Mounds View, Minnesota has specific sign regulations covering 21 sign types across 7 zoning districts. Regulated sign types include Construction Sign, Directional Sign, Statue. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 20, 2025

Sign Regulation Overview for Mounds View, Minnesota

Sample Sign Requirements in Mounds View

Sign TypeMax HeightMax AreaSetback
Construction Sign8 sq ft
Directional SignNo
Statue16 ft at ground level / 10 ft above roof100 sq ftSame as ground sign setbacks

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Mounds ViewFull Coverage

Sign Types Covered

21

  • Construction Sign
  • Directional Sign
  • Statue
  • Identification Sign
  • +2 more types

Zoning Districts

7

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

Sign height limits in Mounds View vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Mounds View, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Mounds View, regulated sign types include Construction Sign, Directional Sign, Statue, Identification Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Mounds View vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Mounds View are regulated with specific requirements for brightness, animation, and message duration. Mounds View has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Mounds View Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Mounds View, Minnesota sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Mounds View, Minnesota Sign Rules at a Glance

Mounds View, Minnesota regulates 21 sign types across 7 zoning districts. Ground Signs in the B-1 zoning district are capped at 16 ft tall and 100 sq ft per side, two sides max, with a 3 ft to building (unless parallel), 15 ft to perimeter lot line; not within 30-ft sight triangle setback (Sec. § 161.037(B) (Sign Table), § 161.037(C) (Sign Height Table), § 161.038(A)). Most commercial signs in Mounds View require a permit.

Detailed Sign Ordinance Requirements for Mounds View, Minnesota

Sign Rules by Zoning District in Mounds View (7 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
R-1, R-2916 ft at ground level / 10 ft above roof100 sq ft
R-3, R-41016 ft at ground level / 10 ft above roof100 sq ft
R-51116 ft at ground level / 10 ft above roof100 sq ft
B-11116 ft100 sq ft per side, two sides max
B-2, B-3, B-4, I-1, CRP1516 ft per table (see note (3); billboard in some locations: 45 ft)100 sq ft
PUD1As allowed by PUD Narrative. If no document, per B-3 (16 ft ground signs, 300 sq ft wall signs, etc.)As allowed by PUD Narrative. If no document, per B-3 (see above for B-3 limits)
General Regulations For All Zones345 ft (County Rd 10/I-35W: 35 ft)Up to 700 sq ft per side, max extensions 25% area (subject to special locations and interim use permit)

Zone-by-Zone Sign Requirements in Mounds View(sample of 3 of 7 zones)

R-5

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Construction Sign8 sq ftUnlock§ 161.037(B) (Sign Table)
Directional Sign4 sq ftUnlock§ 161.037(B) (Sign Table); Directional***
Ground Sign8 ft32 sq ft per side, up to 2 sidesSee setbacks for ground signs.Unlock§ 161.037(C), § 161.038(A), § 161.037(B) (Sign Table)
Statue16 ft at ground level / 10 ft above roof100 sq ftSame as ground sign setbacks.Ground or attached to building. Setbacks as ground signs.Unlock§ 161.038(I)
Home Occupation Sign1 sq ftAffixed to house or garage on the propertyUnlock§ 161.037(B) (Sign Table); § 161.038(G)
Identification Sign2 sq ftUnlock§ 161.037(B) (Sign Table)
Real Estate Sign10 sq ftOn property for sale/leaseUnlock§ 161.037(B) (Sign Table), § 161.020(B)(1)
Wall Sign64 sq ft (per building)On exterior wallUnlock§ 161.037(B) (Sign Table); § 161.038(B)(3)

B-1

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Construction Sign32 sq ftUnlock§ 161.037(B) (Sign Table)
Directional Sign4 sq ftUnlock§ 161.037(B) (Sign Table); Directional***
Ground Sign16 ft100 sq ft per side, two sides max3 ft to building (unless parallel), 15 ft to perimeter lot line; not within 30-ft sight triangleSee § 161.038(A)(6) for multiple street frontagesUnlock§ 161.037(B) (Sign Table), § 161.037(C) (Sign Height Table), § 161.038(A)
Statue16 ft at grade / 10 ft above roof100 sq ftSame as ground signsOn ground or attached to building as with ground sign setbacks.Unlock§ 161.038(I)
Identification Sign4 sq ftUnlock§ 161.037(B) (Sign Table)
Incidental Sign1 sq ftUnlock§ 161.037(B) (Sign Table)
Real Estate Sign32 sq ftOn property for sale/leaseUnlock§ 161.037(B) (Sign Table), § 161.020(B)(1)
Wall Sign and Projected Sign (Combined Area)100 sq ft (area aggregate for wall, ground, projection signs combined)On exterior wall or projection per code.Unlock§ 161.037(B) (Sign Table), § 161.038(B)(4)

