Sign Regulations in Kennewick, Washington
Kennewick, Washington has specific sign regulations covering 52 sign types across 15 zoning districts. Regulated sign types include Banner, Development/Sale Sign (On-site Residential Property), Directional Sign (Residential Property Off-site – nearest arterial). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 27, 2026
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Kennewick, Washington
Sample Sign Requirements in Kennewick
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Development/Sale Sign (On-site Residential Property) | Up to 8 ft | Up to 8 sq ft | Must comply with view clearance/obstruction standards (KMC 13.12; KMC 18.27.060) |
| Directional Sign (Residential Property Off-site – nearest arterial) | Not listed | Up to 6 sq ft | Must comply with view clearance/obstruction standards (KMC 13.12; KMC 18.27.060) |
| Freestanding Sign (Manufactured Home Park or Multi-family with 5+ units) | Up to 10 ft | Up to 32 sq ft | Must comply with view clearance/obstruction standards (KMC 13.12; KMC 18.27.060) |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
52
- Banner
- Development/Sale Sign (On-site Residential Property)
- Directional Sign (Residential Property Off-site – nearest arterial)
- Freestanding Sign (Manufactured Home Park or Multi-family with 5+ units)
- +2 more types
Zoning Districts
15
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Kennewick
Other Cities in Washington
Frequently Asked Questions
In Kennewick, the height limit for Freestanding Sign - Single Business in the Industrial, Light (IL), Industrial, Heavy (IH) zoning districts is 60 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Kennewick require a permit. From the submission notes on this page: A building permit is required for all signs unless specifically exempted in KMC 18.24.060(2). Permit applications must include owner and user information, site address and location, sign drawings with design and dimensions, structural calculations, and lighting details (KMC 18.24.070). Run a code check for an exact address to see the permit requirements for that zone.
Kennewick's sign code covers 52 sign types, including Banner, Development/Sale Sign (On-site Residential Property), Directional Sign (Residential Property Off-site – nearest arterial), and Freestanding Sign (Manufactured Home Park or Multi-family with 5+ units). Most commercial signs need a permit. The ordinance lists 13 exemptions. One of them: Home occupation signs and signs for family day care homes do not require a building permit. The full list is on this page.
This page doesn't list a single setback distance for signs in Kennewick. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Kennewick's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.
Ready to Research Kennewick Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Kennewick, Washington, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Kennewick, Washington Sign Rules at a Glance
Kennewick, Washington regulates 52 sign types across 15 zoning districts. Projecting Signs (UMU) in the Urban Mixed-Use (UMU) zoning district are capped at 10 ft tall and 24 sq ft per sign face. Most commercial signs in Kennewick require a permit.
Detailed Sign Ordinance Requirements for Kennewick, Washington
Sign Rules by Zoning District in Kennewick (15 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Residential - Suburban (RS) | 7 | Up to 16 ft | Up to 50 sq ft per street-facing building facade | Not listed |
| Residential - Low Density (RL) | 7 | Up to 16 ft | Up to 50 sq ft per street-facing building facade | Not listed |
| Residential - Medium Density (RM) | 7 | Up to 16 ft | Up to 50 sq ft per street-facing building facade | Not listed |
| Residential - High Density (RH) | 7 | Up to 16 ft | Up to 50 sq ft per street-facing building facade | Not listed |
| Residential - Manufactured Home (RMH) | 7 | Up to 16 ft | Up to 50 sq ft per street-facing building facade | Not listed |
| Residential - Trailer Park (RTP) | 7 | Up to 16 ft | Up to 50 sq ft per street-facing building facade | Not listed |
| Public Facilities (PF) | 10 | Up to 60 ft | Up to 150/300/400 sq ft depending on height tier | Not listed |
| Commercial - Neighborhood (CN), Commercial - Office (CO), Commercial - Regional (CR), Commercial - Auto Row (CAR), Commercial - Marina (CM), Business Park (BP), Industrial Park (IP), Historic, Mixed-Use (HMU) | 13 | Up to 60 ft | Up to 150/300/400 sq ft depending on height tier | Not listed |
