Sign Regulations in Pittsford, New York
Pittsford, New York has specific sign regulations covering 39 sign types across 15 zoning districts. Regulated sign types include Freestanding Sign - Commercial Complex, Directory Sign - Commercial Complex, Wall Sign - Single Entrance. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Pittsford, New York
Sample Sign Requirements in Pittsford
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Temporary For Sale/Lease Sign | 5 feet above grade | 4 sq ft (1-sided), 4 sq ft each side (2-sided) | 3 ft from any lot line, 18 inches from property line abutting right-of-way. |
| Resident Name/Address Plate | Not listed | 1 sq ft | Not listed |
| Architect/Contractor Sign (During Construction) | Not listed | 4 sq ft (1-sided), 4 sq ft per side (2-sided) | 18 inches from property line abutting right-of-way |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
39
- Freestanding Sign - Commercial Complex
- Directory Sign - Commercial Complex
- Wall Sign - Single Entrance
- Wall Sign - Multiple Entrances
- +2 more types
Zoning Districts
15
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Pittsford
Other Cities in New York
Frequently Asked Questions
In Pittsford, the height limit for Freestanding Sign - Commercial Complex in the Nonresidential District, Commercial District is 5 ft from grade (Sec. 168-7C(1)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Pittsford require a permit. From the submission notes on this page: Application for a permit must include scale drawings, location plans, construction details, and owner consent if the applicant is not the owner. Run a code check for an exact address to see the permit requirements for that zone.
Pittsford's sign code covers 39 sign types, including Freestanding Sign - Commercial Complex, Directory Sign - Commercial Complex, Wall Sign - Single Entrance, and Wall Sign - Multiple Entrances. Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Temporary political signs, as defined, are permitted according to size, location, and timing restrictions, and do not require Board approval or a permit. The full list is on this page.
In Pittsford, Architect/Contractor Sign (During Construction) must be set back 18 inches from property line abutting right-of-way (Sec. 168-6A(3)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Pittsford's sign ordinance that cover digital, changing, or flashing signs: No sign shall be illuminated by or contain flashing, intermittent, rotating or moving light or lights. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Pittsford Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Pittsford, New York, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Pittsford, New York Sign Rules at a Glance
Pittsford, New York regulates 39 sign types across 15 zoning districts. Resident Name/Address Plates are capped at 1 sq ft (Sec. 168-6A(2)). Most commercial signs in Pittsford require a permit.
Detailed Sign Ordinance Requirements for Pittsford, New York
Sign Rules by Zoning District in Pittsford (15 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 11 | 5 feet above grade | 4 sq ft (1-sided), 4 sq ft each side (2-sided) | Not listed |
| B-2 District | 1 | Not listed | 1 sq ft (fuel price), remainder not specified | Not listed |
| Nonresidential District, Commercial District | 14 | 5 ft from grade | Principal elevation: 30 sq ft; Other elevations: 8 sq ft each | Not listed |
| Commercial Complex | 4 | 5 ft from grade | 30 sq ft | Not listed |
| Single Commercial Building | 1 | Not listed | Principal elevation: 30 sq ft; Other elevations: 8 sq ft each | Not listed |
| Multiple Commercial Building | 2 | Not listed | 30 sq ft | Not listed |
| Hotel, Gasoline Service Station | 1 | 5 ft | 16 sq ft per side, up to 2 sides | Not listed |
| Office District | 3 | Not listed | 30 sq ft | Not listed |
| Office Complex | 3 | 5 ft from grade | 16 sq ft per side, up to 2 sides | Not listed |
| Single-office Building | 1 | Not listed | 30 sq ft | Not listed |
| Multiple-office Building | 2 | Not listed | 30 sq ft | Not listed |
| Office in a Single or Multiple Commercial Building | 1 | Not listed | 1 sq ft | Not listed |
| Office in a Commercial Complex | 1 | Not listed | 1 sq ft | Not listed |
| R-4 District | 1 | Not listed | 1 sq ft | Not listed |
| Central Business District | 1 | Not listed | Not listed | Not listed |
Zone-by-Zone Sign Requirements in Pittsford(sample of 3 of 15 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | Not listed | Not listed | Not listed | Not listed | Not listed | On the fringe of roll-type awning, attached to a building elevation. | Not listed | Unlock | §168-5A |
| Projecting Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Prohibited from erection on any building elevation. | Not listed | Unlock | §168-5D |
