Sign Regulations in Royal Oak, Michigan

Royal Oak, Michigan has specific sign regulations covering 18 sign types across 4 zoning districts. Regulated sign types include Wall Sign, Window Sign, Monument Sign. Height restrictions apply. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 21, 2025

Sign Regulation Overview for Royal Oak, Michigan

Sample Sign Requirements in Royal Oak

Sign TypeMax HeightMax AreaSetback
Wall Sign100 sq ft
Monument Sign5 ft; may be increased by 1 ft if certain requirements are met30 sq ft (one face)/60 sq ft (two or more faces); may be increased by 6 sq ft (one face)/12 sq ft (two or more faces) if certain requirements are met10 ft minimum setback
Freestanding Sign or Monument Sign16 ft (may be increased to 24 ft if frontage >300 ft and area increased)42 sq ft (one face)/84 sq ft (two or more faces). May be increased up to 84 sq ft/168 sq ft if lot frontage >300 ft, and height up to 24 ft.

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Royal OakPartial Coverage

Sign Types Covered

18

  • Wall Sign
  • Window Sign
  • Monument Sign
  • Freestanding Sign or Monument Sign
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Height restrictions
  • Illumination rules

Official Resources for Royal Oak

Municipal Code3 permit application links available

Frequently Asked Questions

In Royal Oak, monument signs are limited to 5 ft; may be increased by 1 ft if certain requirements are met. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Royal Oak, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Royal Oak, regulated sign types include Wall Sign, Window Sign, Monument Sign, Freestanding Sign or Monument Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Royal Oak, monument signs typically require a 10 ft minimum setback setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Royal Oak are regulated with specific requirements for brightness, animation, and message duration. Royal Oak has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Royal Oak Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Royal Oak, Michigan sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Royal Oak, Michigan Sign Rules at a Glance

Royal Oak, Michigan regulates 18 sign types across 4 zoning districts. Institutional Use - Monument Signs in the General Regulations For All Zones zoning district are capped at 5 ft tall and 25 sq ft (single face) / 50 sq ft (multiple faces), with a 10 ft minimum setback setback (Sec. § 607-8D(2)).

Detailed Sign Ordinance Requirements for Royal Oak, Michigan

Sign Rules by Zoning District in Royal Oak (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Sign Area 125 ft; may be increased by 1 ft if certain requirements are met100 sq ft
Sign Area 2416 ft (may be increased to 24 ft if frontage >300 ft and area increased)100 sq ft
Sign Area 34Bottom at least 8 ft above adjacent right-of-way; top not above 12 ft above adjacent right-of-way100 sq ft
General Regulations For All Zones11No part lower than 8 ft or higher than 15 ft above sidewalk30 sq ft per building facade

Zone-by-Zone Sign Requirements in Royal Oak(sample of 3 of 4 zones)

Sign Area 2

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign100 sq ftOne wall sign per building facadeBuilding facadesUnlock§ 607-6A
Freestanding Sign or Monument Sign16 ft (may be increased to 24 ft if frontage >300 ft and area increased)42 sq ft (one face)/84 sq ft (two or more faces). May be increased up to 84 sq ft/168 sq ft if lot frontage >300 ft, and height up to 24 ft.1 per lot (may increase with lot frontage), or increase size/height of one signOn lotUnlock§ 607-6B
Window Sign15% of each window areaOne per windowWithin 12 inches of window or on window pane, visible from exteriorUnlock§ 607-6C
Electronic Message CenterUp to half of allowed freestanding sign areaSame as permitted freestanding sign(s)Freestanding sign onlyUnlock§ 607-6D

Sign Area 3

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign100 sq ftOne wall sign per building facadeBuilding facadesUnlock§ 607-7A
Projecting SignBottom at least 8 ft above adjacent right-of-way; top not above 12 ft above adjacent right-of-way4 sq ft background area; optional supplemental sign (0.5 sq ft)Affixed via support arm(s) to building façade, downtown pedestrian-orientedUnlock§ 607-7B
Window Sign10% of each window areaOne per windowWithin 12 inches of window or on window pane, visible from exteriorUnlock§ 607-7C
Sidewalk SignPrivate property (per specifications) or public property (license agreement required)Unlock§ 607-7D

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Building Marker30 sq ft per building facadeBuilding facadeUnlock§ 607-8B
FlagLimited by wind load capacity of pole/structure as determined by Building OfficialPole or structure, constructed per Building CodeUnlock§ 607-8C
Institutional Use - Wall Sign20 sq ft per building facade fronting on a streetEach facade fronting on a streetUnlock§ 607-8D(1)
Institutional Use - Monument Sign5 ft25 sq ft (single face) / 50 sq ft (multiple faces)10 ft minimum setbackOne per lotFrontage on major street; must be oriented toward major streetUnlock§ 607-8D(2)
Multiple-Family Residential - Wall Sign2 sq ft per dwelling unit, max 20 sq ftOne per frontage on major streetPer frontage on major street, oriented toward major streetUnlock§ 607-8E(1)
Multiple-Family Residential - Monument Sign5 ft25 sq ft (single face) / 50 sq ft (multiple faces)10 ft minimum setbackOne per developmentFrontage on major street; must be oriented toward major streetUnlock§ 607-8E(2)
PennantNo part lower than 8 ft or higher than 15 ft above sidewalk9 sq ftOne per 10 ft major street frontage, max 6 per lotAffixed to building facadeUnlock§ 607-8F
Private Traffic Direction Sign/Incidental Sign3 ft (if freestanding)5 sq ftOn lot; horizontal directional signs flush with paved areas are exemptUnlock§ 607-8G

