Sign Regulations in Bunnell, Florida
Bunnell, Florida has specific sign regulations covering 18 sign types across 3 zoning districts. Regulated sign types include All Permanent Sign Types, Signs in the Public Right-of-Way (Permanent: Governmental, Transit, Public Utility, Emergency Warning), Signs in the Public Right-of-Way (Temporary, Non-Commercial Message). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Sign Regulation Overview for Bunnell, Florida
Sample Sign Requirements in Bunnell
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Signs in the Public Right-of-Way (Temporary, Non-Commercial Message) | — | 2 sq ft | — |
| Flagpole and Flags | Flagpole: 25 ft | Flags: 4.5 ft x 6 ft or less; up to 6 flags per parcel; 1 flagpole | Minimum 5 ft from property line |
| Residential Development Identification Signs | 2.5 ft (if within clear visibility triangle) | Combined max 240 sq ft for all; individual sign max 120 sq ft | 5 ft minimum |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
18
- All Permanent Sign Types
- Signs in the Public Right-of-Way (Permanent: Governmental, Transit, Public Utility, Emergency Warning)
- Signs in the Public Right-of-Way (Temporary, Non-Commercial Message)
- Flagpole and Flags
- +2 more types
Zoning Districts
3
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Bunnell
Other Cities in Florida
Frequently Asked Questions
Sign height limits in Bunnell vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.
To get a sign permit in Bunnell, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Bunnell, regulated sign types include All Permanent Sign Types, Signs in the Public Right-of-Way (Permanent: Governmental, Transit, Public Utility, Emergency Warning), Signs in the Public Right-of-Way (Temporary, Non-Commercial Message), Flagpole and Flags, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Bunnell vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Bunnell are regulated with specific requirements for brightness, animation, and message duration. Bunnell has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Bunnell Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Bunnell, Florida sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Bunnell, Florida Sign Rules at a Glance
Bunnell, Florida regulates 18 sign types across 3 zoning districts. Flagpole and Flags in the Residential areas zoning district are capped at Flagpole: 25 ft tall and Flags: 4.5 ft x 6 ft or less; up to 6 flags per parcel; 1 flagpole, with a Minimum 5 ft from property line setback (Sec. Sec. 26-133(1)). Most commercial signs in Bunnell require a permit.
Detailed Sign Ordinance Requirements for Bunnell, Florida
Sign Rules by Zoning District in Bunnell (3 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 3 | — | 2 sq ft | — |
| Residential areas | 7 | Flagpole: 25 ft | Combined max 240 sq ft for all; individual sign max 120 sq ft | — |
| Nonresidential areas | 8 | 30 ft | Varies by setback: 32 sq ft (0 ft setback/3 ft H); 96 sq ft (10 ft set./8+ ft H); 128 sq ft (15 ft set./8+ ft H); 160 sq ft (20 ft set./8+ ft H); 200 sq ft (25 ft set./8+ ft H); >32 sq ft requires min 5 ft setback. | — |
Zone-by-Zone Sign Requirements in Bunnell
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| All Permanent Sign Types | — | — | — | — | — | — | — | Unlock | Sec. 26-131 |
| Signs in the Public Right-of-Way (Permanent: Governmental, Transit, Public Utility, Emergency Warning) | — | — | — | — | — | Public right-of-way | — | Unlock | Sec. 26-132(a)(1), (a)(3), (b) |
| Signs in the Public Right-of-Way (Temporary, Non-Commercial Message) | — | 2 sq ft | — | — | — | Public right-of-way | — | Unlock | Sec. 26-132(a)(2) |
Residential areas
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Flagpole and Flags | Flagpole: 25 ft | Flags: 4.5 ft x 6 ft or less; up to 6 flags per parcel; 1 flagpole | — | Minimum 5 ft from property line | 1 flagpole, 6 flags per parcel | Ground-mounted flagpole | — | Unlock | Sec. 26-133(1) |
| Residential Development Identification Signs | 2.5 ft (if within clear visibility triangle) | Combined max 240 sq ft for all; individual sign max 120 sq ft | — | 5 ft minimum | Up to 3 per development | At up to 3 principal entrances to subdivision or multifamily development | — | Unlock | Sec. 26-133(2) |
| Model Home Center Identification Signs | — | 32 sq ft per sign | — | 5 ft minimum | 1 per model home | Same lot as model home, in a model home center (2+ model homes on a block) | — | Unlock | Sec. 26-133(3)a |
| Model Home Identification Signs (Single Home) | — | 16 sq ft | — | 10 ft minimum | 1 per model home | Same lot as model home (single home, not in model home center) | — | Unlock | Sec. 26-133(3)b |
| Model Home Center Additional Identification Signs | — | Total 16 sq ft for up to 2 additional signs | — | — | Up to 2 | Model home center lot | — | Unlock | Sec. 26-133(3)c.1 |
