Jeffersonville, Indiana has specific sign regulations covering 51 sign types across 12 zoning districts. Regulated sign types include Temporary Wall Signs, Permanent Monument Sign, Permanent Projecting Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: January 22, 2026
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Jeffersonville, Indiana
Sample Sign Requirements in Jeffersonville
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Permanent Monument Sign or Post Sign (Subdivision/Residential Complex Entrances) | Monument/Post: 4 ft | Monument/Post: 32 sq ft per side | ≥15 ft from right-of-way; not in the vision clearance triangle (Sec. 7.23) |
| Permanent Wall Sign (Residential) | Not listed | 1 sq ft | Not listed |
| Temporary Suspended/Yard Signs (≤3 sq ft) | Not listed | 3 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
51
- Temporary Wall Signs
- Permanent Monument Sign
- Permanent Projecting Sign
- Permanent Wall Sign
- +2 more types
Zoning Districts
12
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Jeffersonville
Other Cities in Indiana
Frequently Asked Questions
In Jeffersonville, the height limit for Permanent Monument Sign (Large Multi-tenant or group >400' frontage) - SSP-04 Variant in the Highway Commercial (HC) and other zoning districts is 10 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Jeffersonville require a permit. From the submission notes on this page: Planned Development (PD) applications must include proposals and plans for signage as part of the Conceptual Site Plan and Detailed Development Plan submissions (Article 8.8.B.e). Run a code check for an exact address to see the permit requirements for that zone.
Jeffersonville's sign code covers 51 sign types, including Temporary Wall Signs, Permanent Monument Sign, Permanent Projecting Sign, and Permanent Wall Sign. Most commercial signs need a permit. The ordinance lists 6 exemptions. One of them: Political signs in accordance with IC 36-1-3-11 (GS-01.H.f). The full list is on this page.
In Jeffersonville, Temporary Ground/Post/Suspended/Yard Signs in the Neighborhood Commercial (NC), Downtown Commercial (DC) zoning districts must be set back at least 10 ft from any property line. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Jeffersonville's sign ordinance that cover digital, changing, or flashing signs: Signs that have blinking, flashing, or fluttering lights, or that have changing light intensity, brightness, or color, or give such illusion, are prohibited in all zoning districts (GS-01.I.i). Inflatable animated or moving signs are prohibited in all zoning districts (GS-01.I.m). Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Jeffersonville Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Jeffersonville, Indiana, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Jeffersonville, Indiana Sign Rules at a Glance
Jeffersonville, Indiana regulates 51 sign types across 12 zoning districts. Permanent Post Signs in the Office Commercial (OC) zoning district are capped at 5 ft tall and 16 sq ft per side, set back at least 10 ft from right-of-way. Most commercial signs in Jeffersonville require a permit.
Detailed Sign Ordinance Requirements for Jeffersonville, Indiana
Sign Rules by Zoning District in Jeffersonville (12 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Low Density Residential (R1), Medium Density Residential (R2), Old City Residential (R3) | 4 | 5 ft | Monument/Post: 32 sq ft per side | Not listed |
| Low Density Multi-Family Residential (M1), Medium Density Multi-Family Residential (M2), High Density Multi-Family Residential (M3), Mobile Home Park (MP) | 5 | 5 ft | 40 sq ft | Not listed |
| Neighborhood Commercial (NC), Downtown Commercial (DC) | 11 | Lowest point ≥8.5 ft above grade | 50 sq ft per sign (subject to cumulative lot cap) | Not listed |
| Office Commercial (OC) | 11 | Lowest point ≥8.5 ft above grade | 50 sq ft per sign | Not listed |
