Sign Regulations in Locust Grove, Georgia

Locust Grove, Georgia has specific sign regulations covering 16 sign types across 14 zoning districts. Regulated sign types include Temporary Sign, Wall Sign, Window Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Locust Grove, Georgia

Sample Sign Requirements in Locust Grove

Sign TypeMax HeightMax AreaSetback
Ground Sign (where allowed for a residential structure as part of a conditional use or government property)20 feet100 sq ft (signable area), 125 sq ft (structure area)5 feet from ROW
Temporary Sign8 feet32 sq ft (signable area), 40 sq ft (structure area)5 feet from ROW
Subdivision Sign8 feet40 sq ft for 1, or 25 sq ft per side for 22 feet from ROW

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Locust GroveFull Coverage

Sign Types Covered

16

  • Temporary Sign
  • Wall Sign
  • Window Sign
  • Ground Sign
  • +2 more types

Zoning Districts

14

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Locust Grove

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

Sign height limits in Locust Grove vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Locust Grove, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Locust Grove, regulated sign types include Temporary Sign, Wall Sign, Window Sign, Ground Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Locust Grove vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Locust Grove are regulated with specific requirements for brightness, animation, and message duration. Locust Grove has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Locust Grove Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Locust Grove, Georgia sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Locust Grove, Georgia Sign Rules at a Glance

Locust Grove, Georgia regulates 16 sign types across 14 zoning districts. Ground Signs in the MHNSO zoning district are capped at 10 feet tall, 32 sq ft (signable), 40 sq ft (structure), and 8 feet wide, with a 5 feet from ROW setback (Sec. 15.24.080.D (MHNSO)). Most commercial signs in Locust Grove require a permit.

Detailed Sign Ordinance Requirements for Locust Grove, Georgia

Sign Rules by Zoning District in Locust Grove (14 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
RA, R-1, R-2, R-3, RD, RMH (No Residential Use/Structure on Lot)420 feet100 sq ft (signable area), 125 sq ft (structure area)
RA, R-1, R-2, R-3, RD, RMH (Residential Structure on Lot)28 feet40 sq ft for 1, or 25 sq ft per side for 2
RM28 feet40 sq ft for 1, or 25 sq ft per side for 2
OI, C-1, C-2, C-3, M-1, M-2 (CSO)520 feet125 sq ft (signable), 175 sq ft (structure)
OI, C-1, C-2, C-3, M-1, M-2 (GSO)535 feet, or up to 50 feet within 800 feet of I-75200 sq ft (signable), 250 sq ft (structure); up to 400 sq ft (signable), 600 sq ft (structure) in intersection of ISO
OI, C-1, C-2, C-3, M-1, M-2 (ISO)570 feet750 sq ft (signable), 850 sq ft (structure)
MHNSO710 feet32 sq ft (signable), 40 sq ft (structure)
CBDSO65 feet50 sq ft
TCU110 feet64 sq ft (signable area), 80 sq ft (structure area)
PD26 feet24 sq ft (signable area), 32 sq ft (structure area)
CSO520 feet125 sq ft (signable), 175 sq ft (structure)
GSO535 feet, or 50 feet within 800 ft of I-75200 sq ft (signable), 250 sq ft (structure); or 400/600 in ISO intersection
ISO570 feet750 sq ft (signable), 850 sq ft (structure)
General Regulations For All Zones110 feet TCU, 6 feet in PD64 sq ft in TCU; 24 sq ft in PD; window signs 10% window space

Zone-by-Zone Sign Requirements in Locust Grove(sample of 3 of 14 zones)

MHNSO

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground Sign10 feet32 sq ft (signable), 40 sq ft (structure)8 feet5 feet from ROW15 feet from ROWUnlock15.24.080.D (MHNSO)
Projecting Sign4 feet32 sq ft8 feet1 along primary road frontageAlong primary road frontageUnlock15.24.080.D, 15.24.050.C (MHNSO)
Wall Sign3Unlock15.24.080.D (MHNSO)
Temporary Sign8 feet20 sq ft (signable), 24 sq ft (structure)5 feet5 feet from interior street ROW1 per public street frontage5 feet from interior street ROWUnlock15.24.080.D (MHNSO)
Subdivision Sign (for business subdivision)8 feet20 sq ft (signable), 32 sq ft (structure)5 feet10 feet from ROW110 feet from ROWUnlock15.24.080.D (MHNSO)
Window SignWindowUnlock15.24.080.D (MHNSO)
Projecting Sign4 feet32 sq ft (signable)8 feet1Along primary road frontageUnlock15.24.080.D; 15.24.050.C.4 (MHNSO)

