Sign Regulations in Berwyn, Illinois

Berwyn, Illinois has specific sign regulations covering 21 sign types across 11 zoning districts. Regulated sign types include Canopy-Mounted Sign, Projecting Sign, Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 19, 2025

Sign Regulation Overview for Berwyn, Illinois

Sample Sign Requirements in Berwyn

Sign TypeMax HeightMax AreaSetback
Historical Marker4 sq ft
Parking Lot Sign6 sq ft per sign
Street Address Sign2 sq ft per sign

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for BerwynFull Coverage

Sign Types Covered

21

  • Canopy-Mounted Sign
  • Projecting Sign
  • Wall Sign
  • Window Sign
  • +2 more types

Zoning Districts

11

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

Sign height limits in Berwyn vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Berwyn, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Berwyn, regulated sign types include Canopy-Mounted Sign, Projecting Sign, Wall Sign, Window Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Berwyn vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Berwyn are regulated with specific requirements for brightness, animation, and message duration. Berwyn has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Berwyn Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Berwyn, Illinois sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Berwyn, Illinois Sign Rules at a Glance

Berwyn, Illinois regulates 21 sign types across 11 zoning districts. Drive-Through Signs in the C-2 zoning district are capped at 7 ft tall and 50 sq ft, with a 15 ft from residential lot line setback (Sec. §1476.05(B)(4)). Most commercial signs in Berwyn require a permit.

Detailed Sign Ordinance Requirements for Berwyn, Illinois

Sign Rules by Zoning District in Berwyn (11 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones56 sq ft per sign
C-11020 ft40 sq ft
C-21220 ft50 sq ft
C-3118 ft50 sq ft
C-41232 ft50 sq ft
I1132 ft50 sq ft
P1120 ft50 sq ft
R-1, R-2, R-3, R-412 sq ft
Residential Districts (R-1, R-2, R-3, R-4)36 ft32 sq ft
Non-residential uses in residential districts43 ft cabinet sign, otherwise per formula
1 more zone in PermitPal — start free

Zone-by-Zone Sign Requirements in Berwyn(sample of 3 of 11 zones)

C-2

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Canopy-Mounted Sign2 ft1 per street frontageFront/corner side facade on canopy; canopy not >5 ft projection; min 8 ft above gradeUnlock§1476.05(B)(2)
Driveway Entrance/Exit Sign4 ft4 sq ft1 per driveway access plus 1 per intersection1 per driveway access; 1 extra per intersection of driveways (if >100 ft lot width)Unlock§1476.05(B)(3)
Drive-Through Sign7 ft50 sq ft15 ft from residential lot line1 per drive-through laneMin 15 ft from residential lot line; 1 per drive-through laneUnlock§1476.05(B)(4)
Marquee Sign8 ftMin 1 ft from edge of facade1 per zoning lotProject from front or corner side facade (not beyond curb line); must be on building with 3+ storiesUnlock§1476.05(B)(5)
Monument Sign6 ft32 sq ft10 ft from interior side lot line1 or 2 per frontage as width allows1 per frontage (<300 ft width), 2 per frontage (≥300 ft, min 50 ft between); not both pole & monumentUnlock§1476.05(B)(6)
Pole Sign20 ft40 sq ft5 ft from interior side lot line1 per lotUnlock§1476.05(B)(7)
Projecting Sign8 ft24 sq ft1 per street frontage per ground floor tenantAt least 8 ft above grade, extends up to 5 ft from building, not above roof, attached to facade.Unlock§1476.05(B)(8)
Wall Sign3 ft (cabinet sign, otherwise per formula)5 ft (cabinet sign)1/tenant/street frontage; +1 on side/rear if adjacent to parkingMin 8 ft above grade, not >1 ft from wall, not above wall top. Placement uniform in multitenant buildings.Unlock§1476.05(B)(9)

C-3

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Canopy-Mounted Sign2 ft1 per street frontageFront/corner side facade canopy; canopy not >5 ft protrusion; min 8 ft above gradeUnlock§1476.05(B)(2)
Driveway Entrance/Exit Sign4 ft4 sq ft1 per driveway; 1 per intersection1 per driveway; 1 extra per intersection if >100 ft lot widthUnlock§1476.05(B)(3)
Drive-Through Sign7 ft50 sq ft15 ft from residential1 per drive-through laneMin 15 ft from residential; 1 per drive-through laneUnlock§1476.05(B)(4)
Marquee Sign8 ft1 ft from facade edge unless wraps around corner1 per lotProject from front/corner side facade; not beyond curb; min 8 ft above grade; min 1 ft from edge (unless corner)Unlock§1476.05(B)(5)
Monument Sign6 ft32 sq ft10 ft from interior side lot line1 or 2 per frontage1 per frontage (<300 ft width), 2 per frontage (≥300 ft, 50 ft apart min). Not both pole & monument.Unlock§1476.05(B)(6)
Projecting Sign6 ft16 sq ft1 per street frontage per ground floor tenantMin 8 ft above grade; projects max 5 ft; not above roof; attached to facade.Unlock§1476.05(B)(8)
Wall Sign3 ft cabinet sign; otherwise per formula5 ft cabinet sign1 per street frontage per tenant; 1 additional side/rear if parkingMin 8 ft above grade; uniform in multi-tenant; not more than 1 ft out from wall; not above wall top.Unlock§1476.05(B)(9)
Electronic Message Sign1 per lotComponent sign onlyUnlock§1476.05(B)(11)

