Sign Regulations in Ivins, Utah

Ivins, Utah has specific sign regulations covering 17 sign types across 4 zoning districts. Regulated sign types include Temporary Sign (Class I Use), Freestanding Monument Sign, Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 19, 2025

Sign Regulation Overview for Ivins, Utah

Sample Sign Requirements in Ivins

Sign TypeMax HeightMax AreaSetback
Freestanding Monument Sign7 feet40 square feetMinimum 10 feet from road or street right of way.
Wall SignNo higher than the eave line or top of the parapet wall, or 20 feet, whichever is lower.Up to 100 square feet per building facade
Window SignNo higher than the maximum window height and must be contained within window area20% of window area

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for IvinsFull Coverage

Sign Types Covered

17

  • Temporary Sign (Class I Use)
  • Freestanding Monument Sign
  • Wall Sign
  • Window Sign
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

In Ivins, wall signs can be up to No higher than the eave line or top of the parapet wall, or 20 feet, whichever is lower. and monument signs are limited to 7 feet. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Ivins, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Ivins, regulated sign types include Temporary Sign (Class I Use), Freestanding Monument Sign, Wall Sign, Window Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Ivins, monument signs typically require a Minimum 10 feet from road or street right of way. setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Ivins are regulated with specific requirements for brightness, animation, and message duration. Ivins has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Ivins Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Ivins, Utah sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Ivins, Utah Sign Rules at a Glance

Ivins, Utah regulates 17 sign types across 4 zoning districts. Freestanding Monument Signs in the Neighborhood commercial (CN), Community commercial (C-1), Resort commercial (RC), Resort mixed use (RMU), Commercial professional and research (CPR), Commercial with light manufacturing (CLM) zoning district are capped at 7 feet tall and 40 square feet, with a Minimum 10 feet from road or street right of way. setback (Sec. 16.21.116 Table 21-1 and associated notes). Most commercial signs in Ivins require a permit.

Detailed Sign Ordinance Requirements for Ivins, Utah

Sign Rules by Zoning District in Ivins (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Neighborhood commercial (CN), Community commercial (C-1), Resort commercial (RC), Resort mixed use (RMU), Commercial professional and research (CPR), Commercial with light manufacturing (CLM)7No higher than the eave line or top of the parapet wall, or 20 feet, whichever is lower.Up to 100 square feet per building facade
Residential zoning districts, Commercial zoning districts, Industrial zoning districts14 feet20 square feet
General Regulations For All Zones1010 feet from natural grade or 11 feet from back of curb, whichever is lower48 square feet
1 more zone in PermitPal — start free

Zone-by-Zone Sign Requirements in Ivins(sample of 3 of 4 zones)

Neighborhood commercial (CN), Community commercial (C-1), Resort commercial (RC), Resort mixed use (RMU), Commercial professional and research (CPR), Commercial with light manufacturing (CLM)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Monument Sign7 feet40 square feetMinimum 10 feet from road or street right of way.Must meet chapter and table location requirements. May be located in required front yard setback, but must be at least 10 feet from road or street right of way.Unlock16.21.116 Table 21-1 and associated notes
Wall SignNo higher than the eave line or top of the parapet wall, or 20 feet, whichever is lower.Up to 100 square feet per building facadeOn building facades facing a public road or street.Unlock16.21.116 Table 21-1
Window SignNo higher than the maximum window height and must be contained within window area20% of window areaOn windows of the building.Unlock16.21.116 Table 21-1
Projecting SignNo higher than the eave line/top of the parapet wall, or 15 feet, whichever is lower.On building façadeUnlock16.21.116 Table 21-1
Awning SignNo higher than eave line or top of parapet wall or 15 ft, whichever lower; max sign height is top of awning.20% of awning area (included in wall sign max)Face of awning on building.Unlock16.21.116 Table 21-1
Canopy SignNo higher than eave line or top of canopy or 15 feet, whichever is lower; max sign height is top of canopy.20% of canopy area (included in wall sign max)Face of canopy on building.Unlock16.21.116 Table 21-1
Temporary Sign (Class I Use)4 feet20 square feetAs approved by zoning administrator or sensitive lands committee.Unlock16.21.116 Table 21-1

Residential zoning districts, Commercial zoning districts, Industrial zoning districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Temporary Sign (Class I Use)4 feet20 square feetAs approved by zoning administrator or sensitive lands committee.Unlock16.21.116 Table 21-1

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Address Numbers (Exempt)12 inches highOn property/building to display street address.Unlock16.21.118 Table 21-2
Directional Signs (Exempt)3 feet4 square feet2 per driveway entranceAt driveway entrances; not in a clear view area.Unlock16.21.118 Table 21-2
Hours of Operation (Exempt)1 square foot1 per entranceAt entrance.Unlock16.21.118 Table 21-2
Minor Window Signs (Exempt)4 square feet1 per window; 2 per businessInside window.Unlock16.21.118 Table 21-2
Political Signs (Exempt)4 feet12 square feetNot within clear view area.Unlock16.21.118 Table 21-2
Project Identification Signs (Exempt)10 feet from natural grade or 11 feet from back of curb, whichever is lower48 square feet1 per entranceAt project entranceUnlock16.21.118 Table 21-2
Real Estate Signs (Exempt)3 feet6 square feet (2 x 3 ft)3 feet1 per sales property; 2 off-site signs with permitOn property for sale, lease or rent, or adjacent; off-site signs can be on public property except sidewalks, bike paths, or roadways.Unlock16.21.118 Table 21-2
Subdivision Identification Signs (Exempt)2 per entranceAt primary subdivision entrance.Unlock16.21.118 Table 21-2

