Sign Regulations in Centralia, Washington

Centralia, Washington has specific sign regulations covering 32 sign types across 14 zoning districts. Regulated sign types include All signs allowed under 'All other zoning districts (C-1, C-2, C-3, LBD, M-1, M-2)', Temporary Building Sign, Signs are regulated by the provisions for the applicable district and by general regulations for all zones.. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: June 19, 2025

Sign Regulation Overview for Centralia, Washington

Sample Sign Requirements in Centralia

Sign TypeMax HeightMax AreaSetback
Real Estate Sign (Temporary, Nonilluminated)3 sq ft per sign face
Open House Sign (attached to Real Estate Sign)1.5 sq ft
Open House Sign (standalone, if no real estate sign installed)6 sq ft

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for CentraliaFull Coverage

Sign Types Covered

32

  • All signs allowed under 'All other zoning districts (C-1, C-2, C-3, LBD, M-1, M-2)'
  • Temporary Building Sign
  • Signs are regulated by the provisions for the applicable district and by general regulations for all zones.
  • Real Estate Sign (Temporary, Nonilluminated)
  • +2 more types

Zoning Districts

14

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Centralia

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

Sign height limits in Centralia vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Centralia, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Centralia, regulated sign types include All signs allowed under 'All other zoning districts (C-1, C-2, C-3, LBD, M-1, M-2)', Temporary Building Sign, Signs are regulated by the provisions for the applicable district and by general regulations for all zones., Real Estate Sign (Temporary, Nonilluminated), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Centralia vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Centralia are regulated with specific requirements for brightness, animation, and message duration. Centralia has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Centralia Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Centralia, Washington sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Centralia, Washington Sign Rules at a Glance

Centralia, Washington regulates 32 sign types across 14 zoning districts. Freestanding Sign (Single-Tenant Building)s in the All other zoning districts (C-1, C-2, C-3, LBD, M-1, M-2) zoning district are capped at 30 ft tall and 150 sq ft, with a Min 2 ft from right-of-way (per 18.24.210) setback (Sec. 18.24.330(F)(1)). Most commercial signs in Centralia require a permit.

Detailed Sign Ordinance Requirements for Centralia, Washington

Sign Rules by Zoning District in Centralia (14 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Single-family and two-family residential districts (R:2, R:4, R:8), Very Low-Density Residential District (R:2), Low-Density Residential District (R:4), Moderate-Density Residential District (R:8)750 sq ft
Multifamily and transitional use districts (R:15, R:20), Medium-High-Density Residential District (R:15), High-Density Residential District (R:20)325 sq ft
All other zoning districts (C-1, C-2, C-3, LBD, M-1, M-2)1530 ft360 sq ft per business (minimum 60 sq ft allowed if business has only a wall sign)
Limited Business District (LBD)1
General Commercial District (C-1)1
Highway Commercial District (C-2)1
Core Commercial District (C-3)1
Light Industrial District (M-1)1
Industrial District (M-2)1
Gateway Commercial District (GC)1
Health Services District (H-1)1
Open Space/Public Facilities District (OS/PF)1
Port Master Plan District (PMP)1
General Regulations For All Zones616 in x 74 in per organization, or 24 sq ft aggregate if multiple on one sign

Zone-by-Zone Sign Requirements in Centralia(sample of 3 of 14 zones)

Single-family and two-family residential districts (R:2, R:4, R:8), Very Low-Density Residential District (R:2), Low-Density Residential District (R:4), Moderate-Density Residential District (R:8)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Real Estate Sign (Temporary, Nonilluminated)3 sq ft per sign face1 per street frontageOn premisesUnlock18.24.310(A)
Open House Sign (attached to Real Estate Sign)1.5 sq ft1Attached to existing real estate signUnlock18.24.310(B)
Open House Sign (standalone, if no real estate sign installed)6 sq ft1On premisesUnlock18.24.310(B)
Nameplate Sign2 sq ft1Situated on the premisesUnlock18.24.310(C)
Temporary Building Sign25 sq ft1On premises undergoing constructionUnlock18.24.310(D)
Permanent Development Sign50 sq ft1 per main entranceAt main entrance(s)Unlock18.24.310(E)
Nonresidential Use Sign (e.g., churches, schools, clinics)25 sq ft1 per useOn premisesUnlock18.24.310(F)