| Roof Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Prohibited except aviation directional signs painted on roof as permitted by federal/state regulation. | Not listed | Unlock | §168-5E |
| Portable Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Prohibited except as specifically provided for temporary signs or in special sections. | Not listed | Unlock | §168-5F |
| Temporary For Sale/Lease Sign | 5 feet above grade | 4 sq ft (1-sided), 4 sq ft each side (2-sided) | Not listed | 3 ft from any lot line, 18 inches from property line abutting right-of-way. | 1 per street frontage | On premises offered for sale/lease | Not listed | Unlock | §168-6A(1) |
| Resident Name/Address Plate | Not listed | 1 sq ft | Not listed | Not listed | Not listed | On the premises | Not listed | Unlock | §168-6A(2) |
| Architect/Contractor Sign (During Construction) | Not listed | 4 sq ft (1-sided), 4 sq ft per side (2-sided) | Not listed | 18 inches from property line abutting right-of-way | Not listed | On premises under construction, repair, or renovation | Not listed | Unlock | §168-6A(3) |
| Historic Date/Erection Tablet | Not listed | 4 sq ft | Not listed | Not listed | Not listed | On relevant building/home | Not listed | Unlock | §168-6A(4) |
Nonresidential District, Commercial District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign - Single Commercial Building | Not listed | Principal elevation: 30 sq ft; Other elevations: 8 sq ft each | Not listed | Not listed | 1 per elevation facing public street/waterway | Each elevation facing a public street/waterway | Not listed | Unlock | §168-7A(1) |
| Wall Sign - Multiple Commercial Building - Single Entrance | Not listed | 30 sq ft | Not listed | Not listed | 1 per establishment | On elevation of entrance serving a single commercial establishment | Not listed | Unlock | §168-7B(1) |
| Wall Sign - Multiple Commercial Building - Multiple Entrances | Not listed | Group: 30 sq ft; Each sign: per linear front but cannot exceed 30 total | Not listed | Not listed | 1 per establishment per entrance | On elevation of entrance serving multiple commercial establishments | Not listed | Unlock | §168-7B(2), (2)(a), (2)(b) |
| Freestanding Sign - Commercial Complex | 5 ft from grade | 16 sq ft (1 side), up to 2 sides | Not listed | Not listed | 1 per entrance | At commercial complex entrance(s); must not obstruct vehicular/pedestrian visibility | Not listed | Unlock | §168-7C(1) |
| Directory Sign - Commercial Complex | 5 ft (if freestanding) | Sum of 1 sq ft per establishment/office listed | Not listed | Not listed | 1 per complex | Approved by Planning Board; must not obstruct visibility if freestanding | Not listed | Unlock | §168-7C(2) |
| Wall Sign - Commercial Complex - Single Entrance | Not listed | 30 sq ft | Not listed | Not listed | 1 per establishment per entrance | On elevation of entrance serving single commercial establishment | Not listed | Unlock | §168-7C(3)(a) |
| Wall Sign - Commercial Complex - Multiple Entrances | Not listed | Each sign cannot exceed allotted area in group (max 30 sq ft for group) | Not listed | Not listed | 1 per establishment per entrance | On elevation of entrance serving more than one commercial establishment | Not listed | Unlock | §168-7C(3)(b), [1], [2] |
| Freestanding Sign (Hotel or Gasoline Service Station) | 5 ft | 16 sq ft per side, up to 2 sides | Not listed | Not listed | 1 per location | On premises of hotel or gasoline service station | Not listed | Unlock | §168-7E(1) |
Commercial Complex
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign - Commercial Complex | 5 ft from grade | 16 sq ft per side, up to 2 sides | Not listed | Not listed | 1 per entrance | At each entrance from a public way, must not obstruct visibility | Not listed | Unlock | §168-7C(1) |
| Directory Sign - Commercial Complex | 5 ft from grade (if freestanding) | Not listed | Not listed | Not listed | 1 per complex | Approved by Planning Board; may be freestanding, must not obstruct visibility | Not listed | Unlock | §168-7C(2) |
| Wall Sign - Single Entrance | Not listed | 30 sq ft | Not listed | Not listed | 1 per entrance per establishment | On elevation of entrance to establishment | Not listed | Unlock | §168-7C(3)(a) |
| Wall Sign - Multiple Entrances | Not listed | Group: 30 sq ft; Each sign up to its allotted proportion | Not listed | Not listed | 1 per entrance per establishment | On elevation of entrance to multiple establishments | Not listed | Unlock | §168-7C(3)(b), [1], [2] |
PermitPal covers all 15 zoning districts in Pittsford. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Pittsford
- No sign other than those expressly permitted in this chapter shall be erected or maintained.
