Heath, Ohio has specific sign regulations covering 8 sign types across 3 zoning districts. Regulated sign types include Wall Signs, Freestanding, Major Multi-Tenant Sign - Pylon, Freestanding, Major Multi-Tenant Sign - Pedestal or Monument. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 11, 2025
Sign Regulation Overview for Heath, Ohio
Sample Sign Requirements in Heath
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Freestanding, Major Multi-Tenant Sign - Pylon | 25 ft. | 400 Sq. Ft. total sign faces; NO one sign face exceeding 200 sq. ft. | 10 ft. |
| Freestanding, Major Multi-Tenant Sign - Pedestal or Monument | 12 ft. in lieu of pylon otherwise should not exceed 5 ft. | 128 sq. ft. for total sign faces; NO face exceeding 64 square feet. | 5 ft. |
| Freestanding, Major Multi-Tenant Sign - Tenant Directory or Kiosk | 6 ft. unless sign is set back more than 50' from right-of-way - then 10' | 15 sq. ft. per sign face | 10 ft. |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
8
- Wall Signs
- Freestanding, Major Multi-Tenant Sign - Pylon
- Freestanding, Major Multi-Tenant Sign - Pedestal or Monument
- Freestanding, Major Multi-Tenant Sign - Tenant Directory or Kiosk
- +2 more types
Zoning Districts
3
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Heath
Other Cities in Ohio
Frequently Asked Questions
In Heath, monument signs are limited to 25 ft.. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.
To get a sign permit in Heath, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Heath, regulated sign types include Wall Signs, Freestanding, Major Multi-Tenant Sign - Pylon, Freestanding, Major Multi-Tenant Sign - Pedestal or Monument, Freestanding, Major Multi-Tenant Sign - Tenant Directory or Kiosk, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
In Heath, monument signs typically require a 10 ft. setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.
Digital and LED signs in Heath are regulated with specific requirements for brightness, animation, and message duration. Heath has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Heath Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Heath, Ohio sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Heath, Ohio Sign Rules at a Glance
Heath, Ohio regulates 8 sign types across 3 zoning districts. Freestanding, Major Multi-Tenant Sign - Pylons in the General Business (B-3), Light Manufacturing (M-1), Heavy Manufacturing (M-2) zoning district are capped at 25 ft. tall and 400 Sq. Ft. total sign faces; NO one sign face exceeding 200 sq. ft., with a 10 ft. setback (Sec. 1187.09(a)(2)). Most commercial signs in Heath require a permit.
Detailed Sign Ordinance Requirements for Heath, Ohio
Sign Rules by Zoning District in Heath (3 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Business (B-3), Light Manufacturing (M-1), Heavy Manufacturing (M-2) | 4 | 25 ft. | 400 Sq. Ft. total sign faces; NO one sign face exceeding 200 sq. ft. | — |
| B-1, B-2 | 3 | 6 ft. unless sign is set back more than 50' from right-of-way - then 10' | 300 sq. ft. | — |
| General Regulations For All Zones | 2 | — | One third (33.3%) of the total area of the sign per side or ten square feet per side, whichever is more | — |
Zone-by-Zone Sign Requirements in Heath
General Business (B-3), Light Manufacturing (M-1), Heavy Manufacturing (M-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding, Major Multi-Tenant Sign - Pylon | 25 ft. | 400 Sq. Ft. total sign faces; NO one sign face exceeding 200 sq. ft. | — | 10 ft. | Frontage = 250 ' - 750' = 1 Sign; Frontage = More than 750' = 2 signs | — | — | Unlock | 1187.09(a)(2) |
| Freestanding, Major Multi-Tenant Sign - Pedestal or Monument | 12 ft. in lieu of pylon otherwise should not exceed 5 ft. | 128 sq. ft. for total sign faces; NO face exceeding 64 square feet. | — | 5 ft. | If utilizing a pedestal or monument sign in lieu of a pylon sign, then the same number as above based on frontage, plus two additional 5 ft. high monument signs to identify the complex is allowed per entrance from public right-of-way. | — | — | Unlock | 1187.09(a)(2) |
| Freestanding, Major Multi-Tenant Sign - Tenant Directory or Kiosk | 6 ft. unless sign is set back more than 50' from right-of-way - then 10' | 15 sq. ft. per sign face | — | 10 ft. | 1 per frontage on public right-of-way | — | — | Unlock | 1187.09(a)(2) |
| Wall Signs | No sign should project above the roof line | 300 sq. ft. | — | — | Unlimited - but total sum area not to exceed maximum allowable sq. footage | — | — | Unlock | 1187.09(a)(1) |
B-1, B-2
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign - Pedestal or Monument | 5 ft. | 80 sq. ft. Total of all sign faces. No sign face to exceed 40 sq. ft. | — | 5 ft. | 1 per frontage on public right-of-way | — | — | Unlock | 1187.09(c) |
| Freestanding Sign - Tenant Directory | 6 ft. unless sign is set back more than 50' from right-of-way - then 10' | 15 sq. ft. per sign face | — | 10 ft. | 1 per frontage on public right-of-way | — | — | Unlock | 1187.09(c) |
| Wall Signs | No sign should project above the roof line | 300 sq. ft. | — | — | 1 for every 4,000 sq. ft. exposed building face | — | — | Unlock | 1187.09(c) |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Digital Signs | — | 32 sq. ft. for single-tenant sites or multi-tenant sites having less than 200 feet of road frontage; 100 sq. ft. for multi-tenant sites having more than 200 feet of road frontage | — | — | No more than one digital sign is allowed per site unless it is a multi-tenant location with 750 feet or more of road frontage. | Prohibited everywhere except in the B-3, M-1, and M-2 Zoning Districts. | — | Unlock | 1187.10(b) |
| Manual Changeable Copy Signs | — | One third (33.3%) of the total area of the sign per side or ten square feet per side, whichever is more | — | — | — | Permitted on ground signs only | — | Unlock | 1187.10(c) |
Illumination rules, size formulas, and permit requirements for every sign type in Heath are available with a free PermitPal account.