| Commercial - Community (CC), Commercial - General (CG) | 14 | Up to 60 ft | Up to 150/300/400 sq ft depending on height tier | Not listed |
| Industrial, Light (IL), Industrial, Heavy (IH) | 15 | Up to 60 ft | Up to 150/300/400 sq ft depending on height tier | Not listed |
| Commercial - Central Business District (CBD) | 15 | Preferred monument/ground; if not practical, max height 20 ft | Up to 64 sq ft per sign face | Not listed |
| Urban Mixed-Use (UMU) | 15 | Preferred monument/ground; if not practical, max height 20 ft | Up to 64 sq ft per sign face | Not listed |
| Justice Facilities (JF) | 2 | Maximum 6 ft (measured per KMC 18.24.020(26)) | Maximum area per sign face: 32 sq ft | Not listed |
| Parking (P) | 2 | Maximum 6 ft (measured per KMC 18.24.020(26)) | Maximum area per sign face: 32 sq ft | Not listed |
| Open Space (OS) | 2 | Maximum 6 ft (measured per KMC 18.24.020(26)) | Maximum area per sign face: 32 sq ft | Not listed |
Zone-by-Zone Sign Requirements in Kennewick(sample of 3 of 15 zones)
Industrial, Light (IL), Industrial, Heavy (IH)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign - Single Business | Up to 60 ft | Up to 150/300/400 sq ft depending on height tier | Not listed | Must comply with clearance triangle (KMC 13.12; KMC 18.27.060) | Up to two per street frontage | Per street frontage | Not listed | Unlock | KMC 18.24.030(1) Table A; KMC 18.24.040(1)-(5),(9) |
| Freestanding Sign - Group of Businesses | Up to 60 ft | ≥90 sq ft per business or up to single-business maxima (150/300/400 sq ft by height) | Not listed | Maintain view clearance triangle | Based on frontage: 0–200 ft = up to 2; 201–400 ft = up to 4; 401–600 ft = up to 5; over 601 ft = up to 6 | Along street frontage(s) | Not listed | Unlock | KMC 18.24.030(1) Table A |
| Wall Sign | Not beyond the top or ends of wall | 25% of applicable wall area | Not listed | Not listed | Any combination, but not to exceed four of projecting/wall/graphic/pictorial per use | Building facade | Not listed | Unlock | KMC 18.24.030(1) Table A (Wall); KMC 18.24.020(29); KMC 18.24.040(1) |
| Projecting Sign | Not more than 5 inches above or beyond the attaching wall | Up to 75 sq ft OR 1/2 frontage, whichever is greater | Not listed | Not listed | Included in the max of four total for projecting/wall/graphic/pictorial per use | Attached to building, projecting | Not listed | Unlock | KMC 18.24.030(1) Table A (Projecting); KMC 18.24.040(1) |
| Pictorial Sign | Maximum building height | 33% of applicable wall area | Not listed | Not listed | Included in the max of four total for projecting/wall/graphic/pictorial per use | On building facade | Not listed | Unlock | KMC 18.24.030(1) Table A (Pictorial); KMC 18.24.040(1) |
| Graphic-Window Sign | Maximum building height | 33% of applicable wall area or applicable window area | Not listed | Not listed | Included in the max of four total for projecting/wall/graphic/pictorial per use | On or within 3 ft of window and visible from exterior | Not listed | Unlock | KMC 18.24.030(1) Table A (Graphic-window); KMC 18.24.020(30); KMC 18.24.060(2)(h); KMC 18.24.040(1) |
| Banner | No maximum specified (ordinance Table A explicitly states None) | No maximum specified (ordinance Table A explicitly states None) | Not listed | Must not obstruct required sight distance | Not specified | As displayed per property; must meet safety/visibility standards | Not listed | Unlock | KMC 18.24.030(1) Table A (Banner row); KMC 18.24.060(2)(g) |
| Non-Commercial Portable Sign (All non-residential zones) | Maximum 6 ft (measured per KMC 18.24.020(26)) | Maximum area per sign face: 32 sq ft | Not listed | Must not create traffic visibility obstruction; comply with view clearance standards | Unlimited, subject to total area cap of 64 sq ft per parcel | On private property or in parking strip (between curb and sidewalk) with abutting property owner permission and no traffic visibility obstruction | Not listed | Unlock | KMC 18.24.050(16)(a),(b),(d) |
Commercial - Central Business District (CBD)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign - Single Business (CBD) | Up to 13 ft | Up to 32 sq ft per sign face | Not listed | Maintain view clearance triangle | One | Per lot; along street frontage | Not listed | Unlock | KMC 18.24.030(2) Table B (Freestanding single business) |
| Freestanding Sign - Group of Businesses (CBD) | Up to 13 ft | Up to 64 sq ft per sign face | Not listed | Maintain view clearance triangle | One | Per lot; along street frontage | Not listed | Unlock | KMC 18.24.030(2) Table B (Freestanding group businesses) |
