Dyer, Indiana has specific sign regulations covering 29 sign types across 4 zoning districts. Regulated sign types include Permanent Sign (over 12 sq ft), Permanent Sign (12 sq ft or less), Temporary Sign (12 sq ft or less). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 19, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Dyer, Indiana

Sample Sign Requirements in Dyer

Sign TypeMax HeightMax AreaSetback
Permanent Sign (over 12 sq ft)10 ft50 sq ft gross surface areaAt least 5 ft from any property line
Permanent Sign (12 sq ft or less)10 ft12 sq ft gross surface areaAt least 5 ft from any property line
Temporary Sign (12 sq ft or less)10 ft12 sq ft gross surface areaAt least 5 ft from any property line

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for DyerFull Coverage

Sign Types Covered

29

  • Permanent Sign (over 12 sq ft)
  • Permanent Sign (12 sq ft or less)
  • Temporary Sign (12 sq ft or less)
  • Home Operation Sign
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

In Dyer, the height limit for Permanent Sign (over 12 sq ft) in the Residential Districts is 10 ft (Sec. 10-146.5(1)). Maximum sign heights range from 3 ft to 10 ft across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Dyer require a permit. From the submission notes on this page: No general requirement for a 'master sign plan' is stated in the provided text, but planned unit developments and shopping centers have specific signage allowances based on the number of tenants. Run a code check for an exact address to see the permit requirements for that zone.

Dyer's sign code covers 29 sign types, including Permanent Sign (over 12 sq ft), Permanent Sign (12 sq ft or less), Temporary Sign (12 sq ft or less), and Home Operation Sign. Most commercial signs need a permit. The ordinance lists 6 exemptions. One of them: Temporary signs measuring twelve (12) square feet or less in gross surface area are exempt from the requirement to obtain a permit unless illuminated. The full list is on this page.

In Dyer, Freestanding Shopping Center Sign (setback > 50 ft) in the B-1 Business Districts, B-2 Districts, B-3 Districts, I Districts must be set back at least 5 ft from property line (Sec. 10-146.6(2)a). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Dyer's sign ordinance that cover digital, changing, or flashing signs: Flashing signs which flash in excess of six (6) times per minute except for electronic text messaging centers. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Dyer Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Dyer, Indiana, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Dyer, Indiana Sign Rules at a Glance

Dyer, Indiana regulates 29 sign types across 4 zoning districts. Home Operation Signs in the Residential Districts are capped at 10 ft tall and 1 sq ft, set back at least 5 ft from any property line (Sec. 10-146.5(1)). Most commercial signs in Dyer require a permit.

Detailed Sign Ordinance Requirements for Dyer, Indiana

Sign Rules by Zoning District in Dyer (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential Districts510 ft50 sq ft gross surface areaNot listed
B-1 Business Districts, B-2 Districts, B-3 Districts, I Districts233 ftBased on building frontage; see formula; up to 100 sq ft for freestanding signs.Not listed
Special Use District (SUD)2Not listed100 sq ftNot listed
General Regulations For All Zones2Not listed32 sq ftNot listed

Zone-by-Zone Sign Requirements in Dyer(sample of 3 of 4 zones)

Residential Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Permanent Sign (over 12 sq ft)10 ft50 sq ft gross surface areaNot listedAt least 5 ft from any property lineNot listedAt least 5 ft from any property line; cannot overhang public street, alley or sidewalkNot listedUnlockSec. 10-146.5(1)
Permanent Sign (12 sq ft or less)10 ft12 sq ft gross surface areaNot listedAt least 5 ft from any property lineNot listedAt least 5 ft from any property line; cannot overhang public street, alley or sidewalkNot listedUnlockSec. 10-146.5(1)
Temporary Sign (12 sq ft or less)10 ft12 sq ft gross surface areaNot listedAt least 5 ft from any property lineNot listedAt least 5 ft from any property line; cannot overhang public street, alley or sidewalkNot listedUnlockSec. 10-146.5(1)
Home Operation Sign10 ft1 sq ftNot listedAt least 5 ft from any property line1 per home operationAt least 5 ft from any property line; cannot overhang public street, alley or sidewalkNot listedUnlockSec. 10-146.5(1)
Temporary Sign (Yard/Garage Sale Pennants/Streamers)Not listedNot listedNot listedNot listedNot listedNot listedNot listedUnlockSec. 10-146.5(2)c,d

