Sign Regulations in Bensenville, Illinois
Bensenville, Illinois has specific sign regulations covering 26 sign types across 5 zoning districts. Regulated sign types include Monument Sign, Awning Sign, Canopy-Mounted Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 19, 2025
Sign Regulation Overview for Bensenville, Illinois
Sample Sign Requirements in Bensenville
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Monument Sign | 8 ft | 50 sq ft | 5 ft from front/corner side, 10 ft from interior side |
| Awning Sign (Non-Residential/Multiple-Unit Use Only) | — | 50% of area of awning | — |
| Canopy-Mounted Sign (Non-Residential/Multiple-Unit Use Only) | 2 ft (as measured from top of canopy) | — | — |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
26
- Monument Sign
- Awning Sign
- Canopy-Mounted Sign
- Manually Changeable Copy Sign
- +2 more types
Zoning Districts
5
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Other Cities in Illinois
Frequently Asked Questions
In Bensenville, monument signs are limited to 8 ft. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.
To get a sign permit in Bensenville, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Bensenville, regulated sign types include Monument Sign, Awning Sign, Canopy-Mounted Sign, Manually Changeable Copy Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
In Bensenville, monument signs typically require a 5 ft from front/corner side, 10 ft from interior side setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.
Digital and LED signs in Bensenville are regulated with specific requirements for brightness, animation, and message duration. Bensenville has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Bensenville Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Bensenville, Illinois sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Bensenville, Illinois Sign Rules at a Glance
Bensenville, Illinois regulates 26 sign types across 5 zoning districts. Monument Signs in the Residential Districts (R-1, R-2, R-3, R-4, R-5, R-6), Single-Dwelling Unit Zoning Districts zoning district are capped at 8 ft tall and 50 sq ft, with a 5 ft from front/corner side, 10 ft from interior side setback (Sec. 10-10-5.B.8). Most commercial signs in Bensenville require a permit.
Detailed Sign Ordinance Requirements for Bensenville, Illinois
Sign Rules by Zoning District in Bensenville (5 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Residential Districts (R-1, R-2, R-3, R-4, R-5, R-6), Single-Dwelling Unit Zoning Districts | 8 | 8 ft | 50 sq ft | — |
| Commercial Districts (C-1, C-2) | 11 | 8 ft | 50% of area of awning | — |
| Industrial Districts (I-1, I-2) | 8 | 8 ft | 50% of area of awning | — |
| Non-Residential Districts | 4 | 8 ft | 32 sq ft | — |
| General Regulations For All Zones | 2 | Driveway access: 4 ft | Driveway access: 4 sq ft; warning: 2 sq ft; street address: 2 sq ft (Single-Dwelling), 6 sq ft (other districts); headstone, historical: 4 sq ft; parking lot: 6 sq ft; residential sign: 2 sq ft | — |
Zone-by-Zone Sign Requirements in Bensenville(sample of 3 of 5 zones)
Residential Districts (R-1, R-2, R-3, R-4, R-5, R-6), Single-Dwelling Unit Zoning Districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Monument Sign | 8 ft | 50 sq ft | — | 5 ft from front/corner side, 10 ft from interior side | 1 per street frontage for lots < 300 ft width; 2 per street frontage if lot width >= 300 ft (150 ft minimum distance between monument signs) | Minimum 5 ft from any front or corner side lot line and 10 ft from any interior side lot line | — | Unlock | 10-10-5.B.8 |
| Awning Sign (Non-Residential/Multiple-Unit Use Only) | — | 50% of area of awning | — | — | Per facade/tenant frontage | Can project from front, side, rear, or corner side facade; max 4 ft from facade; min 8 ft above grade | — | Unlock | 10-10-5.B.1 |
| Canopy-Mounted Sign (Non-Residential/Multiple-Unit Use Only) | 2 ft (as measured from top of canopy) | — | — | — | 1 per tenant entrance | May project max 4 ft from facade; minimum 8 ft above grade; shall not extend below the lowest point of the canopy | — | Unlock | 10-10-5.B.2 |
| Wall Sign (Non-Residential/Multiple-Unit Use Only) | — | — | — | — | 1 per street frontage per tenant; 1 additional per tenant on side or rear | Affixed to building facade, not projecting >1 ft from face; shall not project above top of wall | — | Unlock | 10-10-5.B.11 |
| Window Sign (Non-Residential/Multiple-Unit Use Only) | — | 25% of ground floor window area per establishment | — | — | — | Ground floor window area or above, per facade | — | Unlock | 10-10-5.B.12 |