| Highway Commercial (HC), Small to Medium Scale General Commercial (C1), Medium to Large Scale General Commercial (C2) | 19 | 10 ft | 250 sq ft cap (per lot cumulative) | Not listed |
| Neighborhood Industrial (NI) | 10 | Lowest point ≥8.5 ft above grade | 125 sq ft cap (per lot cumulative) | Not listed |
| Business Park/Light Industrial (I1), Industrial Park/Heavy Industrial (I2) | 11 | 10 ft | 400 sq ft cap (per lot cumulative) | Not listed |
| INAAP Redevelopment (IR) | 8 | 10 ft | 400 sq ft cap (per lot cumulative) | Not listed |
| Parks and Recreation (PR), Institutional Use (IS) | 11 | Lowest point ≥8.5 ft above grade | 125 sq ft cumulative per lot | Not listed |
| Jefferson Ridge Planned Development (Planning Area 1) | 6 | 20 ft (total side pillar height) | No individual sign >200 sq ft | Not listed |
| Jefferson Ridge Planned Development (Planning Area 2) | 5 | Primary: 20 ft; Secondary: 10 ft | No individual sign >200 sq ft | Not listed |
| General Regulations For All Zones | 2 | Not listed | Brightness limits: ≤700 nits from 30 minutes before sunset to 30 minutes after sunrise; ≤10,000 nits at all other times | Not listed |
Zone-by-Zone Sign Requirements in Jeffersonville(sample of 3 of 12 zones)
Neighborhood Commercial (NC), Downtown Commercial (DC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Permanent Monument Sign | 5 ft | 16 sq ft per side (message area) | Not listed | ≥2 ft from right-of-way; not within vision clearance triangle | One ground sign per lot | On lot; ≥2 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | PS-03.A–C (7-44) |
| Permanent Post Sign | 5 ft | 16 sq ft per side | Not listed | ≥2 ft from right-of-way | One ground sign per lot | On lot; ≥2 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | PS-03.D (7-44) |
| Permanent Suspended Sign | Sign height ≤4 ft; bottom of sign ≤30 inches above ground | 4 sq ft per side | Not listed | ≥2 ft from right-of-way | One ground sign per lot | On lot; ≥2 ft from right-of-way | Not listed | Unlock | PS-03.F (7-45) |
| Permanent Projecting Sign | Lowest point ≥8.5 ft above grade | 12 sq ft per side | Projection ≤4 ft beyond supporting structure | Not listed | No numeric limit (subject to cumulative area cap) | On primary structure; may extend into right-of-way only with Board of Public Works permission | Not listed | Unlock | PS-03.E (7-45) |
| Permanent Wall Sign | Not listed | 50 sq ft per sign (subject to cumulative lot cap) | Not listed | Not listed | No numeric limit (subject to cumulative area cap) | On primary structure | Not listed | Unlock | PS-03.G (7-45) |
| Temporary Ground/Post/Suspended/Yard Signs | Not listed | 32 sq ft | Not listed | ≥10 ft from any property line | 2 per street frontage | On private property; ≥10 ft from any property line; not in vision clearance triangle | Not listed | Unlock | TS-03.A (7-39) |
| Temporary Portable Signs (e.g., Sandwich Board) | 4 ft | 12 sq ft | Not listed | Not listed | 1 per street frontage (subject to multi-tenant determination) | Placed so as not to block public right-of-way; not within vision clearance triangle | Not listed | Unlock | TS-03.C (7-39) |
| Temporary Portable EVMS (Not permitted in NC/DC) | 6 ft (general standard) | Up to 32 sq ft; 6 ft height (general standard) | Not listed | ≥10 ft from any property line (general) | One per street frontage (general) | Generally ≥10 ft from any property line; not within vision clearance triangle | Not listed | Unlock | TS-03.D (7-39) and GS 7.17.F.e |
Office Commercial (OC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Permanent Monument Sign | 8 ft | 48 sq ft per side (message area) | Not listed | ≥10 ft from right-of-way; not within vision clearance triangle | Single-tenant: 1 ground sign; Multi-tenant: 1 per 400 ft building frontage | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | PS-04.C & A (7-46) |
| Permanent Post Sign | 5 ft | 16 sq ft per side | Not listed | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | PS-04.D & A (7-46) |
