Sign Regulations in Beaverton, Oregon

Beaverton, Oregon has specific sign regulations covering 26 sign types across 9 zoning districts. Regulated sign types include Wall Sign, Awning Sign, Projecting Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: September 22, 2025

Sign Regulation Overview for Beaverton, Oregon

Sample Sign Requirements in Beaverton

Sign TypeMax HeightMax AreaSetback
Window Sign20% of interior window area per window; Downtown District: 40%
Flag Sign25' in Res zones (ground pole); 60' for non-res uses in Res zones; 45' in all other zones6' x 10'
Parking Lot Regulatory Sign8 ft6 sq ft

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for BeavertonFull Coverage

Sign Types Covered

26

  • Wall Sign
  • Awning Sign
  • Projecting Sign
  • Blade Sign
  • +2 more types

Zoning Districts

9

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Beaverton

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

Sign height limits in Beaverton vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Beaverton, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Beaverton, regulated sign types include Wall Sign, Awning Sign, Projecting Sign, Blade Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Beaverton vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Beaverton are regulated with specific requirements for brightness, animation, and message duration. Beaverton has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Beaverton Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Beaverton, Oregon sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Beaverton, Oregon Sign Rules at a Glance

Beaverton, Oregon regulates 26 sign types across 9 zoning districts. Temporary Portable Sign (in Public ROW)s in the Commercial Zones (NS, CS, CM-CS, CC, GC) zoning district are capped at 3 ft tall, 12 sq ft display area; 6 sq ft per face, and 28 inches wide (Sec. 60.40.45.4). Most commercial signs in Beaverton require a permit.

Detailed Sign Ordinance Requirements for Beaverton, Oregon

Sign Rules by Zoning District in Beaverton (9 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones525' in Res zones (ground pole); 60' for non-res uses in Res zones; 45' in all other zonesVaries, usually 32 sq ft
Commercial Zones (NS, CS, CM-CS, CC, GC)925' above grade (100% area); up to 1' below top of wall120 sq ft per sign; cumulative max per calculation method
Industrial Zones (IND)725' above grade (100% area); see top of wall restriction120 sq ft per sign; cumulative max per building
Office Zones (OI, OI-NC, OI-WS)825' above grade, 1' below top of wall120 sq ft per sign, total as per calculation
Multiple Use Zones (RC-BC, RC-MU, RC-DT, RC-OT, RC-E, OI-WS, C-WS, TC-MU, TC-HDR, CM-HDR, SC-MU, SC-HDR, SC-S, SC-E1, SC-E2, SC-E3)825' above grade; up to 1' below top of wall120 sq ft per sign, total max per formula
Residential Zones (MR, RMA, RMB, RMC, CM-MR, CM-RM)58 ft (if freestanding)32 sq ft per face
Downtown Regional Center Zones (RC-BC, RC-MU, RC-DT, RC-OT, RC-E)625' above grade (full area), 25% of sign area may be above 25' to 1' below top of wall120 sq ft per sign
Industrial Zones (Industrial Parks)18 ft32 sq ft per face (double-faced)
Residential Zones (CM-RM - Small-scale commercial use)625' max; 8' min cl.Max 120 sq ft per sign, total sign area for all signs on site 200 sq ft; add'l 100 sq ft if directional signage required

Zone-by-Zone Sign Requirements in Beaverton(sample of 3 of 9 zones)

Commercial Zones (NS, CS, CM-CS, CC, GC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign25' above grade (100% area); up to 1' below top of wall120 sq ft per sign; cumulative max per calculation methodOn exterior walls, up to 25' above grade (see also allocation to other walls)Unlock60.40.35.1 (A-E)
Awning Sign25'Included in wall sign totalOn awnings/canopies as part of building architectureUnlock60.40.35.2
Blade Sign25' clearance max, 8' min above sidewalk9 sq ft1 per tenant/leased spacePerpendicular to wall or on awnings. May project max 5', or within 2' of street curb (lesser)Unlock60.40.35.4
Freestanding Sign (NS, CC, OI, OI-NC, IND)8 ft64 sq ft total (all faces); 32 sq ft per face1 (plus extras per street frontage rules)On lot of record, outside right-of-wayUnlockTable 60.40.35.A
Freestanding Sign (CS, CM-CS, GC)15 ft64 sq ft total (all faces); 32 sq ft per face1 (plus extras per street frontage rules)On lot of record, outside right-of-wayUnlockTable 60.40.35.A
Electronic Message Center (EMC)Zone max freestanding sign height50% of max face area for one sign (32 sq ft/face) if part of allowed freestanding sign1 per qualified propertyAs component of a freestanding sign along arterial streets onlyUnlock60.40.50(2)(B)
Temporary Sign (Commercial, Industrial, Multiple Use zones)8 ft for sale/rent signsTypically 32 sq ft per face (for sale/lease), banners up to 32 sq ft, others per 60.40.45E.g. up to 1 per 100' frontage in right-of-way, or 1 per sale/lease, see temporary use detailsPrivate property or as permitted in right-of-wayUnlock60.40.45(3)
Temporary Portable Sign (in Public ROW)3 ft12 sq ft display area; 6 sq ft per face28 inches1 per 100' frontageWithin 20 ft of overhead light source, not in travel lanes/parking/bike paths/etc.Unlock60.40.45.4

