Sign Regulations in Greenacres, Florida

Greenacres, Florida has specific sign regulations covering 28 sign types across 11 zoning districts. Regulated sign types include Freestanding Sign, Wall Sign, Address Sign (Residential). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Greenacres, Florida

Sample Sign Requirements in Greenacres

Sign TypeMax HeightMax AreaSetback
Address Sign (Residential)6 inchesNot listedNot listed
Address Sign (Non-Residential)12 inches (unless approved by master sign plan)Not listedNot listed
Official Notice SignNot listed2 sq ft (unless specified by government rule)Not listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for GreenacresFull Coverage

Sign Types Covered

28

  • Freestanding Sign
  • Wall Sign
  • Address Sign (Residential)
  • Address Sign (Non-Residential)
  • +2 more types

Zoning Districts

11

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Greenacres

City Website1 permit application link available

Frequently Asked Questions

In Greenacres, the height limit for Freestanding Banner Sign is 18 in (Sec. 16-969(a)). Maximum sign heights range from 6 ft to 18 in across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Greenacres require a permit. From the submission notes on this page: Existing developments: If a sign owner desires to replace, alter, relocate a sign, or perform repair/maintenance not in compliance with these regulations, a master sign plan must be prepared and submitted. Run a code check for an exact address to see the permit requirements for that zone.

Greenacres's sign code covers 28 sign types, including Freestanding Sign, Wall Sign, Address Sign (Residential), and Address Sign (Non-Residential). Most commercial signs need a permit. The ordinance lists 10 exemptions. One of them: Mandatory address signs do not require a permit. The full list is on this page.

In Greenacres, Freestanding Temporary Commercial Sign must be set back 5 ft from property line (Sec. 16-969(e)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Greenacres's sign ordinance that cover digital, changing, or flashing signs: Animated signs. Exposed neon tubing, neon signs, and LED signs that emulate the general appearance of traditional neon signs. Electronic changeable copy signs, except for certain types specifically permitted elsewhere (e.g., time and temperature signs, gas station price signs, certain government or menu board signs). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Greenacres Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Greenacres, Florida, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Greenacres, Florida Sign Rules at a Glance

Greenacres, Florida regulates 28 sign types across 11 zoning districts. Freestanding Banner Signs are capped at 18 in tall, 15 sq ft, and 10 ft wide, set back 5 ft from property line (Sec. 16-969(a)). Most commercial signs in Greenacres require a permit.

Detailed Sign Ordinance Requirements for Greenacres, Florida

Sign Rules by Zoning District in Greenacres (11 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones1518 in32 sq ftNot listed
Residential districts2Not listed32 sq ft per sign faceNot listed
Planned residential developments, Subdivisions1Not listed32 sq ft per sign faceNot listed
Non-residential districts, Commercial districts28 ftNot listedNot listed
Multi-tenant commercial properties28 ftNot listedNot listed
Outparcels and outbuildings within a unified development18 ft40 sq ft per sign faceNot listed
CG, CI, GU58 ftCG: 240 sq ft; CI, GU: 400 sq ftNot listed
OPI, MXD-O28 ftOPI: 60 sq ft; MXD-O: 90 sq ftNot listed
CN, MXD-OS38 ft75 sq ftNot listed
MXD-R, MXD-C28 ft30 sq ftNot listed
AR, RE, RL, RM, RH, GU16 ft5 sq ftNot listed

Zone-by-Zone Sign Requirements in Greenacres(sample of 3 of 11 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary Sign (General, Noncommercial, year-round)Not listed3 sq ft (residential); 4 sq ft (non-residential)Not listed5 feet from right-of-way/side lines unless greater for visibility triangle1On private property, set back as required.Not listedUnlockSec. 16-967, 16-968(a)
Temporary Election Sign (Residential district, before election)Not listed3 sq ft (unless on major arterial, then 16 sq ft)Not listed5 feet from right-of-way/side lines unless greater for visibility triangleOne per candidate/issuePrivate property or designated public property areas during voting.Not listedUnlockSec. 16-968(b)
Temporary Real Estate Sign (Residential district)Not listed3 sq ftNot listed5 feet from right-of-way/side lines unless greater for visibility triangle1On property offered for sale/lease.Not listedUnlockSec. 16-968(c)
Construction Sign (Residential district)8 ft16 sq ftNot listed10 ft from all property lines1 per street frontageOne per development street frontageNot listedUnlockSec. 16-969(d)
Construction Sign (Non-residential district)8 ft32 sq ftNot listed10 ft from all property lines1 per street frontageOne per development street frontageNot listedUnlockSec. 16-969(d)
Freestanding Temporary Commercial SignNot listed3 sq ft (residential); 4 sq ft (other districts)Not listed5 ft from property line1Secured in ground, 5 ft from property line. Not in walkway, landscaping, or vehicular area.Not listedUnlockSec. 16-969(e)
Freestanding Banner Sign18 in15 sq ft10 ft5 ft from property line1 per commercial buildingSecured in ground, at least 5 ft from property lineNot listedUnlockSec. 16-969(a)
Directory Sign (General)6 ft16 sq ft (all other districts); 12 sq ft (mixed use); 32 sq ft (planned commercial developments)Not listed20 ft (front); 10 ft (side-corner)1 per major vehicular accessOne per major vehicular access; as wall sign or freestanding.Not listedUnlockSec. 16-990