- No sign shall be internally lighted.
- No sign shall be illuminated by or contain flashing, intermittent, rotating or moving light or lights.
- Illuminated signs or lighting devices must employ only lights emitting a light of constant intensity.
- Illuminated sign or lighting device beams and illumination may not be directed upon a public street, highway, sidewalk, or adjacent premises so as to cause glare or constitute a traffic hazard or nuisance.
- No gas-filled tubes (neon) are permitted on any exterior elevation of any building. No other gas-filled tube (neon) signs visible from a public street or waterway are permitted except as otherwise provided.
- No projecting sign shall be erected or maintained from any elevation of a building.
- No sign shall be erected or maintained in or upon any public or private street, sidewalk or other right-of-way.
- All signs must be affixed to a building, placed parallel to the building or elevation, may not extend beyond the sides of the building or above any roof ridge or solid parapet wall, and may not be painted or pasted on walls.
- No signs shall be placed on or attached to any roof of any building, except aviation directional signs painted on the roof in compliance with federal and state regulations.
- No portable or temporary sign shall be placed on any elevation of a building or parked or otherwise located on any premises except as specifically provided.
- No pennants, ribbons, streamers, spinners or other similar moving, fluttering or revolving devices, as well as strings of lights with bulbs larger than 2.5 volts, are permitted.
Exempt Signs in Pittsford
- Signs erected and maintained pursuant to and in discharge of any governmental function or required by any law, ordinance, or governmental regulation are not considered 'signs' for the purposes of this chapter.
- Signs denoting property for sale, lease, or rental of the premises upon which the sign is located (subject to limitations on size, location, and number).
- Signs denoting the name and address of the residents of the premises (not exceeding one square foot).
- Signs denoting the architect, engineer, or contractor, placed on premises where construction, repair, or renovation is in progress (not exceeding four square feet per side; subject to placement restrictions).
- Historic signs or tablets denoting only the date of erection and other historic information of homes/buildings made of cast metal and not exceeding four square feet.
- Temporary political signs, as defined, are permitted according to size, location, and timing restrictions, and do not require Board approval or a permit.
- Temporary signs as provided for in §168-12 are permitted without Board approval and without a permit.
Sign Plan & Submission Notes for Pittsford
- A sign permit is required for most signs except as otherwise provided for exempt signs (such as certain temporary or political signs).
- Application for a permit must include scale drawings, location plans, construction details, and owner consent if the applicant is not the owner.
- No sign may be erected without prior approval from the Architectural and Preservation Review Board and a permit from the Village Building Inspector, except for signs permitted without a permit.
- For multiple-office buildings and office complexes, a sign permit shall be issued for the sign plan (including any building name, address sign, directory signs, and nameplates). Copy changes within directory signs or upon nameplates do not require a new permit.
- A sign permit shall be issued for any directory sign(s) in office buildings, commercial buildings, or complexes. Copy changes within the directory sign(s) do not require a new permit.
- Variances from the chapter may be granted by the Zoning Board of Appeals after public notice and hearing.
Source: ecode360 municipal code