Sign Regulations in Teterboro Borough, New Jersey
Teterboro Borough, New Jersey has specific sign regulations covering 13 sign types across 3 zoning districts. Regulated sign types include Nameplate Sign, Identification Sign, Bulletin Board Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Teterboro Borough, New Jersey
Sample Sign Requirements in Teterboro Borough
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Nameplate Sign | 15 feet | 2 square feet | 15 feet |
| Identification Sign | 15 feet | 20 square feet | 15 feet |
| Bulletin Board Sign | 15 feet | 20 square feet | 15 feet |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
13
- Nameplate Sign
- Identification Sign
- Bulletin Board Sign
- Real Estate Sign
- +2 more types
Zoning Districts
3
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Teterboro Borough
Other Cities in New Jersey
Frequently Asked Questions
In Teterboro Borough, the height limit for Ground Sign in the Light Industrial and Distribution Zone B is 30 feet. The height limit for Wall Sign in the Light Industrial and Distribution Zone B is 30 feet. Maximum sign heights range from 15 feet to 30 feet across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Teterboro Borough require a permit. From the submission notes on this page: Application for permit for a sign which does not comply with the provisions of this article shall be submitted to the appropriate approving authority, including any sign associated with a change in occupancy or ownership which does not comply with the provisions. Run a code check for an exact address to see the permit requirements for that zone.
Teterboro Borough's sign code covers 13 sign types, including Nameplate Sign, Identification Sign, Bulletin Board Sign, and Real Estate Sign. Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Nameplate signs not exceeding two square feet in gross surface area accessory to a multiple-family dwelling (exempt from permit but must comply with regulations). The full list is on this page.
In Teterboro Borough, Ground Sign in the Low Density Residential Zone must be set back 15 feet. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Teterboro Borough's sign ordinance that cover digital, changing, or flashing signs: No flashing signs, rotating or moving signs, animated signs, signs with moving lights or signs which create the illusion of movement shall be permitted in any district. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Teterboro Borough Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Teterboro Borough, New Jersey, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Teterboro Borough, New Jersey Sign Rules at a Glance
Teterboro Borough, New Jersey regulates 13 sign types across 3 zoning districts. Nameplate Signs in the Low Density Residential Zone are capped at 15 feet tall and 2 square feet, with a 15 feet setback. Most commercial signs in Teterboro Borough require a permit.
Detailed Sign Ordinance Requirements for Teterboro Borough, New Jersey
Sign Rules by Zoning District in Teterboro Borough (3 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Low Density Residential Zone | 8 | 15 feet | 60 square feet | Not listed |
| Light Industrial and Distribution Zone B | 12 | 30 feet | 250 square feet (per sign) | Not listed |
| General Regulations For All Zones | 1 | Not listed | 12 square feet | Not listed |
Zone-by-Zone Sign Requirements in Teterboro Borough
Low Density Residential Zone
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Nameplate Sign | 15 feet | 2 square feet | Not listed | 15 feet | One per lot | Not listed | Not listed | Unlock | §185-18D(5)(a)[1], (c), (e), (1)(a) |
| Identification Sign | 15 feet | 20 square feet | Not listed | 15 feet | One per lot | Not listed | Not listed | Unlock | §185-18D(5)(a)[2], (c), (e), (1)(a) |
| Bulletin Board Sign | 15 feet | 20 square feet | Not listed | 15 feet | One per lot | Not listed | Not listed | Unlock | §185-18D(5)(a)[2], (c), (e), (1)(a) |
| Real Estate Sign | 15 feet | 6 square feet per dwelling unit (not to exceed 100 square feet) | Not listed | 15 feet | One per lot | Not listed | Not listed | Unlock | §185-18D(5)(a)[3], (c), (e), (1)(a) |
| Construction Sign | 15 feet | 60 square feet | Not listed | 15 feet | One per lot | Not listed | Not listed | Unlock | §185-18D(5)(a)[4], (c), (e), (1)(a), (2)(a)[4] |
| Ground Sign | 15 feet | Apply functional sign type limits | Not listed | 15 feet | See functional sign regulations | Not listed | Not listed | Unlock | §185-18D(5)(b), (c), (e), (1)(a) |
| Pole Sign | 15 feet | Apply functional sign type limits | Not listed | 15 feet | See functional sign regulations | Not listed | Not listed | Unlock | §185-18D(5)(b), (c), (e), (1)(a) |
| Wall Sign | 15 feet | Apply functional sign type limits | Not listed | 15 feet | See functional sign regulations | Affixed to a wall | Not listed | Unlock | §185-18D(5)(b), (c), (e), (1)(a) |
Light Industrial and Distribution Zone B
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | Affixed to a wall | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b) |
