Killeen, Texas has specific sign regulations covering 21 sign types across 8 zoning districts. Regulated sign types include Wall Sign, Projecting Wall Sign, Ground Sign - Single or Multi-Tenant Monument. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Killeen, Texas

Sample Sign Requirements in Killeen

Sign TypeMax HeightMax AreaSetback
Wall Sign672 sq ft per sign
Projecting Wall Sign32 sq ft
Ground Sign - Single or Multi-Tenant Monument6 ft50 sq ftNo minimum setback

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for KilleenFull Coverage

Sign Types Covered

21

  • Wall Sign
  • Projecting Wall Sign
  • Ground Sign - Single or Multi-Tenant Monument
  • Ground Sign - Single Tenant Ground or Pole
  • +2 more types

Zoning Districts

8

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Killeen

City WebsiteMunicipal Code6 permit application links available

Frequently Asked Questions

In Killeen, monument signs are limited to 6 ft. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Killeen, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Killeen, regulated sign types include Wall Sign, Projecting Wall Sign, Ground Sign - Single or Multi-Tenant Monument, Ground Sign - Single Tenant Ground or Pole, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Killeen, monument signs typically require a No minimum setback setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Killeen are regulated with specific requirements for brightness, animation, and message duration. Killeen has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Killeen Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Killeen, Texas sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Killeen, Texas Sign Rules at a Glance

Killeen, Texas regulates 21 sign types across 8 zoning districts. Ground Sign - Single or Multi-Tenant Monuments in the B-1, B-2, NBD zoning district are capped at 6 ft tall, 50 sq ft, and 16 ft (if subdivision entrance, per 31-503(8)) wide, with a No minimum setback setback (Sec. Sec. 31-507(A)(1), Table 507(A)(1)). Most commercial signs in Killeen require a permit.

Detailed Sign Ordinance Requirements for Killeen, Texas

Sign Rules by Zoning District in Killeen (8 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
B-1, B-2, NBD840 ft672 sq ft per sign
B-3, B-3A330 ft672 sq ft per sign
B-4135 ft378 sq ft
B-5142.5 ft672 sq ft (face height max 25 ft, length max 60 ft)
B-C-1, RC-1, B-DC, UD, CD, M-1, M-22See Table 507(A)(1): 6 ft (monument), 35 ft (single-tenant), 40 ft (multi-tenant)672 sq ft per sign
R-MP, R-3, R-3F, R-3A132 sq ft per principal entrance
SR-1, SR-2, R-1, SF-2, RT-1, R-2, RM-1, R-MS, R-3, R-3F, R-3A, A, AR-1, A-R1120 ft50 sq ft
General Regulations For All Zones6Off-premises: 48 in672 sq ft

Zone-by-Zone Sign Requirements in Killeen(sample of 3 of 8 zones)

B-1, B-2, NBD

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign672 sq ft per signAffixed to or painted on the wall or surface of any building or structure, projecting no more than 12 inches from the building/structureUnlockSec. 31-506, Sec. 31-507(A), Sec. 31-507(A)(8)
Projecting Wall Sign32 sq ftOne, only if maximum ground sign not usedMay project no closer than 2 feet to a street curb, may be used only if maximum ground sign not usedUnlockSec. 31-506(2)
Ground Sign - Single or Multi-Tenant Monument6 ft50 sq ft16 ft (if subdivision entrance, per 31-503(8))No minimum setbackOne per premises, one additional per 300 ft additional frontageWithin premises, not in public right-of-way or easementsUnlockSec. 31-507(A)(1), Table 507(A)(1)
Ground Sign - Single Tenant Ground or Pole35 ft300 sq ftMinimum 10 ftSee one per premises rule aboveWithin premises, not in public right-of-way or easementsUnlockSec. 31-507(A)(1), Table 507(A)(1)
Ground Sign - Multi-Tenant Ground or Pole40 ft450 sq ftMinimum 10 ftSee one per premises rule aboveWithin premises, not in public right-of-way or easementsUnlockSec. 31-507(A)(1), Table 507(A)(1)
Portable Sign5 ft60 sq ft (5 ft x 12 ft)12 ftOneNot in required parking spaces. Only in place of a ground sign not otherwise used.UnlockSec. 31-507(A)(7)
EMD (Electronic Message Display) Wall SignUp to 336 sq ft (if allowable wall sign size is max 672 sq ft per sign)Permissible only on principal arterial, minor arterial, or collector where not within 300 ft of residential district unless non-residential use.UnlockSec. 31-506(4)
EMD Ground SignAs per corresponding ground sign type.Up to half of allowable ground sign size (e.g., 25, 150, or 225 sq ft, depending on sign type)Must meet regulations for ground sign type.UnlockSec. 31-507(A)(8)

