Questions? Call us at (262) 218-2915

Sign Regulations in Goodrich, Michigan

Goodrich, Michigan has specific sign regulations covering 32 sign types across 6 zoning districts. Regulated sign types include Wall Sign, Canopy Sign, Directional Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Goodrich, Michigan

Sample Sign Requirements in Goodrich

Sign TypeMax AreaSetback
Nameplate and Address Sign2 sq. ft.Must be outside public street right-of-way.
Integral SignNot listedMust be outside public street right-of-way.
Home Occupation Identification Sign1 sq. ft.Must be outside public street right-of-way.

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for GoodrichFull Coverage

Sign Types Covered

32

  • Wall Sign
  • Canopy Sign
  • Directional Sign
  • Projecting Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Goodrich

City WebsiteMunicipal Code3 permit application links available

Goodrich, Michigan Sign Rules at a Glance

Goodrich, Michigan regulates 32 sign types across 6 zoning districts. Sandwich Board Signs in the General Business District (GBD) are capped at 36 in tall, 6 sq ft, and 24 in wide. Most commercial signs in Goodrich require a permit.

Detailed Sign Ordinance Requirements for Goodrich, Michigan

Sign Rules by Zoning District in Goodrich (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax Area
VLDR Residential, LDR Residential, VCR Residential, MDR Residential156 ft.32 sq. ft. cumulative per lot
Central Business District (CBD)842 in20 sq. ft.
Office-Service District515 ft.40 sq. ft.
General Business District (GBD)1036 in.100 sq. ft.
Industrial District44 ft.24 sq. ft.
General Regulations For All Zones1Not listedNot listed

Zone-by-Zone Sign Requirements in Goodrich(sample of 3 of 6 zones)

VLDR Residential, LDR Residential, VCR Residential, MDR Residential

Sign TypeMax HeightMax AreaSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Nameplate and Address SignNot listed2 sq. ft.Must be outside public street right-of-way.Not listedAttached to mailbox, light fixture, or exterior wall.UnlockSec. 36-823(1), Table 18.6
Home Occupation Identification SignNot listed1 sq. ft.Must be outside public street right-of-way.1 per parcelAttached to exterior building wall.UnlockSec. 36-823(3), Table 18.6
Non-profit Organization/Institution Sign6 ft.25 sq. ft.Must be outside public street right-of-way.Not listedNot listedUnlockSec. 36-823(4), Table 18.6
Construction Sign6 ft.16 sq. ft.Must be outside public street right-of-way.1 per projectNot listedUnlockSec. 36-823(5), Table 18.6
Garage Sale / Estate Sale SignNot listed6 sq. ft.Must be outside public street right-of-way.1 per premisesOn-premises only, entirely on private property.UnlockSec. 36-823(6), Table 18.6
Vending Machine/Gas Pump/Ice Container SignsNot listed2 sq. ft.Not listed1 per machineOn vending machine, gas pump, or ice container.UnlockSec. 36-823(9)-(10), Table 18.6
Identification of Residential Community6 ft.24 sq. ft.Not listed1 per entranceOne per vehicular entrance.UnlockSec. 36-823(13), Table 18.6
Temporary Real Estate Sign6 ft.6 sq. ft.Not listed1 per street frontageOne per parcel for each public street frontage.UnlockSec. 36-823(15), Table 18.6

