Carver, Minnesota has specific sign regulations covering 17 sign types across 6 zoning districts. Regulated sign types include Monument Sign, Rear Door Sign, Under-Canopy Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 7, 2025

Sign Regulation Overview for Carver, Minnesota

Sample Sign Requirements in Carver

Sign TypeMax HeightMax AreaSetback
Monument Sign10 ft30 sq ftAt least 5 ft from public right-of-way or structure setback
Wall Sign or Canopy Sign80 sq ft or 10% of wall area, whichever is lessNo wall sign shall extend further than within 1 ft of the curb
Rear Door Sign4 sq ft

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for CarverFull Coverage

Sign Types Covered

17

  • Monument Sign
  • Rear Door Sign
  • Under-Canopy Sign
  • Wall Sign or Canopy Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Carver

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Carver, monument signs are limited to 10 ft. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Carver, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Carver, regulated sign types include Monument Sign, Rear Door Sign, Under-Canopy Sign, Wall Sign or Canopy Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Carver, monument signs typically require a At least 5 ft from public right-of-way or structure setback setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Carver are regulated with specific requirements for brightness, animation, and message duration. Carver has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Carver Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Carver, Minnesota sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Carver, Minnesota Sign Rules at a Glance

Carver, Minnesota regulates 17 sign types across 6 zoning districts. Monument Signs in the Central business district (CBD) zoning district are capped at 10 ft tall and 30 sq ft, with a At least 5 ft from public right-of-way or structure setback setback (Sec. Sec. 50-93(8)A.1). Most commercial signs in Carver require a permit.

Detailed Sign Ordinance Requirements for Carver, Minnesota

Sign Rules by Zoning District in Carver (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Central business district (CBD)410 ft80 sq ft or 10% of wall area, whichever is less
General commercial (GC), Freeway commercial (FC)720 to 50 ft depending on lot size/frontageVariable; up to 275 sq ft maximum on large walls
Industrial district (I-1)410 ft64 sq ft
Agriculture (A-1), Low density residence (R-1), Low density residence unsewered (RUS-1), Medium density residence (R-2)110 ft32 sq ft
Public institutional (P/I), Public open space (P)1
General Regulations For All Zones3Flag: 50 ft (non-res.), 25 ft or height of principal structure (residential); Free-standing: 4 ft; Traffic: 5 ftWindow signs: Max 50% of window area; non-governmental traffic signs: 4 sq ft; free-standing yard sign: 12 sq ft, 4 ft high

Zone-by-Zone Sign Requirements in Carver(sample of 3 of 6 zones)

Central business district (CBD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Monument Sign10 ft30 sq ftAt least 5 ft from public right-of-way or structure setback1 per lot/building padOne per zoning lot or separate building pad with street frontage, at least 5 ft from public right-of-way or existing structure setbackUnlockSec. 50-93(8)A.1
Wall Sign or Canopy Sign80 sq ft or 10% of wall area, whichever is lessNo wall sign shall extend further than within 1 ft of the curbBuilding facade (street frontage)UnlockSec. 50-93(8)A.2
Rear Door Sign4 sq ft1 per rear or side doorOne per rear or side door, on the doorUnlockSec. 50-93(8)A.3
Under-Canopy Sign6 sq ft1 per tenantPer tenant, perpendicular to wall, uniform heightUnlockSec. 50-93(8)A.4

General commercial (GC), Freeway commercial (FC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
TH212 Frontage Monument Sign20 to 50 ft depending on lot size/frontage120 sq ft to 480 sq ft depending on lot size/frontage40 ft from TH 212 right-of-way and 40 ft from adjacent property line; not greater than 100 ft from right-of-way1 per zone lot with required frontageOne per zone lot with TH 212 frontage as part of PCD, instead of the monument sign; minimum setback 40 ft from TH 212 right-of-way and 40 ft from adjacent property lineUnlockSec. 50-93(8)B.1
Monument Sign10 ft80 sq ftAt least 10 ft from any property line1 per zoning lotOne per zoning lot with street frontage, at least 10 ft from any property lineUnlockSec. 50-93(8)B.2
Wall Sign or Canopy Sign (Structure > 100,000 sq ft)Varies (per PCD approval)Per PCD approvalOn building facade(s) as per site planUnlockSec. 50-93(8)B.3.a
Wall Sign or Canopy Sign (Structure < 100,000 sq ft)Variable; up to 275 sq ft maximum on large wallsOn street frontage and entrance façade; canopy signs may substitute for wall signs.UnlockSec. 50-93(8)B.3.b
Menu Board (Drive through)8 ft45 sq ft1 per drive throughDrive through facilityUnlockSec. 50-93(8)B.4
Rear Door Sign4 sq ft1 per rear/side doorOne per rear or side door; on the doorUnlockSec. 50-93(8)B.5
Under-Canopy Sign6 sq ft1 per tenantPer tenant; extends perpendicular to wall; at uniform heightUnlockSec. 50-93(8)B.6

Industrial district (I-1)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Monument Sign (Primary)10 ft64 sq ftAt least 20 ft from public right-of-way of entrance streetMax 2 per entranceAt entrance(s) from public right-of-way; not within 20 ft of right-of-wayUnlockSec. 50-93(8)C.1.a
Monument Sign (Secondary)8 ft32 sq ft1 per structureAt each structure in industrial/office parkUnlockSec. 50-93(8)C.1.b
Wall Sign (Structures with 3+ stories)48 sq ft1 per right-of-way frontageAt top of structure, per right-of-way frontageUnlockSec. 50-93(8)C.2
Door or Wall Sign (Per Tenant)4 sq ft1 per tenantOn the door or immediately adjacent wall to the tenant's suiteUnlockSec. 50-93(8)C.3

