Foster Township, Pennsylvania has specific sign regulations covering 11 sign types across 6 zoning districts. Regulated sign types include Business Sign, Business Pylon Sign (Shopping Center/Land Development), Identification Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Sign Regulation Overview for Foster Township, Pennsylvania
Sample Sign Requirements in Foster Township
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Identification Sign | If freestanding: 10 ft; If wall-mounted: no higher than first story | 2 sq ft | 10 ft from front lot line |
| Real Estate Sign | — | 8 sq ft | 10 ft from front lot line |
| Subdivision/Development Advertising Sign | — | 60 sq ft | 35 ft from front lot line |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
11
- Business Sign
- Business Pylon Sign (Shopping Center/Land Development)
- Identification Sign
- Real Estate Sign
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Foster Township
Other Cities in Pennsylvania
Frequently Asked Questions
Sign height limits in Foster Township vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.
To get a sign permit in Foster Township, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Foster Township, regulated sign types include Business Sign, Business Pylon Sign (Shopping Center/Land Development), Identification Sign, Real Estate Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Foster Township vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Foster Township are regulated with specific requirements for brightness, animation, and message duration. Foster Township has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Foster Township Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Foster Township, Pennsylvania sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Foster Township, Pennsylvania Sign Rules at a Glance
Foster Township, Pennsylvania regulates 11 sign types across 6 zoning districts. Identification Signs in the General Regulations For All Zones zoning district are capped at If freestanding: 10 ft; If wall-mounted: no higher than first story tall and 2 sq ft, with a 10 ft from front lot line setback (Sec. § 255-1001A(1), § 255-1004A, § 255-1003A, § 255-1011). Most commercial signs in Foster Township require a permit.
Detailed Sign Ordinance Requirements for Foster Township, Pennsylvania
Sign Rules by Zoning District in Foster Township (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 7 | If freestanding: 10 ft; If wall-mounted: no higher than first story | 60 sq ft | — |
| B-2, A-1, C-1 | 2 | 18 ft | 300 sq ft | — |
| B-3 | 2 | 18 ft | 300 sq ft | — |
| S-1 | 2 | 18 ft | 300 sq ft | — |
| I-1, I-2 | 3 | 18 ft | 300 sq ft | — |
| PRD | 1 | — | 60 sq ft | — |
Zone-by-Zone Sign Requirements in Foster Township(sample of 3 of 6 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Identification Sign | If freestanding: 10 ft; If wall-mounted: no higher than first story | 2 sq ft | — | 10 ft from front lot line | Max 2 per property (excluding directional/informational and business signs within a shopping center); 3 allowed on corner lots (§ 255-1004J) | On owner's lot, min. 10 ft front setback | — | Unlock | § 255-1001A(1), § 255-1004A, § 255-1003A, § 255-1011 |
| Real Estate Sign | — | 8 sq ft | — | 10 ft from front lot line | Max 2 per property (excluding directional/informational signs); 3 on corner lots (§ 255-1004J) | On lot being offered for sale/rental, min. 10 ft front setback | — | Unlock | § 255-1001A(4), § 255-1004C, § 255-1003C, § 255-1011 |
| Subdivision/Development Advertising Sign | — | 60 sq ft | — | 35 ft from front lot line | 1 per subdivision | On subdivision/PRD property; min. 35 ft front setback | — | Unlock | § 255-1001A(5), § 255-1004D, § 255-1003D, § 255-1011 |
| Institutional Sign | Max as for principal structure in district | 50 sq ft | — | 10 ft from front lot line | Max 2 per property (excluding directional/informational and business signs within a shopping center); 3 allowed on corner lots (§ 255-1004J) | On institution's property, min. 10 ft from front lot line | — | Unlock | § 255-1001A(6), § 255-1004E, § 255-1003E, § 255-1011 |
| On-site Directional and/or Informational Sign | 6 ft | 6 sq ft | — | 5 ft from any yard line | Excluded from general sign limit (§ 255-1004J) | On property, min. 5 ft setback from any yard | — | Unlock | § 255-1001A(7), § 255-1004F, § 255-1003F, § 255-1011 |
| Subdivision/Development Identification Sign | — | 10 sq ft | — | 10 ft from front lot line | Max 1 per entrance | At entrance to subdivision/development; min. 10 ft front setback | — | Unlock | § 255-1001A(8), § 255-1004H, § 255-1003H, § 255-1011 |
