Questions? Call us at (262) 218-2915

Sign Regulations in Burien, Washington

Burien, Washington has specific sign regulations covering 53 sign types across 9 zoning districts. Regulated sign types include Wall Sign (Primary Building Facade), Wall Sign (Secondary Building Facade), Awning or Canopy Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: October 9, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Burien, Washington

Sample Sign Requirements in Burien

Sign TypeMax HeightMax AreaSetback
Bus Shelter SignNot listedNo maximumNot listed
Public Agency SignNot listedNo maximumNot listed
Public Service Information SignNot listedNo maximumNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for BurienFull Coverage

Sign Types Covered

53

  • Wall Sign (Primary Building Facade)
  • Wall Sign (Secondary Building Facade)
  • Awning or Canopy Sign
  • Blade Sign
  • +2 more types

Zoning Districts

9

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Burien

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Burien, the height limit for Freestanding Sign (MU-1/MU-1 BP/I) in the Mixed-Use Low (MU-1); Mixed-Use Low Boulevard Park (MU-1 BP); Industrial (I) zoning districts is 8 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Burien require a permit. From the submission notes on this page: Master Sign Plan option: The Director may allow deviations from the chapter if a Master Sign Plan demonstrates exceptional visual harmony and meets all approval criteria; the application is decided by the Director and may be appealed as a Type 1 land use review (19.30.130.1–2). Run a code check for an exact address to see the permit requirements for that zone.

Burien's sign code covers 53 sign types, including Wall Sign (Primary Building Facade), Wall Sign (Secondary Building Facade), Awning or Canopy Sign, and Blade Sign. Most commercial signs need a permit. The ordinance lists 10 exemptions. One of them: A sign permit is not required for repainting, cleaning, or other normal maintenance and repair of a permitted sign, or for sign face and copy changes that do not alter the size or structure of the sign (19.30.100.1; 19.30.120.1). The full list is on this page.

In Burien, Blade Sign in the Mixed-Use High (MU-2) and other zoning districts must be set back at least 2 ft from curb. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Burien's sign ordinance that cover digital, changing, or flashing signs: Blinking and/or flashing lights are prohibited, except for the time and temperature portion of an otherwise permitted sign as allowed in Table 19.30-1 (19.30.040.2.B); additionally, any continuous or sequential blinking or flashing operation is prohibited (19.30.070.3.C). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Burien Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Burien, Washington, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Burien, Washington Sign Rules at a Glance

Burien, Washington regulates 53 sign types across 9 zoning districts. Blade Signs in the Mixed-Use High (MU-2) and other zoning districts are capped at 12 ft tall and 4 sq ft per side, set back at least 2 ft from curb. Most commercial signs in Burien require a permit.

Detailed Sign Ordinance Requirements for Burien, Washington

Sign Rules by Zoning District in Burien (9 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones7Not listed25 sq ft per flagNot listed
Residential, Single-Family (RS); Residential 1 (R-1); Residential 2 (R-2); Residential 3 (R-3); Residential 4 (R-4); Residential 5 (R-5)176 ft25 sq ftNot listed
Mixed-Use High (MU-2); Mixed-Use High Employment (MU-2 E); Mixed-Use High Creative District (MU-2 CD); Downtown Mixed-Use (MU-DT); Community Mixed-Use (MU-C)19Maximum 20 ft above finished grade32 sq ft per signNot listed
Mixed-Use Low (MU-1); Mixed-Use Low Boulevard Park (MU-1 BP); Industrial (I)18Maximum 20 ft above finished gradeType I: up to 672 sq ft face; Type II: up to 300 sq ft faceNot listed
Airport Industrial (AI); Arterial Mixed-Use (MU-A)18Maximum 20 ft above finished gradeType I: up to 672 sq ft face; Type II: up to 300 sq ft faceNot listed
Special Planning Area 2 (SPA-2)1Not listedNot listedNot listed
CR; CC-25Per Table 19.30-1 standards for each sign typePer Table 19.30-1 standards for each sign typeNot listed
Mixed-Use Low Boulevard Park (MU-1 BP)1Not listedNot listedNot listed
Community Mixed-Use (MU-C) - Clarification Note1Code includes conflicting maxima: 5 ft (BMC 19.30.060.5.B.i) AND 8 ft (BMC 19.30.060.5.B.ii); consult DirectorCode includes conflicting caps: 32 sq ft (BMC 19.30.060.5.A.i) AND 48 sq ft (BMC 19.30.060.5.A.ii); consult DirectorNot listed

