Questions? Call us at (262) 218-2915

Sign Regulations in Baltimore, Maryland

Baltimore, Maryland has specific sign regulations covering 174 sign types across 33 zoning districts. Regulated sign types include A-frame, Provisional Fence Sign, Painted / Mural Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: January 26, 2026

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Baltimore, Maryland

Sample Sign Requirements in Baltimore

Sign TypeMax HeightMax AreaSetback
A-frame Sign4 ft (where allowed by Table 17-201).8 sq. ft. per side (where allowed by Table 17-201).Not listed
Attention-getting DeviceInflatable promotional devices: max. 15 ft or height of principal building, whichever is lower. (§ 17-403(b)(5)).Not listedNot listed
Awning or Canopy Sign & Open-Structural Framework SignSigns on awnings/canopies themselves max. 2 ft tall; awning/canopy must maintain at least 8 ft vertical clearance from ground and be at least 1 ft from curb line. Signs under awning/canopy must maintain at least 8 ft clearance (§ 17‑404(b)(1)-(3),(7)).By district, typically 2 sq. ft per linear foot of awning/canopy/frame width (see Table 17-201 for each zone).Awning/canopy at least 1 ft from curb line (§ 17‑404(b)(2)).

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for BaltimoreFull Coverage

Sign Types Covered

174

  • A-frame
  • Provisional Fence Sign
  • Painted / Mural Sign
  • Awning or Canopy Sign & Open-Structural Framework Sign
  • +2 more types

Zoning Districts

33

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Baltimore

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Baltimore, the height limit for A-frame Sign is 4 ft (where allowed by Table 17-201). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Baltimore require a permit. From the submission notes on this page: Once an area is designated as an Area of Special Signage Control, a Signage Plan is required and must be submitted to the Planning Commission before any signs may be erected in that area. (§17-504(a), §17-505(a)). Run a code check for an exact address to see the permit requirements for that zone.

Baltimore's sign code covers 174 sign types, including A-frame, Provisional Fence Sign, Painted / Mural Sign, and Awning or Canopy Sign & Open-Structural Framework Sign. Most commercial signs need a permit. The ordinance lists 11 exemptions. One of them: Non-obscene wording and non-obscene graphics on table umbrellas are not governed by Title 17. (§17-201(c)). The full list is on this page.

This page doesn't list a single setback distance for signs in Baltimore. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.

Rules in Baltimore's sign ordinance that cover digital, changing, or flashing signs: Except as otherwise specifically provided, the erection, conversion, placement, or construction of new billboards, static or digital, is prohibited. (§17-406(a)(1)). No sign may have or consist of any moving, rotating, or animated part or any flashing, blinking, fluctuating, or animated light, except on electronic signs and barber poles or similar rotating graphics. (§17-410). No electronic sign affixed to a building, including its support structure, may project beyond the ends or top of the wall or higher than any roofline of the structure to which it is attached. (§17-407(g)(1)). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Baltimore Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Baltimore, Maryland, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Baltimore, Maryland Sign Rules at a Glance

Baltimore, Maryland regulates 174 sign types across 33 zoning districts. A-Frames in the C-5-DC zoning district are capped at 8 sq ft per side. Most commercial signs in Baltimore require a permit.