Start freeProhibited Signs in Heath
- No sign shall contain or consist of banners, pennants, ribbons, streamers or similar moving devices.
- Off premise signs are prohibited.
- Roof signs are prohibited.
- No sign shall be placed in, over, or extend onto any public right-of-way except for projecting nameplates on lots where no front yard exists and for publicly owned signs such as traffic control and directional signs.
- No sign shall be placed in, over or extend above the roof line of any structure.
- No sign or signs may exceed the maximum area permitted for that building face except as may be specifically permitted by this code.
- No wall sign facing and within 500 feet of a residential area shall be illuminated.
- Streamers are prohibited.
- Portable signs, AA or AT frame signs, windblown, or trailer signs are prohibited.
- Incidental signs are prohibited.
Exempt Signs in Heath
- Address and name of occupant of premises for a residential structure, not including designations as to employment or home occupation and to be limited in size to two square feet.
- Signs required or authorized for a public purpose by any law, statute or ordinance, such signs to include traffic control devices provided that such signs contain no supplementary advertising.
- On site directional signs indicating points of entry or exit for a facility or off-street parking area, provided such signs are limited to a maximum of two square feet in area and three feet in height and do not interfere with safe vehicular or pedestrian traffic circulation and are not located within the clear sight distance triangle.
- Signs which are in the nature of cornerstones, commemorative tables and historical signs, provided that such signs are less than nine square feet in size and not illuminated.
- Signs clearly in the nature of decorations customarily associated with any national, local or religious holiday, to be limited to 60 days in any one year and to be displayed not more than 60 consecutive days.
- Political signs or posters concerning candidates for elected office, public issues and similar matters to be decided by public election.
- Signs that indicate the sale, rental or lease of a particular one or two family residential structure or one or two family residential land area, to be limited in size to six square feet, with one sign allowed per lot.
- Informational window signs that are limited in size to two square feet per sign.
- Signs which are less than two square feet in size and are mounted or attached flat or parallel onto a building face of an administrative, business or professional office building which denotes the name and address of an occupant in a building where more than one tenant is located and which has individual and separate entries.
- A sign which advertises the sale of personal property such as a garage, yard, porch or moving sale sign provided that it is limited to one sign, not greater than four square feet in size and which sign is located on the sale premises for a time period not greater than two consecutive days.
- Construction signs which display the identification of the contractors, architects and other construction principals and temporary development signs which shall include signs indicating or promoting the development of land, facilities, or structures.
- Signs for community events and programs which last for a period of 14 days or less and which are sponsored by nonprofit, public, educational, religious and charitable organizations.
- Signs that indicate the sale, rental, or lease of a particular residential or non-residential undeveloped parcel over three acres in area, multi-family, commercial structure or industrial land area, to be limited to 16 square feet in area and eight feet in height, with one sign allowed per street front.
- Temporary window signs do not require a permit.
- Business flags, not exceeding one per parcel and displaying the corporate or business emblem or seal, may be displayed if flown on a vertical staff or pole and in conjunction with the national flag.
- Menu boards, provided such signs are oriented solely for the use of patrons utilizing the drive-thru and are not intended to be visible from adjacent property or the right-of-way.
- Messages displayed upon approved Manual Changeable Copy Signs provided for in Section 1187.10(3) may be changed without permit.
Sign Plan & Submission Notes for Heath
- Applications for sign permits shall contain two copies of plans and/or blueprints to scale of signage including details of fastening, lighting, and any lettering, symbols or other identification which will be on the sign.
- A site plan of a proposed ground sign location showing the distance from a public right-of-way and relationship to access drives, parking areas and buildings or a facade elevation of proposed wall or window signs showing the height and proportions of the signs.
- Variances to this chapter may be granted pursuant to the procedure and criteria set forth in Chapter 1127.08.
- Applications for permanent subdivision identification signs must demonstrate provisions for future maintenance and maintenance easements at the time of final platting.