CG, CI, GU

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign8 ftCG: 240 sq ft; CI, GU: 400 sq ftNot listed10 ft from property line1 per frontageMonument, at major access point; as permitted by general provisions.Not listedUnlockSec. 16-983(b), (d), (8)
Wall SignNot listed240 sq ft (per sign face)Not listedNot listed1 per frontage (additional per multi-tenant rules)On wall façade, min 12 in side, 6 in top/bottom, not above top of structure.Not listedUnlockSec. 16-983(b),(c),(7)
Electronic Gas Station Price Sign (Integral to Freestanding, Option 1)Not listed12 sq ftNot listedNot listedIncluded in freestanding signAs part of freestanding sign (gas station only)Not listedUnlockSec. 16-983(b)(5)
Canopy Identification Sign (Gas Station)Not listed8 sq ft (per sign)Not listedNot listed1 per frontageOn fuel canopyNot listedUnlockSec. 16-983(b)(5)
Menu Board Sign (Drive-thru Lane)6 ft38 sq ft, plus possible 6 sq ft for LCDNot listedNot listed1 per drive-thru laneDrive-thru laneNot listedUnlockSec. 16-994

CN, MXD-OS

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign8 ft75 sq ftNot listed10 ft from property line1 per frontageMonument, at major access pointNot listedUnlockSec. 16-983(b),(8)
Wall SignNot listed75 sq ftNot listedNot listed1 per frontage (multi-tenant: 1 per tenant space)On buildingNot listedUnlockSec. 16-983(b),(7)
Under Canopy SignNot listed6 sq ftNot listedNot listed1 per tenantUnder canopy, as part of master sign plan.Not listedUnlockSec. 16-993

PermitPal covers all 11 zoning districts in Greenacres. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Greenacres

  • Any signs or advertising structures which are not specifically permitted under this chapter or signs that exceed the sign allowance for the district.
  • Any sign or advertising structure which constitutes a traffic hazard or a detriment to traffic safety by reason of its size, location, movement, content, coloring, or method of illumination, or by obstructing the vision of drivers, or signs that obstruct or detract from the visibility of traffic-control devices or emergency vehicles.
  • The use of flashing lights or revolving lights is prohibited as part of any sign.
  • Any sign which by glare or method of illumination constitutes a hazard to either vehicular or non-vehicular traffic.
  • Any sign which may be confused with or purports to be a governmental, traffic direction or safety sign, or any other sign or group of signs which create a traffic hazard as determined by the city.
  • Any sign or advertising structure with words, scenes or graphics which are obscene, indecent and prurient or which exhibit obscene or illegal written messages or materials.
  • Any sign or advertising structure (other than those constructed by a governmental agency or required to be constructed by a governmental agency for a public purpose) constructed, installed or placed on the right-of-way of any street, road or public way, or signs overhanging or infringing upon the right-of-way of any street, road or public way, except as specifically permitted by this chapter.
  • Any sign or advertising structure constructed on city property or other governmental property other than signs constructed by any governmental entity for public purposes, except as specifically authorized by this chapter.
  • Any sign or advertising structure which is constructed, installed or maintained that obstructs any fire escape, required exit, window or door opening intended as a means of ingress or egress.
  • Any sign or advertising structure which is constructed, installed or maintained upon the rear of a building, with the exception of signs to identify the business address on a rear exit door with no greater than six (6) inch non-illuminated letters with a minimum stroke width of one-half inch (½") located directly above the rear door, or as required by fire safety regulations.
  • "A" frame signs.
  • Animated signs.
  • Banner signs, with the exception of those banner signs that are granted a temporary use permit by the city.
  • Banner flag signs.
  • Off-premises signs.
  • Portable signs.
  • Projecting signs.
  • Snipe signs.
  • Temporary signs, except as allowed under division 4 of this article.
  • Vehicular signs.
  • Vee-shaped signs.
  • Abandoned signs.
  • Signs placed upon benches, bus shelters, or waste receptacles, except as may be authorized by the City of Greenacres or as superseded by state statutes.
  • Under canopy signs, except as allowed as a part of an approved Master Sign Plan.
  • Exposed neon tubing, neon signs, and LED signs that emulate the general appearance of traditional neon signs.
  • Emitting signs.
  • Roof signs.
  • Any sign with an exposed unshielded light source which does not comply with the terms, conditions and provisions contained in this chapter.
  • Painted wall signs, except as specifically allowed by this chapter.
  • Hot or cold-air balloons, with the exception of those cold air balloons that are granted a temporary use permit. Inflatable shapes or figures with or without words or pictures.
  • Electronic changeable copy signs, except for certain types specifically permitted elsewhere (e.g., time and temperature signs, gas station price signs, certain government or menu board signs).
  • Copycat signs.
  • Awning signs.
  • Trademarked signs or brand signs that do not meet the requirements of this article.
  • Any sign not specifically permitted herein.
  • Flashing, moving and strobe illumination, as well as the illuminated outlining of windows, are prohibited for window signs.
  • Cloth, canvas, fabric, paper, plywood, or other like material which is not intended or designed for permanent display are prohibited for window signs.
  • Window signs are allowed only in ground floor windows.
  • All signs or advertising structures shall be constructed and maintained in strict conformity with city building and electrical codes and all other applicable city regulations.
  • No sign or advertising structure shall be placed, constructed or maintained upon property in any visibility triangle area as described, except for traffic-control signs.
  • A sign shall not directly or indirectly create a traffic or fire hazard, interfere with the free and unobstructed use of streets, sidewalks or building entrances or obstruct clear vision at the intersection of any streets, drives, or public or private vehicular access ways or so that it may be confused with authorized traffic signs or devices.
  • All signs shall be set back a minimum of ten (10) feet from the property line, unless otherwise specified, and a minimum clearance of two (2) feet from rights-of-way, curbs, and sidewalks, or larger clearance if deemed necessary.
  • All signs not mounted to a building shall be separated from another sign on the same parcel by two hundred (200) feet.
  • Lighting of permanent signs shall be white, non-glaring, directed away from adjoining properties, and designed to avoid affecting vision of drivers.
  • All mechanical and electrical elements of a sign must be fully screened or concealed.
  • All sign structures must be landscaped and the landscaping must not interfere with sign visibility.
  • Sign height may not use grade elevations artificially raised solely to increase sign height.