PermitPal covers all 6 zoning districts in Carver — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Carver — start free

Prohibited Signs in Carver

  • It shall be unlawful for any person to erect, construct, enlarge, move, alter or convert any sign or cause the same to be done within the city except in accordance with the provisions of this Ordinance.
  • Except as specifically exempted from the provisions of section 50-93, it shall be unlawful for any person to post, display, substantially change, or erect a sign without a permit.
  • No sign or sign structure shall be erected, altered, rebuilt or relocated until a permit has first been issued by the city, except as provided in subdivision (5) of section 50-93.
  • All signs not expressly authorized by this Ordinance are prohibited.
  • Temporary signs that are not in compliance with subdivision (8)C are prohibited.
  • Roof signs including signs mounted on a roof surface or projecting above the roof line of a structure if either attached to the structure or cantilevered over the structure are prohibited.
  • Signs with dynamic displays, except those allowed under subdivision (8)F, are prohibited.
  • Swinging signs are prohibited.
  • Rotating signs are prohibited.
  • Pylon signs are prohibited.
  • Animated signs, flashing signs, and intensely lit signs are prohibited, except changing signs as allowed.
  • Signs designed to resemble official traffic signs, except signs used to control traffic on private property, are prohibited.
  • Signs painted on or attached to any courtesy bench, trash can, or similar object used for advertising are prohibited.
  • Window signs which exceed 50 percent of the window area are prohibited.
  • Wind-activated devices other than flags and banners are prohibited.
  • A-frame signs, sandwich board, sidewalk, or curb signs are prohibited when placement makes a location inaccessible under the Americans with Disabilities Act.
  • Signs attached or painted onto equipment, such as semi-truck trailers, where signing is a principal use of the equipment, are prohibited.
  • Signs painted on or attached to utility poles, trees, rocks, or other similar objects are prohibited.
  • Signs that obstruct a fire escape, required exit, window or door opening used as a means of ingress or egress, or interfere with any opening required for ventilation, or which violate any city code including Life Safety Code and Fire Prevention Code, are prohibited.
  • Signs occupying a parking space required under minimum parking requirements, other than signs designating the space reserved for handicapped or other use, are prohibited.
  • Signs which do not conform to city-adopted building and electrical codes are prohibited.
  • Signs which emit audible sound, odor or visible matter are prohibited.
  • Signs set back less than ten feet from the curb of any street or located in roadway medians, except within the central business district, are prohibited.
  • Signs attached to any street signs or signs directing or controlling traffic, or any sign attached to a pole supporting such signs, are prohibited.
  • Signs projected onto a structure are prohibited.
  • Signs within public right-of-way except for official traffic signs or publicly owned/maintained signs are prohibited. Sandwich board signs within the central business district zoning district are excluded from this prohibition with conditions.
  • Signs in violation of any zoning overlay district or historic district rules and regulations are prohibited.
  • Any sign constructed of non-durable material, including but not limited to paper, cardboard, or flexible plastic, displayed more than 60 days and showing weather damage is prohibited.
  • Abandoned signs are prohibited; signs are deemed abandoned if the business, service, event, or principal use on the zoning lot has been discontinued for six months.
  • Any sign that is structurally unsound or a hazard to traffic or pedestrians is prohibited.
  • Dilapidated or neglected signs are prohibited.
  • Billboard signs are prohibited.
  • Signs in any area designated as an undisturbed buffer by law, zoning, or plat are prohibited.

Exempt Signs in Carver

  • Signs in compliance with the Fair Campaign Practices Act (M.S.A. § 211.B.045) are exempt from permit requirements.
  • Non-governmental traffic control devices that do not contain commercial messages and are not larger than four square feet and not more than five feet in height are exempt from permit requirements, provided placement does not adversely affect adjacent properties or site lines.
  • One non-illuminated free-standing sign per property having an aggregate sign area of not more than 12 square feet, not exceeding four feet in height or set back less than ten feet from the public right-of-way, is exempt from permit requirements.
  • Signs for the sole purpose of displaying street numbers as required by ordinance, provided said numbers do not exceed 12 inches in height unless approved, are exempt from permit requirements.
  • Flags meeting height restrictions and proportional size limits (as per ordinance) are exempt from permit requirements, with a limit of three flag poles and a maximum of two flags per pole per zoning lot.
  • Window signs installed for viewing from outside the premises, not exceeding 50 percent of the available window space, are exempt from permit requirements.
  • Temporary outdoor advertising in compliance with subdivision (8)C is exempt from permit requirements.
  • Signs in the public institutional (P/I) or public open space (P) districts are exempt from permit requirements.
  • Public notice signs, traffic control devices, or other official government signs when posted by a government officer in the course of their duties are exempt from permit requirements.

Sign Plan & Submission Notes for Carver

  • A site plan to scale showing the location of zoning lot lines, structures, parking areas, existing and proposed signs, and any other physical features is required as part of every sign permit application.
  • For free-standing and monument signs, dimensioned sign location on the site plan and structural foundation and mounting details must be included in the sign permit application. Indicate the location and size of all existing free-standing and monument signs on the property.
  • Monument (subdivision) signs in residential districts shall be reviewed with preliminary plat approval; ongoing ownership and maintenance of the sign shall be specified as a condition of approval.
  • Signage for properties under jurisdiction of the Carver Heritage Preservation Commission (HPC) must be approved by the HPC before a sign permit will be issued, except for banner and temporary signs.
  • Wall signs for commercial structures exceeding 100,000 square feet must be approved as part of the planned commercial development (PCD) process and may vary from standard wall sign requirements; approved wall signs shall be as shown on the approved site plans for the PCD.

Source: municode municipal code