Jeffersonville, Indiana has specific sign regulations covering 51 sign types across 12 zoning districts. Regulated sign types include Temporary Wall Signs, Permanent Monument Sign, Permanent Projecting Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: January 22, 2026
Sign Regulation Overview for Jeffersonville, Indiana
Sample Sign Requirements in Jeffersonville
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Permanent Monument Sign or Post Sign (Subdivision/Residential Complex Entrances) | Monument/Post: 4 ft | Monument/Post: 32 sq ft per side | ≥15 ft from right-of-way; not in the vision clearance triangle (Sec. 7.23) |
| Permanent Wall Sign (Residential) | — | 1 sq ft | — |
| Temporary Suspended/Yard Signs (≤3 sq ft) | — | 3 sq ft | — |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
51
- Temporary Wall Signs
- Permanent Monument Sign
- Permanent Projecting Sign
- Permanent Wall Sign
- +2 more types
Zoning Districts
12
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Jeffersonville
Other Cities in Indiana
Frequently Asked Questions
In Jeffersonville, monument signs are limited to Monument/Post: 4 ft. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.
To get a sign permit in Jeffersonville, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Jeffersonville, regulated sign types include Temporary Wall Signs, Permanent Monument Sign, Permanent Projecting Sign, Permanent Wall Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
In Jeffersonville, monument signs typically require a ≥15 ft from right-of-way; not in the vision clearance triangle (Sec. 7.23) setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.
Digital and LED signs in Jeffersonville are regulated with specific requirements for brightness, animation, and message duration. Jeffersonville has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Jeffersonville Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Jeffersonville, Indiana sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Jeffersonville, Indiana Sign Rules at a Glance
Jeffersonville, Indiana regulates 51 sign types across 12 zoning districts. Permanent Monument Signs in the Neighborhood Commercial (NC), Downtown Commercial (DC) zoning district are capped at 5 ft tall and 16 sq ft per side (message area), with a ≥2 ft from right-of-way; not within vision clearance triangle setback (Sec. PS-03.A–C (7-44)). Most commercial signs in Jeffersonville require a permit.
Detailed Sign Ordinance Requirements for Jeffersonville, Indiana
Sign Rules by Zoning District in Jeffersonville (12 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Low Density Residential (R1), Medium Density Residential (R2), Old City Residential (R3) | 4 | 5 ft | Monument/Post: 32 sq ft per side | — |
| Low Density Multi-Family Residential (M1), Medium Density Multi-Family Residential (M2), High Density Multi-Family Residential (M3), Mobile Home Park (MP) | 5 | 5 ft | 40 sq ft | — |
| Neighborhood Commercial (NC), Downtown Commercial (DC) | 11 | Lowest point ≥8.5 ft above grade | 50 sq ft per sign (subject to cumulative lot cap) | — |
| Office Commercial (OC) | 11 | Lowest point ≥8.5 ft above grade | 50 sq ft per sign | — |
| Highway Commercial (HC), Small to Medium Scale General Commercial (C1), Medium to Large Scale General Commercial (C2) | 19 | 10 ft | 250 sq ft cap (per lot cumulative) | — |
| Neighborhood Industrial (NI) | 10 | Lowest point ≥8.5 ft above grade | 125 sq ft cap (per lot cumulative) | — |
| Business Park/Light Industrial (I1), Industrial Park/Heavy Industrial (I2) | 11 | 10 ft | 400 sq ft cap (per lot cumulative) | — |
| INAAP Redevelopment (IR) | 8 | 10 ft | 400 sq ft cap (per lot cumulative) | — |
| Parks and Recreation (PR), Institutional Use (IS) | 11 | Lowest point ≥8.5 ft above grade | 125 sq ft cumulative per lot | — |
| Jefferson Ridge Planned Development (Planning Area 1) | 6 | 20 ft (total side pillar height) | No individual sign >200 sq ft | — |
| Jefferson Ridge Planned Development (Planning Area 2) | 5 | Primary: 20 ft; Secondary: 10 ft | No individual sign >200 sq ft | — |
| General Regulations For All Zones | 2 | — | Brightness limits: ≤700 nits from 30 minutes before sunset to 30 minutes after sunrise; ≤10,000 nits at all other times | — |
Zone-by-Zone Sign Requirements in Jeffersonville(sample of 3 of 12 zones)
Neighborhood Commercial (NC), Downtown Commercial (DC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Permanent Monument Sign | 5 ft | 16 sq ft per side (message area) | — | ≥2 ft from right-of-way; not within vision clearance triangle | One ground sign per lot | On lot; ≥2 ft from right-of-way; not within vision clearance triangle | — | Unlock | PS-03.A–C (7-44) |
| Permanent Post Sign | 5 ft | 16 sq ft per side | — | ≥2 ft from right-of-way | One ground sign per lot | On lot; ≥2 ft from right-of-way; not within vision clearance triangle | — | Unlock | PS-03.D (7-44) |
| Permanent Suspended Sign | Sign height ≤4 ft; bottom of sign ≤30 inches above ground | 4 sq ft per side | — | ≥2 ft from right-of-way | One ground sign per lot | On lot; ≥2 ft from right-of-way | — | Unlock | PS-03.F (7-45) |
| Permanent Projecting Sign | Lowest point ≥8.5 ft above grade | 12 sq ft per side | Projection ≤4 ft beyond supporting structure | — | No numeric limit (subject to cumulative area cap) | On primary structure; may extend into right-of-way only with Board of Public Works permission | — | Unlock | PS-03.E (7-45) |