Exempt Signs in Greenacres

  • This chapter does not apply to signs constructed, maintained, or otherwise posted, owned, or leased by the City of Greenacres, Palm Beach County, the State of Florida, or the federal government.
  • This chapter does not regulate official traffic control devices.
  • Traffic-control signs are exempt from the provisions of the visibility triangle.
  • Mandatory address signs do not require a permit.
  • Signs required by federal, state, or local law to warn of danger or prohibit access are allowed provided size and placement follow required standards or are limited to 2 square feet.
  • Official notices posted or displayed by or under the direction of any public or court officer performing official duties are exempt, provided all such signs are removed by the property owner no more than ten (10) days after their purpose has been accomplished or as otherwise required.
  • Window signs do not require a permit if compliant with section 16-937.
  • Temporary signs do not require a permit except those that require temporary use permits as provided in section 16-969.
  • Traffic-control signs in all zoning districts for traffic control purposes are permitted per the specifications set in Sec. 16-989.
  • Sunscreening material, not containing color or lettering (and within reflectance/transmittance limits), does not count toward window sign coverage.

Sign Plan & Submission Notes for Greenacres

  • A master sign plan is required and must be approved before the issuance of a sign building permit to install, alter, construct, post, paint, maintain, or relocate any sign in all commercial centers, plazas, multi-tenant buildings, and planned commercial or residential developments.
  • Existing developments: If a sign owner desires to replace, alter, relocate a sign, or perform repair/maintenance not in compliance with these regulations, a master sign plan must be prepared and submitted.
  • For multi-tenant developments, if an individual sign owner seeks a sign permit for any permanent sign, the property owner shall file a master sign plan within sixty (60) days of the sign permit being filed; sign permits may be withheld until a plan is submitted and approved.
  • All owners of legally nonconforming signs are required to prepare and submit to the city a proposed master sign plan within two (2) years of the effective date of the ordinance.
  • All owners of legally nonconforming signs are required to have an approved master sign plan within three (3) years of the effective date of the ordinance; plan must address the amortization of nonconforming signs; approval does not extend amortization period.
  • Master sign plans must include location, size, copy, type, illumination, and landscaping plan for all signs within a property.
  • Master sign plans are subject to review and approval by the development and neighborhood services department and the development review committee.
  • Sign plans may be amended upon application and approval; amendments cannot increase area or height of any sign by more than 10% over the original master sign program, unless a new approval is sought.

Source: municode municipal code