All other zoning districts (C-1, C-2, C-3, LBD, M-1, M-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign (Single-Tenant Building)30 ft150 sq ftMin 2 ft from right-of-way (per 18.24.210)1 per single-tenant building; see below for multitenant & additionalOn premises (not over right-of-way)Unlock18.24.330(F)(1)
Freestanding Sign (Multitenant Building)30 ft250 sq ft sign; 25 sq ft directory sign per tenant, max 100 sq ft total per buildingMin 2 ft from right-of-way (per 18.24.210)1 per multitenant buildingOn premisesUnlock18.24.330(F)(2)
Freestanding Sign (Multifamily Complex)30 ft250 sq ft sign; directory signage as aboveMin 2 ft from right-of-way (per 18.24.210)1 per complexOn premisesUnlock18.24.330(F)(3)
Freestanding Sign (Additional for Street Frontage)30 ft150 sq ft per signMin 2 ft from right-of-way (per 18.24.210)1 per 300 ft over first 300 ftOn premisesUnlock18.24.330(F)(4)
Projecting Sign (in lieu of Freestanding)As above1 per businessOn buildingUnlock18.24.330(F)(6)
Wall Sign360 sq ft per business (minimum 60 sq ft allowed if business has only a wall sign)Per businessOn wall/awning/marqueeUnlock18.24.330(G)
Under-Marquee Sign6 sq ft per sign face1 per business entranceHanging under marquee/canopy/permanent walkway cover, in front of business, adjacent to entranceUnlock18.24.330(E)
Parking Lot Signs20 sq ft per sign, 1 per entrance1 per entranceAt each parking lot entranceUnlock18.24.330(J)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Portable Sign (Sandwich Board/A-Board)6-8 sq ft per face, 2 faces only1On-premises; not on public right of way except as provided in 5.30 CMCUnlock18.24.200
Directional Sign (Govt/Institutional/Civic/Religious Parking/Exits/Entrances)6 sq ftOn premises, as neededUnlock18.24.020, 230, 250
Civic and Church Directional/Entrance Sign16 in x 74 in per organization, or 24 sq ft aggregate if multiple on one signMinimum 25 feet from streetAt/near city limits, on rights-of-way or private property (with permission)Unlock18.24.230
Political Sign1 per candidate per lotPrivate property onlyUnlock18.24.240
Essential Public Needs Sign6 sq ftOn premisesUnlock18.24.250
Incidental Sign (General; product info, hours, etc.)8 sq ftOn premisesUnlock18.24.020, 18.24.040(F)

PermitPal covers all 14 zoning districts in Centralia — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 14 zones for Centralia — start free

Prohibited Signs in Centralia

  • No person shall erect, re-erect, construct, apply or structurally alter or move any sign without first obtaining a building permit, except as otherwise provided.
  • It is unlawful for any person to erect or place within the city: swinging projecting signs; outdoor advertising signs (billboards); flashing signs (except certain electronic signs), signs which revolve in excess of five revolutions per minute, and signs which contain wind-actuated elements; signs attached to or placed on a vehicle or trailer parked on private or public property for advertising (except certain exemptions); benches on sidewalks or private property bearing advertising matter (other than as excepted or as authorized as a conditional use); private signs placed in or on a public thoroughfare (except certain required directional signs or other exceptions); any sign which constitutes a traffic hazard or detriment to safety by size, location, movement, content, coloring, method of illumination, or by obstructing vision or official traffic signals; signs not properly maintained, showing neglect, or in a dilapidated or hazardous condition; abandoned signs; signs in residential districts for home occupations.
  • Off-premises signs are generally prohibited except by approved variance.
  • No sign may use the words “stop,” “look,” “danger,” “drive-in,” or any other words, symbol, or character that would interfere with, mislead, or confuse traffic.
  • No flashing or revolving red, green, blue, or amber lights shall be permitted on any sign.
  • No sign may be erected so that it obstructs vision of pedestrians.
  • Signs not properly maintained, showing neglect, or in hazardous condition must be repaired or removed.
  • No person shall construct, establish, or maintain any exterior or interior stationary lighting or illumination system intended to be viewed from a public right-of-way, which contains or utilizes: (1) any exposed incandescent lamp with a wattage in excess of twenty-five watts unless a dimmer or sunscreen is attached; (2) any exposed incandescent lamp with an internal metallic or external reflector; (3) any revolving beacon light; (4) any continuous or sequential flashing operation in which more than one-third of the lights are off at any one time and/or uses light over twenty-five watts.
  • No sign, except as authorized, may be placed in or over a public right-of-way.
  • Any sign which by glare or method of illumination constitutes a hazard to traffic is prohibited.
  • Political signs cannot be placed on public property or right-of-way, or on private/vacant property without owner permission.
  • Outdoor advertising signs (billboards) are prohibited.
  • No sign shall be erected that projects more than allowed distances from property lines, over roof/parapet, or is less than vertical clearance requirements.
  • Home occupation signs are prohibited in residential districts.
  • Signs displaying upon the windows of vacant stores, except as specifically allowed, are prohibited.

