Questions? Call us at (262) 218-2915

Sign Regulations in Dewitt Township, Michigan

Dewitt Township, Michigan has specific sign regulations covering 22 sign types across 9 zoning districts. Regulated sign types include Temporary Sign, Home Occupation Sign (Wall or Freestanding), Institutional Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: October 3, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Dewitt Township, Michigan

Sample Sign Requirements in Dewitt Township

Sign TypeMax HeightMax AreaSetback
Home Occupation Sign (Wall or Freestanding)4 ft4 sq ftPlacement standards in Section 5.4.D.7.iv and Section 5.16 apply
Farm Enterprise Freestanding Sign8 ft34 sq ftSee Section 5.4.D.7.iv and Section 5.16
Temporary Sign8 ft34 sq ftPlacement per Section 5.4.D.7 and Section 5.16

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Dewitt TownshipFull Coverage

Sign Types Covered

22

  • Temporary Sign
  • Home Occupation Sign (Wall or Freestanding)
  • Institutional Wall Sign
  • Institutional Freestanding Sign
  • +2 more types

Zoning Districts

9

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Dewitt Township

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Dewitt Township, the height limit for Expressway Freestanding Sign in the Planned Office Development (POD) zoning district is 15 ft (Sec. 5.4.D.5.iv). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Dewitt Township require a permit. From the submission notes on this page: The planning commission may approve modifications to planting requirements to ensure visibility of freestanding signs, indicating sign-related coordination may be required as part of a broader landscape/site plan review (Section 5.4.D.8). Run a code check for an exact address to see the permit requirements for that zone.

Dewitt Township's sign code covers 22 sign types, including Temporary Sign, Home Occupation Sign (Wall or Freestanding), Institutional Wall Sign, and Institutional Freestanding Sign. Most commercial signs need a permit. The ordinance lists 12 exemptions. One of them: Flags. The full list is on this page.

In Dewitt Township, Expressway Freestanding Sign in the Planned Office Development (POD) zoning district must be set back at least 10 ft from expressway right-of-way (Sec. 5.4.D.5.iv). The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Dewitt Township's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.

AI-Powered Research

Ready to Research Dewitt Township Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Dewitt Township, Michigan, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Dewitt Township, Michigan Sign Rules at a Glance

Dewitt Township, Michigan regulates 22 sign types across 9 zoning districts. Institutional Freestanding Signs in the Agricultural District (A) are capped at 8 ft tall and 34 sq ft (Sec. 5.4.C.2.iv(2)). Most commercial signs in Dewitt Township require a permit.

Detailed Sign Ordinance Requirements for Dewitt Township, Michigan

Sign Rules by Zoning District in Dewitt Township (9 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Agricultural District (A)78 ft34 sq ftNot listed
Residential District (R-1, R-2, R-3, R-4, R-5, R-6)68 ftCombined 40 sq ft per street entranceNot listed
Multiple Family Residential District (M-1, M-2, M-3, M-4)36 ftCombined 40 sq ft per street entranceNot listed
Mobile Home Park District (MHP)48 ft100 sq ftNot listed
Institutional District48 ft34 sq ftNot listed
Commercial District (BC, BL, BSC), Office District (OP, PO, POD), Industrial Park District (IP), Industrial Light District (IL), Industrial Heavy District (IH)6Max 20 ft overall52 sq ftNot listed
Planned Office Development (POD)515 ftSingle sign: 200 sq ft; Combined: 300 sq ft (max 2 signs)Not listed
General Regulations For All Zones1Not listedNot listedNot listed
Industrial Park District (IP), Industrial Light District (IL), Industrial Heavy District (IH)130 ft300 sq ftNot listed

Zone-by-Zone Sign Requirements in Dewitt Township(sample of 3 of 9 zones)

Agricultural District (A)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Home Occupation Sign (Wall or Freestanding)4 ft4 sq ftNot listedPlacement standards in Section 5.4.D.7.iv and Section 5.16 apply1 per parcelOn-premises, flat against building wall or freestandingNot listedUnlockSection 5.4.C.2.i
Farm Enterprise Freestanding Sign8 ft34 sq ftNot listedSee Section 5.4.D.7.iv and Section 5.161 per parcel, plus 1 per distinct collection of buildingsOn-premisesNot listedUnlockSection 5.4.C.2.ii(1)
Farm Enterprise Wall SignNot listedNot listedNot listedNot listedNot listedFlat against building wallNot listedUnlockSection 5.4.C.2.ii(2)
Temporary Sign8 ft34 sq ftNot listedPlacement per Section 5.4.D.7 and Section 5.16Not listedOn-premisesNot listedUnlockTable 5.4.E
Institutional Wall SignNot listedNot listedNot listedNot listed1 per institutionFlat against building or canopyNot listedUnlockSection 5.4.C.2.iv(1)
Institutional Freestanding Sign8 ft34 sq ftNot listedNot listed1 per institutionOn-premisesNot listedUnlockSection 5.4.C.2.iv(2)
Ballfield/Activity Area Wall/Fence Sign (Institutional)Not listedNot listedNot listedNot listedNot listedInterior facing wall/fence of ball fields/activity areasNot listedUnlockSection 5.4.C.2.iv(3)