Central Business District (CBD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary Sandwich Board Sign42 in12 sq. ft.30 inNot listed1 per public entranceAt public entrance, on private property or public sidewalk, adjacent to building wall or curb.UnlockSec. 36-825(9), Table 18.6
Wall SignNot listedNot listedNot to exceed 90% of building facade width (general standard)Not listed1 per businessFlat against building facade.UnlockTable 18.6, Sec. 36-825(4), Sec. 36-828
Canopy SignNot listedNot listedNot to exceed 90% of building facade widthNot listed1 per businessOn canopy attached to building.UnlockTable 18.6, Sec. 36-825(4), Sec. 36-828
Projecting/Canopy SignNot listed12 sq. ft.Not listed2 ft from street curbline; cannot project more than 6 ft over public right-of-way.1 per businessOn building exterior, projects outward.UnlockTable 18.6, Sec. 36-825(6), Sec. 36-828
Hanging SignNot listed6 sq. ft.Not listedNot listedNot listedOn face or underside of canopy.UnlockSec. 36-825(5), Table 18.6
Directional Sign4 ft.4 sq. ft.Not listedNot listed1 per drivewayAt approved drivewayUnlockTable 18.6, Sec. 36-825(7)
Pylon or Ground Sign - Typical Site4 ft.12 sq. ft.Not listedNot listed1 per lotNot listedUnlockTable 18.6, Footnote 3, Sec. 36-825(12), (13)
Pylon or Ground Sign - Gateway Site6 ft.20 sq. ft.Not listedNot listed1 per street frontageNot listedUnlockTable 18.6, Footnote 3, Sec. 36-825(12)

General Business District (GBD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignNot listed100 sq. ft.Not to exceed 90% width of facadeNot listed1 per businessNot listedUnlockTable 18.6, Sec. 36-825(4), (13), Sec. 36-828
Canopy SignNot listedNot listedNot to exceed 90% width of facadeNot listed1 per businessOn canopy attached to building.UnlockTable 18.6, Sec. 36-825(4)
Projecting SignNot listed34 sq. ft.Not listedAt least 6 ft from public right-of-way.1 per businessOn building exterior, projects outward.UnlockTable 18.6, Sec. 36-825(6)
Directional Sign4 ft.4 sq. ft.Not listedNot listed1 per drivewayAt approved drivewayUnlockTable 18.6, Sec. 36-825(7)
Pylon or Ground Sign - General15 ft.40 sq. ft.Not listedNot listed1 per lotNot listedUnlockTable 18.6, Sec. 36-825(12), (Footnote 4)
Pylon Sign (Multi-tenant Business Center)15 ft.50 sq. ft.Not listedNot listed1 per lotNot listedUnlockTable 18.6, Footnote 4
Sandwich Board Sign36 in.6 sq. ft.24 in.Not listed1 per businessNext to building or within 10 ft of right-of-wayUnlockSec. 36-825(10), Table 18.6
Sandwich Board Sign (Special Event Temporary Sign)36 in.6 sq. ft.24 in.Not listed1 per business (special event)Next to building or within 10 ft of right-of-wayUnlockSec. 36-825(11), Table 18.6

PermitPal covers all 6 zoning districts in Goodrich. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Goodrich

  • Signs which obstruct free access or egress from any building.
  • Signs which in any way simulate or could be confused with the lighting of emergency vehicles or traffic signals.
  • Signs which obstruct or impair the vision of motorists or nonmotorized travelers at any intersection, driveway, within a parking lot or loading area.
  • Signs having moving members or parts, or using high intensity or flashing lights, spinners or animated devices.
  • Nonregulatory signs placed in any public right-of-way, attached to a utility pole or affixed to a tree.
  • Portable signs, as defined, unless otherwise provided for in this chapter.

