Sign Regulations in Leonardtown Town, Maryland
Leonardtown Town, Maryland has specific sign regulations covering 21 sign types across 5 zoning districts. Regulated sign types include Subdivision/Planned Unit Development Identification Sign, Billboard, Roof Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Leonardtown Town, Maryland
Sample Sign Requirements in Leonardtown Town
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Billboard | Prohibited | Prohibited | Not listed |
| Roof Sign | Prohibited | Prohibited | Not listed |
| Temporary Real Estate Sign (up to 24 sq ft) | Not listed | 24 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
21
- Subdivision/Planned Unit Development Identification Sign
- Billboard
- Roof Sign
- Temporary Real Estate Sign (up to 24 sq ft)
- +2 more types
Zoning Districts
5
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Leonardtown Town
Other Cities in Maryland
Frequently Asked Questions
In Leonardtown Town, the height limit for Electronic or Digital Sign (Ground Monument, Route 5 Only) in the General Commercial (C-G) and other zoning districts is 8 ft total, LED portion max 4 ft high (Sec. 155-93I(1)-(3)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Leonardtown Town require a permit. From the submission notes on this page: Permits are required for all signs unless exempt. The permit application must include the applicant and owner name, location, design drawings, and dimensions of the sign. Run a code check for an exact address to see the permit requirements for that zone.
Leonardtown Town's sign code covers 21 sign types, including Subdivision/Planned Unit Development Identification Sign, Billboard, Roof Sign, and Temporary Real Estate Sign (up to 24 sq ft). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Signs erected on church property, giving the name of the church, the time of service and similar information, not to exceed 30 square feet in area, are exempt from registration and permit requirements, provided they meet structural and safety provisions of the Town Building Code. The full list is on this page.
In Leonardtown Town, Residential Name Sign in the Single-Family Residential (R-SF), PUD-3, PUD-5 zoning districts must be set back 6 ft. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Leonardtown Town's sign ordinance that cover digital, changing, or flashing signs: No electronic, digital, or video display message shall be mounted, affixed or attached to any vehicle, motor vehicle or trailer. This prohibition shall include vehicles, motor vehicles or trailers designed, built, or used specifically for mobile advertising. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Leonardtown Town Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Leonardtown Town, Maryland, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Leonardtown Town, Maryland Sign Rules at a Glance
Leonardtown Town, Maryland regulates 21 sign types across 5 zoning districts. Street Address Signs in the Single-Family Residential (R-SF), PUD-3, PUD-5 zoning districts are capped at 5 ft tall and 2 sq ft, with a 6 ft setback. Most commercial signs in Leonardtown Town require a permit.
Detailed Sign Ordinance Requirements for Leonardtown Town, Maryland
Sign Rules by Zoning District in Leonardtown Town (5 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 7 | 8 ft (top above grade) | 60 sq ft | Not listed |
| Single-Family Residential (R-SF), PUD-3, PUD-5 | 5 | 5 ft | 10 sq ft | Not listed |
| Multiple-Family Residential (R-MF) | 3 | 5 ft | 10 sq ft | Not listed |
| R-1 | 1 | 5 ft | 2 sq ft | Not listed |
| General Commercial (C-G), Commercial Office (C-O), Marine Commercial (C-M), Highway Commercial (C-H) | 6 | 8 ft | 100+ sq ft (see formula) | Not listed |
Zone-by-Zone Sign Requirements in Leonardtown Town(sample of 3 of 5 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Billboard | Prohibited | Prohibited | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | § 155-93A(1) |
| Roof Sign | Prohibited | Prohibited | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | § 155-90H |
| Temporary Real Estate Sign (up to 24 sq ft) | Not listed | 24 sq ft | Not listed | Not listed | 1 per lot or frontage | On property for sale; additional sign for multiple frontages. | Not listed | Unlock | § 155-94A(1), (4) |
| Temporary Real Estate Sign (up to 60 sq ft) | Not listed | 60 sq ft | Not listed | Not listed | 1 per subdivision | Within subdivision advertised | Not listed | Unlock | § 155-94A(2) |
| Temporary Real Estate Approach Sign | 8 ft (top above grade) | 3 sq ft (3 ft long x 1 ft high) | 3 ft | Not listed | 4 per subdivision | Near each major intersection to the subdivision | Not listed | Unlock | § 155-94A(3)-(4) |
| Temporary Event Sign | Not listed | 32 sq ft | Not listed | Not listed | Not listed | On site of event | Not listed | Unlock | § 155-94B(1) |
| Temporary Directional Event Sign | Not listed | 3 sq ft | Not listed | Not listed | Not listed | Any district; directional arrow and event name required | Not listed | Unlock | § 155-94B(2) |
Single-Family Residential (R-SF), PUD-3, PUD-5
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Residential Name Sign | 5 ft | 2 sq ft | Not listed | 6 ft | 2 per dwelling | Per dwelling | Not listed | Unlock | § 155-91A(1), D |
| Business Sign (Professional Occupation) | 5 ft | 2 sq ft | Not listed | 6 ft | 2 per dwelling | Per dwelling | Not listed | Unlock | § 155-91A(2), D |
| Street Address Sign | 5 ft | 2 sq ft | Not listed | 6 ft | 1 per dwelling | Per dwelling | Not listed | Unlock | § 155-91A(3), D |
| Business Sign (PUD-3 or PUD-5) | 5 ft | 2 sq ft | Not listed | 6 ft | 2 per business use | Per business use permitted in PUD-3 or PUD-5 | Not listed | Unlock | § 155-91A(4), D |
| Subdivision/Planned Unit Development Identification Sign | 5 ft | 10 sq ft | Not listed | 6 ft | Not listed | At entrance to subdivision or PUD | Not listed | Unlock | § 155-91C, D |