Residential District (R-1, R-2, R-3, R-4, R-5, R-6)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Home Occupation Sign (Wall or Freestanding)4 ft4 sq ftNot listedPlacement standards per Section 5.4.D.7.iv and Section 5.161 per parcelOn-premises, fixed to building or freestandingNot listedUnlockSection 5.4.C.2.i
Housing Development Freestanding Sign6 ftCombined 40 sq ft per street entranceNot listedNot listed2 per street entranceAt entrance(s) to developmentNot listedUnlockSection 5.4.C.2.iii
Institutional Wall SignNot listedNot listedNot listedNot listed1 per institutionFlat against building wall or parallel to wall on canopyNot listedUnlockSection 5.4.C.2.iv(1)
Institutional Freestanding Sign8 ft34 sq ftNot listedNot listed1 per institutionOn-premisesNot listedUnlockSection 5.4.C.2.iv(2)
Ballfield/Activity Area Wall/Fence Sign (Institutional)Not listedNot listedNot listedNot listedNot listedInterior facing wall/fenceNot listedUnlockSection 5.4.C.2.iv(3)
Temporary Sign4 ft4 sq ftNot listedPer Section 5.4.D.7 and Section 5.16Not listedOn-premisesNot listedUnlockTable 5.4.E

Planned Office Development (POD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Entrance Freestanding Sign10 ft42 sq ftNot listedDesign/placement per Section 5.4.D.7; address number as per 5.4.D.5.vi1 (2 if qualifying)At/near vehicular entrance, perimeter along public streetNot listedUnlockSection 5.4.D.5.i
Internal Identification Sign (Freestanding/Wall)10 ft (freestanding)Total 42 sq ft per buildingNot listedFreestanding sign per design standards in 5.4.D.71 freestanding, or up to 2 wall signs per buildingOriented to internal roadways/parkingNot listedUnlockSection 5.4.D.5.ii
Development Wall SignNot listedSingle sign: 200 sq ft; Combined: 300 sq ft (max 2 signs)Not listedNot listedMax 2 per developmentOn any single building within developmentNot listedUnlockSection 5.4.D.5.iii
Expressway Freestanding Sign15 ft150 sq ftWidth of sign structure not to exceed sign face width by more than 50%Min 10 ft from expressway ROW; min 150 ft from other public road ROW1 (in lieu of development signs)Along limited access expressway/interchangeNot listedUnlockSection 5.4.D.5.iv
Temporary Sign10 ft32 sq ftNot listedSection 5.4.D.7 and Section 5.16Not listedOn-premisesNot listedUnlockTable 5.4.E

PermitPal covers all 9 zoning districts in Dewitt Township. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Dewitt Township

  • Any sign which, by reason of its size, location, coloring, or manner of illumination, constitutes a traffic hazard or a detriment to traffic safety by obstructing the vision of drivers, or by obstructing or detracting from the visibility of any traffic control device on public streets and roads.
  • Signs that would interfere with, mislead or confuse traffic, including signs that simulate or could be confused with the lighting of emergency vehicles or traffic signals.
  • Signs and sign structures that are no longer in use as originally intended or have been abandoned; or are structurally unsafe, constitute a hazard to safety and health, or those not kept in good repair.
  • Any sign which obstructs free ingress to or egress from a required door, window, fire escape or other required exit way.

Exempt Signs in Dewitt Township

  • No hunting, no trespassing signs and on-premises directional signs not exceeding four square feet in area.
  • Signs located in the interior of buildings.
  • Any identification or address sign affixed to a wall, mailbox, post, lamp post, or pillar; and which is not larger than two square feet in display surface; and not for the purpose of advertising a home occupation.
  • Traffic control or other municipal signs such as, but not limited to, directional signs placed in rights-of-way, legal notices, railroad crossing signs, danger and other temporary emergency signs.
  • Memorial signs or tablets, names of buildings, and dates of erection, when cut into any masonry surface or when constructed of bronze or other non-combustible material.
  • Flags.
  • Change of copy on any sign designed for periodic changes, such as message board signs and billboards.
  • Signs located on the premises of a farm that identify and advertise seed, fertilizer, herbicide, pesticide, feed, feed supplements, livestock, or agricultural test plots that do not exceed six square feet in display area.
  • Historical markers describing designation by a state or federal agency of a historic site or structure that do not exceed 18 square feet.
  • Family names, farm names, or agricultural icons, such as farm implements, livestock, or field crops, patterned in the roof shingles of a farm structure.
  • Signs to improve the community aesthetic character, place-making, or promote a community message that adds community value subject to administrative approval by the Planning Department.
  • Temporary event signs that will be utilized for a period not to exceed 30 days for said event shall, with administrative approval by the planning department, not require sign permits, provided they are placed the required distances from the road right of way as required by Section 5.16 of the zoning ordinance.

Sign Plan & Submission Notes for Dewitt Township

  • The planning commission may approve modifications to planting requirements to ensure visibility of freestanding signs, indicating sign-related coordination may be required as part of a broader landscape/site plan review (Section 5.4.D.8).
  • Temporary event signs may be administratively approved by the Planning Department without a permit, indicating that an administrative review/sign plan is required prior to placement.
  • Interior facing ball field/ball diamond/recreational activity area signage must be administratively approved by the zoning official, demonstrating a sign plan/administrative approval process.
  • The installation of signs at all ballfields will be managed via a sponsorship policy developed by township staff and approved by the township board, suggesting a coordinated sign planning process for sponsorship signage.
  • For sponsorship signage at ballfields, fees and other requirements are established through a board-approved fee schedule, implying a sign plan or sponsorship plan may be required.

Source: other municipal code