| Permanent Wall Sign | — | 50 sq ft per sign (subject to cumulative lot cap) | — | — | No numeric limit (subject to cumulative area cap) | On primary structure | — | Unlock | PS-03.G (7-45) |
| Temporary Ground/Post/Suspended/Yard Signs | — | 32 sq ft | — | ≥10 ft from any property line | 2 per street frontage | On private property; ≥10 ft from any property line; not in vision clearance triangle | — | Unlock | TS-03.A (7-39) |
| Temporary Portable Signs (e.g., Sandwich Board) | 4 ft | 12 sq ft | — | — | 1 per street frontage (subject to multi-tenant determination) | Placed so as not to block public right-of-way; not within vision clearance triangle | — | Unlock | TS-03.C (7-39) |
| Temporary Portable EVMS (Not permitted in NC/DC) | 6 ft (general standard) | Up to 32 sq ft; 6 ft height (general standard) | — | ≥10 ft from any property line (general) | One per street frontage (general) | Generally ≥10 ft from any property line; not within vision clearance triangle | — | Unlock | TS-03.D (7-39) and GS 7.17.F.e |
Office Commercial (OC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Permanent Monument Sign | 8 ft | 48 sq ft per side (message area) | — | ≥10 ft from right-of-way; not within vision clearance triangle | Single-tenant: 1 ground sign; Multi-tenant: 1 per 400 ft building frontage | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | — | Unlock | PS-04.C & A (7-46) |
| Permanent Post Sign | 5 ft | 16 sq ft per side | — | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | — | Unlock | PS-04.D & A (7-46) |
| Permanent Suspended Sign | Sign height ≤4 ft; bottom of sign ≤30 inches | 4 sq ft per side | — | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way | — | Unlock | PS-04.F & A (7-47) |
| Permanent Projecting Sign | Lowest point ≥8.5 ft above grade | 12 sq ft per side | Projection ≤4 ft | — | No numeric limit | On primary structure; may extend into right-of-way only with Board of Public Works permission | — | Unlock | PS-04.E (7-46) |
| Permanent Wall Sign | — | 50 sq ft per sign | — | — | No numeric limit (subject to cumulative area cap) | On primary structure | — | Unlock | PS-04.G & A (7-47) |
| Temporary Ground/Post/Suspended/Yard Signs | — | 32 sq ft | — | ≥10 ft from any property line | 2 per street frontage | On private property; ≥10 ft from any property line; not within vision clearance triangle | — | Unlock | TS-03.A (7-39) |
| Temporary Portable Signs (e.g., Sandwich Board) | 4 ft | 12 sq ft | — | — | 1 per street frontage | Must not block public right-of-way; not within vision clearance triangle | — | Unlock | TS-03.C (7-39) |
| Temporary Portable EVMS (Not permitted in OC) | 6 ft | 32 sq ft | — | ≥10 ft from property line | 1 per street frontage | ≥10 ft from any property line; not within vision clearance triangle | — | Unlock | TS-03.D (7-39) and GS 7.17.F.e |
Highway Commercial (HC), Small to Medium Scale General Commercial (C1), Medium to Large Scale General Commercial (C2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Permanent Monument Sign (Single-tenant) - PS-04 | 8 ft | 48 sq ft per side (message area) | — | ≥10 ft from right-of-way | 1 per lot (single-tenant) | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | — | Unlock | PS-04.C (7-46) |
| Permanent Monument Sign (Single-tenant) - SSP-04 Variant | 8 ft | 56 sq ft per side (message area) | — | ≥10 ft from right-of-way | 1 per lot (single-tenant) | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | — | Unlock | SSP-04.C.1.a (7-49–7-50) |
| Permanent Monument Sign (Large Multi-tenant or group >400' frontage) - SSP-04 Variant | 10 ft | Up to 110 sq ft message area | — | ≥10 ft from right-of-way | See freestanding sign limitation (one per 400 ft building length) | On lot(s) with >400 ft of road frontage under same ownership; ≥10 ft from right-of-way; not in vision clearance triangle | — | Unlock | SSP-04.C.1.b and SSP-04.A.1.c (7-49–7-50) |
| Permanent Post Sign - PS-04 | 5 ft | 16 sq ft per side | — | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | — | Unlock | PS-04.D (7-46) |
| Permanent Post Sign - SSP-04 Variant | 6 ft | 32 sq ft per side | — | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | — | Unlock | SSP-04.D (7-49) |
| Permanent Suspended Sign - PS-04 | Sign height ≤4 ft; bottom of sign ≤30 inches | 4 sq ft per side | — | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way | — | Unlock | PS-04.F (7-47) |
| Permanent Suspended Sign - SSP-04 Variant | 5 ft | 16 sq ft per side | — | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way | — | Unlock | SSP-04.F (7-50) |
| Permanent Projecting Sign - PS-04 | Lowest point ≥8.5 ft above grade | 12 sq ft per side | Projection ≤4 ft | — | No numeric limit | On primary structure; ROW extension requires Board of Public Works permission | — | Unlock | PS-04.E (7-46) |
PermitPal covers all 12 zoning districts in Jeffersonville — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 12 zones for Jeffersonville — start freeProhibited Signs in Jeffersonville
- It is unlawful to erect, construct, enlarge, move, convert, or change the permanent copy on any sign without first obtaining a Sign Permit, except as otherwise provided (GS-01.A).
