Sign Regulations in Stacy, Minnesota
Stacy, Minnesota has specific sign regulations covering 14 sign types across 6 zoning districts. Regulated sign types include Monument Sign, Temporary Sign, Window Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 20, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Stacy, Minnesota
Sample Sign Requirements in Stacy
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Changeable Message Sign | Not listed | 32 square feet | Setback of 10 feet from lot lines. |
| Monument Sign | 10 feet | 36 square feet | Setback of 10 feet from lot lines. |
| Temporary Sign | Not listed | 48 square feet | Setback of 10 feet from lot lines. |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
14
- Monument Sign
- Temporary Sign
- Window Sign
- Wall Sign
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Other Cities in Minnesota
Frequently Asked Questions
In Stacy, the height limit for Monument Sign in the Park District (P), Open Space District (OS) is 10 feet (Sec. 153.101(B)(2)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Stacy require a permit. From the submission notes on this page: A sign plan is required for all development complexes consisting of 3 or more tenant spaces in commercial areas. The plan shall be filed with the project application and processed concurrently. Run a code check for an exact address to see the permit requirements for that zone.
Stacy's sign code covers 14 sign types, including Monument Sign, Temporary Sign, Window Sign, and Wall Sign. Most commercial signs need a permit. The ordinance lists 22 exemptions. One of them: Interior signs. The full list is on this page.
In Stacy, Freestanding Sign in the Park District (P), Open Space District (OS) must be set back 10 feet from lot lines (Sec. 153.101(B)(2)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Stacy's sign ordinance that cover digital, changing, or flashing signs: Except where specifically permitted, any sign displaying moving parts, rotating, illuminated with flashing or intermittent lights, or any animated sign. (Clocks and barber poles are exempt.). Signs that blink, flash, or are animated by lighting in any fashion that would cause the appearance of traffic signs/lights or municipal vehicle warnings visible from the roadway. Animated signs, except flashing signs giving time, date, temperature, weather conditions, or similar public info. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Stacy Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Stacy, Minnesota, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Stacy, Minnesota Sign Rules at a Glance
Stacy, Minnesota regulates 14 sign types across 6 zoning districts. Monument Signs in the Park District (P), Open Space District (OS) are capped at 10 feet tall and 36 square feet, set back 10 feet from lot lines (Sec. 153.101(B)(2)). Most commercial signs in Stacy require a permit.
Detailed Sign Ordinance Requirements for Stacy, Minnesota
Sign Rules by Zoning District in Stacy (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Single Family Residential District (R1), One and Two Family Residential District (R2), Multiple Family Residential - Townhomes District (R-3A), Multiple Family Residential - Apartments District (R-3B), Manufactured Home Park District (R-M), Planned Unit Development (PUD), Rural Residential - I (RR-I), Rural Residential - II (RR-II) | 4 | 10 feet | 48 square feet | Not listed |
| Central Business District (CBD), General Business District (GB), Rural Transit Center (RTC), Light Industrial District (LI), Industrial District (I) | 11 | 10 feet | 80% of total awning size; printing limited to 30% of awning area | Not listed |
| Park District (P), Open Space District (OS) | 6 | 10 feet | 80% of the fence section the sign is affixed to | Not listed |
| Agriculture District (A), Rural Residential - Agriculture (RR-A) | 3 | 10 feet | 48 square feet | Not listed |
| Natural Resource Preservation (NRP) | 1 | Not listed | Not listed | Not listed |
| Shoreland District (SL), Sunrise Overlay District (SRO), Carlos Avery Overlay District (CAO), Rural Business Overlay (RBO), General Regulations For All Zones | 1 | Not listed | 7% of building footprint or 500 sq ft max (total for property) | Not listed |
Zone-by-Zone Sign Requirements in Stacy(sample of 3 of 6 zones)
Single Family Residential District (R1), One and Two Family Residential District (R2), Multiple Family Residential - Townhomes District (R-3A), Multiple Family Residential - Apartments District (R-3B), Manufactured Home Park District (R-M), Planned Unit Development (PUD), Rural Residential - I (RR-I), Rural Residential - II (RR-II)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Changeable Message Sign | Not listed | 32 square feet | Not listed | Setback of 10 feet from lot lines. | 1 per lot | Only allowed for non-residential uses (i.e., churches, schools, etc.) | Not listed | Unlock | § 153.101(B)(2); § 153.104(D) |
