Sign Regulations in Washington, Georgia

Washington, Georgia has specific sign regulations covering 20 sign types across 6 zoning districts. Regulated sign types include Wall Sign, Projecting Sign, Freestanding Sign (Ground). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 9, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Washington, Georgia

Sample Sign Requirements in Washington

Sign TypeMax HeightMax AreaSetback
Freestanding Sign (Ground)4 ft16 sq ftMinimum 2 ft from property line
Freestanding Sign (Pole Mounted)25 ft32 sq ftMinimum 2 ft from property line
Billboard40 ft300 sq ft per faceMin 5 ft from right-of-way, 500 ft from another billboard

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for WashingtonFull Coverage

Sign Types Covered

20

  • Wall Sign
  • Projecting Sign
  • Freestanding Sign (Ground)
  • Freestanding Sign (Pole Mounted)
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Washington

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Washington, the height limit for Freestanding Sign (Pole Sign - Customary Home Occupation/Conditional Use) in the Residential Zones is 12 ft (Sec. 58-6(4)(c)). The height limit for Wall Sign in the Downtown Business District (C-3 zoning district) is 2.5 ft. Maximum sign heights range from 5 ft to 40 ft across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Washington require a permit. From the submission notes on this page: Application for a sign permit must be accompanied by plans showing the area of the sign, size and character, method of illumination, exact location, and (for projecting signs) method of fastening and spacing from grade and right-of-way. Run a code check for an exact address to see the permit requirements for that zone.

Washington's sign code covers 20 sign types, including Wall Sign, Projecting Sign, Freestanding Sign (Ground), and Freestanding Sign (Pole Mounted). Most commercial signs need a permit. The ordinance lists 12 exemptions. One of them: Announcement signs do not require a permit. The full list is on this page.

In Washington, Freestanding Sign (Ground) in the C-1, P-1 zoning districts must be set back at least 2 ft from property line. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Washington's sign ordinance that cover digital, changing, or flashing signs: Animated signs are prohibited. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Washington Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Washington, Georgia, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Washington, Georgia Sign Rules at a Glance

Washington, Georgia regulates 20 sign types across 6 zoning districts. Portable Signs (A-frame, Sandwich Board, Sidewalk, Easel) are capped at 5 ft tall and 12 sq ft per side, set back at least 2 ft from street curb. Most commercial signs in Washington require a permit.

Detailed Sign Ordinance Requirements for Washington, Georgia

Sign Rules by Zoning District in Washington (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
C-1, P-1325 ft32 sq ftNot listed
C-2, C-3, C-4, M-1, M-2440 ft300 sq ft per faceNot listed
Residential Zones512 ft25 sq ftNot listed
General Regulations For All Zones725 ftMax 300 sq ft (listing of tenants), 150 sq ft (name of facility only)Not listed
Downtown Business District (C-3 zoning district)65 ft12 sq ftNot listed
Washington Local Historic District, Historic Districts4Not listedNot listedNot listed

Zone-by-Zone Sign Requirements in Washington(sample of 3 of 6 zones)

Residential Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign (Ground Sign - Customary Home Occupation/Conditional Use)4 ft12 sq ftNot listedNot listed1 per customary home occupation/conditional useNot listedNot listedUnlockSec. 58-6(4)(c)
Freestanding Sign (Pole Sign - Customary Home Occupation/Conditional Use)12 ft12 sq ftNot listedNot listed1 per customary home occupation/conditional useNot listedNot listedUnlockSec. 58-6(4)(c)
Identification/Directory Sign (Home Occupation)Not listed1.5 sq ftNot listedNot listed1 per home occupationNot listedNot listedUnlockSec. 58-6(9)(b), (11)(a)
Residential Subdivision Entrance Sign5 ft above grade (from a spot 15 ft out from base)25 sq ftNot listedNot listed1 at each entranceAt entrance(s) to subdivisions of more than 2 parcelsNot listedUnlockSec. 58-6(10)
Other Signs (General Residential Limits)5 ft (measured from a spot 15 ft from base)15 sq ft aggregate, 6 sq ft per signNot listedNot listedNot listedNot listedNot listedUnlockSec. 58-6(11)(a)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignNot listedVaries (see formula)Not listedNot listed1 per frontageEach building frontage; separate calculation for each street frontage. Wall signs must not be painted directly on wall surface.Not listedUnlockSec. 58-6(8), Appendix A(5), Sec. 58-8(11)
Awning/Canopy/Marquee SignNot listed24 sq ft (Awning); 6 sq ft (under-canopy, marquee, or face)Not listedNot listed1 per canopy/marquee/awningOn/under awning, canopy, or marqueeNot listedUnlockSec. 58-6(3), Appendix A(4)
Projecting SignNot listed12 sq ftNot listedNot listed1 per businessMay project over right-of-way, min 2 ft from curb line, 9 ft clearance above sidewalk, 15 ft over road/drive/alleyNot listedUnlockSec. 58-6(6), Appendix A(7)
Window Sign (Interior)Not listedNot listedNot listedNot listedNot listedInside or upon window facing exterior viewNot listedUnlockSec. 58-5(1)(j), Appendix A(8), Sec. 58-8(4)
Portable Sign (A-frame, Sandwich Board, Sidewalk, Easel)5 ft12 sq ft per sideNot listedMinimum 2 ft from street curb1 per businessOn sidewalk during business hours only; min 2 ft setback from street curbNot listedUnlockSec. 58-6(5), Appendix A(9)
Identification/Directory SignNot listedNot listedNot listedNot listed1 per building side per businessPer building side adjoining streetNot listedUnlockSec. 58-6(9)(a)
Shopping Center Sign25 ftMax 300 sq ft (listing of tenants), 150 sq ft (name of facility only)Not listedNot listed1 per shopping centerNot listedNot listedUnlockSec. 58-6(7)