| Wall Sign (CBD) | Not beyond the top or ends of wall | 25% of applicable wall area | Not listed | Not listed | Not specified (N/A in table) | Building facade | Not listed | Unlock | KMC 18.24.030(2) Table B (Wall); KMC 18.24.020(29) |
| Projecting Sign (CBD) | Up to 10 ft | Up to 24 sq ft per sign face | Not listed | Not listed | One | Attached to building, projecting | Not listed | Unlock | KMC 18.24.030(2) Table B (Projecting) |
| Graphic-Window Sign (CBD) | Maximum building height | 33% of applicable wall area or applicable window area | Not listed | Not listed | Not specified (N/A in table) | On or within 3 ft of window and visible from exterior | Not listed | Unlock | KMC 18.24.030(2) Table B (Graphic-Window); KMC 18.24.020(30); KMC 18.24.060(2)(h) |
| Pictorial Sign (CBD) | Maximum building height | 33% of applicable wall area | Not listed | Not listed | Not specified (N/A in table) | On building facade | Not listed | Unlock | KMC 18.24.030(2) Table B (Pictorial) |
| Banner (CBD) | No maximum specified (ordinance Table A explicitly states None) | No maximum specified (ordinance Table A explicitly states None) | Not listed | Must not obstruct required sight distance | N/A | As displayed per property; must meet safety/visibility standards | Not listed | Unlock | KMC 18.24.030(2) Table B (Banner); KMC 18.24.060(2)(g) |
| Non-Commercial Portable Sign (All non-residential zones) | Maximum 6 ft (measured per KMC 18.24.020(26)) | Maximum area per sign face: 32 sq ft | Not listed | Must not create traffic visibility obstruction; comply with view clearance standards | Unlimited, subject to total area cap of 64 sq ft per parcel | On private property or in parking strip (between curb and sidewalk) with abutting property owner permission and no traffic visibility obstruction | Not listed | Unlock | KMC 18.24.050(16)(a),(b),(d) |
Urban Mixed-Use (UMU)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Sign - Single Business (UMU) | Up to 13 ft | Up to 32 sq ft per sign face | Not listed | Maintain view clearance triangle | One | Per lot; along street frontage | Not listed | Unlock | KMC 18.24.030(2) Table B (Freestanding single business) |
| Freestanding Sign - Group of Businesses (UMU) | Up to 13 ft | Up to 64 sq ft per sign face | Not listed | Maintain view clearance triangle | One | Per lot; along street frontage | Not listed | Unlock | KMC 18.24.030(2) Table B (Freestanding group businesses) |
| Wall Sign (UMU) | Not beyond the top or ends of wall | 25% of applicable wall area | Not listed | Not listed | Not specified (N/A in table) | Building facade | Not listed | Unlock | KMC 18.24.030(2) Table B (Wall); KMC 18.24.020(29) |
| Projecting Sign (UMU) | Up to 10 ft | Up to 24 sq ft per sign face | Not listed | Not listed | One | Attached to building, projecting | Not listed | Unlock | KMC 18.24.030(2) Table B (Projecting) |
| Graphic-Window Sign (UMU) | Maximum building height | 33% of applicable wall area or applicable window area | Not listed | Not listed | Not specified (N/A in table) | On or within 3 ft of window and visible from exterior | Not listed | Unlock | KMC 18.24.030(2) Table B (Graphic-Window); KMC 18.24.020(30); KMC 18.24.060(2)(h) |
| Pictorial Sign (UMU) | Maximum building height | 33% of applicable wall area | Not listed | Not listed | Not specified (N/A in table) | On building facade | Not listed | Unlock | KMC 18.24.030(2) Table B (Pictorial) |
| Banner (UMU) | No maximum specified (ordinance Table A explicitly states None) | No maximum specified (ordinance Table A explicitly states None) | Not listed | Must not obstruct required sight distance | N/A | As displayed per property; must meet safety/visibility standards | Not listed | Unlock | KMC 18.24.030(2) Table B (Banner); KMC 18.24.060(2)(g) |
| Non-Commercial Portable Sign (All non-residential zones) | Maximum 6 ft (measured per KMC 18.24.020(26)) | Maximum area per sign face: 32 sq ft | Not listed | Must not create traffic visibility obstruction; comply with view clearance standards | Unlimited, subject to total area cap of 64 sq ft per parcel | On private property or in parking strip (between curb and sidewalk) with abutting property owner permission and no traffic visibility obstruction | Not listed | Unlock | KMC 18.24.050(16)(a),(b),(d) |
PermitPal covers all 15 zoning districts in Kennewick. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Kennewick
- Off‑premises commercial signs are prohibited in all districts (including off‑premises mobile signs), except as otherwise provided in the chapter.
