Bradford, Pennsylvania has specific sign regulations covering 25 sign types across 4 zoning districts. Regulated sign types include Ground Sign (Identification for public or semipublic buildings), Ground Sign (Business identification for legal nonconforming or special exception use), Ground Sign (Real estate, development, contractor). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 21, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Bradford, Pennsylvania
Sample Sign Requirements in Bradford
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Ground Sign (Identification for public or semipublic buildings) | 6 ft | 24 sq ft | See §178-23 for ground sign building line/setback/interference rules. |
| Ground Sign (Business identification for legal nonconforming or special exception use) | 6 ft | 24 sq ft | See §178-23 for ground sign requirements. |
| Ground Sign (Real estate, development, contractor) | 6 ft | 12 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
25
- Ground Sign (Identification for public or semipublic buildings)
- Ground Sign (Business identification for legal nonconforming or special exception use)
- Ground Sign (Real estate, development, contractor)
- Ground Sign (Temporary special event - public/nonprofit buildings)
- +2 more types
Zoning Districts
4
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Bradford
Other Cities in Pennsylvania
Frequently Asked Questions
In Bradford, the height limit for Ground Sign (General construction/safety) is 25 ft (Sec. 178-23). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Bradford require a permit. From the submission notes on this page: Billboards require submission of structural calculations certified by a registered engineer and advance approval from appropriate agencies (FAA, PennDOT if applicable) prior to the issuance of a sign permit. Run a code check for an exact address to see the permit requirements for that zone.
Bradford's sign code covers 25 sign types, including Ground Sign (Identification for public or semipublic buildings), Ground Sign (Business identification for legal nonconforming or special exception use), Ground Sign (Real estate, development, contractor), and Ground Sign (Temporary special event - public/nonprofit buildings). Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Noncommercial signs not exceeding 12 square feet placed upon private property by the owner or occupant. The full list is on this page.
In Bradford, Projecting Sign (C-1) in the Medical Center District (M-C) and other zoning districts must be set back at least 3 ft from curbline. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Bradford's sign ordinance that cover digital, changing, or flashing signs: Flashing or oscillating signs are not permitted. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Bradford Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Bradford, Pennsylvania, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Bradford, Pennsylvania Sign Rules at a Glance
Bradford, Pennsylvania regulates 25 sign types across 4 zoning districts. Ground Signs (Home occupation identification) in the Conservation District (C-D), Residential District (R-1, R-2, R-3) are capped at 6 ft tall and 1 sq ft (Sec. 220-119A(5)). Most commercial signs in Bradford require a permit.
Detailed Sign Ordinance Requirements for Bradford, Pennsylvania
Sign Rules by Zoning District in Bradford (4 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Conservation District (C-D), Residential District (R-1, R-2, R-3) | 7 | 6 ft | 40 sq ft | Not listed |
| Medical Center District (M-C), Commercial District (C-1, C-2), Industrial District (M-1, M-2) | 12 | 25 ft (see §178-23B(1)) | Cumulative: 300 sq ft (all wall signs) | Not listed |
| Industrial District (M-1, M-2) (Billboards only) | 1 | 40 ft above curb | 600 sq ft per face, 2 faces per billboard structure | Not listed |
| General Regulations For All Zones | 5 | see §178-27A(1): no more than 4 ft in one dimension | 500 sq ft per wall sign | Not listed |
Zone-by-Zone Sign Requirements in Bradford(sample of 3 of 4 zones)
Conservation District (C-D), Residential District (R-1, R-2, R-3)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Sign (Identification for public or semipublic buildings) | 6 ft | 24 sq ft | Not listed | See §178-23 for ground sign building line/setback/interference rules. | 1 per building | On property of public/semipublic building (church, school, library, etc.) | Not listed | Unlock | §220-119A(1), §178-23 |
| Ground Sign (Business identification for legal nonconforming or special exception use) | 6 ft | 24 sq ft | Not listed | See §178-23 for ground sign requirements. | 1 per use | On property of legal nonconforming/special exception use | Not listed | Unlock | §220-119A(2), §178-23 |
