Mc Alester, Oklahoma has specific sign regulations covering 12 sign types across 1 zoning districts. Regulated sign types include Ground Sign (Accessory), Ground Sign (Nonaccessory), Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: January 16, 2026
Sign Regulation Overview for Mc Alester, Oklahoma
Sample Sign Requirements in Mc Alester
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Ground Sign (Accessory) | 70 ft total height | — | Setback from street ≥10 ft or to building line (as established by Art. IV), whichever is less. |
| Ground Sign (Nonaccessory) | 70 ft total height | — | Setback from street ≥25 ft or to building line (as established by Art. IV), whichever is greater. |
| Wall Sign | — | 500 sq ft | Projection beyond building line limited to ≤6 inches. |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
12
- Ground Sign (Accessory)
- Ground Sign (Nonaccessory)
- Wall Sign
- Roof Sign
- +2 more types
Zoning Districts
1
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Mc Alester
Other Cities in Oklahoma
Frequently Asked Questions
Sign height limits in Mc Alester vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.
To get a sign permit in Mc Alester, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Mc Alester, regulated sign types include Ground Sign (Accessory), Ground Sign (Nonaccessory), Wall Sign, Roof Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Mc Alester vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Mc Alester are regulated with specific requirements for brightness, animation, and message duration. Mc Alester has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Mc Alester Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Mc Alester, Oklahoma sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Mc Alester, Oklahoma Sign Rules at a Glance
Mc Alester, Oklahoma regulates 12 sign types across 1 zoning district. Roof Signs in the General Regulations For All Zones (R-1A, R-1B, R-1C, R-2, R-3, C-1, C-2, C-3, C-4, C-5, I-1, I-2, H-1, A-1, F-O) zoning district are capped at Highest point ≤20 ft above roof level tall and 300 sq ft, with a Face of sign ≥5 ft from outside wall toward which sign faces. setback (Sec. Sec. 62-782—62-787; Sec. 62-783; Sec. 62-784; Sec. 62-786; Sec. 62-787; Sec. 62-635; Sec. 62-636; Sec. 62-633; Sec. 62-637—62-639; Sec. 62-640—62-642; Sec. 62-675—62-681). Most commercial signs in Mc Alester require a permit.
Detailed Sign Ordinance Requirements for Mc Alester, Oklahoma
Sign Rules by Zoning District in Mc Alester (1 zone)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones (R-1A, R-1B, R-1C, R-2, R-3, C-1, C-2, C-3, C-4, C-5, I-1, I-2, H-1, A-1, F-O) | 12 | 70 ft total height | 500 sq ft | — |
Zone-by-Zone Sign Requirements in Mc Alester
General Regulations For All Zones (R-1A, R-1B, R-1C, R-2, R-3, C-1, C-2, C-3, C-4, C-5, I-1, I-2, H-1, A-1, F-O)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Sign (Accessory) | 70 ft total height | — | — | Setback from street ≥10 ft or to building line (as established by Art. IV), whichever is less. | — | On private property; construction within street line or ≤5 ft thereof must have smooth surfaces with no protruding nails/tacks/wires (electrical devices may extend over top/front). | — | Unlock | Sec. 62-732; Sec. 62-733; Sec. 62-734; Sec. 62-735; Sec. 62-736; Sec. 62-737; Sec. 62-634; Sec. 62-635; Sec. 62-636; Sec. 62-637; Sec. 62-638; Sec. 62-639; Sec. 62-640; Sec. 62-641; Sec. 62-642; Sec. 62-633; Sec. 62-675—62-681; Sec. 62-679 |
| Ground Sign (Nonaccessory) | 70 ft total height | — | — | Setback from street ≥25 ft or to building line (as established by Art. IV), whichever is greater. | — | On private property; construction within street line or ≤5 ft thereof must have smooth surfaces with no protruding nails/tacks/wires (electrical devices may extend over top/front). | — | Unlock | Sec. 62-732; Sec. 62-733; Sec. 62-734; Sec. 62-735 (Nonaccessory); Sec. 62-736; Sec. 62-737; Sec. 62-634; Sec. 62-635; Sec. 62-636; Sec. 62-637; Sec. 62-638; Sec. 62-639; Sec. 62-640; Sec. 62-641; Sec. 62-642; Sec. 62-633; Sec. 62-675—62-681; Sec. 62-631 |
| Wall Sign | — | 500 sq ft | — | Projection beyond building line limited to ≤6 inches. | — | Must be attached to a wall at a height of ≥10 ft above sidewalk or ground. | — | Unlock | Sec. 62-760—62-764; Sec. 62-761; Sec. 62-762; Sec. 62-763; Sec. 62-635; Sec. 62-636; Sec. 62-633; Sec. 62-637; Sec. 62-638; Sec. 62-639; Sec. 62-640—62-642; Sec. 62-675—62-681 |
| Roof Sign | Highest point ≤20 ft above roof level | 300 sq ft | — | Face of sign ≥5 ft from outside wall toward which sign faces. | — | Face of sign must be ≥5 ft from the outside wall toward which the sign faces; must not prevent free passage across roof or interfere with roof openings. | — | Unlock | Sec. 62-782—62-787; Sec. 62-783; Sec. 62-784; Sec. 62-786; Sec. 62-787; Sec. 62-635; Sec. 62-636; Sec. 62-633; Sec. 62-637—62-639; Sec. 62-640—62-642; Sec. 62-675—62-681 |
| Projecting Sign (Horizontal) | — | 50 sq ft per side (two-faced required) | — | No part of sign may extend nearer to curbline than 1 ft; must be ≤2 ft from face of wall. | — | Mount ≥10 ft above sidewalk; ≤2 ft from face of wall (nearest point); extend no nearer than 1 ft to curbline; if over driveways/alleys/thoroughfares, mount ≥15 ft above level. | — | Unlock | Sec. 62-813—62-822; Sec. 62-815(1); Sec. 62-816; Sec. 62-817; Sec. 62-818; Sec. 62-819; Sec. 62-820; Sec. 62-821; Sec. 62-822 |
