Superior, Colorado has specific sign regulations covering 17 sign types across 6 zoning districts. Regulated sign types include Instructional Sign, Temporary Sign, Window Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Superior, Colorado

Sample Sign Requirements in Superior

Sign TypeMax HeightMax AreaSetback
Instructional Sign3 ft.6 sq. ft.
Temporary Sign3 ft.4 sq. ft.3 ft.
Temporary Subdivision Sign8 ft.32 sq. ft. per sign face, max 2 faces; 15 ft. width10 ft. from nearest public right-of-way.

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for SuperiorFull Coverage

Sign Types Covered

17

  • Instructional Sign
  • Temporary Sign
  • Window Sign
  • Freestanding Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Superior

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

Sign height limits in Superior vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Superior, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Superior, regulated sign types include Instructional Sign, Temporary Sign, Window Sign, Freestanding Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Superior vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Superior are regulated with specific requirements for brightness, animation, and message duration. Superior has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Superior Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Superior, Colorado sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Detailed Sign Ordinance Requirements for Superior, Colorado

Sign Rules by Zoning District in Superior (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential lots48 ft.32 sq. ft. per sign face, max 2 faces; 15 ft. width
Nonresidential property915 ft.50 sq. ft.
Residential zone district1
Community Business (B-C), Regional Business (B-R), Light Industry (I-L), Heavy Industry (I-H)315 ft.100 sq. ft.
Planned Development (PD)1
General Regulations For All Zones33.5 ft. (>50 ft from intersection), 2.5 ft. (<=50 ft from intersection)4 sq. ft.

Zone-by-Zone Sign Requirements in Superior(sample of 3 of 6 zones)

Residential lots

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Instructional Sign3 ft.6 sq. ft.Minimum necessary to serve intended purposeOn residential lot, not to be legible or draw attention beyond perimeter.UnlockSec. 16-19-60(b); Table.
Temporary Sign3 ft.4 sq. ft.3 ft.1 per lot (plus election season and large lot exceptions)On residential lot, at least 3 ft. from public right-of-way.UnlockSec. 16-19-60(c); Table.
Temporary Subdivision Sign8 ft.32 sq. ft. per sign face, max 2 faces; 15 ft. width15 ft.10 ft. from nearest public right-of-way.SFD/2FD/TH: 1 per entrance, max 2; MFD: 1 per 50 unitsAt entrances from arterial/collector roads (SFD/2FD/TH) or at any entrance (MFD).UnlockSec. 16-19-60(d); Table.
Window Sign3 ft.4 sq. ft.1 per building (SFD); 1 per unit (MFD)In window; 1 per building (SFD), 1 per unit (MFD)UnlockSec. 16-19-60(e); Table.

Nonresidential property

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Building Sign - Wall Sign15 ft.15% of wall areaSame as building setback.1 per building, or 1 per street entranceOn walls, awnings, canopies, or parapets.UnlockSec. 16-19-70(a); Table.
Building Sign - Protruding Sign15 ft.8 sq. ft. per faceSee wall sign rulesOn building w/min 10 ft. of street frontage.UnlockSec. 16-19-70(a)(2)c
Freestanding Sign10 ft.Per face: 0.3 sq ft/ft frontage, up to 100 sq ftSame as building setback.1 per building, or 1 per entrance (multi-business at intersection)As allowed by zone and building setback; for multi-business, per entrance at major intersections.UnlockSec. 16-19-70(c); Table.
Instructional Sign6 sq. ft.Minimum necessary for purposeOn nonresidential property; may be placed on freestanding sign base (not counted in area)UnlockSec. 16-19-70(e); Table.
Temporary Sign8 ft.32 sq. ft. (other than window sign)1 per property (+ election seasonal signs)On property (not specified); window temporary signs on windowsUnlockSec. 16-19-70(f); Table.
Banner50 sq. ft.Up to 4 permits/yrAttached to building, not freestandingUnlockSec. 16-19-70(g); Table.
Window Sign8 ft. (top of sign)33% of window area, max 50 sq. ft.No more than 50% of window width1 per windowDisplay windows of business use.UnlockSec. 16-19-70(h); Table.
Pan Channel Sign5 inches deep; 12 inches total depth if mounted on racewayOn wallUnlockSec. 16-19-70(b)

Community Business (B-C), Regional Business (B-R), Light Industry (I-L), Heavy Industry (I-H)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign15 ft.15% of wall areaBuilding setback1 per entranceOn wall, awning, canopy, parapetUnlockSec. 16-19-70(a), 16-19-100(c)
Freestanding Sign10 ft.100 sq. ft.Building setback1 per building/entranceSetback by building setbackUnlockSec. 16-19-70(c), 16-19-100(c)-(d)
Other Signs (Instructional, Temporary, Banner, Window, Protruding, Pan Channel, Changeable Copy)UnlockSec. 16-19-70, 16-19-100(c)