| Manually Changeable Copy Sign (Non-Residential Use Only) | — | — | — | — | 1 per zoning lot | As component of marquee or monument sign | — | Unlock | 10-10-5.B.6 |
| Electronic Message Sign (Only for Parks, Schools, Libraries, Places of Worship) | — | — | — | — | 1 per zoning lot | As component of marquee or monument sign | — | Unlock | 10-10-5.B.4 |
| Permanent Signs Exempt from Permit (e.g., Residential Sign, Warning Sign, Driveway Access Sign, Street Address Sign, Headstone, Historical Marker, etc.) | Driveway access: 4 ft; others N/A | Residential sign: 2 sq ft; warning sign: 2 sq ft; driveway access sign: 4 sq ft; street address sign: 2 sq ft; historical marker: 4 sq ft; parking lot signs: 6 sq ft | — | — | Residential sign: 1 per lot; driveway: 2 per driveway access | Residential sign: wall or window, 1 per lot; warning: up to 2 per lot; driveway signs: per driveway access | — | Unlock | 10-10-5.A |
Commercial Districts (C-1, C-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | — | 50% of area of awning | — | — | Per awning facade/tenant frontage | Can project from front/side/rear/corner facade, max 4' from facade, min 8' above grade | — | Unlock | 10-10-5.B.1 |
| Canopy-Mounted Sign | 2 ft (as measured from top of canopy) | — | — | — | 1 per tenant entrance | Canopy projecting max 4' from building; sign minimum 8' above grade, shall not extend below lowest point of canopy | — | Unlock | 10-10-5.B.2 |
| Drive-Through Sign (C-2 only) | 6 ft | 50 sq ft | — | 15 ft from Residential lots | 1 per drive-through lane; 1 additional presell per establishment | Min 15 ft from lot line of any lot in Residential Zoning; wall/monument sign format | — | Unlock | 10-10-5.B.3 |
| Electronic Message Sign (C-2 only) | — | — | — | — | 1 per zoning lot | As component of marquee or monument sign | — | Unlock | 10-10-5.B.4 |
| Hanging Sign | — | 8 sq ft | — | — | 1 per street frontage per tenant | Underneath awning or canopy; not attached to marquee signs; min 8' above grade | — | Unlock | 10-10-5.B.5 |
| Manually Changeable Copy Sign | — | — | — | — | 1 per zoning lot | As component of marquee or monument sign | — | Unlock | 10-10-5.B.6 |
| Monument Sign | 8 ft | 50 sq ft | — | 5 ft from front/corner side, 10 ft from interior side | 1 per street frontage if <300 ft width, 2 if >=300 ft with 150 ft min between | Min 5' from front/corner side, 10' from interior side lot line | — | Unlock | 10-10-5.B.8 |
| Projecting Sign | 6 ft | 16 sq ft | — | — | 1 per street frontage per tenant | Min 8' above grade; must not project more than 5' from building face; not above roof | — | Unlock | 10-10-5.B.9 |
Industrial Districts (I-1, I-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | — | 50% of area of awning | — | — | — | May project up to 4' from any facade; min 8' above grade | — | Unlock | 10-10-5.B.1 |
| Canopy-Mounted Sign | 2 ft (as measured from top of canopy) | — | — | — | 1 per tenant entrance | Can project max 4' from facade, min 8' above grade, not below lowest point of canopy | — | Unlock | 10-10-5.B.2 |
| Drive-Through Sign (I-2 only) | 6 ft | 50 sq ft | — | 15 ft from any lot in Residential District | 1 per drive-through lane; plus 1 additional presell per establishment | Min 15 ft from Residential Zoning District lot line | — | Unlock | 10-10-5.B.3 |
| Manually Changeable Copy Sign | — | — | — | — | 1 per zoning lot (alternating with electronic message sign) | As component of marquee or monument sign | — | Unlock | 10-10-5.B.6 |
| Monument Sign | 8 ft | 50 sq ft | — | 5 ft from front/corner, 10 ft from interior | 1 per street frontage <300' width; 2 per street frontage >=300', 150 ft minimum distance | Min 5' from front/corner, 10' from interior | — | Unlock | 10-10-5.B.8 |
| Roof Sign (Painted) (I-1/I-2 only) | — | — | — | — | 1 per qualifying roof | Painted directly on roof, not visible from ROW at ground; only for roofs >=250,000 sq ft | — | Unlock | 10-10-5.B.10 |
| Wall Sign | — | — | — | — | 1 per street frontage per tenant; 1 additional per tenant side/rear | On building facade, not >1' from face, not above roof/wall | — | Unlock | 10-10-5.B.11 |
| Window Sign | — | 25% of ground floor window per establishment | — | — | — | Windows on ground floor and above | — | Unlock | 10-10-5.B.12 |
PermitPal covers all 5 zoning districts in Bensenville — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 5 zones for Bensenville — start freeProhibited Signs in Bensenville
- It is unlawful to erect attention getting devices in any zoning district.