Zone-by-Zone Sign Requirements in Burien(sample of 3 of 9 zones)

Mixed-Use High (MU-2); Mixed-Use High Employment (MU-2 E); Mixed-Use High Creative District (MU-2 CD); Downtown Mixed-Use (MU-DT); Community Mixed-Use (MU-C)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Primary Building Facade)Not listedPer formulaNot listedNot listedNo maximum (subject to total sign area limits)On tenant’s primary building facadeNot listedUnlockBMC 19.30.060.4.A, D, E, F, G; BMC 19.30.070.6; Table 19.30-1 (Wall sign)
Wall Sign (Secondary Building Facade)Not listedPer formulaNot listedNot listedNo maximum (subject to total sign area limits)On tenant’s secondary building facade(s)Not listedUnlockBMC 19.30.060.4.B; Table 19.30-1 (Wall sign)
Awning or Canopy SignNot listedIncluded in total sign area allowedNot listedNot listedOne per business per facadeOn-site or over public street rights-of-wayNot listedUnlockTable 19.30-1 (Awning or canopy sign)
Blade Sign12 ft4 sq ft per sideNot listed2 ft minimum from curbOne per business per street frontageOn-site; may extend over public street right-of-wayNot listedUnlockTable 19.30-1 (Blade sign)
Window SignMaximum 20 ft above finished gradeNot specifically capped (subject to 25% inclusion rule)Not listedNot listedNo maximumOn-site (on or in windows)Not listedUnlockTable 19.30-1 (Window sign)
Freestanding Sign (MU-DT/MU-2/MU-2 E/MU-2 CD/MU-C)5 ft32 sq ft per signNot listedNo minimum setback required (general 5 ft setback does not apply in these zones)One per site per street frontage; an additional monument sign allowed on a street frontage of ≥400 ft (max 32 sq ft and 5 ft height)On-site; oriented to a street with usable motor vehicle access to customer parkingNot listedUnlockBMC 19.30.060.5.A.i, 5.B.i, 5.C, 5.E(i–iv), 5.F–K
Multi-Tenant Complex Identification SignPer freestanding sign height limits in the zone32 sq ft (for complex identification)Not listedPer zone’s freestanding sign setback rulesOne additional identification sign allowance per qualifying complexDisplayed on a building within the complex, combined as part of other signage, or on an additional monument sign along the street frontage providing direct vehicular accessNot listedUnlockBMC 19.30.060.5.D
Property For Sale/Lease/Rent (Nonresidential Property)10 ft32 sq ft per sign face (16 sq ft per sign face if face is visible from more than one direction)Not listedNot listedOne per street frontageOne sign per street frontageNot listedUnlockBMC 19.30.060.6.1–5

