Sign Regulations in New Britain, Connecticut
New Britain, Connecticut has specific sign regulations covering 4 sign types across 5 zoning districts. Regulated sign types include Wall Sign, Freestanding (Detached or Ground) Identification Sign, Roof Sign. Height restrictions apply. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 8, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for New Britain, Connecticut
Sample Sign Requirements in New Britain
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign | Not listed | 2 sq. ft. per linear foot of building wall | Not listed |
| Freestanding (Detached or Ground) Identification Sign | 15 ft | 32 sq. ft. per side (otherwise see formula) | 20 ft from property lines; may use average setback if block average is <10 ft. |
| Roof Sign | 15 ft above roof | Not listed | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
4
- Wall Sign
- Freestanding (Detached or Ground) Identification Sign
- Roof Sign
- Freestanding Ground Sign
Zoning Districts
5
Different zoning districts with specific sign regulations
Data Includes
- Height restrictions
Official Resources for New Britain
Other Cities in Connecticut
Frequently Asked Questions
In New Britain, the height limit for Freestanding (Detached or Ground) Identification Sign in the I-2 zoning district is 21 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
We haven't published New Britain's application steps on this page yet. Run a code check for an exact address to see the permit requirements for that zone.
New Britain's sign code covers 4 sign types, including Wall Sign, Freestanding (Detached or Ground) Identification Sign, Roof Sign, and Freestanding Ground Sign.
In New Britain, Freestanding (Detached or Ground) Identification Sign in the B-1, B-2, OP, I-1 zoning districts must be set back 20 ft from property lines. The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
We haven't published New Britain's rules for digital or LED signs on this page yet. Run a code check for an exact address to see them.
Ready to Research New Britain Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in New Britain, Connecticut, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
New Britain, Connecticut Sign Rules at a Glance
New Britain, Connecticut regulates 4 sign types across 5 zoning districts. Roof Signs in the I-2 zoning district are capped at 15 ft above roof.
Detailed Sign Ordinance Requirements for New Britain, Connecticut
Sign Rules by Zoning District in New Britain (5 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| B-1, B-2, OP, I-1 | 3 | 15 ft | 32 sq. ft. per side (otherwise see formula) | Not listed |
| B-1R | 3 | 15 ft | 32 sq. ft. per side (otherwise see formula) | Not listed |
| I-2 | 3 | 21 ft | 32 sq. ft. per side (otherwise see formula) | Not listed |
| All other industrial zones | 3 | 25 ft above roof | 32 sq. ft. per side (otherwise see formula) | Not listed |
| UI Zoning District | 1 | 5 ft | 32 sq. ft. | Not listed |
Zone-by-Zone Sign Requirements in New Britain(sample of 3 of 5 zones)
B-1, B-2, OP, I-1
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 2 sq. ft. per linear foot of building wall | 75% of wall length (or 90% if wall is 20 ft or less) | Not listed | Not listed | Attached to or incorporated into the building wall. | Not listed | Unlock | 250-30-10.10, 250-30-10.20, 250-30-10.30, [Approved 2-23-06, Item #28899-2] 250-30-30.20, 250-30-30.30, 250-30-30.40. |
| Freestanding (Detached or Ground) Identification Sign | 15 ft | 32 sq. ft. per side (otherwise see formula) | 25 ft unbroken width | 20 ft from property lines; may use average setback if block average is <10 ft. | Not listed | Ground or detached sign | Not listed | Unlock | 250-30-20.10, 250-30-20.20, 250-30-20.30, 250-30-20.50 [Approved 2-23-06, Item #28899-2] |
| Roof Sign | 15 ft above roof | Not listed | 75% of wall length | Not listed | Not listed | Mounted on the roof of the building or structure | Not listed | Unlock | 250-30-30.10, 250-30-30.20, 250-30-30.30, 250-30-30.40 |
B-1R
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 1 sq. ft. per linear foot of building wall | 75% of wall length (or 90% if wall is 20 ft or less) | Not listed | Not listed | Attached to or incorporated into the building wall. | Not listed | Unlock | 250-30-10.10, 250-30-10.20, 250-30-10.30 [Approved 2-23-06, Item #28899-2] |
| Freestanding (Detached or Ground) Identification Sign | 15 ft | 32 sq. ft. per side (otherwise see formula) | 25 ft unbroken width | 20 ft from property lines; may use average setback if block average is <10 ft. | Not listed | Ground or detached sign | Not listed | Unlock | 250-30-20.10, 250-30-20.20, 250-30-20.30, 250-30-20.50 [Approved 2-23-06, Item #28899-2] |
| Roof Sign | 15 ft above roof | Not listed | 75% of wall length | Not listed | Not listed | Mounted on the roof of the building or structure | Not listed | Unlock | 250-30-30.10, 250-30-30.20, 250-30-30.30, 250-30-30.40 |
I-2
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 3 sq. ft. per linear foot of building wall | 75% of wall length (or 90% if wall is 20 ft or less) | Not listed | Not listed | Attached to or incorporated into the building wall. | Not listed | Unlock | 250-30-10.10, 250-30-10.20, 250-30-10.30 |
| Freestanding (Detached or Ground) Identification Sign | 21 ft | 32 sq. ft. per side (otherwise see formula) | 25 ft unbroken width | 20 ft from property lines; may use average setback if block average is <10 ft. | Not listed | Ground or detached sign | Not listed | Unlock | 250-30-20.10, 250-30-20.20, 250-30-20.30, 250-30-20.50 |
| Roof Sign | 15 ft above roof | Not listed | 75% of wall length | Not listed | Not listed | Mounted on the roof of the building or structure | Not listed | Unlock | 250-30-30.10, 250-30-30.20, 250-30-30.30, 250-30-30.40 |
PermitPal covers all 5 zoning districts in New Britain. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in New Britain
- Signs shall not be located so as to interfere with sightlines for any public or private street or driveway.
- The supporting members of a roof sign shall be free of any bracing angle iron, guy wires, cables, etc. The supports shall appear to be an architectural and integral part of the building.
Source: municode municipal code