B-2, B-3, B-4, I-1, CRP

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Drive-thru Menu Board - Primary36 sq ft (max 2 primary)Maximum two primaryUnlock§ 161.037(B) (Sign Table)
Drive-thru Menu Board - Secondary15 sq ft (max 2 secondary)Maximum two secondaryUnlock§ 161.037(B) (Sign Table)
Ground Sign16 ft per table (see note (3); billboard in some locations: 45 ft)B-2: 200 sq ft; B-3: 200 sq ft; B-4: 200 sq ft; I-1: 200 sq ft; CRP: 100 sq ft3 ft to building (unless parallel), 15 ft to perimeter lot line; not within 30-ft sight triangle. County Rd 10: 5-ft setback.See § 161.038(A)(6) for multiple signs criteriaUnlock§ 161.037(B), § 161.037(C), § 161.038(A),(I)
Statue16 ft100 sq ftSame as ground signsUnlock§ 161.038(I)
Projection Sign10 ft above roof/parapetIncluded in wall sign areaPerpendicular to building wall, not over public ROW; may project over private sidewalk.Unlock§ 161.038(C)
Real Estate Sign32 sq ft (B-2/3/4/CRP); 64 sq ft (I-1)On property for sale/leaseUnlock§ 161.037(B) (Sign Table), § 161.020(B)(1)
Wall Sign100 sq ft (B-2); 300 sq ft (B-3, B-4, I-1); wall sign area per building occupant (B-2-4/I-1); CRP - no wall signOn exterior building wallUnlock§ 161.037(B) (Sign Table), § 161.038(B)
Dynamic Display SignMax 50 sq ftSame as sign typePermitted only in B-2, B-3, B-4, I-1, PUDUnlock§ 161.038(H)(2),(3)

PermitPal covers all 7 zoning districts in Mounds View — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 7 zones for Mounds View — start free

Prohibited Signs in Mounds View

  • It is unlawful to install, construct, erect, alter, revise, reconstruct or relocate any outdoor sign or structure without first obtaining a permit, except as otherwise provided.
  • No sign shall be so located as to obscure or tend to obscure any existing sign.
  • No sign structure shall be attached or placed upon any building in such a manner as to obstruct any fire escape or any window or door nor shall any sign structure be attached to a fire escape.
  • No swinging sign shall be erected or hung on or attached to any building within the city, and existing swinging signs deemed unsafe by the Building Inspector must be removed or brought into compliance.
  • All illuminated signs shall have a shielded light source and no sign may display light sources directly visible to pedestrians or operators of motor vehicles.
  • No sign shall display matter that has been deemed obscene by a court of competent jurisdiction.
  • No sign shall have moving sections or intermittent, blinking or flashing lights, except for government signs and signs with dynamic displays as allowed in the ordinance.
  • No sign shall be brighter than necessary for clear visibility and must adhere to specified luminance limits.
  • No sign shall interfere with the functioning of a traffic sign, signal, or constitute a traffic hazard.
  • No temporary or permanent signs are allowed within public rights-of-way, except for directional signs and those expressly allowed.
  • Flashing signs, beacons, and searchlights are prohibited.
  • Vehicles or trailers used as signs are prohibited, except for magnetic, decal, or permanently painted signs that do not obscure windows or alter vehicle silhouette.
  • Roof signs are prohibited unless integrally incorporated into the roof design (then considered projection signs).
  • Billboards are prohibited, except as otherwise provided.
  • Nuisance signs (including those in a state of disrepair or in violation) are prohibited.
  • Signs or lights that mimic or appear similar to emergency vehicles or traffic-control lights are prohibited.
  • Signs with blinking, flashing or fluttering lights are prohibited.
  • No sign shall be designed, located, or maintained to obscure, conceal, or cause confusion as to any traffic-control sign or device.
  • No sign shall be located or maintained on or over any public street or highway right-of-way unless specifically permitted.
  • There shall be no use of revolving beacons, zip flashers, flashing signs or similar devices that would distract automobile or motor vehicle traffic to constitute a safety hazard.

Exempt Signs in Mounds View

  • Permits are not required for any sign less than or equal to eight square feet in area (excluding temporary signs), provided all other requirements are satisfied.
  • Permits are not required for signs pertaining only to the sale, rental or lease of the premises upon which displayed.
  • Permits are not required for signs on residential property stating only the name or identity of the occupant.
  • Permits are not required for construction signs or contractor signs, provided the sign is removed immediately upon completion of the work.
  • Permits are not required for home occupation signs and incidental residential signs.
  • Permits are not required for national, state, regional, local, institutional or cultural flags.
  • Permits are not required for advertising on a transit bench or within a transit shelter or enclosure.
  • Permits are not required for official notices authorized by a court, public body, or public safety official.
  • Permits are not required for government signs (including traffic-control, identification, informational, danger, and official city event signs).
  • Permits are not required for flag or pennant stringers.
  • Permits are not required for sandwich boards not exceeding eight square feet and ground signs not exceeding four square feet that are located within 15 feet of the business advertised.
  • Permits are not required for non-commercial signs (expression of opinion or viewpoint of a non-commercial nature), provided the sign is not illuminated and does not exceed nine square feet combined, and location restrictions for multi-unit properties are observed.
  • Window signs, as allowed, are exempt from permit requirements.

Sign Plan & Submission Notes for Mounds View

  • Sign permit applications require submission of detailed plans including position, elevations, distances, size, construction details, and specifications.
  • Permit applications must identify if the sign is illuminated, has moving/blinking lights, is single/double/multi-faced, has changeable copy, relates to on-premises activity, or has any dynamic display (including area and style).
  • Variance requests must include all information required for a sign permit application.
  • Conditional use permit (CUP) approval is required for dynamic display signs on the sites of schools, churches, places of worship, or institutional land uses.
  • For planned unit developments (PUDs), signage requirements may be established by the PUD Narrative document; if not, B-3 zoning district standards apply.
  • No master sign plan requirement is explicitly stated in the general provisions, but PUD and CUP processes may serve similar review purposes.
  • Variance (“sign variance”) requests, including those seeking relief from the requirements, require written application, applicable fees, and complete sign permit documentation.
  • The City Council may allow for placement of area identification signs and may require documentation, dedication of land for signage, and recorded maintenance agreements.