Office Zones (OI, OI-NC, OI-WS)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign25' above grade, 1' below top of wall120 sq ft per sign, total as per calculationAnywhere on exterior wall, per codeUnlock60.40.35.1
Projecting Sign32 sq ft per face, 64 sq ft total1 per building (in-lieu of freestanding sign)Perpendicular to building wallUnlock60.40.35.3
Blade Sign25' clearance max, 8' min9 sq ft1 per tenant/leased spacePerpendicular to wall/awningUnlock60.40.35.4
Awning Sign25'Included in wall sign totalOn awnings/canopies of the buildingUnlock60.40.35.2
Freestanding Sign (OI, OI-NC)8 ft64 sq ft (total); 32 sq ft per face1, plus extras by frontageOn lot of recordUnlockTable 60.40.35.A
Freestanding Sign (OI-WS)15 ft64 sq ft (total); 32 sq ft per face1, plus extras by frontageOn lot of recordUnlockTable 60.40.35.B
Electronic Message Center (EMC)Zone max freestanding sign height16 sq ft per face (50% of 32 sq ft/face), on allowed freestanding signs only1 per property (if eligible)As component of a freestanding sign on arterial streetUnlock60.40.50(2)(B)
Temporary Sign8 ft for sale/rent signs32 sq ft/face typical for sale/rent or dev; 32 sq ft bannersOn private property or as permitted in ROWUnlock60.40.45(3)

Multiple Use Zones (RC-BC, RC-MU, RC-DT, RC-OT, RC-E, OI-WS, C-WS, TC-MU, TC-HDR, CM-HDR, SC-MU, SC-HDR, SC-S, SC-E1, SC-E2, SC-E3)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign25' above grade; up to 1' below top of wall120 sq ft per sign, total max per formulaAnywhere on exterior wall/facadeUnlock60.40.35.1
Awning Sign25'As per wall sign allowanceOn awning/canopyUnlock60.40.35.2
Projecting Sign32 sq ft per face, 64 sq ft per business1 (in-lieu of freestanding sign)May project up to 8', 2/3 of sidewalk width or within 2' of curbUnlock60.40.35.3
Blade Sign25' max, 8' min clearance9 sq ft1 per tenant/leased spacePerpendicular to wall/awningUnlock60.40.35.4
Freestanding Sign15 ft64 sq ft (all faces), 32 sq ft per face1, plus extras by frontage (see code)On lot of recordUnlockTable 60.40.35.B
Electronic Message Center (EMC)15 ft (zone max for freestanding sign)16 sq ft per face (50% of 32 sq ft), only as part of freestanding sign1 per qualifying propertyAs part of permitted freestanding sign on arterial streetUnlock60.40.50(2)(C)
Temporary Sign8 ft sale/rent32 sq ft per face for sale/lease/dev; banners to 32 sq ftPer use (sale/lease/new business/etc.)On site or in ROW per codeUnlock60.40.45(3)
Temporary Portable Sign (Downtown RC zones)3 ft12 sq ft display, 6 sq ft per face28 inchesPer number of entrances as definedWithin ROW along frontage; not in travel/ADA/parking/vision areasUnlock60.40.45.4.B.3

PermitPal covers all 9 zoning districts in Beaverton — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 9 zones for Beaverton — start free

