Sign Regulations in Chesapeake Town, Maryland
Chesapeake Town, Maryland has specific sign regulations covering 20 sign types across 4 zoning districts. Regulated sign types include General Development Opening Sign, Freestanding Sign, Projecting Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Chesapeake Town, Maryland
Sample Sign Requirements in Chesapeake Town
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Freestanding Sign | 6 ft | 30 sq ft | 8 ft min from property line. |
| Window Sign | Not listed | No more than 25% of window area | Not listed |
| Wall/Flat-Mounted Sign | No higher than second-floor windowsill on a building. | 30 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
20
- General Development Opening Sign
- Freestanding Sign
- Projecting Sign
- Window Sign
- +2 more types
Zoning Districts
4
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Other Cities in Maryland
Frequently Asked Questions
In Chesapeake Town, the height limit for Freestanding Sign (Public/Open Space/Institutional/Assembly/Multifamily) in the Traditional Neighborhood Development District (TND) and other zoning districts is 6 ft (Sec. 120-6.5.7(A)(1)). Maximum sign heights range from 6 ft to 8 ft across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Chesapeake Town require a permit. From the submission notes on this page: An application for a sign permit must include elevations and plans of all proposed signs drawn to scale, with all dimensions noted, and show the location of each sign. Run a code check for an exact address to see the permit requirements for that zone.
Chesapeake Town's sign code covers 20 sign types, including General Development Opening Sign, Freestanding Sign, Projecting Sign, and Window Sign. Most commercial signs need a permit. The ordinance lists 6 exemptions. One of them: Official traffic and parking signs provided they are erected by a governmental agency. The full list is on this page.
In Chesapeake Town, Freestanding Sign (Public/Open Space/Institutional/Assembly/Multifamily) in the Traditional Neighborhood Development District (TND) and other zoning districts must be set back at least 8 ft from property line (Sec. 120-6.5.7(A)(1)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Chesapeake Town's sign ordinance that cover digital, changing, or flashing signs: No sign shall project any intermittent, light-emitting diode, or flashing illumination except for official public road or street signs intended to promote traffic safety. New electronic message centers (EMCs) and digital electronic signs of any kind are prohibited. No flashing or rotating signs shall be permitted. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Chesapeake Town Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Chesapeake Town, Maryland, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Chesapeake Town, Maryland Sign Rules at a Glance
Chesapeake Town, Maryland regulates 20 sign types across 4 zoning districts. Freestanding Signs (Home Occupation/Day Care/Bed and Breakfast) in the Traditional Neighborhood Development District (TND) and other zoning districts are capped at 4 ft tall and 4 sq ft, set back at least 8 ft from property line (Sec. 120-6.5.7(C)(1)). Most commercial signs in Chesapeake Town require a permit.
Detailed Sign Ordinance Requirements for Chesapeake Town, Maryland
Sign Rules by Zoning District in Chesapeake Town (4 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Commercial District (GC), Marine Commercial District (MC), Village Center District (V-1), Village Commercial District (V-2) | 7 | 8 ft | 64 sq ft | Not listed |
| Traditional Neighborhood Development District (TND), Resource Conservation District (RC) | 6 | 8 ft | 32 sq ft | Not listed |
| Historic District | 1 | Not listed | Not listed | Not listed |
| General Regulations For All Zones | 7 | 6 ft | 25% of window area | Not listed |
Zone-by-Zone Sign Requirements in Chesapeake Town(sample of 3 of 4 zones)
General Commercial District (GC), Marine Commercial District (MC), Village Center District (V-1), Village Commercial District (V-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign | 6 ft | 30 sq ft | Not listed | 8 ft min from property line. | 1 per site; more with sign program (see additional requirements) | Minimum 8-foot setback from any property line; not within or overhanging ROW. | Not listed | Unlock | §120-6.5.6(A); Table (Land Use - Commercial), Article 6.5 |
| Projecting Sign | Not listed | Not listed | Not listed | Not listed | 2 per linear building frontage; see note for larger buildings | Attached to building. Max projection of 38 inches from face. Minimum 8-ft clearance from ground/sidewalk. | Not listed | Unlock | §120-6.5.6(B); Table (Land Use - Commercial), Article 6.5 |