B-1 Business Districts, B-2 Districts, B-3 Districts, I Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Permanent Sign (over 12 sq ft)Not listedBased on building frontage; see formula; up to 100 sq ft for freestanding signs.Not listed5 ft minimum from any public right-of-way1 freestanding sign per business frontage; options for additional per side/rear lot/shopping centersBuilding wall or as freestanding sign; signs must be set back a minimum of 5 ft from any public right-of-wayNot listedUnlockSec. 10-146.6(1)c,d,e; Sec. 10-146.7
Permanent Sign (12 sq ft or less)Not listed12 sq ft gross surface areaNot listed5 ft from public right-of-wayNot listedMinimum 5 ft from public ROWNot listedUnlockSec. 10-146.6(1)
Temporary Sign (12 sq ft or less)Not listed12 sq ft gross surface areaNot listed5 ft from public right-of-wayNot listedMinimum 5 ft from public ROWNot listedUnlockSec. 10-146.6(1)
Freestanding Sign (front freestanding sign)Not listed100 sq ftNot listedMin 5 ft from property lineSee additional_requirementsMinimum 5 ft from ROW; in front; rear/side freestanding sign also possible w/ conditionsNot listedUnlockSec. 10-146.6(1)d; (2)a,b
Window/Door SignNot listed6 sq ft per individual sign, up to 9 sq ft total for both; max 2 per business (one per window/door)Not listedNot listed2 per business (one per window/door)Painted on window/doorNot listedUnlockSec. 10-146.6(1)g,k
BannerNot listed32 sq ft (or per formula if higher)Not listedNot listed1 per frontage, 2 for corner lotsOn building wallNot listedUnlockSec. 10-146.6(1)q
Freestanding Shopping Center Sign (setback > 50 ft)Not listed100 sq ft per display areaNot listedMin 5 ft from property lineper 6 tenants or fractionMin 5 ft to property line; shopping centers only (all buildings setback >50 ft)Not listedUnlockSec. 10-146.6(2)a
Freestanding Business Sign (building setback > 50 ft)Not listed100 sq ftNot listedMin 5 ft to property line1Min 5 ft from property line; not shopping centers, not gas or garagesNot listedUnlockSec. 10-146.6(2)b

Special Use District (SUD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign (SUD)Not listed100 sq ftNot listedNot listedNot listedRegardless of setback from property line; may extend over sidewalk with min 8 ft clearanceNot listedUnlockSec. 10-146.12(1)-(2)
Wall Mounted Sign (SUD)Not listedNot listedNot listedNot listedNot listedRegardless of setback from property line; may extend over sidewalk with min 8 ft clearanceNot listedUnlockSec. 10-146.12(1)-(2)

PermitPal covers all 4 zoning districts in Dyer. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Dyer

  • Flashing signs which flash in excess of six (6) times per minute except for electronic text messaging centers.
  • Moving signs which move or rotate more than one (1) revolution per minute.
  • Signs displaying lewd, illegal, or immoral matter.
  • Any sign advertising a business, product, or service, not available on the premises where the sign is located except as permitted for off-premises signs.
  • Signs identifying past services performed on a building or premises (e.g., 'Roof by ...').
  • Signs on fences, utility poles, street lights or trees.
  • Signs in public rights-of-way except where a dividing 'island' exists between two (2) sections of streets and as long as visibility is not restricted, and except for traffic signs erected by a governmental unit.
  • Signs which are confusingly similar to or imitate any official marker erected by governmental units, or which, by reason of position, shape, or color, would confuse or conflict with the proper functioning of any traffic sign or signal.
  • Signs on any property without the consent of the party having the right of present possession.
  • Signs extending over or placed upon a public sidewalk, alley, or right-of-way except as permitted in specific code sections.
  • All signs not specifically allowed by the provisions of the section.
  • Billboards except as allowed by special exception by the Board of Zoning Appeals.
  • Roof signs except as allowed by special exception by the Board of Zoning Appeals.
  • No person shall place, maintain, or display upon or in view of any highway any unauthorized sign, signal, marking or device which purports to be or is an imitation of or resembles an official traffic control device or railroad sign or signal, or hides from view or interferes with the effectiveness of any official traffic control device or any railroad sign or signal.
  • No person shall place or maintain or permit upon any highway, any traffic sign or signal bearing any commercial advertising (except as exempted for private property signs that cannot be mistaken for official signs).

Exempt Signs in Dyer

  • Temporary signs measuring twelve (12) square feet or less in gross surface area are exempt from the requirement to obtain a permit unless illuminated.
  • Permanent signs measuring twelve (12) square feet or less in gross surface area are exempt from the requirement to obtain a permit unless illuminated.
  • Temporary signs installed by a religious or charitable organization are exempt from the permit fee.
  • Signs required by law to be exhibited by the occupant of the premises, not exceeding six (6) square feet in gross surface area.
  • Signs serving the public convenience, such as 'notary public,' 'public telephone,' 'public restroom,' or similar, not exceeding seventy-two (72) square inches in total area, with only one sign of each type per building.
  • Signs on private property adjacent to highways giving useful directional information and of a type that cannot be mistaken for official signs are not prohibited.

Sign Plan & Submission Notes for Dyer

  • Shopping centers and planned unit development-commercial buildings may be allowed one (1) freestanding sign for each six (6) tenants or fractions thereof.
  • Additional or special exceptions for signs such as billboards or roof signs require approval (special exception) by the Board of Zoning Appeals.
  • Banners require a permit prior to posting, and annual banner permit fees are prorated; see town code section 7-63.
  • Permit required for each banner and portable sign; annual review for billboards by the Zoning Administrator.
  • No general requirement for a 'master sign plan' is stated in the provided text, but planned unit developments and shopping centers have specific signage allowances based on the number of tenants.