Prohibited Signs in Beaverton

  • No person shall erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use or maintain any sign, or cause or permit the same to be done, contrary to or in violation of any of the provisions of Section 60.40 of this Code.
  • No person shall erect, construct or alter a sign, or permit the same to be done, unless a sign permit has been issued by the city, except as provided in Section 60.40.10.
  • The provisions of this Code shall not permit the erection or maintenance of any sign at any place or in any manner unlawful under any other federal, state, or local law. Where provisions conflict, the more restrictive prevails.
  • No sign is exempt from the provisions of Section 60.40.25 (Prohibited Signs) and Section 60.40.55 (Nonconforming and Illegal Signs).
  • Signs shall not be located within the public right-of-way unless otherwise allowed by a specific Code provision.
  • Temporary signs shall not be illuminated.
  • Temporary signs shall not be attached to trees, shrubbery, utility poles or traffic control signs or devices.
  • Temporary signs shall not be erected or maintained in a way which, by reason of their size, location or construction, constitutes a hazard to the public.
  • Temporary signs shall be located outside of the vision clearance area specified in Chapter 2 of the City Engineering Design Manual.
  • The following signs are expressly prohibited within city limits: Bench Sign, Billboard, Feather Sign, Flashing Sign, Obstructing Sign, Portable Sign (except where allowed as a temporary sign), Portable Electronic Message Center Sign, Roof Sign (except on single story buildings under certain conditions), Rotating or Revolving Sign, Trailer Sign, Video Sign.
  • Signs in vision clearance areas as established in Chapter 2 of the City Engineering and Design Manual.
  • Pennants, streamers, festoon lights and other similar devices with parts that are moved by the wind.
  • Signs attached to any tree or public utility pole, other than signs identified as exempt in Section 60.40.10.
  • Signs using bare-bulb illumination or lighted so that the immediate source of illumination is visible (excluding neon).
  • Signs using flame as a source of light.
  • Any sign which purports to be or is an imitation of or resembles an official traffic sign or signal.
  • Any sign which, by reason of its size, location, movement, content, coloring, or manner of illumination, may be confused with or construed as a traffic control device, or which blocks visibility of any traffic sign or signal.
  • Signs designed or used for the purpose of emitting sound or dispersing smells.
  • Inflatable signs, balloons greater than eight cubic feet, or similar devices.

Exempt Signs in Beaverton

  • Signs constructed or placed in a public right-of-way by or with the approval of a governmental agency having legal control of that right-of-way for the purpose of traffic control, transit, public safety and wayfinding.
  • Signs constructed or placed by public utility companies for the general purpose of providing information concerning a pole, line, pipe or other facility belonging to the public utility as an aid to public safety.
  • Signs that are placed outside and are not visible from public rights-of-way.
  • Public Art as defined in Section 2.03.245.A of the Beaverton City Code.
  • Street address identifiers (numbers or letters) of buildings.
  • Plaques, markers or banners placed by the city or city recognized agency or organization for the general purpose of recognizing historic significance or military service.
  • Signs allowed as part of a Special Event Permit, subject to separate regulation under Chapter 7, Section 7.05 of the Beaverton City Code.
  • Signs approved pursuant to the Open Air Beaverton program.
  • Signs required on tree protection fencing and soil protection fencing during construction as per Section 60.61.

Sign Plan & Submission Notes for Beaverton

  • No person shall erect, construct or alter a sign, or permit the same to be done, unless a sign permit has been issued by the city, except as provided in Section 60.40.10.
  • An application for sign permit approval is subject to the procedures set forth in Section 40.60 (Signs) of this Code.
  • The city may require as a condition of a sign permit that any and all unlawful signs on the applicant’s property be removed by a stated time.
  • For developments containing one or more businesses, a master sign program may be proposed by the property owner. Master sign programs shall contain the proposed colors, lettering styles, sizes and the location of wall and freestanding signs for tenants in the development.
  • Individual business signs which are part of a master sign program are subject to the permit application process.
  • Conditions of Temporary Use or Special Event approval shall govern the placement, type and duration of all temporary signs consistent with the approved signage plan.
  • Applications for Electronic Message Centers (EMCs) shall include a statement by a licensed engineer certifying that the lighting will comply with the lighting standards of this Code.
  • The City may require, as a condition of a sign permit or development approval on property with a preexisting nonconforming sign, that the nonconforming sign(s) be removed, reconstructed, or replaced.

Source: other municipal code