Exempt Signs in Centralia

  • Official directional and traffic signs, copy of signs, signs not intended to be viewed from a public right-of-way, window displays, point of purchase advertising displays such as product dispensers, national flags, flags of political subdivisions, symbolic flags of an institution or business, gravestones, barber poles, historical site plaques, signs in R:2 and R:4 zones of six square feet or less giving the street number, and other signs of a noncommercial nature are not regulated by the sign code.
  • No permit is required for: changing advertising copy or message on lawful electric or painted sign, theater marquee or similar changeable copy signs; painting, repainting, cleaning, repair and normal maintenance unless structural/electric changes are made; real estate signs six square feet or less; political signs; temporary holiday signs and decorations customary for special holidays on private property; incidental signs of eight square feet or less; temporary paper signs in windows not exceeding fifty percent of window area; religious symbols; temporary building signs (2 per project) denoting architect, engineer, contractor or developer, sized not exceeding 32 square feet for first sign and 12 for second; memorial signs or tablets, names of buildings, dates of erection; bulletin boards not over 12 square feet for public, charitable or religious institutions located on premises; signs required by law, traffic or pedestrian control signs, signs indicating scenic or historic points of interest, erected by public officer; sculptures, fountains, mosaics, and design features not incorporating advertising or identification; flag of a government or noncommercial institution such as school; official public and court notices; signs painted on or attached inside a window using less than 20 percent of the window; temporary signs 8 square feet or less displayed less than 30 days; essential public needs signs (restrooms, deliveries in rear, etc.) under 6 square feet; signs, banners, or flags of a civic nature or benefit to the community placed on publicly owned appurtenances on rights-of-way with written approval of the city manager, subject to size, design, and other restrictions set by city manager.

Sign Plan & Submission Notes for Centralia

  • A comprehensive design plan (master sign plan) can be submitted for special consideration, potentially allowing height or area in excess of normal zone limits, subject to planning commission approval; applications must include narratives regarding legibility, visibility, site relations, land use characteristics, and include renderings. Approval may require conditions.
  • Supergraphics as part of a comprehensive design plan require final approval through a hearing examiner in accordance with the variance procedure.
  • Applications for comprehensive design plan permits must be submitted to the building official along with a regular sign permit application.
  • Signs not otherwise allowed may be permitted through a variance or special use hearing (e.g., off-premises signs, high rise signs, roof signs exceeding parapet, large temporary signs). These require a hearing examiner/variance process.
  • Site plan review (see Ch. 20.84 CMC) is required for all residential projects with more than one unit and nonresidential uses to ensure compatibility with architectural and neighborhood elements.
  • New buildings or exterior remodels may be subject to design review areas and additional committees, under site plan/design review processes.
  • Any complex development, substantial new development, major remodel, or nonresidential use (including signs as part of building/facility plans) will likely require presentation of architectural, landscape, and sign plans to city or site plan review committees prior to permit issuance.
  • The building official may waive submission of structure plans for signs when structural aspects are of minor importance.
  • Permit exceptions do NOT exempt signs from compliance with sign code provisions and general prohibitions.
  • Certain exceptions for non-permitted signs (per 18.24.040) may still be subject to city or city manager review (e.g., civic banners on public appurtenances, etc.), or additional requirements set administratively.

Source: other municipal code