| Window Sign | Not listed | No more than 25% of window area | Not listed | Not listed | Not listed | Interior of window, to be viewed from outside. | Not listed | Unlock | §120-6.5.4(A)(6), §120-6.5.6(C) |
| Wall/Flat-Mounted Sign | No higher than second-floor windowsill on a building. | 30 sq ft | Not listed | Not listed | Not listed | Wall-mounted, no higher than second-floor windowsill. | Not listed | Unlock | §120-6.5.6(D); Table (Land Use - Commercial), Article 6.5 |
| A-frame (Sandwich Board) Sign | 4 ft | 6 sq ft (one side); 12 sq ft (double-sided) | Not listed | Not listed | 2 per street frontage | In public right-of-way per business; not impeding traffic; if >35 mph road - 60 ft set back from ROW. | Not listed | Unlock | §120-6.5.6(F); Table (Land Use - Commercial), Article 6.5 |
| Marquee Sign | Not listed | Not listed | Not listed | Not listed | 1 per site | Not listed | Not listed | Unlock | §120-6.5.6(E); Table (Land Use - Commercial), Article 6.5 |
| General Development Opening Sign | 8 ft | 64 sq ft | Not listed | Not listed | 1 per development opening | Not listed | Not listed | Unlock | §120-6.5.5(D)(1) |
Traditional Neighborhood Development District (TND), Resource Conservation District (RC)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign (Public/Open Space/Institutional/Assembly/Multifamily) | 6 ft | 20 sq ft per sign face | Not listed | 8 ft min from property line | 1 per road frontage | 1 per road frontage | Not listed | Unlock | §120-6.5.7(A)(1) |
| Wall-Mounted Sign (Public/Open Space/Institutional/Assembly/Multifamily) | Not listed | 20 sq ft | Not listed | Not listed | 1 | Not listed | Not listed | Unlock | §120-6.5.7(A)(2) |
| Subdivision/Community Entrance Sign | 6 ft | 24 sq ft | Not listed | Not listed | 1 per street entrance | At street entrance; 1 per street entrance | Not listed | Unlock | §120-6.5.7(B) |
| Freestanding Sign (Home Occupation/Day Care/Bed and Breakfast) | 4 ft | 4 sq ft | Not listed | 8 ft min from property line | 1 per lot per road frontage | 1 per lot per street frontage. | Not listed | Unlock | §120-6.5.7(C)(1) |
| Wall-Mounted Plaque/Nameplate Sign (Home Occupation/Day Care/Bed and Breakfast) | Not listed | 2 sq ft | Not listed | Not listed | 1 | Not listed | Not listed | Unlock | §120-6.5.7(C)(2) |
| General Development Opening Sign | 8 ft | 32 sq ft | Not listed | Not listed | 1 per development opening | Not listed | Not listed | Unlock | §120-6.5.5(D)(2) |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Temporary Sign | 4 ft | 6 sq ft | Not listed | Not listed | No more than 2 per property, or 1 per property with a legal nontemporary sign | Not listed | Not listed | Unlock | §120-6.5.4(A)(2) |
| Parking Lot Accessory Sign - Entrance/Exit | Not listed | 2 sq ft | Not listed | Not listed | 1 per entrance, 1 per exit | At parking lot entrance/exit | Not listed | Unlock | §120-6.5.4(A)(3)(a) |
| Parking Lot Accessory Sign - Condition of Use/Owership | Not listed | 9 sq ft | Not listed | Not listed | 1 | Parking area | Not listed | Unlock | §120-6.5.4(A)(3)(b) |
| Parking Lot Accessory Sign - General | 6 ft | Not listed | Not listed | Not listed | Not listed | Parking area | Not listed | Unlock | §120-6.5.4(A)(3)(c) |
| Commemorative Plaque | Not listed | 4 sq ft | Not listed | Not listed | 1 per building | Cut into/affixed to permanent surface | Not listed | Unlock | §120-6.5.4(A)(4) |
| Street Number/Address/Name Sign | Not listed | 1 sq ft in TND; 3 sq ft in other districts | Not listed | Not listed | 2 per building | Building | Not listed | Unlock | §120-6.5.4(A)(5) |
| Window Display Sign (Interior) | Not listed | 25% of window area | Not listed | Not listed | Not listed | Interior to structure, visible from outside | Not listed | Unlock | §120-6.5.4(A)(6) |
PermitPal covers all 4 zoning districts in Chesapeake Town. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Chesapeake Town
- No signs shall be attached to utility poles, traffic signal poles, traffic control posts/signs, rocks, or trees visible from the public right-of-way whether on public or private property.
- Except for official public wayfinding signs and official directional, safety or traffic signs, no sign whether temporary or permanent shall be placed within any public rights-of-way within the Town unless specified within this article.
- No sign shall be located which will interfere with traffic visibility along the right-of-way of any street or along any private driveway exiting or entering a site or on any slope or drainage easement of a street.
- No signs shall be attached to the sloped section of a roof structure, except in the General Commercial District.