B-3, B-3A

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign672 sq ft per signAffixed to or painted on the wall or surface of any building or structure, projecting no more than 12 inches from the building/structureUnlockSec. 31-506; Sec. 31-507(A, B)
Ground Sign - All types6 ft (monument), 35 ft (single-tenant), 40 ft (multi-tenant)See Table 507(A)(1): 50 sq ft (monument), 300 sq ft (single-tenant ground/pole), 450 sq ft (multi-tenant ground/pole)See Table 507(A)(1): 0 or 10 ft, depending on sign type.One per premises, plus one per additional 300 ft of street frontageWithin premises, not in ROW or easementsUnlockSec. 31-507(A-B)
Off-Premises Ground Sign - Small30 ft287 sq ft15 ft from property line or more stringent requiredPer minimum spacingOnly permitted on collector, minor, or principal arterials. Distance between signs must be greater than 300 ft.UnlockSec. 31-507(B)(8)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign - General672 sq ftBuilding wall, max 12 in projectionUnlockSec. 31-506, 31-503
Temporary Signs (General)Off-premises: 48 inWall: 32 sq ft; Off-premises: 24 in x 36 in (6 sq ft); Construction: 6 sq ft (res), 32 sq ft (com)On premises of event/lease/etc.; off-premises: private property, >30 ft from other signUnlockSec. 31-503(1,7,10), 31-504
FlagContained entirely on owner's property, spaced at least 25 ft apart.UnlockSec. 31-503(5)
Subdivision Entrance Sign (Temporary, post plat approval)12 ft overall64 sq ft16 ft overallOne per entranceOne per subdivision entrance after released for construction.UnlockSec. 31-503(8)
Political Sign (Residential/Nonresidential Election Period)8 ft6 sq ft (res < 1 acre); 36 sq ft (res > 1 acre, commercial)Private property, not in right-of-way.UnlockSec. 31-503(10)
Parking Lot Pole-Mounted Banner16 sq ft per pole (local street); 48 sq ft per pole (arterial), additional interior banners at same size, 1/pole.Limited by pole separationPermanent poles 2" diameter or larger, 50 ft apart minimum at street frontageUnlockSec. 31-503(12)

PermitPal covers all 8 zoning districts in Killeen — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 8 zones for Killeen — start free