Mixed-Use Low (MU-1); Mixed-Use Low Boulevard Park (MU-1 BP); Industrial (I)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Primary Building Facade)Not listedPer formulaNot listedNot listedNo maximum (subject to total sign area limits)On tenant’s primary building facadeNot listedUnlockBMC 19.30.060.4.A, F, G; BMC 19.30.070.6; Table 19.30-1 (Wall sign)
Wall Sign (Secondary Building Facade)Not listedPer formulaNot listedNot listedNo maximum (subject to total sign area limits)On tenant’s secondary building facade(s)Not listedUnlockBMC 19.30.060.4.B; Table 19.30-1 (Wall sign)
Blade Sign12 ft4 sq ft per sideNot listed2 ft minimum from curbOne per business per street frontageOn-site; may extend over public street right-of-wayNot listedUnlockTable 19.30-1 (Blade sign)
Window SignMaximum 20 ft above finished gradeNot specifically capped (subject to 25% inclusion rule)Not listedNot listedNo maximumOn-site (on or in windows)Not listedUnlockTable 19.30-1 (Window sign)
Freestanding Sign (MU-1/MU-1 BP/I)8 ft48 sq ft per signNot listedMinimum setback 5 ftOne per site per street frontage; an additional monument sign allowed on a street frontage of ≥400 ft (max 48 sq ft and 8 ft height)On-site; oriented to a street frontageNot listedUnlockBMC 19.30.060.5.A.ii, 5.B.ii, 5.C, 5.F–K
Multi-Tenant Complex Identification SignPer freestanding sign height limits in the zone32 sq ft (for complex identification)Not listedPer zone’s freestanding sign setback rulesOne additional identification sign allowance per qualifying complexDisplayed on a building within the complex, combined as part of other signage, or on an additional monument sign along the street frontage providing direct vehicular accessNot listedUnlockBMC 19.30.060.5.D
Property For Sale/Lease/Rent (Nonresidential Property)10 ft32 sq ft per sign face (16 sq ft per sign face if face is visible from more than one direction)Not listedNot listedOne per street frontageOne sign per street frontageNot listedUnlockBMC 19.30.060.6.1–5
Billboard (Relocated - I zone only)I zone: up to 15 ft above average height of all buildings within 330 ft of billboard or 45 ft, whichever is lessType I: up to 672 sq ft face; Type II: up to 300 sq ft faceType I: up to 48 ft width; Type II: up to 25 ft widthObserve same setbacks as required for primary use of site; Type II ≥100 ft from residential zones; Type I ≥330 ft from residential zonesPer relocation program; no more than two Type I faces or equivalent on a single billboardI zone south of So. 176th St.; setbacks per primary use of site or closest adjacent use if site undeveloped; Type II ≥100 ft from any residential zone; Type I ≥330 ft from any residential zoneNot listedUnlockBMC 19.30.090.1–15 (esp. .5.B, .6, .7.B, .9, .10, .11, .12, .13, .14)

