Sign Regulations in South Glens Falls, New York

South Glens Falls, New York has specific sign regulations covering 21 sign types across 3 zoning districts. Regulated sign types include Nameplate and Identification Sign, Agricultural Sign, Institutional Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 28, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for South Glens Falls, New York

Sample Sign Requirements in South Glens Falls

Sign TypeMax HeightMax AreaSetback
Nameplate and Identification SignNot listed3 square feet (combined total)Not listed
Agricultural SignNot listed15 square feet (combined total)Not listed
Institutional SignNot listed15 square feet (combined total)Not listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for South Glens FallsFull Coverage

Sign Types Covered

21

  • Nameplate and Identification Sign
  • Agricultural Sign
  • Institutional Sign
  • Business Sign (Legal Nonconforming Use)
  • +2 more types

Zoning Districts

3

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for South Glens Falls

Municipal Code2 permit application links available

Frequently Asked Questions

This page doesn't give a single height number for signs in South Glens Falls. The tables on this page quote the ordinance's height rules for the sign types we sampled. For example, the height rule for Business Sign (Commercial/Industrial) in the Commercial districts, Industrial districts reads: Less than 10 feet above ground level. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in South Glens Falls require a permit. From the submission notes on this page: Application for a permit must include a detailed drawing or blueprint showing construction details, lettering, lighting, a location plan showing position of the sign on the building or land in relation to nearby structures and streets. Run a code check for an exact address to see the permit requirements for that zone.

South Glens Falls's sign code covers 21 sign types, including Nameplate and Identification Sign, Agricultural Sign, Institutional Sign, and Business Sign (Legal Nonconforming Use). Most commercial signs need a permit. The ordinance lists 2 exemptions. One of them: Temporary signs, advertising display panels, posters, and similar graphic materials relating to general sales, information, special events, and sales promotions may be displayed without a permit, provided they comply with size, quantity, and placement requirements specified. The full list is on this page.

This page doesn't list a single setback distance for signs in South Glens Falls. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.

South Glens Falls's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.

AI-Powered Research

Ready to Research South Glens Falls Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in South Glens Falls, New York, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

South Glens Falls, New York Sign Rules at a Glance

South Glens Falls, New York regulates 21 sign types across 3 zoning districts. Political Posters (Business District) are capped at 9 square feet (Sec. 115-4C(8)). Most commercial signs in South Glens Falls require a permit.

Detailed Sign Ordinance Requirements for South Glens Falls, New York

Sign Rules by Zoning District in South Glens Falls (3 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
RC-1, Residential districts5Not listed20 square feet (combined total)Not listed
Commercial districts, Industrial districts7Less than 10 feet above ground level40 square feet (combined total), or up to 100 square feet (see formula)Not listed
General Regulations For All Zones12Not listed100 square feetNot listed

Zone-by-Zone Sign Requirements in South Glens Falls

RC-1, Residential districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Nameplate and Identification SignNot listed3 square feet (combined total)Not listedNot listedNot listedIndicating the name and address of the occupant or permitted home occupation on the premisesNot listedUnlock§115-4A(1)
Agricultural SignNot listed15 square feet (combined total)Not listedNot listedNot listedCustomary agriculture operations selling farm productsNot listedUnlock§115-4A(2)
Institutional SignNot listed15 square feet (combined total)Not listedNot listedNot listedOn premises of schools, churches, or similar public and semipublic institutionsNot listedUnlock§115-4A(3)
Business Sign (Legal Nonconforming Use)Not listed20 square feet (combined total)Not listedNot listedNot listedOn premises of legal nonconforming useNot listedUnlock§115-4A(4)
Temporary Business SignNot listed6 square feet (combined total)Not listedNot listedNot listedAdvertising sale, rental, construction or improvement of the premises on which they are locatedNot listedUnlock§115-4A(5)