CSO

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground Sign20 feet125 sq ft (signable), 175 sq ft (structure)15 feet10 feet from ROW110 feet from ROWUnlock15.24.080.D (CSO)
Wall Sign3Building wallUnlock15.24.080.D (CSO)
Temporary Sign8 feet32 sq ft (signable), 40 sq ft (structure)8 feet5 feet from ROW1 per public street frontage5 feet from ROWUnlock15.24.080.D (CSO)
Subdivision Sign (for business subdivision)20 feet125 sq ft (signable), 175 sq ft (structure)15 feet10 feet from ROW110 feet from ROWUnlock15.24.080.D (CSO)
Window SignWindowUnlock15.24.080.D (CSO)

GSO

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground Sign35 feet, or 50 feet within 800 ft of I-75200 sq ft (signable), 250 sq ft (structure); or 400/600 in ISO intersection30 feet, or 40 feet in ISO intersection40 feet from ROW140 feet from ROWUnlock15.24.080.D (GSO)
Wall Sign3Building wallUnlock15.24.080.D (GSO)
Temporary Sign8 feet32 sq ft (signable), 40 sq ft (structure)8 feet5 feet from ROW1 per public street frontage5 feet from ROWUnlock15.24.080.D (GSO)
Subdivision Sign20 feet125 sq ft (signable), 175 sq ft (structure)15 feet10 feet from ROW110 feet from ROWUnlock15.24.080.D (GSO)
Window SignWindowUnlock15.24.080.D (GSO)

PermitPal covers all 14 zoning districts in Locust Grove — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 14 zones for Locust Grove — start free

Prohibited Signs in Locust Grove

  • No signs shall be placed in the public right-of-way or on city property unless part of an approved wayfinding signage plan by the city council, the city downtown development authority, or the Georgia State Department of Transportation.
  • No sign may be placed on any lot that does not meet the minimum requirements of the zoning ordinance and subdivision regulations.
  • No sign shall be erected, relocated, or maintained so as to prevent free ingress to or egress from any door, window, or fire escape, nor shall any sign be attached to any standpipe or fire escape.
  • No sign or structure shall be erected at street intersections that obstructs free and clear vision from vehicles or at any location where it may interfere with, obstruct the view of, or be confused with authorized traffic signs, signals, or devices, or uses words, symbols, or colors to mislead motorists.
  • No sign shall be tacked, painted, posted, marked, or otherwise affixed on trees, utility poles, rocks, the ground itself, or other natural features.
  • No message or advertisement may be displayed on the structural supports of any sign.
  • All signs regulated by this chapter must be maintained in good condition, free from electrical and mechanical hazards. Premises surrounding the signs must be kept sanitary, free of weeds, rubbish, and debris.
  • No sign shall simulate official traffic control or public service signals.
  • It is unlawful to erect flashing signs, inflatable signs, roof signs, tri-vision signs, or aerial view signs at any location in the city.
  • It is unlawful to erect temporary signage that does not conform to the standards of this chapter.
  • No sign may create a hazardous or dangerous lighting condition (e.g., glare/shining into eyes of motorists/pedestrians).
  • No posting or attachment of signs to supports, such as sign structural supports, is allowed.
  • All signs must be constructed and maintained in compliance with the city's building code and applicable setback, zoning, and other relevant codes.
  • No subdivision of a parcel containing a billboard is allowed unless the subdivided lot is large enough to encompass the fall zone of such billboard or sign.
  • No buildings, structures, or appurtenances may be constructed within the fall zone of a billboard, interstate sign, or ground sign greater than thirty-five feet in height.

Exempt Signs in Locust Grove

  • Wall signs one square foot and smaller are exempt from permitting requirements (but must comply with all other provisions).
  • Standard informational signs are exempt from permitting requirements.
  • Projecting signs five square feet and smaller are exempt from permitting requirements.
  • Memorial signs or tablets, names of buildings, and dates of erection cut into masonry or made of incombustible material are exempt from permitting requirements.
  • Signs not visible from any public right-of-way or adjacent property are exempt from all provisions of this chapter.
  • Temporary signs required to be posted by federal law, state law, or the local code are exempt from all provisions of this chapter.
  • Decals affixed to or signs painted on equipment, fuel pumps, or vending equipment, up to four square feet per item, are exempt from all provisions of this chapter.
  • Hand held signs are exempt from permitting requirements.
  • Banners for city-sponsored events are exempt from permit fees.

Sign Plan & Submission Notes for Locust Grove

  • In Planned Development (PD) districts, a uniform design scheme of signs must be established and approved by the planning commission; plans for signs must undergo review and approval as required for other development aspects (see 15.24.070(C)).
  • In Planned Development (PD) or planned center, wayfinding signs may be allowed by an approved master sign plan or common promotional signage plan; such plans govern details like size, height, number, and location.
  • Wayfinding signs on city property, or within the public right-of-way, must be part of an approved wayfinding signage plan by the city council, city DDA, or Georgia Department of Transportation.
  • Variance requests for signage (including for aggregate sign area, sign height, temporary sign extensions) require city council hearing/approval as described in 15.24.070(D); these include written application, justification, and a hearing process.

Source: municode municipal code