| Model Home Center Flags (Single-Pole) | — | Flag: 12 sq ft maximum each | — | — | Up to 4 per street frontage | Per street frontage | — | Unlock | Sec. 26-133(3)c.2 |
| Wall Sign (Churches, Clubs, and Special Exception Uses) | — | 4 sq ft | — | — | 1 per special exception use | — | — | Unlock | Sec. 26-133(4) |
Nonresidential areas
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign | Varies: 3 ft at 0 ft setback; 6 ft at 5 ft; 8+ ft at 10 ft+; Max sign height 35 ft, except wood (24 ft) | Varies by setback: 32 sq ft (0 ft setback/3 ft H); 96 sq ft (10 ft set./8+ ft H); 128 sq ft (15 ft set./8+ ft H); 160 sq ft (20 ft set./8+ ft H); 200 sq ft (25 ft set./8+ ft H); >32 sq ft requires min 5 ft setback. | — | See table: 0 ft (32 sq ft/3 ft H); 5 ft (>32 sq ft/6-8+ ft H); 10 ft (96 sq ft/8+ ft H); 15 ft (128 sq ft/8+ ft H); 20 ft (160 sq ft/8+ ft H); 25 ft (200 sq ft/8+ ft H) | 1 per parcel, plus 1 per additional arterial road access | On-site, minimum 100 ft from other freestanding sign/natural barrier/river. Not within site minimum buffer. | — | Unlock | Sec. 26-134(a)(1)-(6) |
| Wall Sign | May not extend >3 ft above roof/wall intersection nor above parapet. | — | — | — | 1 per business (choose wall/projecting/marquee sign) | Shall not project >2 ft beyond face of building. Not above parapet or top edge. | — | Unlock | Sec. 26-134(a)(8) |
| Projecting Sign | Bottom at least 8 ft above grade | — | — | — | 1 per business (choose wall/projecting/marquee sign) | Shall not project >2 ft beyond face of building. | — | Unlock | Sec. 26-134(a)(8) |
| Marquee Sign | No higher than vertical marquee face or beyond marquee itself; bottom at least 8 ft above sidewalk/grade; can project below lower edge of marquee up to 12" | — | — | — | 1 per business (choose wall/projecting/marquee sign) | On vertical faces of marquees/awnings, as permitted | — | Unlock | Sec. 26-134(a)(9) |
| Directional Sign | — | 2 sq ft | — | Can be up to property line | — | Up to property line | — | Unlock | Sec. 26-134(a)(4) |
| Drive-Through Menu Board (Freestanding Menu Sign) | — | — | — | — | Up to 2 per drive-through | Adjacent to and oriented toward drive-through area of restaurant | — | Unlock | Sec. 26-134(a)(10) |
| Off-Site Subdivision Identification Sign | — | — | — | — | 1 per parcel | On vacant parcel at least 50 ft wide | — | Unlock | Sec. 26-134(b) |
| Flagpole and Flags (Nonresidential) | 30 ft | 2 flags per parcel (4 if government-owned) | — | 5 ft minimum | 1 flagpole/2 flags per parcel; government: 2 flagpoles/4 flags | Ground-mounted flagpoles | — | Unlock | Sec. 26-134(c) |
Illumination rules, size formulas, and permit requirements for every sign type in Bunnell are available with a free PermitPal account.
Start freeProhibited Signs in Bunnell
- No signs shall be allowed in the public right-of-way, except as specifically exempted.
- Any sign installed or placed on public property, except in conformance with the requirements of the ordinance, shall be forfeited to the public and subject to confiscation.
- The city may recover the full costs of removal and disposal from the owner or person placing a sign illegally on public property.
- All signs (except for banners, flags, temporary signs, and window signs conforming with the ordinance) must be constructed of permanent materials and be permanently attached to the ground, a building, or another structure.
- Banners, streamers, or similar devices are expressly prohibited in areas of residential development.
Exempt Signs in Bunnell
- Public signs erected by or on behalf of a governmental body to post legal notices, identify public property, convey public information, and direct or regulate pedestrian or vehicular traffic are allowed in the public right-of-way.
- Bus stop signs erected by a public transit company are allowed in the public right-of-way.
- Informational signs of a public utility regarding its poles, lines, pipes, or facilities are allowed in the public right-of-way.
- Temporary signs for which a permit has been issued, containing no commercial message and no more than two square feet in area each, are allowed in the public right-of-way.
- Emergency warning signs erected by a governmental agency, a public utility company, or a contractor doing authorized or permitted work are allowed in the public right-of-way.
Sign Plan & Submission Notes for Bunnell
- Maintenance requirements for residential development identification signs must include the establishment of an owner's association or appropriate provisions for continuing maintenance after the developer leaves.
- If maintenance responsibilities for residential development signs are not provided, the developer must remove the signs after the sale of the last lot or dwelling unit, and this requirement shall be assured by the posting of a bond by the developer.
Source: municode municipal code