Detailed Sign Ordinance Requirements for Baltimore, Maryland

Sign Rules by Zoning District in Baltimore (33 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones18May not project higher than the height of the facade to which attached (§ 17‑414(c)(2)).New non‑digital billboards max 50 sq. ft (§ 17‑406(c)(2)(i)). Digital billboard sizes not stated in sq. ft in base text, but limited by signage plan; conversion requires each removed printed face to be ≥100 sq. ft (§ 17‑406(d)(1)(vii)).Not listed
Open-Space Zoning District (OS)1220 ft maximum sign height; minimum height 6 ft; maximum width 6 ft (§ Table 17‑201 OS row for ‘Freestanding (Pylon)’).100 sq. ft per sign in OS.Not listed
Floodplain Overlay Zoning District (FP)1Not listedNot listedNot listed
Chesapeake Bay Critical Area Overlay Zoning District (CBCA)1Not listedNot listedNot listed
Detached Residential Zoning District (R-1A, R-1B, R-1C, R-1D, R-1E, R-1, R-3) (R-1A through R-4)512 ft max.36 sq. ft per sign.Not listed
Detached and Semi-Detached Residential Zoning District (R-2, R-4) (R-5 through R-7)812 ft max.36 sq. ft.Not listed
Rowhouse and Multi-Family Residential Zoning District (R-5, R-6, R-7, R-8, R-9, R-10) (R-8 through R-10)912 ft max.36 sq. ft.Not listed
Rowhouse Mixed-Use Overlay District (R-MU)712 ft max.32 sq. ft.Not listed
Detached Dwelling Mixed-Use Overlay District (D-MU)512 ft max.32 sq. ft.Not listed
Neighborhood Business Zoning District (C-1, C-1-VC) (C-1, C-1-E, C-1-VC)136 ft max height.New non‑digital billboards max 50 sq. ft (§ 17‑406(c)(2)(i)).Not listed
Community Commercial Zoning District (C-2)1312 ft.40 sq. ft per sign.Not listed
General Commercial Zoning District (C-3)1412 ft.100 sq. ft per sign.Not listed
Heavy Commercial Zoning District (C-4)1412 ft.100 sq. ft; 1 per lot.Not listed
C-5-DC23May not project higher than 20 ft. above the roof10,5000 sq. ft. (table text)Not listed
C-5-IH20May not project any higher than 20 ft. above the roof750 sq. ft.Not listed
C-5-DE20May not project any higher than 20 ft. above the roof750 sq. ft.Not listed
C-5-HT19May not project any higher than 20 ft. above the roof120 sq. ft.Not listed
C-5-TO21May not project any higher than 20 ft. above the roof5,000 sq. ft.Not listed
C-5-HS19May not project any higher than 15 ft. above the roof400 sq. ft.Not listed
C-5-G20May not project any higher than 20 ft. above the roof750 sq. ft.Not listed
Office-Industrial Campus Zoning District (OIC)912 ft.Monument: 100 sq. ft; Pole: 50 sq. ft; Pylon: 50 sq. ft.Not listed
Bio-Science Campus Zoning District (BSC)1112 ft.60 sq. ft; 1 per lot.Not listed
Industrial Mixed-Use Zoning District (IMU-1, IMU-2) (IMU-1, IMU-2)12Pole: 24 ft sign height, 10 ft min pole; Pylon: 20 ft sign height, width 6 ft.50 sq. ft per sign.Not listed
Light Industrial Zoning District (I-1)624 ft sign height; 10 ft min pole height.50 sq. ft; 1 per lot.Not listed
General Industrial Zoning District (I-2)7May not project more than 20 ft above roof.50 sq. ft; 1 per lot.Not listed
Maritime Industrial Zoning District (MI)7May not project more than 20 ft above roof.50 sq. ft; 2 per lot.Not listed
Office-Residential Zoning District (OR-1, OR-2) (OR-1, OR-2)1412 ft.40 sq. ft; 1 per lot.Not listed
Educational Campus Zoning District (EC-1, EC-2)912 ft.Monument: 100 sq. ft; Pole: 32 sq. ft; Pylon: 50 sq. ft.Not listed
Hospital Campus Zoning District (H)1Not listedNot listedNot listed
Transit-Oriented Development District (TOD-1, TOD-2, TOD-3, TOD-4)1Not listedNot listedNot listed
Start free to see 3 more zones

Zone-by-Zone Sign Requirements in Baltimore(sample of 3 of 33 zones)

C-5-DC

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
A-FrameMax. height 4 ft.8 sq. ft. per sideNot listedNot listed1 per tenant w/ direct ground-floor access / corner tenant, 1 per street frontageNot listedNot listedUnlockTable: Sign Types by Zoning District – C-5-DC – A-Frame.
Awning or Canopy Sign & Open-Structural Framework SignNot listed2 sq. ft. per linear foot of awning, canopy, or frame widthNot listedNot listed2 per lotOn awning, canopy, or open structural frameworkNot listedUnlockTable: Sign Types by Zoning District – C-5-DC – Awning or Canopy Sign & Open-Structural Framework Sign.
Banner Sign (Freestanding)Max. height 6 ft., except flags on single pole max. height 25 ft.32 sq. ft.Not listedNot listed1 per lotFreestandingNot listedUnlockTable: Sign Types by Zoning District – C-5-DC – Banner Sign (Freestanding).
Banner Sign (Projecting)Not listed32 sq. ft.Not listedNot listed4 per lotProjecting from buildingNot listedUnlockTable: Sign Types by Zoning District – C-5-DC – Banner Sign (Projecting).
Freestanding Sign (Monument)Max. height 6 ft.50 sq. ft.Not listedNot listed1 per lotFreestanding monumentNot listedUnlockTable: Sign Types by Zoning District – C-5-DC – Freestanding (Monument).
Freestanding Sign (Pole)Min. height 10 ft.; max. height 75 ft. in a parking lot less than 2,000 ft. from a stadium with a seating capacity of at least 40,000700 sq. ft.Not listedNot listed1 per lotFreestanding pole sign in a parking lot less than 2,000 ft. from a stadium (≥40,000 seats)Not listedUnlockTable: Sign Types by Zoning District – C-5-DC – Freestanding (Pole).
Freestanding Sign (Pylon)Minimum height 6 ft.; maximum sign height 20 ft.50 sq. ft.Max. width 6 ft.Not listed1 per lotFreestanding pylon signNot listedUnlockTable: Sign Types by Zoning District – C-5-DC – Freestanding (Pylon).
Roof SignMay not project higher than 20 ft. above the roof4 sq. ft. per linear foot of building frontageNot listedNot listed1 per buildingOn the roof of the buildingNot listedUnlockTable: Sign Types by Zoning District – C-5-DC – Roof Sign.

C-5-IH

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
A-FrameMax. height 4 ft.8 sq. ft. per sideNot listedNot listed1 per tenant w/ direct ground-floor access / corner tenant, 1 per street frontageNot listedNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – A-Frame.
Awning or Canopy Sign & Open-Structural Framework SignNot listed2 sq. ft. per linear foot of awning, canopy, or frame widthNot listedNot listed2 per lotOn awning, canopy, or open structural frameworkNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – Awning or Canopy Sign & Open-Structural Framework Sign.
Banner Sign (Freestanding)Max. height 6 ft., except flags on single pole max. height 25 ft.32 sq. ft.Not listedNot listed1 per lotFreestandingNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – Banner Sign (Freestanding).
Banner Sign (Projecting)Not listed32 sq. ft.Not listedNot listed4 per lotProjecting from buildingNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – Banner Sign (Projecting).
Banner Sign (Wall Mounted)Not listed120 sq. ft.Not listedNot listed2 per lotWall mounted below parapetNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – Banner Sign (Wall Mounted).
Freestanding Sign (Monument)Max. height 6 ft.50 sq. ft.Not listedNot listed1 per lotFreestanding monumentNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – Freestanding (Monument).
Freestanding Sign (Pylon)Minimum height 6 ft.; maximum sign height 20 ft.50 sq. ft.Max. width 6 ft.Not listed1 per lotFreestanding pylon signNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – Freestanding (Pylon).
Roof SignMay not project any higher than 20 ft. above the roof4 sq. ft. per linear foot of building frontageNot listedNot listed1 per buildingOn roof of buildingNot listedUnlockTable: Sign Types by Zoning District – C-5-IH – Roof Sign.

C-5-TO

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
A-FrameMax. height 4 ft.8 sq. ft. per sideNot listedNot listed1 per tenant w/ direct ground-floor access / corner tenant, 1 per street frontageNot listedNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – A-Frame.
Awning or Canopy Sign & Open-Structural Framework SignNot listed2 sq. ft. per linear foot of awning, canopy, or frame widthNot listedNot listed2 per lotOn awning, canopy, or open structural frameworkNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – Awning or Canopy Sign & Open-Structural Framework Sign.
Banner Sign (Freestanding)Max. height 6 ft., except flags on single pole max. height 25 ft.32 sq. ft.Not listedNot listed1 per lotFreestandingNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – Banner Sign (Freestanding).
Banner Sign (Projecting)Not listed50 sq. ft.Not listedNot listed4 per lotProjecting from buildingNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – Banner Sign (Projecting).
Banner Sign (Wall Mounted)Not listed120 sq. ft.Not listedNot listed1 per lotWall mounted below parapetNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – Banner Sign (Wall Mounted).
Freestanding Sign (Monument)Max. height 6 ft.50 sq. ft.Not listedNot listed1 per lotFreestanding monumentNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – Freestanding (Monument).
Freestanding Sign (Pylon)Minimum height 6 ft.; maximum sign height 20 ft.50 sq. ft.Max. width 6 ft.Not listed1 per lotFreestanding pylon signNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – Freestanding (Pylon).
Roof SignMay not project any higher than 20 ft. above the roof2 sq. ft. per linear foot of building frontageNot listedNot listed1 per buildingOn roof of buildingNot listedUnlockTable: Sign Types by Zoning District – C-5-TO – Roof Sign.