| Projecting Sign (Vertical) | — | 100 sq ft per side (two-faced required) | — | No part of sign may extend nearer to curbline than 1 ft; must be ≤2 ft from face of wall. | — | Mount ≥10 ft above sidewalk; ≤2 ft from face of wall (nearest point); extend no nearer than 1 ft to curbline; if over driveways/alleys/thoroughfares, mount ≥15 ft above level. | — | Unlock | Sec. 62-813—62-822; Sec. 62-815(2); Sec. 62-816; Sec. 62-817; Sec. 62-818; Sec. 62-819; Sec. 62-820; Sec. 62-821; Sec. 62-822 |
| Street Clock (Sidewalk Install) | Post total height ≥15 ft | — | — | ≥20 ft from street line intersection; installation on sidewalk only with special council permission. | Maximum 1 per place of business at a single location | At least 20 ft from intersection of street lines, measured parallel with street. | — | Unlock | Sec. 62-942—62-951; Sec. 62-947; Sec. 62-948; Sec. 62-943; Sec. 62-944; Sec. 62-945; Sec. 62-946; Sec. 62-950; Sec. 62-952 |
| Street Clock (Building Corner Install) | Height 15–20 ft above sidewalk | — | — | Projection ≤5 ft from building face; height 15–20 ft above sidewalk. | Maximum 1 per place of business at a single location | Supported on the corner of a building/structure at intersection of two streets; must not project more than 5 ft from face/wall. | — | Unlock | Sec. 62-942—62-951; Sec. 62-949; Sec. 62-943; Sec. 62-944; Sec. 62-945; Sec. 62-946; Sec. 62-950; Sec. 62-952 |
Illumination rules, size formulas, and permit requirements for every sign type in Mc Alester are available with a free PermitPal account.
Start freeProhibited Signs in Mc Alester
- It is unlawful to erect, alter, or relocate any sign without first obtaining a sign permit.
- No sign extending over public property may be illuminated by floodlights or spotlights.
- No sign may obstruct ingress or egress from any door, window, or fire escape; no sign may be attached to a standpipe or fire escape.
- No sign may be erected where it obstructs clear vision at street intersections, interferes with or is confused with authorized traffic control devices, or uses words or symbols (e.g., “stop,” “drive-in,” “danger”) in a manner that misleads or confuses traffic.
- Display of obscene matter on any sign is unlawful.
- Signs constructed on or within five feet of a street line must have smooth surfaces; nails, tacks, or wires may not protrude (except electrical reflectors/devices may extend over the top and in front of the sign).
- Nonaccessory signs are prohibited on property adjoining Carl Albert Parkway and on all overpasses and underpasses over or under Carl Albert Parkway, and on all other overpasses and underpasses within city limits.
Exempt Signs in Mc Alester
- Real estate signs not exceeding 8 square feet that advertise only the sale, rental, or lease of the premises on which they are located.
- Professional nameplates not exceeding 2 square feet.
- Bulletin boards not over 8 square feet for public, charitable, or religious institutions when located on the premises of such institutions.
- Signs painted on the exterior surface of a building or structure; however, if such signs have raised borders, letters, characters, decorations, or lighting appliances, they are subject to the sign regulations.
- Signs denoting the architect, engineer, or contractor when placed upon work under construction and not exceeding 16 square feet.
- Occupational signs denoting only the name and profession of an occupant in a commercial building, public institutional building, or dwelling, and not exceeding 2 square feet.
- Memorial signs or tablets, names of buildings, and dates of erection when cut into masonry or constructed of bronze or other incombustible materials.
- Traffic or other municipal signs, legal notices, railroad crossing signs, danger signs, and temporary, emergency, or nonadvertising signs approved by the city council.
- Exempt signs remain subject to removal/repair provisions for unsafe or unlawful signs (section 62-641 applies).
Sign Plan & Submission Notes for Mc Alester
- No master sign plan or sign plan requirement is stated in the provided ordinance text.
- Variances to sign setbacks, area, height, and size may be approved by the Board of Adjustment upon appeal when strict application causes exceptional practical difficulties or undue hardship; the Board also hears appeals of administrative interpretations and enforcement.
- Projecting signs that exceed the standard area limits may be permitted only by special permission of the city council.
- Erecting a street clock on a public sidewalk requires special written permission of the city council, in addition to any required sign permits.
- Applications for signs with electrical wiring must be reviewed and approved by the electrical inspector before final approval or disapproval by the code administrator.
- Marquees and canopies must be designed by a structural engineer and approved by the code administrator and the electrical inspector.
- Permits for temporary signs authorize erection and maintenance for a period not exceeding 30 days.
- Sign permits expire if work authorized is not commenced within six months of issuance.