PermitPal covers all 4 zoning districts in Ivins — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 4 zones for Ivins — start free

Prohibited Signs in Ivins

  • All off premises signs designed or intended to direct attention to a business, product or service not provided, sold, offered or existing on the property where the sign is located, including all billboards.
  • Signs on any city owned property, except for political signs (must be removed within two days after the voting date) and Parade Of Homes signs (must be removed the day following the last day of the Parade Of Homes).
  • All signs installed, erected, constructed or modified without receiving the necessary application approval.
  • Signs placed on private property without the approval of the owner.
  • Flag mounted signs.
  • All signs having intermittent or flashing illumination, animated or moving parts, rotating or simulating movement by any means of fluttering, spinning or reflection devices or that emit sound.
  • Electronic message signs that change copy electronically, including time, date and temperature signs.
  • All banners, pennants, streamers, balloons, flags, searchlights, strobe lights, beacons and inflatable signs, objects and characters.
  • Flashing signs or lights that contain an intermittent, pulsating or flashing light source.
  • Portable signs that can be moved from place to place and not permanently affixed to the ground or building.
  • All signs that project an image or message onto a wall or other surface.
  • Any text or shape that obstructs the view of motor vehicle operators, bicyclists and pedestrians entering a public roadway from any parking area, service drive, private driveway, alley or other thoroughfare.
  • All signs that obstruct free ingress to or egress from required door, window, fire escape or other required exit.
  • Signs attached to any fences, utility poles, trees, shrubs, rocks or other natural objects, unless specifically included in the design.
  • All signs constituting a hazard to public health, welfare or safety.
  • All neon signs, except a sign stating 'Open' and which do not exceed two square feet.
  • All roof mounted signs.
  • All signs painted on or attached to vehicles that are parked on the public right of way or on private premises for advertising.
  • All signs providing a lighting source that is exposed or directly visible for any public right of way or adjacent property.
  • All neon, rope lights, string lights, exposed bulbs or tubes, or other directly visible light source designed specifically to outline any building roofline or building wall.
  • Any sign, statement, symbol or picture of an obscene nature.

Exempt Signs in Ivins

  • Street address numbers no higher than 12 inches.
  • Posters and fliers announcing or promoting community events provided such posters or fliers do not advertise products or services not associated with the community event (requires technical review committee approval).
  • Directional signs such as 'Enter' and 'Exit' with limits (maximum two per driveway, maximum four square feet and three feet high).
  • Any flag, pennant or insignia of any nation, state, county, city, civic, religious organization, or educational institution.
  • Plaques erected for the purposes of identifying a historic site, building, or structure.
  • One unlighted 'hours of operation' sign per entrance not larger than one square foot in area.
  • Signs containing no advertising (maximum one square foot each, up to four square feet per business).
  • Minor window signs displaying product names, business names, etc., with specific size and quantity limits (no more than four square feet each, no more than two per business, not allowed in agricultural or residential zones).
  • Official government notices and notices posted by government officers or employees in performance of their duties.
  • Political signs for support of candidates or ballot measures, provided they are stationary, unlighted, limited in display period and size, and not placed in clear view areas.
  • Project identification signs meeting specified size and time limits, and one helium balloon during certain events.
  • Signs required for safety or instructional purposes by the city, such as 'No Parking' and street name signs.
  • Real estate signs advertising property for sale, lease, or rent, with location, size, and display restrictions.
  • Any religious symbol attached to a place of religious worship.
  • One residential nameplate sign showing the occupant's name and address, not exceeding two square feet and not containing advertising copy.
  • Restaurant menu boxes up to four square feet (larger boxes require permit and count toward sign area limits).
  • Temporary decorations or displays clearly incidental to, and customarily associated with, any holiday or celebration.
  • Signs required or specifically authorized for a public purpose by any law, statute, or ordinance (including traffic control signs).
  • Art, monuments, sculpture, fountains, and similar site or building features not containing advertising or logos.
  • No more than two permanent subdivision identification signs per primary entrance, approved at time of subdivision approval.
  • Temporary or permanent signs erected to warn of danger or hazardous conditions by government agencies, utility or construction companies.
  • Signs displayed on motor vehicles or trailers being operated in the normal course of business, if main purpose is not for display of signs.

Sign Plan & Submission Notes for Ivins

  • A site plan is required with all sign applications (Class I: three copies; Class II/III: eight full + twenty reduced copies; Class IV/V: fourteen full + twenty reduced copies), identifying property layout, existing and proposed signs, dimensions, colors, and materials.
  • Additional maps, drawings, plans, illustrations or materials may be required by the zoning administrator or applicable authority for adequate description of the proposed sign.
  • An accurate lighting plan and calculations of sign area may be required with all but Class I applications; may also be required if determined necessary.
  • A building permit may also be required for sign installation depending on building code requirements.
  • Approval authorities (zoning administrator, sensitive lands committee, commission, city council) review sign plans as part of the use application process.
  • Signs for which a building permit is required shall comply with the adopted building code, including necessary footings and structural/electrical permits, and are subject to inspection.
  • Subdivision identification signs must be approved at time of final subdivision approval by the land use authority.