| Ground Sign (Real estate, development, contractor) | 6 ft | 12 sq ft | Not listed | Not listed | 1 per lot | On property for sale/rent/development or construction | Not listed | Unlock | §220-119A(3) |
| Ground Sign (Temporary special event - public/nonprofit buildings) | 6 ft | 40 sq ft | Not listed | Not listed | 1 per building | On face of public/nonprofit buildings | Not listed | Unlock | §220-119A(4) |
| Ground Sign (Home occupation identification) | 6 ft | 1 sq ft | Not listed | Not listed | 1 per home occupation | On property of approved home occupation | Not listed | Unlock | §220-119A(5) |
| Wall Sign (Identification for public or semipublic buildings) | Not listed | Not listed | Not listed | Not listed | 1 per wall | On wall of public/semipublic building | Not listed | Unlock | §220-119B(1), §178-24 |
| Wall Sign (Business identification - legal nonconforming or special exception use) | Not listed | Not listed | Not listed | Not listed | 1 per wall | On wall of nonconforming or special exception use | Not listed | Unlock | §220-119B(2) |
Medical Center District (M-C), Commercial District (C-1, C-2), Industrial District (M-1, M-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Marquee, Awning, Canopy | Not listed | Not listed | Marquee: entrance width + 5 ft each side; if entrances ≤20 ft apart, marquee may be continuous | See details for each mounting. | Not listed | Marquee: above entrance; Awning/Canopy: attached to building, over sidewalk/street/driveway | Not listed | Unlock | §220-120A, §178-28, §178-29 |
| Ground Sign (M-C, C-1) | 25 ft (see §178-23B(1)) | 60 sq ft | Not listed | See §178-23 (no part beyond property line or into ROW) | 1 per lot | On premises | Not listed | Unlock | §220-120B(2), §178-23 |
| Ground Sign (C-2, M-1) | 25 ft (see §178-23B(1)) | 100 sq ft | Not listed | See §178-23 | 1 per lot | On premises | Not listed | Unlock | §220-120B(3), §178-23 |
| Ground Sign (M-2) | 25 ft (see §178-23B(1)) | 200 sq ft per sign | Not listed | See §178-23 | 1 per entrance | Each entrance to business | Not listed | Unlock | §220-120B(4), §178-23 |
| Wall Sign (M-C, C-1) | Not listed | Cumulative: 100 sq ft (all wall signs) | Not listed | Not listed | Multiple, as long as cumulative area ≤ 100 sq ft | Building wall | Not listed | Unlock | §220-120C(1)-(2), §178-24 |
| Wall Sign (C-2, M-1) | Not listed | Cumulative: 150 sq ft (all wall signs) | Not listed | Not listed | Multiple, as long as cumulative area ≤ 150 sq ft | Building wall | Not listed | Unlock | §220-120C(3), §178-24 |
| Wall Sign (M-2) | Not listed | Cumulative: 300 sq ft (all wall signs) | Not listed | Not listed | Multiple, as long as cumulative area ≤ 300 sq ft | Building wall | Not listed | Unlock | §220-120C(4), §178-24 |
| Projecting Sign (C-1) | Not listed | Horizontal: 50 sq ft per side; Vertical: 100 sq ft per side | Projection max 2 ft from wall, min 8 ft above sidewalk, min 15 ft above driveways/alleys | No closer than 3 ft to curbline | 1 per building | One per building, C-1 only | Not listed | Unlock | §220-120E, §178-26 |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (General construction/safety) | Not listed | 500 sq ft per wall sign | Not listed | No sign to extend beyond wall/ends. | Not specified (see zone limits on area/quantity) | Attached to building exterior front/rear/side wall | Not listed | Unlock | §178-24 |
| Ground Sign (General construction/safety) | 25 ft | Not listed | Not listed | No part may extend beyond property line or into ROW or street line; min 2 ft from other sign/building/structure | See zone requirements | On ground, not attached to building | Not listed | Unlock | §178-23 |
| Temporary Sign (General) | see §178-27A(1): no more than 4 ft in one dimension | 100 sq ft | Not listed | Not listed | See applicable zone | On wall/other property; not to obstruct doors, windows, fire escape | Not listed | Unlock | §178-27 |
| Awning/Canopy (General requirements) | Not listed | Not listed | Awnings: unlimited width; Canopies: max 8 ft wide | Awnings/canopies 12 in inward from curb | Not listed | Attached to building | Not listed | Unlock | §178-29 |
| Street Clock (General) | Clock on wall or post: 15-20 ft above sidewalk, see §178-30B. On sidewalk: post at least 15 ft high | Not listed | Not listed | On sidewalk: not more than 20 in from curb, at least 20 ft from intersection, 15-20 ft height | 1 per business per location | On sidewalk (with permission) or attached to building at intersection | Not listed | Unlock | §178-30 |
PermitPal covers all 4 zoning districts in Bradford. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Bradford
- It is unlawful to erect, repair, alter, relocate or maintain any sign within the City of Bradford without first obtaining a permit, unless exempted.
- No sign shall obstruct free ingress to or egress from any door, window, or fire escape.
- No sign shall be attached to a standpipe or fire escape.