- No sign may be painted directly on any wall or roof of a building or on a fence visible from the public right-of-way.
- No sign shall project any intermittent, light-emitting diode, or flashing illumination except for official public road or street signs intended to promote traffic safety. New electronic message centers (EMCs) and digital electronic signs of any kind are prohibited.
- No flashing or rotating signs shall be permitted.
- Pennants, streamers, and moving, flashing, windblown and all other fluttering, spinning, or similar type signs, which includes strings of light bulbs, balloons or other inflated objects, are prohibited, except for special events with Zoning Administrator approval for the event period.
- Except for official traffic signs, no sign shall be displayed, visible from the public right-of-way, which uses the word "stop" or "danger" or that implies a need for or requirement of stopping or the existence of danger.
- Signs that are obscene, illegal, hazardous to traffic, imitative of official government signs (i.e., stop, danger, caution, etc.) or obstructive to public visibility, so as to create a hazard to the public, are prohibited.
- Signs attached to a parked motor vehicle, exceeding 12 square feet in area or the maximum allowable height for freestanding signs in the zoning district shall be prohibited.
- Billboard signs are prohibited.
- No sign shall be permitted which becomes unsafe or endangers the safety of a building, premises, or person.
- No sign shall be permitted to remain which through damage, disrepair or lack of maintenance has become impaired in its functionality or blighted in its appearance.
- Failure to comply with an order to repair or remove an unsafe/blighted sign results in the loss of any legal nonconforming status and requires removal or compliance.
- When a sign structure does not include a sign for a period of 90 consecutive days, such sign structure shall be deemed a violation and shall be removed.
- No sign shall obstruct a clear view to and from traffic along any street right-of-way, entrance, or exit.
- A sight visibility triangle shall be kept free of obstructions to vision between the heights of 2.5 feet and 12 feet above the street.
- Except within the General Commercial and Marine Commercial Districts, no internally lighted signs shall be permitted within Town. Where illumination of a sign is permitted, it shall be by indirect means external to the sign face.
- Any sign placed in public view for which no sign permit has been issued, and that is not otherwise exempted from the permit requirement, is unlawful.
- No person shall install, place, or maintain an unlawful sign and no person shall allow or permit the installation, placement, or maintenance of an unlawful sign on property owned by the person.
Exempt Signs in Chesapeake Town
- Official traffic and parking signs provided they are erected by a governmental agency.
- Temporary signs, subject to: a property shall not display any temporary sign for more than 90 days in a year; sign is no larger than six square feet in area and four feet in height; no more than two temporary signs at the same time on a property (only one if the property already has a legal nontemporary sign); temporary signs shall not be illuminated.
- Signs accessory to parking lot uses: entrance/exit signs limited to one per entrance/exit (max two square feet in area), one additional sign up to nine square feet for conditions of use or ownership, and no such sign over six feet in height.
- Commemorative plaques: signs commemorating a historical building, its name register and/or erection date, when cut into or affixed to a permanent surface and not exceeding four square feet per building.
- Street number, address, and/or name: two such signs for each building not exceeding one square foot each in the TND District and three square feet each in all other zoning districts.
- Window displays and signs: interior signs to be viewed from the outside provided no more than 25% of the window area is covered; the area of window signage shall be included in the count of maximum allowable sign area and sign number for the site; no such sign shall be an internally lighted sign.
Sign Plan & Submission Notes for Chesapeake Town
- A sign program (sign plan) is required for any multiple occupancy commercial, professional, industrial, residential, or institutional sites or separately identifiable building group, such as a medical complex or shopping center, or an individual site of at least one acre in size or with a proposed development exceeding 10,000 square feet of total building space.
- A sign program must be approved by the Planning Commission. For sites in the Historic District, prior approval by the Historic District Commission is also required.
- An application for a sign permit must include elevations and plans of all proposed signs drawn to scale, with all dimensions noted, and show the location of each sign.
- After approval of a sign permit and/or sign program, each sign installed and maintained on the subject site shall comply with the permit and program.
- A sign program shall comply with all provisions of the ordinance and is not intended to provide special or additional signage.
- Approval of a sign permit or sign program requires findings that the proposed signs do not exceed ordinance standards and are in substantial conformance with the Town's design criteria.
- Within the Historic District, all new signs and any existing signs to be altered in size, shape, or location require a permit of approval (certificate of approval) from the Historic District Commission.
- Applicants for sign permits in the Historic District should refer to the Historic District Commission's design guidelines for signs.
- No site plan for any property shall be approved unless it provides that all existing nonconforming signs and new signs are made to conform to the provisions of this article.