- Abandoned signs are prohibited in all districts.
- Signs that imitate or resemble official traffic or government signs or signals are prohibited in all districts.
- Signs attached to trees, utility poles, public benches, light poles, or any other public property or right‑of‑way are prohibited.
- Strobe or strobe‑like devices visible from the exterior of a building or location are prohibited for sign illumination.
- Any sign not permitted by Chapter 18.24 is prohibited.
Exempt Signs in Kennewick
- Signs on public transit benches and shelters and on/within public transit vehicles installed under a City franchise are exempt from Chapter 18.24.
- Off‑premises signs for non‑commercial community‑sponsored events (on property other than the event site) are exempt from Chapter 18.24 but must be approved by the Department of Planning for sight visibility and structural safety; allowed up to 14 days prior to the event and must be removed within 3 days after the conclusion of the event season.
- Home occupation signs and signs for family day care homes do not require a building permit.
- Signs 4 square feet or less in area do not require a building permit.
- Development and “For Sale” or “For Rent” signs do not require a building permit.
- Changing sign copy (re‑lettering, replacing/changing the sign face, repainting, cleaning, or other similar nonstructural changes) does not require a building permit.
- Official public notices or signs relating to an emergency do not require a building permit.
- Construction signs do not require a building permit.
- Banners do not require a building permit.
- Window signs do not require a building permit.
- Signs that are required by law do not require a building permit.
- Signs installed in conjunction with a new structure under a current building permit, and that comply with Chapter 18.24, do not require a separate sign building permit.
- Governmental signs placed or required by a city, county, state, or federal agency (including emergency and warning signs, traffic signs, signs required to be displayed by law, signs directing the public to points of interest, and signs showing the location of public facilities) do not require a building permit.
Sign Plan & Submission Notes for Kennewick
- A building permit is required for all signs unless specifically exempted in KMC 18.24.060(2). Permit applications must include owner and user information, site address and location, sign drawings with design and dimensions, structural calculations, and lighting details (KMC 18.24.070).
- Directional signs in commercial (C), industrial (I), or UMU zones require approval of a Land Use Permit for a Conditional Use (KMC 18.42.100). Criteria include lack of arterial frontage for freestanding signage, special site circumstances (location/size/shape/topography), and the ability to condition design for aesthetics, lighting, safety, and compatibility; additional limits apply to location, number, height (preferably ground/monument; max 20 ft if impractical), area (max 32 sq ft), and consistency with any adopted neighborhood/subarea plan or overlay (KMC 18.24.050(4)).
- Rooftop signs in CG, CC, UMU, IL, or IH zones require approval of a Land Use Permit for a Conditional Use (KMC 18.42.110). Criteria include no street frontage available for freestanding signage, wall signs inadequate due to restricted visibility, and conformance with the sign table (KMC 18.24.050(13)).
- Any change in building use or classification that requires site plan approval (KMC 18.42.110), or any new sign structure installation, triggers a requirement to bring applicable signage into conformance with Chapter 18.24; copy modifications are exempt (KMC 18.24.090).
Source: municode municipal code