Downtown Business District (C-3 zoning district)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign2.5 ftAs above (formula)Not listedNot listedNot listedAbove entrance or display window, below cornice/transomNot listedUnlockSec. 58-7(a), Appendix A(1)(b), (5)
Awning SignNot listedNot listedNot listedNot listedNot listedOn the skirt of the awningNot listedUnlockSec. 58-7(a), Appendix A(1)(a), (4)
Freestanding/Ground Sign4 ft12 sq ftNot listedNot listedNot listedNear road, not attached to buildingNot listedUnlockSec. 58-7(a), Appendix A(1)(c), (6)
Window SignNot listedNot listedNot listedNot listedNot listedDisplay window or upper floor window, glazing of doorsNot listedUnlockSec. 58-7(a), Appendix A(1)(d), (8)
Projecting SignNot listed12 sq ftNot listedNot listed1 per businessAttached to building, at least 1 ft from curb-lineNot listedUnlockSec. 58-7(a), Appendix A(1)(e), (7)
Portable Sign (A-frame, Sandwich board, Sidewalk, Easel)5 ft12 sq ft per sideNot listedMin 2 ft from curb1 per businessOn sidewalk in front of business, business hours onlyNot listedUnlockSec. 58-7(a), Appendix A(1)(f), (9)

PermitPal covers all 6 zoning districts in Washington. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Washington

  • No sign other than official signs placed by a government body may be constructed or placed within any public right-of-way.
  • No sign shall be attached to or painted on any telephone pole, power pole, tree, rock, or other natural object.
  • No sign giving off light resulting in glare, blinding, or any other such adverse effect on traffic shall be erected or maintained.
  • The light from illuminated signs must not adversely affect adjacent properties or roadways, and no direct light shall be cast upon adjacent properties.
  • No illuminated sign shall be constructed or maintained within 50 feet of any residential district.
  • Lit signs must be externally illuminated with a shielded indirect light source, except internally lit signs are only allowed in the C-2 zoning district.
  • Roof signs are prohibited.
  • Animated signs are prohibited.
  • Signs on public rights-of-way other than publicly owned or maintained signs are prohibited.
  • Window signs which exceed 20 percent of the window area are prohibited.
  • Signs which contain words, pictures or statements which are obscene, as defined by O.C.G.S. 16-12-80, are prohibited.
  • Signs which simulate an official traffic control or warning sign or hide from view any traffic or street sign, signal or public service sign are prohibited.
  • Signs which emit or utilize in any manner any sound capable of being detected on any traveled road or highway by a person with normal hearing are prohibited.
  • Signs which interfere with road or highway visibility or obstruct or otherwise interfere with the safe and orderly movement of traffic are prohibited.
  • Signs erected by nailing, fastening or affixing the sign in any manner to any tree, post, curve, utility pole or other structure except as set forth herein are prohibited.
  • Signs on public right-of-way or private property, other than with permission of the property owner, will be removed.
  • Internally lit signs are prohibited in all zoned districts except C-2.
  • It is unlawful to erect or place any sign which does not conform to the requirements of this chapter.
  • All signs must be constructed in accordance with the adopted edition of the International Building Code, Appendix H, and the adopted edition of the National Electric Code.

Exempt Signs in Washington

  • Announcement signs do not require a permit.
  • Commemorative signs no larger than eight square feet, subject to building official approval, do not require a permit.
  • Construction signs less than 16 square feet, displayed during the specified period related to construction, do not require a permit.
  • Instructional/directional signs not exceeding two square feet within the public right-of-way for churches, schools, and nonprofit institutions (not erected in center parkways and subject to setback/hanging requirements) do not require a permit.
  • Official signs do not require a permit.
  • Political signs do not require a permit.
  • Real estate signs do not require a permit.
  • Special events/temporary signs less than 16 square feet, for a period of seven days prior to the event and up to two days after, do not require a permit.
  • Yard sale signs do not require a permit.
  • Window signs (interior) intended to be seen from the exterior do not require a permit.
  • Non-permitted (exempt) signs still must comply with the remainder of the ordinance.
  • Non-permitted signs do not count toward the total number of permitted signs allowed.

Sign Plan & Submission Notes for Washington

  • Application for a sign permit must be accompanied by plans showing the area of the sign, size and character, method of illumination, exact location, and (for projecting signs) method of fastening and spacing from grade and right-of-way.
  • Applicants for sign permits within historic districts must obtain approval and a certificate of appropriateness from the historic preservation commission, following guidelines in Appendix B.
  • Upon request of the building official, the applicant must submit any additional information deemed necessary as part of the application.
  • Permit applications for signs in certain areas (e.g., downtown business district (C-3), Washington local historic district) must comply with design guidelines set forth in appendix A and B.
  • Buildings with multiple tenants should consider unified signage, using a central directory sign or coordinated wall plaque or freestanding sign, as recommended in Appendix A.
  • Variances can be considered for franchise agreements, national logos, or established business logos in cases where franchise signage cannot meet design guidelines.

Source: municode municipal code