Prohibited Signs in Killeen

  • It shall be unlawful to erect, maintain, or allow to remain any sign except as allowed by this division.
  • It shall be unlawful to erect, maintain, or allow to remain signs located on public right-of-way or within the visibility triangle at all intersections, except signs allowed by specific exceptions.
  • It shall be unlawful to erect, maintain, or allow to remain any flashing sign, strobe, or lights unless specifically allowed in this division.
  • It shall be unlawful to erect, maintain, or allow to remain signs which have a luminance greater than any traffic signal within two hundred (200) feet of the sign as measured by any light metering device for which a National Bureau of Standards test procedure exists.
  • It shall be unlawful to erect, maintain, or allow to remain signs that occupy a parking space required by the minimum standards provided under article V, division 3 of this chapter.
  • It shall be unlawful to erect, maintain, or allow to remain signs attached to any fence or property boundary walls except for signs denoted in section 31-503(9) and section 31-503(10).
  • It shall be unlawful to erect, maintain, or allow to remain banners, pennants, streamers, tinsel, staked signs, stringed signs or temporary signs, unless specifically allowed in another section of this division.
  • It shall be unlawful to erect, maintain, or allow to remain illegal signs, unanchored signs or signs in such condition as to constitute a threat to the health, safety, and welfare of the public.
  • It shall be unlawful to erect or maintain electrical signs which do not comply with the adopted electrical code.
  • No sign shall be erected so as to obstruct any fire escape, required exit, window or door opening intended as a means of egress.
  • No sign shall be erected which interferes with any opening required for ventilation.
  • Signs and their supporting structures shall maintain clearance and noninterference with all surface and underground facilities and conduits for water, sewage, gas, electricity, or communications equipment or lines.
  • No sign shall be located within any public use easement as measured from a vertical plane which extends infinitely upward from the edge of the easement nearest the sign, except as permitted under provisions of section 31-506(2), (3).
  • Signs shall maintain all clearances from electrical conductors in accordance with the city electrical code and from all communications equipment or lines located within the city.
  • No electrical equipment or apparatus of any kind which causes interference with radio or television reception shall be used in the operation of illuminated signs.
  • No person shall maintain or allow to be maintained any dilapidated, deteriorated or abandoned sign as defined in the ordinance.
  • No sign shall remain free of advertising copy face for more than sixty (60) consecutive days and shall be kept clean and free of graffiti or outdated commercial or advertising information.

Exempt Signs in Killeen

  • Signs allowed in Section 31-503 are permitted in any zoning district without a permit. These include: certain real estate signs, name/address signs, entrance door signs, drive entrance signs, flags (conditions apply), bench signs, construction/renovation signs, subdivision construction signs, signs or commemorative plaques of a public or noncommercial nature, certain election signs (conditions apply), polling place signs under specific restrictions, and parking lot pole-mounted banner signs as specified.
  • Official traffic-control signs, official governmental markers, national, state, city, or educational institution flags, and governmental signs are not considered 'signs' and are exempt.
  • Maintenance of existing (lawful, nonconforming) signs is allowed as a matter of right as a legal nonconforming use, subject to compliance with section 31-521.
  • Routine maintenance or repair and/or replacement of sign face copy on off-premises signs does not require a new permit.
  • Repair of an existing fence with like materials and no change to the original design or placement for up to 25 feet in a 12-month period is allowed without a permit (fences).

Sign Plan & Submission Notes for Killeen

  • A sign permit application must include a site plan and elevation drawings of the proposed sign, as well as other plans and information detailed in Sec. 31-515(A).
  • Each ground sign shall be permitted separately. Wall signs shall be permitted as a group per each side of the building (Sec. 31-515(B)).
  • Whenever a proposed sign is included in the presentation of a new or amended site plan application, for a development which requires planning and zoning commission approval, the sign permit application shall be reviewed and approved by the executive director of planning and development prior to the issuance of a permit (Sec. 31-516).
  • Except for portable and temporary signs, a plan review fee according to the adopted fee schedule shall be paid for each sign permit application submitted for review (Sec. 31-517).
  • For portable signs, an adequate site plan must be submitted with the application to locate the sign (Sec. 31-507(A)(7)c).
  • Stamped structural engineering plans shall accompany the sign permit application for any sign installed 20 feet or more in height and/or having a sign area (including the sign cabinet or frame) of 200 square feet or more (Sec. 31-515(A)(4)), and for certain off-premises signs per 31-507(B)(2)d.
  • For off-premises signs (including CEVMS), the city may require master sign plan documentation including location and size details.
  • When a proposed sign is part of a site plan submitted for planning/zoning approval (for example: new development, PUDs, or other projects requiring commission approval), a sign plan must be included and reviewed before permits are issued.