- It is unlawful to erect banner flag signs in any zoning district.
- It is unlawful to erect bench signs in any zoning district.
- It is unlawful to erect flashing signs in any zoning district.
- It is unlawful to erect inflatable devices in any zoning district.
- It is unlawful to erect moving signs or other advertising devices with moving, revolving, or rotating parts, except for barber poles, electronic message signs, flags, inflatable devices, pennant signs, signs displaying time and temperature, street clocks, and other signs as established by this chapter.
- It is unlawful to erect obscene signs in any zoning district.
- It is unlawful to erect off-premises signs in any zoning district.
- It is unlawful to erect pole signs in any zoning district.
- It is unlawful to erect portable signs in any zoning district.
- It is unlawful to erect roof signs (building-mounted) in any zoning district.
- It is unlawful to erect signs or advertising devices that interfere with, obstruct the view of, or are confused with any traffic sign, signal, or device because of position, shape, illumination, or color.
- It is unlawful to erect snipe signs in any zoning district.
- It is unlawful to erect vehicle signs in any zoning district.
- It is unlawful to erect video display signs in any zoning district.
- No sign may be constructed, erected, or maintained in a manner that is unsafe or a danger to the public.
- No sign illumination may be combined with reflective materials such as mirrors, polished metal, or highly-glazed tiles which would increase glare.
- Series lighting and illuminated tubing shall not be used to trim windows or architectural features.
- It is unlawful for any person to willfully deface, injure, remove, or interfere with any traffic sign or signal, or any street name.
- It is unlawful to publish, print, or display any sign, notice, or advertisement related to the sale or rental of dwellings that indicates any discriminatory preference or limitation based on protected characteristics.
Exempt Signs in Bensenville
- Permanent signs designated as exempt in section 10-10-5A: driveway access signs, flags, government signs, headstones, historical markers, miscellaneous information signs, parking lot signs, residential signs, street address signs (within specified size and illumination), warning signs, and wayfinding signs are exempt from permit requirements across all zoning districts if they meet the listed standards.
- Temporary signs designated as exempt in section 10-10-6B: A-frame signs, temporary window signs, vehicle for sale signs, and yard signs are exempt from permit requirements if they meet the listed standards.
- Uses that remain in operation between 11:00 p.m. and 6:00 a.m. are exempt from the sign illumination turn-off requirement during their period of operation.
- Neon tubing for neon signs and bare bulbs for marquee signs are exempt from the requirement to shield illumination to prevent direct light or glare.
Sign Plan & Submission Notes for Bensenville
- A Master Sign Plan is required for all non-residential developments with three or more tenants. All signs within the development will be reviewed for consistency of background or text color, lettering style, mounting height, materials, and sign type.
- Approval of a Master Sign Plan is by the Zoning Administrator. If denied, the applicant may seek a Variation (variance) in accordance with §10-3-4.
- All signs that are not specifically exempt require a sign permit in accordance with section 10-3-9. Permit application is reviewed by the Zoning Administrator.
- For monument signs, a landscape plan must be submitted as part of the sign permit application and approved by the Zoning Administrator. Alternative landscape designs may be approved.
- Permanent and temporary signs listed as exempt in sections 10-10-5A and 10-10-6B do not require permits; all other signs generally do.