- No sign shall be located so as to prevent free ingress or egress from any door, window, or fire escape.
- No sign shall be attached to trees, utility poles, or official traffic control devices or within the public right-of-way.
- No sign that imitates traffic control devices is permitted.
- No sign shall be erected at street intersections in a manner that obstructs free and clear vision or interferes with, obstructs, or is confused with authorized traffic signs, signals, or devices, or uses misleading words or symbols such as 'Stop,' 'Look,' 'Danger,' etc.
- No sign shall be located in such a position that it will cause a traffic hazard by obstructing visibility for traffic or obscuring a traffic signal or control device.
- No sign, except official traffic signs, shall be erected or hang over or within the right-of-way of any street.
- No sign shall be located within the clear sight triangle as defined by the code.
- No sign or advertising structure may display any obscene matter as interpreted under federal or Pennsylvania case law.
- No sign shall be erected, relocated, or maintained so as to prevent free ingress or egress from doors, windows, or fire escapes, or be attached to a standpipe or fire escape.
- Signs attached to or affixed to vehicles and/or trailers parked on a public right-of-way or property other than the site they advertise, if the apparent purpose is to advertise a product or direct people to a business, are not permitted except for maintenance, repair, loading, unloading, or rendering a service.
- No sign shall be secured with wire, strips of wood, or nails, nor hung or secured to any other sign.
- V-shaped projecting signs consisting of two single-faced signs without a roof or ceiling are not permitted.
- It is unlawful to maintain any sign projecting over public property that is illuminated by floodlights or spotlights.
- Flashing or oscillating signs are not permitted.
- No illuminated sign shall be constructed or maintained that exceeds a maximum of 0.2 footcandle at the property line (for general signs); for billboards, not to exceed 1.0 footcandle on adjoining property.
- Billboards are prohibited outside of M-1 and M-2 Districts and subject to special distance and placement requirements.
- No billboard or sign shall flash or emit noise; display lighting for billboards shall not cause distraction, confusion, nuisance, or hazard to traffic, aircraft, or other properties.
- No sign or advertising structure may be erected, constructed, or maintained that creates a menace to public safety or is unsafe or insecure.
- No advertising shall be placed on any awning or canopy except for the name of the owner/business; said marking is restricted to a designated size.
- No sign shall be permitted to contain loose or frayed material protruding from the structure.
Exempt Signs in Bradford
- Temporary signs not exceeding 12 square feet, provided each sign is removed within 60 days of its erection.
- Identification signs not exceeding three square feet denoting only the name and profession of an owner or occupant.
- Signs painted on the exterior surface of a building or structure, provided they do not have raised borders, letters, decorations, or lighting appliances (if so, such signs are subject to further regulations).
- Bulletin boards not exceeding eight square feet in area advertising or informing of a service, business, occupation, or profession on the property.
- Signs cut into masonry surfaces or constructed of bronze or other incombustible materials denoting the name or identifying information of a building or its date of construction.
- Traffic or other municipal signs, legal notices, railroad crossing signs, danger and such emergency or nonadvertising signs as approved by the City Council.
- Noncommercial signs not exceeding 12 square feet placed upon private property by the owner or occupant.
Sign Plan & Submission Notes for Bradford
- An erection permit is required for almost all signs, which involves submitting detailed plans (blueprints or ink drawings, construction methods, stress calculations, etc.) per §178-3 and §178-4.
- All illuminated signs require plan review and approval by the Electrical Inspector before issuance of the erection permit.
- For projecting signs, marquees, and canopies, plans must be designed by a structural engineer and approved by the Building Inspector for compliance with the Building Code.
- Billboards require submission of structural calculations certified by a registered engineer and advance approval from appropriate agencies (FAA, PennDOT if applicable) prior to the issuance of a sign permit.
- A sign permit application must include all information required by §178-4 and is subject to review and approval; denial requires a written statement citing specific requirements not met.
- Failure to obtain a sign permit is a violation subject to penalties (§178-34, §220-146E).
- Signage that exceeds standard limitations, or involves special exceptions (e.g., oversized projecting signs), may require special permission or approval from the City Council.
- Ongoing inspections are permitted at several stages (prior to installation, after installation, subsequent maintenance, response to complaints, upon modification, or cessation of use).
- All signs (unless specifically exempted) are subject to review and compliance review to ensure conformity with all applicable codes, including Chapter 178 (Sign Regulations) and Article XVI of the Zoning Code.
- There is no reference to a 'Master Sign Plan' or a requirement for a unified or master sign plan for multiple-tenant developments, but detailed erection plans/specifications for each sign are required for the permit.