| Permanent Suspended Sign | Sign height ≤4 ft; bottom of sign ≤30 inches | 4 sq ft per side | Not listed | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way | Not listed | Unlock | PS-04.F & A (7-47) |
| Permanent Projecting Sign | Lowest point ≥8.5 ft above grade | 12 sq ft per side | Projection ≤4 ft | Not listed | No numeric limit | On primary structure; may extend into right-of-way only with Board of Public Works permission | Not listed | Unlock | PS-04.E (7-46) |
| Permanent Wall Sign | Not listed | 50 sq ft per sign | Not listed | Not listed | No numeric limit (subject to cumulative area cap) | On primary structure | Not listed | Unlock | PS-04.G & A (7-47) |
| Temporary Ground/Post/Suspended/Yard Signs | Not listed | 32 sq ft | Not listed | ≥10 ft from any property line | 2 per street frontage | On private property; ≥10 ft from any property line; not within vision clearance triangle | Not listed | Unlock | TS-03.A (7-39) |
| Temporary Portable Signs (e.g., Sandwich Board) | 4 ft | 12 sq ft | Not listed | Not listed | 1 per street frontage | Must not block public right-of-way; not within vision clearance triangle | Not listed | Unlock | TS-03.C (7-39) |
| Temporary Portable EVMS (Not permitted in OC) | 6 ft | 32 sq ft | Not listed | ≥10 ft from property line | 1 per street frontage | ≥10 ft from any property line; not within vision clearance triangle | Not listed | Unlock | TS-03.D (7-39) and GS 7.17.F.e |
Highway Commercial (HC), Small to Medium Scale General Commercial (C1), Medium to Large Scale General Commercial (C2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Permanent Monument Sign (Single-tenant) - PS-04 | 8 ft | 48 sq ft per side (message area) | Not listed | ≥10 ft from right-of-way | 1 per lot (single-tenant) | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | PS-04.C (7-46) |
| Permanent Monument Sign (Single-tenant) - SSP-04 Variant | 8 ft | 56 sq ft per side (message area) | Not listed | ≥10 ft from right-of-way | 1 per lot (single-tenant) | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | SSP-04.C.1.a (7-49–7-50) |
| Permanent Monument Sign (Large Multi-tenant or group >400' frontage) - SSP-04 Variant | 10 ft | Up to 110 sq ft message area | Not listed | ≥10 ft from right-of-way | See freestanding sign limitation (one per 400 ft building length) | On lot(s) with >400 ft of road frontage under same ownership; ≥10 ft from right-of-way; not in vision clearance triangle | Not listed | Unlock | SSP-04.C.1.b and SSP-04.A.1.c (7-49–7-50) |
| Permanent Post Sign - PS-04 | 5 ft | 16 sq ft per side | Not listed | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | PS-04.D (7-46) |
| Permanent Post Sign - SSP-04 Variant | 6 ft | 32 sq ft per side | Not listed | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way; not within vision clearance triangle | Not listed | Unlock | SSP-04.D (7-49) |
| Permanent Suspended Sign - PS-04 | Sign height ≤4 ft; bottom of sign ≤30 inches | 4 sq ft per side | Not listed | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way | Not listed | Unlock | PS-04.F (7-47) |
| Permanent Suspended Sign - SSP-04 Variant | 5 ft | 16 sq ft per side | Not listed | ≥10 ft from right-of-way | As limited by ground sign rules | On lot; ≥10 ft from right-of-way | Not listed | Unlock | SSP-04.F (7-50) |
| Permanent Projecting Sign - PS-04 | Lowest point ≥8.5 ft above grade | 12 sq ft per side | Projection ≤4 ft | Not listed | No numeric limit | On primary structure; ROW extension requires Board of Public Works permission | Not listed | Unlock | PS-04.E (7-46) |
PermitPal covers all 12 zoning districts in Jeffersonville. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Jeffersonville
- It is unlawful to erect, construct, enlarge, move, convert, or change the permanent copy on any sign without first obtaining a Sign Permit, except as otherwise provided (GS-01.A).
- Signs that utilize any motion picture, laser, or visual projection of images or copy in conjunction with any business or advertisement are prohibited in all zoning districts (GS-01.I.a).
- Signs that emit audible sound, odor, or visible matter are prohibited in all zoning districts (GS-01.I.b).
- Signs that imitate or resemble an official traffic sign or signal, or that bear words such as 'Stop', 'Slow', 'Caution', 'Danger', 'Warning', or similar are prohibited in all zoning districts (GS-01.I.c).
- Signs that may be construed as a light of an emergency or road equipment vehicle are prohibited in all zoning districts (GS-01.I.d).
- Signs located in the public right-of-way or that hide from view any traffic or roadway sign, signal, or device are prohibited in all zoning districts (GS-01.I.e).
- Signs that interfere with the vision clearance triangle are prohibited in all zoning districts (GS-01.I.f).
- Signs that extend above the roof line or parapet of a building are prohibited in all zoning districts (GS-01.I.g).
- Roof signs are prohibited in all zoning districts (GS-01.I.h).
- Signs that have blinking, flashing, or fluttering lights, or that have changing light intensity, brightness, or color, or give such illusion, are prohibited in all zoning districts (GS-01.I.i).
- Signs that obstruct any door, fire escape, stairway, or any opening intended to provide entrance or exit for any building or structure are prohibited in all zoning districts (GS-01.I.j).
- Signs placed on vehicles parked on public or private property primarily for the purpose of displaying the sign are prohibited in all zoning districts, with exceptions for normal deliveries, customary transportation, or incidental parking at a residence (GS-01.I.k).
- Billboards are prohibited in all zoning districts (GS-01.I.l).
- Inflatable animated or moving signs are prohibited in all zoning districts (GS-01.I.m).
- All other attention-seeking signs are prohibited in all zoning districts (GS-01.I.n).
- Any sign not expressly permitted by the ordinance is prohibited (GS-01.I.o).
- Illuminated signs shall not create a traffic hazard due to direct or reflected light (GS-01.G.d).
- Illuminated signs must be shaded, shielded, or directed so light is not objectionable to surrounding properties; no light shall shine directly onto adjacent property (GS-01.G.e).
Exempt Signs in Jeffersonville
- Posting of a street address for property identification (may be required to comply if used as a commercial message or unnecessarily large at the Planning Director’s discretion) (GS-01.H.a).
- Flags of any country, state, unit of local government, institution of higher learning, or similar institutional flags (GS-01.H.b).
- Names of buildings, date of erection, monumental citations, and commemorative tablets when carved into stone, concrete, or similar material, or made of bronze, aluminum, or other permanent materials, with no commercial messages or logos (GS-01.H.c).
- Public signs of a non-commercial nature and in the public interest erected by or on the order of public officers in the performance of public duty (e.g., safety, no trespassing, traffic signs, memorial plaques, historical interest, and directional signs to public/quasi-public facilities) (GS-01.H.d).
- Utility signs used to mark cables and lines for public and private utilities, except if determined to be a hazard by the Plan Commission (GS-01.H.e).
- Political signs in accordance with IC 36-1-3-11 (GS-01.H.f).
Sign Plan & Submission Notes for Jeffersonville
- Planned Development (PD) applications must include proposals and plans for signage as part of the Conceptual Site Plan and Detailed Development Plan submissions (Article 8.8.B.e).
- The Jefferson Ridge PD includes an Appendix 2 'Sign Plan' that is a conceptual sign plan illustrating signature entrance signs and site signs; it is illustrative and signage will be permitted in accordance with the PD signage guidelines (Appendix 2).
- Within the Jefferson Ridge PD, changes to or deviations from the PD Sign Standards must be approved by the Planning Commission or their designee (Sign Standards section).
- Projecting signs that extend into the public right-of-way require permission from the Board of Public Works (applies wherever projecting signs are allowed) (e.g., PS-02.E.d(3); PS-03.E; PS-04.E; PS-06.E).
- No citywide 'Master Sign Plan' requirement is stated in the provided text outside of PD submittals; sign plans are explicitly required as part of PD review packages.