| Monument Sign | 10 feet | 36 square feet | Not listed | Setback of 10 feet from lot lines. | 1 per non-residential property | Only allowed for non-residential uses (i.e., churches, schools, etc.) | Not listed | Unlock | § 153.101(B)(2); § 153.104(E) |
| Temporary Sign | Not listed | 48 square feet | Not listed | Setback of 10 feet from lot lines. | 1 per business | Not listed | Not listed | Unlock | § 153.101(B)(2); § 153.094(C)-(D) |
| Window Sign | Not listed | 35% of one window | Not listed | Not listed | 1 per property | One window sign per property. | Not listed | Unlock | § 153.101(B)(2) |
Central Business District (CBD), General Business District (GB), Rural Transit Center (RTC), Light Industrial District (LI), Industrial District (I)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| A-Frame Sign | 4 feet | 6 square feet per side | Not listed | Not listed | 1 per business | On property within 10 feet of the primary entrance or out of right-of-way in front of the property. Not on sidewalk. | Not listed | Unlock | § 153.104(A) |
| Awning Sign | Not listed | 80% of total awning size; printing limited to 30% of awning area | Not listed | Not listed | One awning sign per awning plus one under-awning sign per business | Must maintain vertical clearance of 7'6", located min 18" from back of curb. | Not listed | Unlock | § 153.104(B) |
| Canopy Sign | Not listed | 80% of total canopy size; printing limited to 30% of canopy area | Not listed | Not listed | 1 canopy sign per canopy, 1 under-canopy sign | Min vertical clearance 7'6", min 18" from back of curb; support posts 5' apart and from walls. | Not listed | Unlock | § 153.104(C) |
| Changeable Message Sign | Not listed | 32 square feet | Not listed | At least 50 feet from any residential district or use; 10 feet from lot lines. | 1 per lot | Not listed | Not listed | Unlock | § 153.104(D) |
| Drive-Thru Sign | Not listed | 72 square feet | Not listed | Not listed | One per drive-thru lane | In close proximity to a drive-thru lane, on subject site. | Not listed | Unlock | § 153.101(B)(2) |
| Freestanding Sign | No higher than adjacent street lighting (CBD and GB) | 80 square feet | Not listed | 10 feet from lot lines. | Not listed | Not listed | Not listed | Unlock | § 153.101(B)(2); § 153.104(F) |
| Monument Sign | 10 feet | 80 square feet | Not listed | 10 feet from lot lines. | One per property (unless complex per § 153.102) | Not listed | Not listed | Unlock | § 153.101(B)(2); § 153.104(E) |
| Temporary Sign | Not listed | 48 square feet | Not listed | 10 feet from lot lines. | 1 per business | Not listed | Not listed | Unlock | § 153.101(B)(2); § 153.094(C)-(D) |
Park District (P), Open Space District (OS)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ballfield Sign | Not listed | 80% of the fence section the sign is affixed to | Not listed | Not listed | Not listed | On ballfield fencing | Not listed | Unlock | § 153.101(B)(2) |
| Freestanding Sign | No higher than adjacent street lighting | Not listed | Not listed | 10 feet from lot lines. | Not listed | Not listed | Not listed | Unlock | § 153.101(B)(2) |
| Monument Sign | 10 feet | 36 square feet | Not listed | 10 feet from lot lines. | Not listed | Not listed | Not listed | Unlock | § 153.101(B)(2) |
| Temporary Sign | Not listed | 48 square feet | Not listed | 10 feet from lot lines. | Not listed | Not listed | Not listed | Unlock | § 153.101(B)(2) |
| Wall Sign | Not listed | 40% of the face of the building | Not listed | Not listed | Not listed | On building wall | Not listed | Unlock | § 153.101(B)(2) |
| Window Sign | Not listed | 50% of the window | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | § 153.101(B)(2) |
PermitPal covers all 6 zoning districts in Stacy. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Stacy
- Any sign, signal, marking, or device which purports to be or resembles any official traffic control device, railroad sign or signal, or emergency vehicle signal.
- Signs erected or temporarily placed within any street right-of-way, upon public lands or easements, or other public rights-of-way, except as specifically provided or subject to a license or franchise.
- Signs or sign structures that prevent free ingress or egress from any door, window, fire escape, stairway, or other opening.
- Signs or sign structures attached to a standpipe or fire escape.
- Abandoned signs (must be removed within 30 days after written notice from the city).
- Any sign that obstructs the vision of drivers or pedestrians, or detracts from the visibility of any official traffic control device.
- Except where specifically permitted, any sign displaying moving parts, rotating, illuminated with flashing or intermittent lights, or any animated sign. (Clocks and barber poles are exempt.)
- Temporary or portable signs, except as permitted by a temporary sign permit.
- Signs painted, attached, or in any other manner affixed to trees, rocks, or similar natural surfaces, or on street/traffic signs, utility poles, bridges, towers, or similar public structures.
- Bench signs or signs affixed to amenities such as trash receptacles, located in the public right-of-way, unless approved by the city.
