Sign Regulations in Kemp, Texas
Kemp, Texas has specific sign regulations covering 6 sign types across 2 zoning districts. Regulated sign types include Freestanding Sign, Monument Sign, Attached Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 8, 2025
Sign Regulation Overview for Kemp, Texas
Sample Sign Requirements in Kemp
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Freestanding Sign | 22 feet (up to 35 feet by variance where visibility is affected by elevated highways); up to 75 feet if on US Highway Business 175 or State Highway 274 within 1,800 feet | 40 square feet | — |
| Monument Sign | 7 feet (measured from the top of adjacent curb) | — | 20 ft from property line adjacent to street; 10 ft from property line abutting nonresidential/multifamily; 20 ft from side abutting single-family |
| Attached Sign | No higher than roof line (for one-story); no higher than floor of second story (for first floor of multi-story); for second floor or 2-story, no higher than roof line; for multi-story, no higher than floor of third story | 40 square feet or 30% of signable area (whichever is less) | — |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
6
- Freestanding Sign
- Monument Sign
- Attached Sign
- Portable Sign
- +2 more types
Zoning Districts
2
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Kemp
Frequently Asked Questions
In Kemp, monument signs are limited to 22 feet (up to 35 feet by variance where visibility is affected by elevated highways); up to 75 feet if on US Highway Business 175 or State Highway 274 within 1,800 feet. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.
To get a sign permit in Kemp, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Kemp, regulated sign types include Freestanding Sign, Monument Sign, Attached Sign, Portable Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Kemp vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Kemp are regulated with specific requirements for brightness, animation, and message duration. Kemp has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Kemp Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Kemp, Texas sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Kemp, Texas Sign Rules at a Glance
Kemp, Texas regulates 6 sign types across 2 zoning districts. Freestanding Signs in the Commercial District, Industrial District, Manufacturing/Industrial District zoning district are capped at 22 feet (up to 35 feet by variance where visibility is affected by elevated highways); up to 75 feet if on US Highway Business 175 or State Highway 274 within 1,800 feet tall and 40 square feet (Sec. Sec. 30-25, Sec. 30-54, Sec. 30-55). Most commercial signs in Kemp require a permit.
Detailed Sign Ordinance Requirements for Kemp, Texas
Sign Rules by Zoning District in Kemp (2 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Commercial District, Industrial District, Manufacturing/Industrial District | 4 | 22 feet (up to 35 feet by variance where visibility is affected by elevated highways); up to 75 feet if on US Highway Business 175 or State Highway 274 within 1,800 feet | 40 square feet | — |
| General Regulations For All Zones | 2 | — | 10 square feet for single tenant buildings; 6 square feet for multiple tenant buildings | — |
Zone-by-Zone Sign Requirements in Kemp
Commercial District, Industrial District, Manufacturing/Industrial District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign | 22 feet (up to 35 feet by variance where visibility is affected by elevated highways); up to 75 feet if on US Highway Business 175 or State Highway 274 within 1,800 feet | 40 square feet | — | — | 1 per site unless auxiliary; 2 monument signs in lieu if frontages on two non-intersecting streets | On-premises, upon commercial or industrial zoned property | — | Unlock | Sec. 30-25, Sec. 30-54, Sec. 30-55 |
| Monument Sign | 7 feet (measured from the top of adjacent curb) | — | — | 20 ft from property line adjacent to street; 10 ft from property line abutting nonresidential/multifamily; 20 ft from side abutting single-family | Up to 2 if site fronts two non-intersecting streets | On-premises; at least 20 ft from frontage property line adjacent to street; at least 10 ft from property line abutting nonresidential or multifamily use; 20 ft from side property line abutting single-family residence | — | Unlock | Sec. 30-116 |
| Attached Sign | No higher than roof line (for one-story); no higher than floor of second story (for first floor of multi-story); for second floor or 2-story, no higher than roof line; for multi-story, no higher than floor of third story | 40 square feet or 30% of signable area (whichever is less) | — | — | 1 per occupied facade per activity; up to 2 per building for single activity with multiple street frontages | On building facade occupied by activity; on public entrance/frontage; must be attached to building wall, canopy fascia, or sign band | — | Unlock | Sec. 30-84, Sec. 30-85, Sec. 30-86 |
| Portable Sign | — | — | — | — | — | On-premises, commercial or industrial zoned property | — | Unlock | Sec. 30-25 |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Non-illuminated Address Number / Placard | — | 10 square feet for single tenant buildings; 6 square feet for multiple tenant buildings | — | — | — | On building | — | Unlock | Sec. 30-85(b) |
| Attached Sign (Prohibited Type) | — | — | — | — | — | On a wall or building where sign face is not parallel to mounting surface | — | Unlock | Sec. 30-86 |
Illumination rules, size formulas, and permit requirements for every sign type in Kemp are available with a free PermitPal account.
Start freeProhibited Signs in Kemp
- All on-premises signs must be designed and constructed to withstand a wind pressure of not less than 30 pounds per square foot of area and must be constructed to receive dead loads as required by the building code or other ordinances of the city.
- No freestanding sign shall project beyond the roof or parapet wall lines of a building located on the same site, except by variance.
- Projecting signs which are mounted on a wall or a building or other architectural element in such a manner that the sign face is not parallel with the face of the wall, building or other architectural element to which the sign is mounted will be prohibited.
Exempt Signs in Kemp
- Non-illuminated street address numbers and placards which identify the activity may be used in addition to other attached signs, subject to area limitations.
Sign Plan & Submission Notes for Kemp
- No indication of a requirement for master sign plan, sign plan, or variance meeting except that variances may be requested for height increases for certain freestanding signs.
Source: municode municipal code