Sign Regulations in Nacogdoches, Texas

Nacogdoches, Texas has specific sign regulations covering 27 sign types across 6 zoning districts. Regulated sign types include Freestanding Sign, Wall Sign, Awning Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Nacogdoches, Texas

Sample Sign Requirements in Nacogdoches

Sign TypeMax HeightMax AreaSetback
Construction Sign (R-1, R-2, R-3, R-4, B-2)16 square feet
Construction Sign (All other zones)32 square feet
Real Estate Sign16 square feet (properties <= 2 acres); 32 square feet (properties > 2 acres)

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for NacogdochesFull Coverage

Sign Types Covered

27

  • Freestanding Sign
  • Wall Sign
  • Awning Sign
  • Construction Sign (R-1, R-2, R-3, R-4, B-2)
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Nacogdoches

City WebsiteMunicipal Code3 permit application links available

Frequently Asked Questions

Sign height limits in Nacogdoches vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Nacogdoches, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Nacogdoches, regulated sign types include Freestanding Sign, Wall Sign, Awning Sign, Construction Sign (R-1, R-2, R-3, R-4, B-2), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Nacogdoches vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Nacogdoches are regulated with specific requirements for brightness, animation, and message duration. Nacogdoches has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Nacogdoches Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Nacogdoches, Texas sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Nacogdoches, Texas Sign Rules at a Glance

Nacogdoches, Texas regulates 27 sign types across 6 zoning districts. Freestanding Signs in the B-1, B-3, historic district-downtown historic district, M zoning district are capped at 35 feet (up to 50 feet certain commercial zones with extra setback) tall and Per Table 2 (see below), with a No closer than 1.5 feet from back of curb per 1 foot of total sign height and at least 12 feet from curb setback (Sec. Sec. 78-98(3), Sec. 78-101). Most commercial signs in Nacogdoches require a permit.

Detailed Sign Ordinance Requirements for Nacogdoches, Texas

Sign Rules by Zoning District in Nacogdoches (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones48 feet36 square feet
R-3, R-4, A812 feet (measured from ground to top)60 square feet
B-1, B-3, historic district-downtown historic district, M1135 feet (up to 50 feet certain commercial zones with extra setback)300 square feet
industrial zoning districts435 feet (subject to Table 1 notes)300 square feet
B-2 commercial zoning districts335 feet (or up to 50 feet with 100 ft setback and 100+ ft frontage on certain roads)100 square feet
planned development districts1

Zone-by-Zone Sign Requirements in Nacogdoches(sample of 3 of 6 zones)

R-3, R-4, A

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Subdivision Identification Sign (Entrance with Median)60 square feet2 per entrance (with median)Two per neighborhood/subdivision/development entrance with medianUnlockSec. 78-97(a)(2)
Subdivision Identification Sign (Entrance without Median)60 square feet1 per entrance (no median)One per neighborhood/subdivision/development entrance without medianUnlockSec. 78-97(a)(2)
Entrance Identification Sign (Apartment, Mobile Home, Condo)60 square feet1 per entrance; 2 if second entrance on different streetOne per complex entrance; second permitted if complex has a second entrance on another streetUnlockSec. 78-97(a)(3)
Low-Profile Sign (Nonresidential Use incl. Churches/Synagogues)60 square feet1UnlockSec. 78-97(a)(4)
Wall Sign (Nonresidential Use incl. Churches/Synagogues)60 square feet1UnlockSec. 78-97(a)(4)
Low-Profile Sign (R-3 and R-4 only)5 feet60 square feet12 feet from any public right-of-wayUnlockSec. 78-97(b)(1)
Identification Signs (Subdivision/Apartment/Mobile Home/Condo/Church/Synagogue)UnlockSec. 78-97(b)(2)
Feather Sign (Multifamily - R-4 only)12 feet (measured from ground to top)20 square feetNo more than 4 feather sign permits per occupancy per yearMust not create obstruction/hazard; not within right-of-way; not located in historic district-downtown historic districtUnlockSec. 78-97(c)