Airport Industrial (AI); Arterial Mixed-Use (MU-A)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Primary Building Facade)Not listedPer formulaNot listedNot listedNo maximum (subject to total sign area limits)On tenant’s primary building facadeNot listedUnlockBMC 19.30.060.4.A, F, G; BMC 19.30.070.6; Table 19.30-1 (Wall sign)
Wall Sign (Secondary Building Facade)Not listedPer formulaNot listedNot listedNo maximum (subject to total sign area limits)On tenant’s secondary building facade(s)Not listedUnlockBMC 19.30.060.4.B; Table 19.30-1 (Wall sign)
Blade Sign12 ft4 sq ft per sideNot listed2 ft minimum from curbOne per business per street frontageOn-site; may extend over public street right-of-wayNot listedUnlockTable 19.30-1 (Blade sign)
Window SignMaximum 20 ft above finished gradeNot specifically capped (subject to 25% inclusion rule)Not listedNot listedNo maximumOn-site (on or in windows)Not listedUnlockTable 19.30-1 (Window sign)
Freestanding Sign (AI/MU-A)20 ft plus 1 additional ft for each 25 linear ft (or portion thereof) of street frontage, up to maximum total height of 35 ftUp to 200 sq ft based on street frontageNot listedMinimum setback 5 ftOne per site per street frontage; an additional monument sign allowed on a street frontage of ≥400 ft (max 64 sq ft and 12 ft height)On-site; oriented to street frontageNot listedUnlockBMC 19.30.060.5.A.iii, 5.B.iii, 5.C, 5.F–K
Multi-Tenant Complex Identification SignPer freestanding sign height limits in the zone32 sq ft (for complex identification)Not listedPer zone’s freestanding sign setback rulesOne additional identification sign allowance per qualifying complexDisplayed on a building within the complex, combined as part of other signage, or on an additional monument sign along the street frontage providing direct vehicular accessNot listedUnlockBMC 19.30.060.5.D
Property For Sale/Lease/Rent (Nonresidential Property)10 ft32 sq ft per sign face (16 sq ft per sign face if face is visible from more than one direction)Not listedNot listedOne per street frontageOne sign per street frontageNot listedUnlockBMC 19.30.060.6.1–5
Billboard (Relocated - MU-A zone only)MU-A: up to 15 ft above average height of all buildings within 330 ft of billboard or 35 ft, whichever is less; If oriented to SR-518 and in specified non-residential area near SR-518, see special case belowType I: up to 672 sq ft face; Type II: up to 300 sq ft faceType I: up to 48 ft width; Type II: up to 25 ft widthObserve same setbacks as required for primary use of site; Type II ≥100 ft from residential zones; Type I ≥330 ft from residential zonesPer relocation program; no more than two Type I faces or equivalent on a single billboardMU-A zone north of 146th St. and south of 154th St.; setbacks per primary use of site or closest adjacent use if site undeveloped; Type II ≥100 ft from any residential zone; Type I ≥330 ft from any residential zoneNot listedUnlockBMC 19.30.090.5.A, .6, .7.A and .7.C, .9, .10, .12–.14

PermitPal covers all 9 zoning districts in Burien. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Burien

  • Any sign not specifically permitted by Chapter 19.30 is prohibited (19.30.040.2.A).
  • Blinking and/or flashing lights are prohibited, except for the time and temperature portion of an otherwise permitted sign as allowed in Table 19.30-1 (19.30.040.2.B); additionally, any continuous or sequential blinking or flashing operation is prohibited (19.30.070.3.C).
  • Illumination exceeding the specified light intensity thresholds is prohibited: more than 1/2 statutory daylight measured directly from any distance greater than 3 feet (neon exempt), or more than 1/16 statutory daylight (1/32 for undiffused neon) measured with a 1-degree spot meter at 20 feet from the light source or the closest property line (19.30.070.3.A–B).
  • Undiffused light sources are prohibited for sign illumination (other than neon as permitted) (19.30.070.3.D).
  • Signs affixed to natural features, such as trees, rocks, and other natural features, are prohibited (19.30.040.2.C).
  • New signs erected upon, against, or directly above a roof or that project above the highest point of the roof line, parapet, or fascia, including signs affixed to rooftop equipment structures, are prohibited (19.30.040.2.D).
  • Signs affixed to or painted on utility poles, street sign poles, traffic signal equipment and poles, garbage receptacles (except signs placed by the waste company), bridges, railings, fences, and other street furniture/fixtures are prohibited; governmental traffic/utility signs are permitted (19.30.040.2.E).
  • Off-site signs are prohibited, except as specifically permitted by the chapter (19.30.040.2.F).
  • Signs in the public right-of-way are prohibited, except as specifically permitted by the chapter or applicable law (19.30.040.2.G).
  • Revolving or rotating signs are prohibited, with limited exceptions for barber poles, numerical parts of clocks or thermometers, tri-vision billboard faces, or where specifically permitted by the chapter (19.30.040.2.H).
  • Signs posted or displayed upon a movable chassis or support with or without wheels are prohibited (19.30.040.2.I).
  • Signs mounted on parked vehicles and visible from the public right-of-way are prohibited, unless the vehicle is primarily used for normal day-to-day transportation (not primarily for advertising) or the sign advertises the vehicle for sale (19.30.040.2.J).
  • Graffiti is prohibited (19.30.040.2.K; BMC Chapter 8.55).
  • Signs that create a traffic hazard or public nuisance are prohibited, including: imitating official traffic signs/signals or using words such as stop, look, danger, caution, warning, or go slow; signs that may confuse motorists or detract from legal traffic devices; any sign placed to obscure motorists’ vision (19.30.040.2.L).
  • Wind signs or devices that flutter, wave, sparkle, or otherwise move from wind pressure are prohibited, except as specifically permitted (19.30.040.2.M; see allowances for carnival-like devices).
  • Exterior wall signs may not cover or interfere with architectural building details, windows, doors, fire escapes, stairways, or other openings intended to provide light, air, ingress, or egress (19.30.070.6).
  • All signs (except public service traffic-safety signs) must comply with sight distance requirements; signs violating sight distance are not allowed (19.30.070.1).
  • Prohibited signs are not subject to a variance or a Master Sign Plan (19.30.040.2).