- Signs that utilize any motion picture, laser, or visual projection of images or copy in conjunction with any business or advertisement are prohibited in all zoning districts (GS-01.I.a).
- Signs that emit audible sound, odor, or visible matter are prohibited in all zoning districts (GS-01.I.b).
- Signs that imitate or resemble an official traffic sign or signal, or that bear words such as 'Stop', 'Slow', 'Caution', 'Danger', 'Warning', or similar are prohibited in all zoning districts (GS-01.I.c).
- Signs that may be construed as a light of an emergency or road equipment vehicle are prohibited in all zoning districts (GS-01.I.d).
- Signs located in the public right-of-way or that hide from view any traffic or roadway sign, signal, or device are prohibited in all zoning districts (GS-01.I.e).
- Signs that interfere with the vision clearance triangle are prohibited in all zoning districts (GS-01.I.f).
- Signs that extend above the roof line or parapet of a building are prohibited in all zoning districts (GS-01.I.g).
- Roof signs are prohibited in all zoning districts (GS-01.I.h).
- Signs that have blinking, flashing, or fluttering lights, or that have changing light intensity, brightness, or color, or give such illusion, are prohibited in all zoning districts (GS-01.I.i).
- Signs that obstruct any door, fire escape, stairway, or any opening intended to provide entrance or exit for any building or structure are prohibited in all zoning districts (GS-01.I.j).
- Signs placed on vehicles parked on public or private property primarily for the purpose of displaying the sign are prohibited in all zoning districts, with exceptions for normal deliveries, customary transportation, or incidental parking at a residence (GS-01.I.k).
- Billboards are prohibited in all zoning districts (GS-01.I.l).
- Inflatable animated or moving signs are prohibited in all zoning districts (GS-01.I.m).
- All other attention-seeking signs are prohibited in all zoning districts (GS-01.I.n).
- Any sign not expressly permitted by the ordinance is prohibited (GS-01.I.o).
- Illuminated signs shall not create a traffic hazard due to direct or reflected light (GS-01.G.d).
- Illuminated signs must be shaded, shielded, or directed so light is not objectionable to surrounding properties; no light shall shine directly onto adjacent property (GS-01.G.e).
Exempt Signs in Jeffersonville
- Posting of a street address for property identification (may be required to comply if used as a commercial message or unnecessarily large at the Planning Director’s discretion) (GS-01.H.a).
- Flags of any country, state, unit of local government, institution of higher learning, or similar institutional flags (GS-01.H.b).
- Names of buildings, date of erection, monumental citations, and commemorative tablets when carved into stone, concrete, or similar material, or made of bronze, aluminum, or other permanent materials, with no commercial messages or logos (GS-01.H.c).
- Public signs of a non-commercial nature and in the public interest erected by or on the order of public officers in the performance of public duty (e.g., safety, no trespassing, traffic signs, memorial plaques, historical interest, and directional signs to public/quasi-public facilities) (GS-01.H.d).
- Utility signs used to mark cables and lines for public and private utilities, except if determined to be a hazard by the Plan Commission (GS-01.H.e).
- Political signs in accordance with IC 36-1-3-11 (GS-01.H.f).
Sign Plan & Submission Notes for Jeffersonville
- Planned Development (PD) applications must include proposals and plans for signage as part of the Conceptual Site Plan and Detailed Development Plan submissions (Article 8.8.B.e).
- The Jefferson Ridge PD includes an Appendix 2 'Sign Plan' that is a conceptual sign plan illustrating signature entrance signs and site signs; it is illustrative and signage will be permitted in accordance with the PD signage guidelines (Appendix 2).
- Within the Jefferson Ridge PD, changes to or deviations from the PD Sign Standards must be approved by the Planning Commission or their designee (Sign Standards section).
- Projecting signs that extend into the public right-of-way require permission from the Board of Public Works (applies wherever projecting signs are allowed) (e.g., PS-02.E.d(3); PS-03.E; PS-04.E; PS-06.E).
- No citywide 'Master Sign Plan' requirement is stated in the provided text outside of PD submittals; sign plans are explicitly required as part of PD review packages.
Source: other municipal code