Commercial districts, Industrial districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Nameplate and Identification SignNot listed3 square feet (combined total)Not listedNot listedNot listedIndicating the name and address of the occupant or permitted home occupation on the premisesNot listedUnlock§115-4B(1), §115-4A(1)
Agricultural SignNot listed15 square feet (combined total)Not listedNot listedNot listedCustomary agriculture operations selling farm productsNot listedUnlock§115-4B(1), §115-4A(2)
Institutional SignNot listed15 square feet (combined total)Not listedNot listedNot listedOn premises of schools, churches, or similar public and semipublic institutionsNot listedUnlock§115-4B(1), §115-4A(3)
Business Sign (RC-1/Residential Nonconforming Use)Not listed20 square feet (combined total)Not listedNot listedNot listedOn premises of legal nonconforming useNot listedUnlock§115-4B(1), §115-4A(4)
Temporary Business Sign (RC-1/Residential)Not listed6 square feet (combined total)Not listedNot listedNot listedAdvertising the sale, rental, construction, or improvement of the premisesNot listedUnlock§115-4B(1), §115-4A(5)
Business Sign (Commercial/Industrial)Less than 10 feet above ground level40 square feet (combined total), or up to 100 square feet (see formula)Not listedSigns must be at least 3 feet above ground level.Not listedOn building or immediate premisesNot listedUnlock§115-4B(2)
Temporary Business Sign (Commercial/Industrial)Not listed10 square feet (combined total)Not listedNot listedNot listedAdvertising the sale, rental, construction, or improvement of the premisesNot listedUnlock§115-4B(4)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall/Front Facade Sign (≤ 100 ft Setback)Not listed100 square feetNot listed≤100 linear feet from front property lineNot listedWall/facade, facing streetNot listedUnlock§115-4E(1)
Wall/Front Facade Sign (>100 ft Setback)Not listedNot listedNot listed>100 linear feet from front property lineNot listedWall/facade, facing streetNot listedUnlock§115-4E(1)
Rear Delivery Entrance Sign (Plaza/Two+ Streets, one Residential)Not listed6 square feet per establishmentNot listedNot listedNot listedRear delivery entrance on residential sideNot listedUnlock§115-4E(2)
Sign Directory (Off-Street Plaza or Multi-Business Building)Not listed75 square feet maximumNot listedNot listedNot listedPlaza/building with multiple businessesNot listedUnlock§115-4D(6)
Temporary Posters/Sale/Event GraphicsNot listed12 square feet (3 ft x 4 ft per sign)3 ft x 4 ft per signNot listedMax 4 per facadeFacade of businessNot listedUnlock§115-4D(3)
Political Poster (Residential District)Not listed9 square feetNot listedNot listedNot listedResidential districtNot listedUnlock§115-4C(8)
Political Poster (Business District)Not listed9 square feetNot listedNot listedNot listedBusiness districtNot listedUnlock§115-4C(8)
Poster (Event, Not-For-Profit Group) (Business Door)Not listed1.5 square feet per poster (1 ft x 1.5 ft)1 ft x 1.5 ft per posterNot listedNo more than 2 per doorDoor of business establishmentNot listedUnlock§115-4D(4)

Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in South Glens Falls with a free PermitPal account.

Run a free code check

Prohibited Signs in South Glens Falls

  • No sign shall be erected so that any portion thereof shall be any closer than five feet to the nearest lot line or within five feet of any utility pole.
  • No signs shall be erected which may cause hazardous or unsafe conditions.
  • Any sign which becomes hazardous due to changed conditions shall be removed following written notice to the owner.
  • Signs must be constructed of durable materials and maintained in good condition; signs that deteriorate must be removed upon direction of the Building Inspector and/or Code Enforcement Officer.
  • The maximum height of any portion of any sign shall not exceed above the facade of any building on the premises.
  • Temporary signs such as political posters, banners, promotional devices, and other similar signs shall not be attached to fences, trees, utility poles, or similar objects.
  • Temporary signs shall not be placed in a position that will obstruct or impair vision or traffic, or create a hazard or disturbance to the health and welfare of the general public.
  • Light sources, with the exception of neon, shall be shielded or screened so as not to be seen by passersby from a normal viewing angle. Intense or glaring light is to be avoided.
  • Light sources for signs shall be limited to natural white incandescent or fluorescent lamps.
  • Signs must comply with all applicable building code ordinances of the Village of South Glens Falls and the New York State Uniform Fire Prevention and Building Code.

Exempt Signs in South Glens Falls

  • Temporary signs, advertising display panels, posters, and similar graphic materials relating to general sales, information, special events, and sales promotions may be displayed without a permit, provided they comply with size, quantity, and placement requirements specified.
  • Not more than two posters concerning an event sponsored by a not-for-profit group, with dimensions not exceeding 1 foot by 1.5 feet, may be displayed without a permit on the door of a business establishment.

Sign Plan & Submission Notes for South Glens Falls

  • No person shall erect any signs allowed except as otherwise herein provided without first obtaining a permit from the Building Inspector and/or Code Enforcement Officer.
  • Application for a permit must include a detailed drawing or blueprint showing construction details, lettering, lighting, a location plan showing position of the sign on the building or land in relation to nearby structures and streets.
  • Certification of an electrical inspection is required for any sign having electrical connections.
  • A variance or special permit is required from the Zoning Board of Appeals if sign area exceeds specified limits or for signs as required by the terms of the chapter.
  • No references to a master sign plan or sign plan review process for multi-tenant centers are found.