| Event Sign | — | 6 sq ft | 2 ft by 3 ft | — | Max 2 per property (excluding directional/informational and business signs within a shopping center); 3 allowed on corner lots (§ 255-1004J) | Not in public right-of-way or attached to trees/utility poles/structures within ROW | — | Unlock | § 255-1001A(9), § 255-1004I, § 255-1003I, § 255-1011 |
B-2, A-1, C-1
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Business Sign | 18 ft | 32 sq ft | — | Front: >=25% of district principal structure front setback or 10 ft minimum; if existing building <10 ft, attach as wall sign flat against building | Max 2/property (excludes directional/informational and shopping center pylon); 3 on corner lots (§ 255-1004J) | On business's lot. If setback <10 ft, must be wall-mounted flat against building; otherwise, must have at least 25% of principal building front yard setback or 10 ft, whichever is greater | — | Unlock | § 255-1001A(2), § 255-1004B(1)(a),(c),(d), § 255-1003B, § 255-1004B(3)-(4), § 255-1005, § 255-1011 |
| Business Pylon Sign (Shopping Center/Land Development) | 18 ft | 300 sq ft | — | >=25% of principal setback or 10 ft min | 1 per shopping center lot | One per shopping center lot | — | Unlock | § 255-1004B(2),(4), § 255-1003B, § 255-1011 |
I-1, I-2
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Business Sign | 18 ft | 100 sq ft | — | Front: >=25% of district principal structure front setback or 10 ft minimum; if existing building <10 ft, attach as wall sign flat against building | Max 2/property (excludes directional/informational and shopping center pylon); 3 on corner lots (§ 255-1004J) | On business's lot. If setback <10 ft, must be wall-mounted flat against building; otherwise, must have at least 25% of principal building front yard setback or 10 ft, whichever is greater | — | Unlock | § 255-1001A(2), § 255-1004B(1)(f)(g), § 255-1003B, § 255-1004B(3)-(4), § 255-1005, § 255-1011 |
| Business Pylon Sign (Shopping Center/Land Development) | 18 ft | 300 sq ft | — | >=25% of principal setback or 10 ft min | 1 per shopping center lot | One per shopping center lot | — | Unlock | § 255-1004B(2),(4), § 255-1003B, § 255-1011 |
| Billboard Sign or Off-premise Advertising Sign | Not above district's height max for principal structures | 300 sq ft per panel (double-faced allowed, only one per structure) | — | Min. 300 ft from highway/state legislative route centerline; min. 200 ft from residential; min. 1,000 ft between billboards | One double-faced per structure | Must not be within 200 ft of any residential structure or zone. Not attached to a building. | — | Unlock | § 255-1001A(3), § 255-1003G, § 255-1004G, § 255-1011 |
PermitPal covers all 6 zoning districts in Foster Township — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 6 zones for Foster Township — start freeProhibited Signs in Foster Township
- Signs that are located in such a position which endangers vehicular and/or pedestrian traffic by obscuring the sight distance.
- Signs which by design and/or location may be confused with traffic signs or signals.
- Any sign located in or extending into a public right-of-way, including sidewalk areas, except an official street sign or traffic control sign.
- Any freestanding or projecting sign within an area bounded by the intersection of two public or private streets, for a distance of 20 feet along the center line of the right-of-way of such streets from the point of their intersection.
- Freestanding or projecting signs over any type of public right-of-way, including sidewalk areas.
- Sequential, flashing or oscillating signs.
- Signs which due to their construction and/or location would constitute a hazard or a potential danger to the community.
Exempt Signs in Foster Township
- Official street signs or traffic control signs are exempt from prohibitions against being located in or extending into a public right-of-way.
- Real estate signs and subdivision/land development signs are exempt from the zoning permit requirement if they do not exceed eight square feet in surface area.
Sign Plan & Submission Notes for Foster Township
- An Overhead Banner Request Application Form (Exhibit A) must be submitted to the Township for the erection of overhead banners over public roadways, designating size, description, events/organizations, and installation dates.
- A zoning permit is required for the erection, alteration or relocation of any sign that exceeds eight square feet in surface area, except for real estate signs and subdivision/land development signs.