| Ground Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | On ground, not attached to building | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b),(2)(b)[2] |
| Pole Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | On a freestanding pole | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b),(2)(b)[3] |
| Projecting Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | Projecting from a building | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b),(2)(b)[4] |
| Roof Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | Affixed to or painted on roof | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b),(2)(b)[6] |
| Awning or Canopy Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | Mounted/painted on awning or canopy | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b),(2)(b)[1] |
| Bulletin Board Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | Not listed | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b),(2)(a)[2] |
| Business Sign | 30 feet | 250 square feet (per sign) | Not listed | 10 feet | Single-tenant: 2 max; Multi-tenant: 1 per tenant | Not listed | Not listed | Unlock | §185-18D(6)(a), (b), (c), (d), (e), (f), (g), (1)(b),(2)(a)[3] |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Election/Political Sign | Not listed | 12 square feet | Not listed | Minimum 10 feet from property line | Not listed | Entirely on private property; not within public right-of-way; at least 10 feet from property line | Not listed | Unlock | §185-18D(7) |
Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in Teterboro Borough with a free PermitPal account.
Run a free code checkProhibited Signs in Teterboro Borough
- No sign, unless exempt under §185-18D(4), shall hereafter be constructed or erected, and no existing sign shall be moved, remodeled or expanded unless such sign complies or will thereafter comply with the applicable regulations.
- No sign shall be erected, altered, located or relocated within the municipality except upon application and the issuance of a permit as provided.
- No flashing signs, rotating or moving signs, animated signs, signs with moving lights or signs which create the illusion of movement shall be permitted in any district.
- No sign shall be maintained at any location where by reason of its position, size, shape or color it may obstruct, impair, obscure, interfere with the view of, or be confused with any traffic control sign, signal or device or where it may interfere with, mislead or confuse traffic.
- Signs shall be shaded wherever necessary to avoid casting bright light upon property located in any residence district or upon any public street or park.
- Any illuminated sign located on a lot adjacent to or across the street from any residence district, which sign is visible from such residence district, shall not be illuminated between the hours of 11:00 p.m. and 7:00 a.m.
Exempt Signs in Teterboro Borough
- Flags of a government or of a civic, philanthropic, educational or religious organization displayed on private property.
- Signs of a duly constituted governmental body, including traffic or similar regulatory devices, legal notices, warnings at railroad crossings and other instructional or regulatory signs having to do with health, hazards, parking, swimming, dumping, etc.
- Memorial signs and tablets displayed on private property.
- Address numerals and other signs required to be maintained by law or governmental order, rule or regulation, provided that the content and size of the sign do not exceed the requirements of such law, order, rule or regulation.
- Signs not exceeding five square feet in area displayed on private property for the convenience of the public, including signs to identify entrance and exit drives, parking areas, one-way drives, rest rooms, freight entrances and the like.
- Nameplate signs not exceeding two square feet in gross surface area accessory to a multiple-family dwelling (exempt from permit but must comply with regulations).
- Identification signs not exceeding 20 square feet in gross surface and accessory to a multiple-family dwelling (exempt from permit but must comply with regulations).
- Bulletin board signs not exceeding 20 square feet in gross surface area accessory to a church, school or public or nonprofit organization (exempt from permit but must comply with regulations).
Sign Plan & Submission Notes for Teterboro Borough
- Application for permit for a sign which does not comply with the provisions of this article shall be submitted to the appropriate approving authority, including any sign associated with a change in occupancy or ownership which does not comply with the provisions.
- Such application for a variance or non-conforming sign must be in writing, submitted at least 10 days before the next meeting preceding the succeeding public meeting date of the appropriate authority, include required drawings, and all information specified for a standard application.
- A permit for the replacement of an existing sign may be issued by the Zoning Officer without the necessity of Board approval only if there is no physical alteration/expansion, the sign fully conforms to regulations, and no other signage is proposed to be added.
Source: ecode360 municipal code