C-4

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Canopy-Mounted Sign2 ft1 per street frontageFront/corner side; canopy not >5 ft projection; min 8 ft above gradeUnlock§1476.05(B)(2)
Driveway Entrance/Exit Sign4 ft4 sq ft1 per driveway; 1 per intersection1 per driveway; 1 extra per intersection if >100 ft lot widthUnlock§1476.05(B)(3)
Drive-Through Sign7 ft50 sq ft15 ft from residential1 per drive-through laneMin 15 ft from residential; 1 per laneUnlock§1476.05(B)(4)
Marquee Sign8 ft1 ft from facade edge unless wraps corner1 per lotProtrude from front/corner side; not beyond curb; min 8 ft above grade, min 1 ft from edge (unless corner)Unlock§1476.05(B)(5)
Monument Sign8 ft48 sq ft10 ft from interior side lot line1 or 2 per frontage1 per street frontage <300 ft width, 2/frontage if ≥300 ft and 50 ft apart; not both pole & monumentUnlock§1476.05(B)(6)
Pole Sign32 ft48 sq ft (56 sq ft if C-4/Ogden Ave)5 ft from interior side lot line1 per lotUnlock§1476.05(B)(7)
Projecting Sign8 ft24 sq ft1 per street frontage/tenantMin 8 ft above grade; project max 5 ft; not above roof; attached to facade.Unlock§1476.05(B)(8)
Wall Sign3 ft cabinet sign, otherwise per formula5 ft cabinet sign1/tenant/street; +1 side/rearMin 8 ft above; not >1 ft out; not above wall; uniform in multi-tenantUnlock§1476.05(B)(9)

PermitPal covers all 11 zoning districts in Berwyn — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 11 zones for Berwyn — start free

Prohibited Signs in Berwyn

  • It is unlawful to erect attention getting devices in any zoning district.
  • It is unlawful to erect banner flag signs in any zoning district.
  • It is unlawful to erect bench signs in any zoning district.
  • It is unlawful to erect video display signs in any zoning district.
  • It is unlawful to erect flashing signs in any zoning district.
  • It is unlawful to erect moving signs or other advertising devices with moving, revolving, or rotating parts, except barber poles, electronic message signs, flags, inflatable devices, pennant signs, signs displaying time and temperature, street clocks, or as otherwise established.
  • It is unlawful to erect obscene signs in any zoning district.
  • It is unlawful to erect off-premises signs in any zoning district.
  • It is unlawful to erect portable signs in any zoning district.
  • It is unlawful to erect roof signs in any zoning district.
  • No sign or advertising device shall interfere with, obstruct the view of, or be confused with any traffic sign, signal, or device because of its position, shape, illumination, or color.
  • It is unlawful to erect snipe signs in any zoning district.
  • It is unlawful to erect vehicle signs in any zoning district.
  • No sign may be constructed, erected, or maintained in a manner that is unsafe, insecure, or a danger to the public.
  • Signs may only be placed on public property by a government agency, as authorized by the chapter or the Building Director. Any sign placed on public property without authorization may be removed without notice.
  • Signs may only be placed on private property with prior consent of the property owner and, if applicable, an approved sign permit issued by the city.
  • A sign mounted on the exterior of a building shall not conceal any windows, doors, or unique architectural features (except window signs).
  • A sign shall not obstruct free and clear vision at any street, intersection, driveway, or parking lot entrance or exit.
  • In residential districts, no sign shall be placed to create a visibility obstruction for motorists, bicyclists, or pedestrians, and no sign shall exceed three feet in height within 25 feet of two or more intersecting streets.
  • All illuminated signs must not cause direct light or glare on adjacent rights-of-way and surrounding properties. No sign illumination may be combined with reflective materials that would increase glare.
  • All illuminated signs must be turned off from 11:00 p.m. until 7:00 a.m., or 30 minutes after close of business, whichever is later, unless the use is in operation during that period.
  • Temporary signs shall not be illuminated.
  • No person shall attach or place any sign, poster, handbill or other thing to or on a tree growing in any street or highway of the city or to or on any device intended to protect a tree.

Exempt Signs in Berwyn

  • Permanent signs exempt from permit requirements (provided they comply with specified standards): alteration and maintenance activities (not involving structural changes), flags, government signs (subject to City Council approval), headstones, historical markers, home occupation signs, miscellaneous information signs, parking lot signs, street address signs, warning signs.
  • Temporary signs exempt from permit requirements (provided they comply with specified standards): A-frame signs, construction signs, garage or yard sale signs, political signs, real estate signs, and temporary window signs.
  • Signs designated as classic signs are exempt from all of the requirements of this chapter in accordance with the provisions of §1476.09.
  • Uses operating between 11:00 p.m. and 7:00 a.m. are exempt from sign illumination shut-off requirements during the period of operation.

Sign Plan & Submission Notes for Berwyn

  • A sign permit is required in order to erect, construct, alter, or relocate a sign, except for certain exempt permanent and temporary signs as specified in the ordinance.
  • Applications for sign permits and any required plans are reviewed by the Building Director for compliance and issuance.
  • Structural plans and specifications for proposed signs, including electronic components and proposed location, must be submitted with permit applications.
  • If denied, applicants may appeal to the Zoning, Planning, and Development Commission or reapply within 30 days without a new fee.
  • Major sign variations require a public hearing and approval by the City Council; minor sign variations may be approved by the Building Director. Applications for sign variations must be submitted along with a sign permit application.
  • Classic sign designation requires submittal of a maintenance or restoration plan for review.
  • A sign permit is generally not required for activities or signs explicitly listed as 'exempt' in §1476.05(A) and §1476.06(B).
  • Banner signs and inflatable devices (temporary signs with permit requirement) require a sign permit and compliance with applicable standards.
  • Variation approvals expire if a sign permit is not obtained for the sign within six months of approval of the sign variation.