Exempt Signs in Burien

  • The chapter does not apply to Public Agency signs, Public Service information signs, and Traffic signs (19.30.040.1.A).
  • Point-of-purchase advertising displays such as product dispensers are exempt from the chapter (19.30.040.1.B).
  • Gravestones are exempt from the chapter (19.30.040.1.C).
  • Historical site plaques and memorial signs not exceeding 2 square feet per sign face are exempt from the chapter (19.30.040.1.D).
  • Structures or improvements intended for a separate use (e.g., phone booths, donation containers, newspaper recycling boxes) are exempt from the chapter (19.30.040.1.E).
  • Building addresses with numbers and letters not more than 12 inches in height are exempt from the chapter (19.30.040.1.F).
  • Exterior signs or displays not visible from streets or ways open to the public are exempt from the chapter (19.30.040.1.G).
  • Artwork, including murals that meet the definition (noncommercial), is exempt from the chapter (19.30.040.1.H).
  • A sign permit is not required for repainting, cleaning, or other normal maintenance and repair of a permitted sign, or for sign face and copy changes that do not alter the size or structure of the sign (19.30.100.1; 19.30.120.1).
  • Lawfully placed temporary signs do not require a sign permit unless otherwise noted (19.30.100.1; 19.30.120.3).

Sign Plan & Submission Notes for Burien

  • A Master Sign Plan is required when a building facade is more than two stories high and more than one wall sign is proposed on any facade (19.30.060.4.E; Table 19.30-1, Wall sign row).
  • Master Sign Plan option: The Director may allow deviations from the chapter if a Master Sign Plan demonstrates exceptional visual harmony and meets all approval criteria; the application is decided by the Director and may be appealed as a Type 1 land use review (19.30.130.1–2).
  • Master Sign Plan submittals must include the usual sign permit items plus: a narrative addressing the approval criteria, a written description of the design theme, and at least five color renderings/simulations of proposed signs in context (19.30.130.3).
  • Master Sign Plan approval criteria include: consistent design theme; deviations are the minimum necessary for readable identification from the accessing rights-of-way; compatibility with planned land use and surrounding aesthetics; compatibility with adjacent neighborhood/business district; does not obstruct natural scenic views; and compliance with relevant City-adopted design documents where applicable (19.30.130.4).
  • Minor modifications to an approved Master Sign Plan may be approved by the Director if they do not increase maximum sign area, maintain visual harmony with integral design elements, and comply with applicable City design documents (19.30.130.5).
  • Prohibited signs cannot be approved or legalized via a Master Sign Plan or by variance (19.30.040.2).
  • SPA-2 zone: Signs in SPA-2 are reviewed and approved as part of a City-approved Master Plan for the zone under BMC 19.15.060 (19.30.060.1).
  • The first sign permit application on a site must include a complete listing and mapping of all existing signs on the site (type, area, height, and location), to be updated with subsequent applications (19.30.110.2).

Source: other municipal code