- Illuminated signs in which light is directed onto adjacent property or public streets. Search lights and beacons, and methods of attracting attention by directing light radiation away from a sign surface, are also prohibited except where specifically permitted.
- Any sign which becomes structurally unsafe or endangers the safety of a building or premises or public safety must be taken down and removed by the owner.
- Signs located in such a manner as to obstruct or interfere with an official traffic sign, signal, or device, or a driver's view of approaching, merging, or intersecting traffic.
- Except as otherwise provided, private signs encroaching upon or overhanging public right-of-way.
- No sign shall be attached to any utility pole, light standard, street tree, or other public facility located within the public right-of-way.
- Signs that blink, flash, or are animated by lighting in any fashion that would cause the appearance of traffic signs/lights or municipal vehicle warnings visible from the roadway.
- Portable signs except as allowed for temporary signs.
- Inflatable or flying devices such as balloons, streamers, or pinwheels, except those permitted as temporary signs.
- Signs that are structurally unsafe or in disrepair or which create a hazard by their condition, location, or lighting.
- Permanent signs or placards attached or added to any sign beyond that included in the application and permit.
- Animated signs, except flashing signs giving time, date, temperature, weather conditions, or similar public info.
- Roof signs extending above the peak of the roof.
- Exterior neon signs.
- A sign that violates any state law.
- Audio components on any sign, except for those utilized for visually impaired and for two-way communication.
- Any form of pyrotechnics.
- Any sign which is obscene, as defined by state law.
- Any sign which emits an audible sound, odor, or visible matter.
- Any torn, tattered, or faded sign, including temporary signs.
- No new billboards will be allowed in the city.
Exempt Signs in Stacy
- Official notices authorized by a court, public body, or public safety official, subject to general provisions.
- Interior window signs in business and industrial districts (no more than 1/2 of any individual window covered; not counted against sign area for other sign types).
- Interior signs.
- Directional, warning, or informational signs authorized by federal, state, or municipal governments, provided they do not exceed 48 square feet.
- Pedestrian, vehicular traffic, and parking directional signs in parking lots or on buildings, not exceeding 8 square feet in area and 6 feet in height, with no advertising message; maximum one per access/egress point per development.
- Memorial tablets, names of buildings, and date of erection when cut into masonry or constructed of bronze/incombustible material.
- Headstones, gravestones, grave markers, or similar placed at burial plots, columbariums, mausoleums, etc.
- Flags to the following limits: up to 150 sq ft in Public, Commercial, and Industrial zones; up to 40 sq ft in Residential zones (anything larger is regulated as a sign).
- Awnings without printing, except for street address number (number only), considered architectural feature.
- Canopies without printing, except for street address number (number only), considered architectural feature.
- Street address signs and combination nameplate/street address signs (no advertising copy, max 6 sq ft in area).
- Temporary signs not more than 4 sq ft, in place no longer than 4 days per event, not in right-of-way or on trees/utility poles.
- Bulletin boards.
- Signs denoting architect, engineer, or contractor on site and real estate signs relating to sale, development, or rental (removed within 10 days after completion/sale/lease of 90% of property, max 2 signs at one time, total area not to exceed 48 sq ft).
- Government signs in all districts.
- Signs not visible beyond boundaries of the lot or parcel.
- Security signs.
- Signs required by law.
- Signs integrally attached to or part of waste roll-offs, dumpsters, garbage cans, vending/dispensing machines, portable storage units, or similar equipment owned/maintained by a commercial business for waste collection/storage.
- Signs attached to or placed on personal property or motor vehicles/trailers, with conditions: primary purpose is not display of signs; signs are magnetic, decals, or painted as integral part of vehicle/equipment, do not break silhouette; vehicle/trailer must be operable, licensed, and actively used in the daily function of the business.
- Decorative display and/or elements (balloons, streamers, pennants, pinwheels without words or symbols).
- No exempt sign may be illuminated, except: uplighting of official federal, state, county, or city flags; and lighting of official government signs as needed by government body.
Sign Plan & Submission Notes for Stacy
- A sign plan is required for all development complexes consisting of 3 or more tenant spaces in commercial areas. The plan shall be filed with the project application and processed concurrently.
- The purpose of the sign plan is to integrate signs with building and landscaping design to form a unified architectural statement.
- Sign plans must address use of the same type of cabinet supports or mounting, construction material, and illumination for signs; for wall signs, must specify uniform positioning for both anchor and minor tenants.
- A complete set of plans and a site plan are generally required with sign permit applications, including landscape plan and photo-quality color renderings.
- The Planning Commission reviews all permanent sign permit applications; variances must be approved by the City Council as required by § 153.188.