B-1, B-3, historic district-downtown historic district, M

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign35 feet (up to 50 feet certain commercial zones with extra setback)Per Table 2 (see below)No closer than 1.5 feet from back of curb per 1 foot of total sign height and at least 12 feet from curb1 primary; 1 additional per street frontage, not exceeding size limitsUnlockSec. 78-98(3), Sec. 78-101
Wall Sign300 square feetPer occupancy per frontageOn building frontageUnlockSec. 78-98(4), (5)
Gas Station Canopy SignLettering/logo max 2 feet30 square feetOn gas station canopiesUnlockSec. 78-98(7)
Banner SignVariable by frontage (0–100 ft: 25 sq ft; 101–200: 50 sq ft; 201–300: 75 sq ft; 301–400: 100 sq ft; 401–500: 125 sq ft; 501–600: 150 sq ft)12 ft from back of curb or property line1 per building face visible from right-of-way at a timeMounted on building face, 1 per visible façade at a timeUnlockSec. 78-98(8)
Under-Canopy SignNot to exceed 40% of the total elevation area1 per elevationUnder-canopy, 1 per elevationUnlockSec. 78-98(9)
Temporary Changeable Advertisement12 ft from back of curb or property line1 at a timeSecurely fastened to permanent structure; at least 12 feet from back of curb or property lineUnlockSec. 78-98(11)
Pole BannerMax 20 ft; bottom at least 14 ft above grade24 sq ft per poleNo more than 2 per pole; total not to exceed 1 per 50 parking spacesOn privately owned poles; not on public utility or street light poles; periphery/interior up to 12 ft from property lineUnlockSec. 78-98(12)
Balloon/Inflatable SignMin 12 ft from back of curb or property line1 per year per occupancyNot in or blowing onto right-of-way; not on public property without written consentUnlockSec. 78-98(13)

industrial zoning districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign35 feet (subject to Table 1 notes)Per Table 1 in Sec. 78-101No closer than 1.5 ft from curb per 1 ft of sign height and at least 12 ft from curb1 per premises plus one additional per additional main street frontageUnlockSec. 78-99(2), 78-101
Wall Sign300 square feet1 per frontageOn buildingUnlockSec. 78-99(3), (4)
Electronic Message Center (Freestanding)50% of allowed sign area per signOnly 1 per premisesAttached to existing freestanding signUnlockSec. 78-99(5), (g)(i)
Electronic Message Center (Wall Sign)Up to 50% of allowable wall sign area (see wall sign limits)Only 1 per premisesAttached as a wall signUnlockSec. 78-99(5), (g)(ii)

PermitPal covers all 6 zoning districts in Nacogdoches — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Nacogdoches — start free

Prohibited Signs in Nacogdoches

  • Political signs may not have an effective area greater than 36 square feet.
  • Political signs may not be more than eight feet high.
  • Political signs may not be illuminated.
  • Political signs may not have any moving elements.
  • No feather sign may be located on the public right-of-way.
  • Banner signs must be mounted on a building face; cannot be placed elsewhere.
  • All banners must be placed at least 12 feet from the back of the curb, or property line, whichever is greater.
  • No temporary changeable advertisements may be attached to public utility poles or public street lights.
  • Balloon or inflatable signs may not be tethered or anchored in or on public right-of-way.
  • Balloon or inflatable signs may not be tethered or anchored so they may blow into or onto a public right-of-way.
  • Balloon or inflatable signs may not be placed closer than 12 feet from the back of curb or property line, whichever is greater.
  • Balloon or inflatable signs may not be placed on public property without written consent from the governing agency.
  • Balloon or inflatable signs may not be located so that they interfere with or remove the use of required parking of an occupancy.
  • No devices (pennants/festoons) may be strung from poles located on the public right-of-way.
  • No pennant or festoon device may be nearer to the ground than 14 feet.
  • No pennant or festoon device may be attached to any temporary pole or structure.
  • Pole banners may not be placed on utility poles or street light poles; only on privately owned poles.
  • Electronic message center signs may not exceed specified brightness levels (5000 nits day, 1000 nits night).
  • No electronic message center may be added to a nonconforming freestanding sign.
  • Only one electronic message center is allowed per premises.

Exempt Signs in Nacogdoches

  • All signs not requiring permits, as referenced in section 78-77.
  • Political signs placed on private property with the property owner's permission, within specified size and design limits.
  • One construction sign per street frontage per construction project, under specific size and timing conditions.
  • One nonilluminated real estate sign per street frontage per lot or premise, subject to size limitations and with exceptions for properties over two acres.

Sign Plan & Submission Notes for Nacogdoches

  • Signs allowed in planned development districts shall be approved in accordance with section 118-392 of this Code, which may require a sign plan.

Source: municode municipal code