General Commercial (C-G), Commercial Office (C-O), Marine Commercial (C-M), Highway Commercial (C-H)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Flat Wall Sign | Not above first floor | 100+ sq ft (see formula) | Not listed | Not listed | Total sign area regulated per frontage | Anywhere on any wall of building, except above first floor. | Not listed | Unlock | § 155-93C(2)-(4), E(1) |
| Ground Sign | 8 ft | 32 sq ft | Not listed | Must meet yard/setback for district; at least 2 ft from building. | 1 per lot | On lot with minimum 40 linear feet street frontage. | Not listed | Unlock | § 155-93D(2)-(8); E(1)-(8) |
| Pole Sign | Not listed | 32 sq ft | Not listed | Not listed | Not listed | On lot | Not listed | Unlock | § 155-93G(2), (2)(a)-(b), D(2)-(8) |
| Marquee Sign | No part projects above top of marquee; no part less than 8 ft above sidewalk/grade; may project below lower edge of marquee up to 24 inches | Not listed | Not listed | Not listed | Not listed | On vertical face or below lower edge of marquee; for theater marquees over right-of-way with variance. | Not listed | Unlock | § 155-93F(1)-(3) |
| Projecting Sign | No portion below 8 ft above ground/pavement; usually may not extend above roofline except as noted | 15 sq ft | Not listed | Not listed | Not listed | On building; only in C-G, C-H, C-M | Not listed | Unlock | § 155-93H(1)-(2) |
| Electronic or Digital Sign (Ground Monument, Route 5 Only) | 8 ft total, LED portion max 4 ft high | 24 sq ft or 50% of total permitted sign face, whichever is less | Not listed | Subject to yard/setback of district | Not listed | Route 5 only | Not listed | Unlock | § 155-93I(1)-(3) |
PermitPal covers all 5 zoning districts in Leonardtown Town. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Leonardtown Town
- No sign shall be erected at or near street intersections, so as to permit free and clear vision.
- All signs shall avoid the shape of authorized traffic signs and shall not use the words 'stop,' 'look,' 'danger' or any other similar words that might interfere with or confuse traffic.
- All fire escapes, fire windows and fire doors shall be free of any signs other than those announcing the safety function of such stairs, windows and doors.
- The erection of banners across any street shall be on a temporary basis only and only at the approval of the Town Commissioners.
- All signs shall be kept in good repair.
- All signs shall meet the pertinent structural and safety requirements of the Town Building Code.
- No person shall display upon any sign or other advertising structure any obscene, indecent or immoral matter.
- Roof signs shall be prohibited.
- Except as otherwise noted, all signs shall meet the setback requirements in each district for all other structures or buildings in that district.
- Billboards and all other outdoor advertising structures shall be prohibited in all districts.
- No sign shall have blinking, flashing or fluttering lights or other illuminating devices which change light intensity, brightness or color. A variance may be granted by the Zoning Board for signs having moving devices to show the time, temperature and date only. Beacon lights or searchlights shall not be permitted for any advertising or sign purpose.
- No electronic, digital, or video display message shall be mounted, affixed or attached to any vehicle, motor vehicle or trailer. This prohibition shall include vehicles, motor vehicles or trailers designed, built, or used specifically for mobile advertising.
- Any signs not expressly permitted shall be prohibited.
Exempt Signs in Leonardtown Town
- Signs advertising the name of a commercial establishment and the name of the person conducting the business, when painted on the windows of such establishments, are exempt from registration and permit requirements, provided they meet structural and safety provisions of the Town Building Code.
- Signs erected on church property, giving the name of the church, the time of service and similar information, not to exceed 30 square feet in area, are exempt from registration and permit requirements, provided they meet structural and safety provisions of the Town Building Code.
- Signs of charitable, benevolent or religious associations, or fraternal or nonprofit associations, located on the premises or grounds, to display the name of the institution or association and its activities or services, not to exceed 10 square feet in area, are exempt from registration and permit requirements, provided they meet structural and safety provisions of the Town Building Code.
- Professional signs denoting the name and profession or calling of persons such as but not limited to dentist, minister, teacher, lawyer or physician, with such signs being the size and type permitted by the ethical standards of the profession or calling and in no case exceeding two square feet in area, are exempt from registration and permit requirements, provided they meet structural and safety provisions of the Town Building Code.
- Directional signs, giving directions to motorists to parking areas or into or within a private premises, not to exceed eight square feet in area, are exempt from registration and permit requirements, provided they meet structural and safety provisions of the Town Building Code.
Sign Plan & Submission Notes for Leonardtown Town
- No explicit requirements for a master sign plan, sign plan, or required variance meetings generally, except: Electronic or digital signs located within 100 feet of residential properties are permitted only after a public hearing at a planning and zoning meeting, notification of surrounding neighbors by certified mail and newspaper notice, and approval by the Planning and Zoning Board.
- Permits are required for all signs unless exempt. The permit application must include the applicant and owner name, location, design drawings, and dimensions of the sign.
Source: ecode360 municipal code