PermitPal covers all 6 zoning districts in Superior — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Superior — start free

Prohibited Signs in Superior

  • Any sign not expressly allowed by this Article or not in conformance with its requirements is prohibited.
  • Billboards are prohibited.
  • Signs incorporating any flashing or moving illumination or with illumination that periodically varies in intensity or color are prohibited.
  • Signs which have any visible moving part, visible revolving parts or visible mechanical movement or other apparent visible movement achieved by electrical pulsations, by actions or normal wind currents (including promotional balloons and inflatable devices) are prohibited.
  • Signs with light sources not shielded by opaque material such that bulbs, floodlights, or tubes are visible off the property are prohibited.
  • Any sign that violates any provision of this Article or constitutes a hazard to public safety, health, or welfare is prohibited.
  • Signs that obstruct the vision of drivers traveling on, leaving, or entering a roadway are prohibited.
  • Any sign that obstructs free ingress to or egress from a fire escape, door, window, or other required exit is prohibited.
  • Abandoned signs are prohibited.
  • Searchlights, pennants, and spinners are prohibited.
  • Roof signs or any signs which project above a building wall or parapet are prohibited.
  • Pole-mounted signs are prohibited.
  • Portable signs are prohibited, except as expressly permitted in Section 16-19-40.
  • Signs with exposed cables or electrical raceway mountings are prohibited, unless the Manager finds that unusual construction problems exist.
  • Permanent freestanding signs on residential lots are prohibited.
  • Permanent signs in the public right-of-way are prohibited unless allowed by a revocable license agreement with the Town and conforming to this Article.
  • Illuminated signs are prohibited on residential lots.
  • No sign within 150 feet of a residential zone district shall be illuminated between 10:00 p.m. and 7:00 a.m.
  • Lighting directed toward a sign must be shielded so it illuminates only the face of the sign and does not shine directly into a public right-of-way or residential lot.
  • Internally illuminated signs are only allowed in specific business and industrial districts.
  • Internally illuminated freestanding signs shall not be illuminated when the business is closed, except as specified.
  • Illuminated tubing or strings of lights outlining property lines, sales areas, roof lines, doors, windows or similar areas are prohibited except during a national holiday.
  • Signs shall not contain or be illuminated by flashing or intermittent lights or lights of changing degrees of intensity, except signs indicating time, date, or weather conditions.
  • Neon signs shall not exceed 4 square feet.
  • No person may damage, trim, destroy, or remove any trees, shrubs, or other vegetation to increase/enhance sign visibility without written authorization.

Exempt Signs in Superior

  • Signs not exceeding three (3) square feet in area customarily associated with residential uses (property identification names/numbers, signs on mailboxes/newspaper tubes, warning signs about trespassing or animals).
  • Signs required or specifically authorized for a public purpose by any law, statute, or ordinance, regardless of type, number, area, height, location, illumination, or animation.
  • Official signs erected by state or local governments, contractors, or public utilities to facilitate construction, maintenance, or operation of transportation facilities or to warn of danger/hazardous conditions.
  • Memorial signs or tablets, names of buildings, dates of erection cut into masonry or inlaid, or constructed of bronze/incombustible material, not exceeding 15 square feet.
  • Flags of any nation or government or displaying a noncommercial message, not exceeding 40 square feet and not extending over public right-of-way.
  • Architectural features of buildings or works of art without letters, trademarks, moving parts, lights, or a commercial message.
  • Traffic control signs such as 'STOP' or 'YIELD' on public or private property that meet applicable standards and do not display a commercial message.
  • Name plate signs of not more than four (4) square feet fastened directly to a building and not projecting from the face of the building.
  • Holiday and community special event decorations that do not display a commercial message.
  • Signs on athletic fields and scoreboards intended for viewing on the property where the scoreboard is located.
  • Signs located inside buildings not intended to be visible/read from the outside and not legible from a distance of more than three (3) feet beyond the building.
  • Instructional signs on Town property erected by the Town.

Sign Plan & Submission Notes for Superior

  • Any sign not expressly allowed or not in conformance with the requirements of this Article is prohibited.
  • Upon submittal of a final development plan for a Planned Development (PD), the applicant may seek approval of its own sign plan for the PD or meet the requirements of this Article.
  • All permanent building signs, permanent freestanding signs, and any illuminated sign (including retrofits) require a sign permit except as specifically provided in the Article.
  • A plan showing design, materials, colors, lighting, construction, and attachment method is required with a sign permit application.
  • Traffic control signs require submission of plans for type, location, and size, subject to Town Manager approval.
  • For multiple-occupant nonresidential properties/facilities, the property owner determines sign area allocation; consistency of design and placement is required for all signs within a development.
  • All signs within a single development must display consistency of design and placement.

Source: municode municipal code