Exempt Signs in Goodrich

  • Nameplate: address, owner or occupant nameplate and other signs of up to two square feet in area attached to a mailbox, light fixture or an exterior wall.
  • Integral signs: names of buildings, dates of erection, monumental citations, commemorative tablets when carved into stone, concrete or similar material.
  • Home occupation identification sign: provided that it is a legal home occupation in a residential district, there is only one sign per parcel, attached to an exterior building wall and does not exceed one square foot in area.
  • Permanent signs of a religious institution, school, museum, library, community recreation facility or other nonprofit organization/institutional bulletin boards that are permanent signs which do not exceed 25 square feet in area, are a maximum of six feet in height, and meet the illumination standards of this chapter.
  • Construction signs: only one such sign per development project; with a maximum height of six feet; not exceeding 16 square feet in area and erected during the construction period only and removed within 14 days of the date an occupancy permit is issued.
  • Garage sale and estate sale signs: only one sign per premises; on-premises only and entirely on private property; do not exceed six square feet in area; erected no more than ten business days before and removed within one business day after the announced sale.
  • Historical marker: plaques or signs describing state or national designation as an historic site or structure and/or containing narrative, not exceeding 12 square feet in area.
  • Signs not exceeding a total of two square feet per business indicating acceptance of credit cards or describing business affiliations and attached to a permitted sign, exterior wall, building entrance or window.
  • Signs on vending machines, gas pumps, and ice containers indicating the contents, provided the sign on each device does not exceed two square feet in area.
  • Signs atop gasoline service station pumps announcing on-premises sales, not exceeding two square feet in area and signs on gas station pump islands or their structural supports identifying "self-serve" and "full-serve" operations.
  • Noncommercial signs: signs containing noncommercial messages, such as those designating the location of public telephones, restrooms, restrictions on smoking and restrictions on building entrances, provided such signs do not exceed two square feet in area.
  • Flags or insignia of any nation, state, the village, community organization, educational institution, noncommercial enterprise, college or university.
  • Identification of residential community: one permanent sign per vehicular entrance identifying residential developments such as subdivisions, apartment complexes, condominium communities, senior housing complexes, mobile home parks and similar uses, with a maximum height of six feet and not exceeding 24 square feet in area (unless integrally designed as part of an ornamental wall).
  • Political signs: provided that the property contains an occupied structure, signs are not placed within the public street right-of-way, and signs are spaced at least ten feet apart.
  • Real estate signs: one per parcel for each public street frontage, maximum height six feet, not exceeding six square feet in area within residential districts, 12 square feet in area for all other districts, and must be removed within five days of occupancy by purchaser or lessee.
  • Regulatory, directional and street signs erected by a public agency in compliance with Michigan Manual of Uniform Traffic Control Devices Manual.
  • Window signs within the building, provided such signs do not occupy more than 50 percent of the window area and the clear window portion is located to allow security monitoring from the street.
  • Warning signs, such as no trespassing, warning of electrical currents or animals, provided such signs do not exceed two square feet in area.

Sign Plan & Submission Notes for Goodrich

  • No regulated sign shall be erected or altered until approved by the zoning administrator and until a permit has been issued.
  • Sign permits shall be obtained from the village prior to the erection or replacement of any regulated sign.
  • Applications for sign permits shall be submitted to the village administrator for review. Permits issued following zoning administrator and building official approval and inspection.
  • A special event sandwich board sign in the general business district requires a special event sign permit from the zoning administrator.

Source: municode municipal code

Frequently Asked Questions

In Goodrich, the height limit for Pylon or Ground Sign - General in the General Business District (GBD) is 15 ft. Maximum sign heights range from 4 ft to 42 in across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Goodrich require a permit. From the submission notes on this page: Applications for sign permits shall be submitted to the village administrator for review. Permits issued following zoning administrator and building official approval and inspection. Run a code check for an exact address to see the permit requirements for that zone.

Goodrich's sign code covers 32 sign types, including Wall Sign, Canopy Sign, Directional Sign, and Projecting Sign. Most commercial signs need a permit. The ordinance lists 18 exemptions. One of them: Construction signs: only one such sign per development project; with a maximum height of six feet; not exceeding 16 square feet in area and erected during the construction period only and removed within 14 days of the date an occupancy permit is issued. The full list is on this page.

In Goodrich, Projecting Sign in the General Business District (GBD) must be set back at least 6 ft from public right-of-way. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Goodrich's sign ordinance that cover digital, changing, or flashing signs: Signs having moving members or parts, or using high intensity or flashing lights, spinners or animated devices. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Goodrich Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Goodrich, Michigan, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds