in Sec. 16-297(b).
Source: municode municipal code