PermitPal covers all 4 zoning districts in Royal Oak — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 4 zones for Royal Oak — start free

Prohibited Signs in Royal Oak

  • A sign not expressly permitted is prohibited.
  • Signs which incorporate, in any manner, flashing or moving lights, except as otherwise permitted in this chapter.
  • Banners, spinners, and streamers.
  • String lights, except seasonal decorative displays.
  • Any sign which has any visible moving part, visible revolving part, or visible mechanical movement of any description, or other apparent visible movement, including intermittent electrical pulsations, or by action of normal wind currents. Automatic change-of-message with cycle time of less than 30 seconds is expressly prohibited.
  • Roof signs.
  • Beacons, except as may be authorized by a special event permit.
  • Signs projecting over or located in the public right-of-way, other than as may be permitted in Sign Area 3.
  • Portable signs, except as otherwise permitted in this chapter.
  • Any sign or sign structure which is structurally unsafe, constitutes a hazard to safety or health by reason of inadequate maintenance, dilapidation or abandonment, is not kept in good repair, or is capable of causing electrical shocks to persons likely to come in contact with it.
  • Any sign which, by reason of its size, location, color, or manner of illumination, constitutes a traffic hazard or detracts from the visibility of any traffic sign or control device on public streets.
  • Any sign which obstructs free ingress to or egress from a door, window, fire escape or other exitway.
  • Any sign or other advertising structure containing any obscene message, pursuant to state statute.
  • Any sign unlawfully installed, erected or maintained.
  • Any sign painted upon the wall of a building, fence or screening wall.
  • Any sign which is attached to a tree, utility pole or other structure not intended to support a sign as defined in this chapter.
  • Inflatable signs and tethered balloons.
  • Lighting used as a permanent architectural detail or enhancement surrounding windows and doors, including, but not limited to, unshielded luminous tubes (i.e., neon or argon lights), fluorescent light fixtures, fiber-optic lights, light-emitting diodes, or bare light bulbs, except seasonal decorative displays.
  • No person shall paste, glue, tack or otherwise post any sign, placard, advertisement, or inscription whatsoever, nor shall any person erect or cause to be erected any sign whatever in any park, except for licensed concessionaires acting with proper authority.
  • No person, firm or corporation shall fasten any cards, signs, posters, boards, or other articles to any tree, shrub or plant growing upon any public highway, park or other public building in the City of Royal Oak.

Exempt Signs in Royal Oak

  • Building or house address signs, provided they are displayed and clearly visible from the street and placed in accordance with the City's Property Maintenance Code.
  • Building markers, not exceeding an area of 30 square feet on each building facade.
  • Flags, as defined, provided their size does not exceed the wind load capacity of the pole or other anchoring structure and all structures comply with the Building Code.
  • Signs of a public nature, including safety signs, danger signs, trespassing signs, traffic signs, signs indicating scenic or historical points of interest, memorial plaques, and all signs erected by or on order of a public officer in the performance of a public duty.
  • Private traffic direction signs and other incidental signs provided certain size and height restrictions are met.
  • Temporary signs, including but not limited to signs advertising property currently for sale or lease, on-going garage or estate sales, and political signs.
  • Underground public utility warning signs marking the routes of underground public utility pipes, conduits, and cables.
  • Vehicle signs painted on or attached to vehicles which are licensed and used upon public streets for transportation of persons, goods or equipment.
  • Horizontal directional signs flush with paved areas are exempt from directional sign standards.
  • Seasonal decorative displays are specifically not considered as prohibited string lights or certain lighting details.

Sign Plan & Submission Notes for Royal Oak

  • A master signage plan shall be submitted to the Planning Department whenever a building or structure shall be erected, converted to other use or structurally altered so as to require site plan review pursuant to Chapter 770, Zoning. The master signage plan shall be subject to the review and approval of the Planning Commission in the course of its site plan review process.
  • As part of the application for a sign permit, a master signage plan as provided in § 607-12 must be submitted if required.
  • Flashing or moving lights, moving parts, or animation may be incorporated into a freestanding or monument sign in Sign Area 2 only when approved as part of a master signage plan by the Planning Commission for sites with frontage along Woodward Avenue.
  • Variances from the provisions of the sign ordinance may be granted by the Planning Commission through an appeal and hearing process, upon evidence of unnecessary hardship or practical difficulties as specified in the ordinance.

Source: ecode360 municipal code