PermitPal covers all 33 zoning districts in Baltimore. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Baltimore

  • No sign may be erected, relocated, or structurally altered unless in accordance with this Code. (§17-201(a))
  • All signs are subject to the location, height, quantity, and dimensional requirements of Table 17-201: Sign Regulations and as otherwise stated in Title 17. A sign is allowed within a zoning district only if Table 17-201 expressly lists that sign type as allowed within that zoning district and the sign complies with all other requirements of this title applicable to that sign type. (§17-201(b))
  • All signs must comply with the placement restrictions of the Baltimore City Building Code, Appendix H {Signs}. (§17-202(a))
  • No sign mounted on the exterior or interior of a building may cover any part of a window, door, or prominent architectural feature unless otherwise expressly allowed in Article 32. (§17-202(b)(1))
  • All sign structural design and construction, including supports, must comply with the City Building, Fire, and Related Codes. (§17-204(a))
  • Supports and braces for signs must be an integral part of the sign design and must be hidden from public view to the extent technically feasible, unless intended as a decorative part of the sign design. (§17-204(b))
  • All letters, figures, characters, or representations maintained in conjunction with, attached to, or superimposed on any sign must be safely and securely built or attached to the sign structure. (§17-204(c))
  • All exterior lighting intended to illuminate a sign must concentrate illumination on the area of the sign and be designed, located, shielded, and directed to minimize glare on streets and adjacent properties and to minimize distraction of motorists or pedestrians. (§17-204(d)(3)-(4))
  • The total cumulative square feet of all signs on a lot may not exceed the amounts specified in Table 17-306: Maximum Cumulative Area of Signs, except as allowed in an approved Signage Plan for an Area of Special Signage Control. (§17-306)
  • Any sign required by the City Building, Fire, and Related Codes that is over 2 square feet is subject to all applicable rules of Title 17, Table 17-201, and Table 17-306. (§17-309(b)(2))
  • All signs and the premises surrounding them must be maintained in a clean and sanitary condition, free of noxious substances, rubbish, and weeds; all unused sign hardware or wiring must be removed. (§17-205(a))
  • If the Building Official finds that any sign is unsafe, insecure, or constructed, erected, or maintained in violation of Title 17, the Official may order correction and, if not cured, the City may remove the sign at the permit holder’s or property owner’s expense; if the sign is an immediate peril, the City may remove it summarily and without notice. (§17-205(c))
  • No sign may be erected, placed, or maintained that is an attention-getting device within the R-1-A through R-10, R-MU, OR-1, OR-2, and EC-1 Zoning Districts; the City may not issue permits for these devices in those districts. (§17-403(a))
  • Attention-getting devices may not be erected or maintained in any location or manner that could endanger public safety, interfere with or obstruct pedestrian or vehicular travel, create a traffic safety problem, or be within any public right-of-way. (§17-403(b)(2)-(3))
  • No inflatable promotional device may exceed 15 feet in height or the height of the principal building to which it relates, whichever is lower, and no inflatable promotional device may be mounted on the roof of a structure. (§17-403(b)(5))
  • No person may place any sign, poster, placard, device, graphic display, or other item that advertises alcoholic beverages or cigarettes in any publicly visible location, including any outdoor billboard, side of a building, or freestanding sign, except as specifically allowed for licensed premises, temporary licenses, certain Areas of Special Signage Control, Maryland Stadium Authority property, limited identification signs at licensed premises, and billboards meeting distance requirements. (§17-402(a), (b))
  • Any billboard that advertises alcoholic beverages must be located at least 500 linear feet from established and conspicuously identified elementary or secondary schools, places of worship, or public playgrounds. (§17-402(b)(4))
  • Except as otherwise specifically provided, the erection, conversion, placement, or construction of new billboards, static or digital, is prohibited. (§17-406(a)(1))
  • No billboard may have audio speakers or any audio component. (§17-406(a)(2))
  • Existing non-digital billboards may only be converted to digital if they comply with the detailed removal, size, location, brightness, animation, and tax-payment conditions listed in §17-406(d), and may not be converted if attached to or mounted as specified in §17-406(e) (buildings or poles 35 feet or less, or within 250 feet of a residential district). (§17-406(d)-(e))
  • No sign may have or consist of any moving, rotating, or animated part or any flashing, blinking, fluctuating, or animated light, except on electronic signs and barber poles or similar rotating graphics. (§17-410)
  • No sign may display matter whose dominant theme appeals to a prurient interest in sex, is patently offensive under contemporary community standards regarding sexual matters, and is utterly without redeeming social value. (§17-411)
  • Portable signs may not be displayed outside of a building. (§17-413)
  • Non-obscene wording and graphics on table umbrellas are not governed by Title 17; by implication obscene wording/graphics on table umbrellas would still be prohibited under the obscene sign prohibition. (§17-201(c) and §17-411)
  • No electronic sign affixed to a building, including its support structure, may project beyond the ends or top of the wall or higher than any roofline of the structure to which it is attached. (§17-407(g)(1))
  • No wall sign affixed to a building, including its support structure, may project beyond the ends or top of the wall or higher than the roofline of the wall to which it is attached; wall signs may not be constructed of cloth or other flexible material, attached to unreinforced masonry parapets, or extend above the parapet. (§17-416(g))
  • No part of any freestanding sign may project into, over, or otherwise encroach on a public right-of-way. (§17-408(d))
  • Awning and canopy signs: back-lit box and plastic awnings and canopies are prohibited; frames and supports may not be wood or plastics; messages or graphics on the top surface of any awning or canopy may not exceed 25% of that surface area. (§17-404(c)-(d))
  • Signs may not be mounted on or extend beyond any roof surface except where roof signs are expressly allowed under roof-sign provisions. (§17-404(b)(5) and §17-415)
  • Painted/mural signs that seek to cover any window, door, or prominent architectural feature must have design review approval and, if covering windows, must meet transparency requirements for window signs. (§17-202(b)(2)-(3), §17-417)
  • Nonconforming signs are defined as lawfully erected under a previous Code but not now conforming; such signs remain subject to current maintenance, safety, and other general provisions of Title 17. (§17-102(o) in conjunction with §17-205)

Exempt Signs in Baltimore

  • Non-obscene wording and non-obscene graphics on table umbrellas are not governed by Title 17. (§17-201(c))
  • Any sign that is required by the City Building, Fire, and Related Codes and that is 2 square feet or less does not count toward the allowable maximum quantity of signs, the maximum area per sign, or the maximum cumulative area of signage on a lot. (§17-309(b)(1))
  • Changing the copy or message on an existing changeable copy sign, whether illuminated or non‑illuminated, is allowed (with any required permits) as long as there is no increase in sign dimensions or change in structure. (§17-205(b)(1))
  • Painting, repainting, cleaning, changing allowed items of information, and other normal maintenance and repair of a sign (including replacement of lights and sign face) are allowed (with any required permits) if they do not involve structural changes or changes in size. (§17-205(b)(2))
  • Refacing an existing sign is allowed (with any required permits) unless the sign is in an Historical and Architectural Preservation District or on a Landmark/Special List: Exteriors, in which case CHAP review is required. (§17-205(b)(3))
  • Replacement of the digital screen on an electronic sign is allowed (with any required permits) as long as sign dimensions and structure do not change. (§17-205(b)(4))
  • Replacement of broken or physically damaged sign supports is allowed (with any required permits) so long as there is no increase in sign dimensions or change in structure. (§17-205(b)(5))
  • Modifications necessary to improve the safety of existing signs are allowed (with any required permits) so long as there is no increase in sign dimensions or change in structure. (§17-205(b)(6))
  • Noncommercial speech is allowed wherever commercial speech is allowed under this Code; any place that permits a commercial sign must equally allow a noncommercial message under the same physical standards. (§17-203)
  • Window or exterior wall signs at licensed alcoholic beverage or cigarette premises that (i) are intended to identify the licensed premises by name, slogan, or logo, (ii) cover no more than 15% of the window or exterior wall area, and (iii) are the only such sign along that street frontage are exempt from the general prohibition on publicly visible alcoholic beverage and cigarette advertising. (§17-402(b)(3))
  • Signs inside a licensed alcoholic beverage or cigarette premises, signs used in conjunction with a temporary or 1‑day alcoholic beverages license, certain manufacturer‑related signs within an Area of Special Signage Control, and signs on Maryland Stadium Authority property are exempt from the general prohibition on publicly visible alcoholic beverage and cigarette advertising. (§17-402(b)(2))

Sign Plan & Submission Notes for Baltimore

  • The total cumulative area limits in Table 17-306 may be exceeded only as allowed in an approved Signage Plan for an Area of Special Signage Control; within such an area, the applicable column of Table 17-306 depends on the largest electronic sign category proposed for the property. (§17-306 and Table 17-306 note)
  • Areas of Special Signage Control (ASSC) may only be designated in the C-1, C-1-E, C-1-VC, C-2, C-3, C-4, C-5, IMU-1, IMU-2, OR, TOD districts, and the entire PC district is by default an ASSC unless its boundaries are amended. (§17-502)
  • Designation of an Area of Special Signage Control requires approval by ordinance of the Mayor and City Council, following the legislative procedures of Title 5, Subtitle 5, with special notice content requirements and Planning Commission review. (§17-503(a)-(b))
  • When reviewing an application for designation of an Area of Special Signage Control, the Planning Commission and City Council must find that the designation would not increase traffic congestion or distraction, would not add to visual clutter, and would not be incongruous with the existing or contemplated design of the area. (§17-503(c))
  • Once an area is designated as an Area of Special Signage Control, a Signage Plan is required and must be submitted to the Planning Commission before any signs may be erected in that area. (§17-504(a), §17-505(a))
  • Required contents of a Signage Plan for an Area of Special Signage Control include: (1) a list of sign types being sought, (2) the location and number of signs per lot or building, (3) the maximum dimensions per sign, and (4) the percentage deviations sought from by‑right area/height/cumulative‑area limits in Table 17-201 and Table 17-306. (§17-504(b))
  • A Signage Plan may include deviations from location, height, quantity, and dimensional requirements and may add certain sign types not generally permissible in the underlying district, but only where such deviations and types are expressly allowed for ASSC in Table 17-201 and Table 17-306. (§17-504(c))
  • The Board of Municipal and Zoning Appeals may not grant any variance for a sign that has been the subject of a deviation or addition in an approved Signage Plan for an Area of Special Signage Control. (§17-504(c)(3))
  • A Signage Plan may not alter or deviate from the standards required by the alcoholic beverage and cigarette advertising restrictions (§17-402) or the obscene sign prohibition (§17-411). (§17-504(e))
  • When calculating percentage deviations in a Signage Plan, any fractional result of 1/2 or more is rounded up to the next whole square foot of sign area or whole foot of height. (§17-504(d))
  • The Planning Commission must approve a Signage Plan before any signs may be erected within an Area of Special Signage Control and must find that the plan will not increase traffic congestion or distraction, will not add to visual clutter, will not be incongruous with the existing or contemplated design, and meets the limits in Table 17-201 and Table 17-306. (§17-505(b))
  • Amendments to the boundaries of an Area of Special Signage Control must be approved by ordinance; amendments to the Signage Plan itself must be approved by the Planning Commission. (§17-505(c))
  • An Area of Special Signage Control and its Signage Plan may be incorporated directly into a new planned unit development (PUD) ordinance; that ordinance must contain a dedicated 'Area of Special Signage Control' section and must satisfy the requirements of §§17-503(c) and 17-504. (§17-506(b)(i)-(iii))
  • For PUDs that incorporate an Area of Special Signage Control, boundary changes to the ASSC are treated as major changes and must be made by ordinance, while changes to the Signage Plan may generally be treated as minor changes approved by the Planning Commission unless tied to major physical changes in the PUD. (§17-506(b)(v)-(vi))
  • If a planned unit development is repealed and not replaced, any Area of Special Signage Control and its approved Signage Plan within that PUD may continue to be effective with the designated boundaries and plan. (§17-506(b)(vii))
  • Within certain non‑residential districts (e.g., EC-1, EC-2, OS, H, OIC, BSC, PC, various TOD and C-5 subdistricts), the ability to split aggregate sign area among multiple freestanding or building signs must be documented in a 'signage package', which functions as a coordinated sign plan for the site. (§17-206(c)(3) and (f)(4)(i))
  • For planned unit developments without an Area of Special Signage Control, the aggregate maximum freestanding monument and pylon sign area may be split among all buildings on the lot, not to exceed the sum allowed by Tables 17-201 and 17-306, and this option must be documented in a signage package within the PUD ordinance. (§17-206(f)(4)(i))
  • In IMU-1 and IMU-2, roof signs are allowed only 'ASSC ONLY' per Table 17-201, meaning a Signage Plan in an Area of Special Signage Control is required to authorize roof signs in those districts.
  • Certain higher-category electronic signs (Categories III, IV, and V) and new billboards are allowed only 'ASSC ONLY' per Table 17-201, and thus require inclusion and regulation within an approved Signage Plan for an Area of Special Signage Control.

Source: other municipal code